Laserfiche WebLink
2 <br />RESIDENTIAL BALCONIES (STACKED) <br />5 PSF <br />3 <br />MECHANICAL / ELECTRICAL <br />0 PSF <br />4 <br />PARKING <br />0 PSF <br />5 <br />RAMPS <br />0 PSF <br />6 <br />BALL ROOM / INDOOR AMENITY <br />37.5 PSF <br />8 <br />GROUND LEVEL RETAIL & LOBBIES <br />37.5 PSF <br />12 <br />ROOF <br />15 PSF <br />13 <br />ROOF MECHANICAL <br />15 PSF <br />11 <br />STORAGE <br />10 <br />OUTDOOR AMENITIES <br />50 PSF (SLOPE TO <br />DRAIN), 25 PSF (PAVER) <br />FINISH FLOOR TYPE LOAD ALLOWANCE <br />NOTE: <br />PARTITION WALL AND FLOOR FINISH CONSTRUCTION TYPES ARE SHOWN FOR THE PURPOSE OF <br />DOCUMENTING THE LOAD ALLOWANCE FOR EACH CONSTRUCTION TYPE. REFER TO <br />ARCHITECTURAL DRAWINGS FOR ALL PARTITION AND FLOOR ASSEMBLY CONSTRUCTION. <br />MARK USE <br />UNIFORMLY DISTRIBUTED <br />FLOOR FINISH <br />LOAD ALLOWANCE <br />MARK USE <br />UNIFORMLY DISTRIBUTED <br />FLOOR FINISH <br />LOAD ALLOWANCE <br />7 <br />LOBBIES, CORRIDORS & STAIRS <br />7 PSF <br />T/STRUCT SLAB <br />0 PSF FLOOR FINISH <br />LOAD ALLOWANCE <br />T/STRUCT SLAB <br />NO FLOOR FINISH <br />LOAD ALLOWANCE <br />TRAFFIC COATING / PAINT <br />T/STRUCT SLAB <br />NO FLOOR FINISH <br />LOAD ALLOWANCE <br />TRAFFIC COATING / PAINT <br />T/STRUCT SLAB <br />1" STONE PAVER OR TILE <br />2" MAX CONC TPG SCREED <br />T/STRUCT SLAB <br />T/STRUCT SLAB <br />T/STRUCT SLAB <br />12.5 PSF FLOOR <br />FINISH LOAD <br />ALLOWANCE <br />T/STRUCT SLAB <br />DRAINAGE COMPOSITE <br />WATERPROOFING <br />BUILT-UP INSULATION <br />SELF LEVELING <br />UNDERLAYMENT <br />1" ISOLATION <br />UNDERLAYMENT <br />1/2" WOOD FLOOR, CARPET, <br />OR 3/8" THIN SET TILE <br />MARK USE <br />UNIFORMLY DISTRIBUTED <br />FLOOR FINISH <br />LOAD ALLOWANCE <br />1" STONE PAVER OR TILE <br />2" MAX CONC TPG SCREED <br />TRAFFIC COATING/PAINT <br />TRAFFIC COATING/PAINT <br />12.5 PSF <br />(AT CONCRETE FRAMING) <br />T/STRUCT SLAB <br />DRAINAGE COMPOSITE <br />WATERPROOFING <br />BUILT-UP INSULATION <br />15 <br />STAFF / OFFICE <br />7 PSF <br />T/STRUCT SLAB <br />T/STRUCT SLAB <br />PAVER <br />DRAINAGE COMPOSITE <br />WATERPROOFING <br />4" MAX TOPPING SLAB <br />(POURED W/SLAB <br />@ CONTRACTOR'S OPTION) <br />9 <br />WATER TANK <br />25 PSF SELF LEVELING <br />UNDERLAYMENT <br />1" ISOLATION <br />UNDERLAYMENT <br />1/2" WOOD FLOOR, CARPET, <br />OR 3/8" THIN SET TILE <br />14 <br />POOL <br />250 PSF (WATER) <br />150 PSF (BASIN) <br />1 <br />RESIDENTIAL UNITS <br />7 PSF <br />T/STRUCT SLAB <br />SELF LEVELING <br />UNDERLAYMENT <br />1" ISOLATION <br />UNDERLAYMENT <br />1/2" WOOD FLOOR, CARPET, <br />OR 3/8" THIN SET TILE <br />16 <br />KITCHEN / DINING <br />7 PSF <br />T/STRUCT SLAB <br />1" ISOLATION <br />UNDERLAYMENT <br />1/2" WOOD FLOOR, CARPET, <br />OR 3/8" THIN SET TILE <br />SELF LEVELING <br />UNDERLAYMENT <br />T/STRUCT SLAB <br />TRAFFIC COATING/ PAINT <br />3/8" THIN SET TILE <br />T/STRUCT SLAB <br />DRAINAGE COMPOSITE <br />WATERPROOFING <br />BUILT-UP INSULATION <br />2" (MAX) CONC WEAR SLAB <br />T/STRUCT SLAB <br />4'-0" MAX WATER <br />WATERPROOFING <br />12" MAX POOL BASIN <br /> <br />17 <br />GROUND LEVEL ROADWAY <br />275 PSF <br />T/STRUCT SLAB <br />12" FINISH ALLOWANCE MIN <br />AT LOWEST POINT <br />6" ROADWAY +4" INSULATION+ <br />2" WATER PROOFING <br />. <br />7A <br />ACCESS RAMP <br />5 PSF <br />T/STRUCT SLAB <br />5" MAX LWT TOPPPING <br />18 <br />50 PSF (TOPPING), 50 <br />PSF(GREEN ROOF <br />SYSTEM) <br />19 <br />PLANTER <br />440 PSF (SOIL AND <br />PLANTINGS), 50 PSF <br />(TOPPING) <br />20 <br />HEAVY TREE PLANTERS <br />440 PSF (SOIL), 50 PSF <br />(TOPPING) <br />TREE LOADS PER PLAN <br />T/STRUCT SLAB <br />DRAINAGE COMPOSITE <br />WATERPROOFING <br />4" MAX SLOPE TO DRAIN <br />6" MAX GREEN ROOF SYSTEM <br />T/STRUCT SLAB <br />DRAINAGE COMPOSITE <br />WATERPROOFING <br />4" MAX TOPPING SLAB <br />(POURED W/SLAB @ <br />CONTRACTORS OPTION) <br />48" MAX WET SOIL AND <br />PLANTING (110 PCF) <br />T/STRUCT SLAB <br />DRAINAGE COMPOSITE <br />WATERPROOFING <br />4" MAX TOPPING SLAB <br />(POURED W/SLAB @ <br />CONTRACTORS OPTION) <br />48" MAX WET SOIL (110 PCF) <br />23 <br />FITNESS CENTER / GYM <br />7 PSF <br />T/STRUCT SLAB <br />SELF LEVELING <br />UNDERLAYMENT <br />1" ISOLATION <br />UNDERLAYMENT <br />8MM RUBBER FLOORING <br />T: F: <br />© Gensler <br />Date Description <br />Project Name <br />Project Number <br />Description <br />Scale <br />Seal / Signature <br />2021 <br />Tel 949.863.9434 <br />Fax 949-553-1676 <br />4675 MacArthur Court <br />Suite 100 <br />Newport Beach, CA <br />92600 <br />USA <br />301 N. Broadway, Santa Ana, CA <br />707 Wilshire Blvd, Suite 4450 <br />Los Angeles, CA 90017-3618 <br />Thornton Tomasetti, Inc. <br />213.330.7700 213.330.7001 <br />3RD & BROADWAY - <br />RESIDENTIAL <br />1" = 1'-0" <br />11/19/2024 3:21:14 PM <br />R1.S0.20 <br />FINISH FLOOR TYPE SCHEDULE <br />S21043.00 <br />1 12.10.2021 REISSUE FOR PLAN CHECK <br />A 06.10.2022 REISSUE FOR PLAN CHECK <br />B 06.17.2024 REVISION TO PERMIT <br />1/7/25