SECTION 06 6116 - SOLID SURFACING FABRICATIONS
<br />PART 1 - GENERAL
<br />1.1 REFERENCES:
<br />A. APPLICABLE STANDARDS: STANDARDS OF THE FOLLOWING, AS REFERENCED HEREIN:
<br />1. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI).
<br />2. ASTM INTERNATIONAL (ASTM).
<br />1.2 ACTION SUBMITTALS:
<br />A. SHOP DRAWINGS: INDICATE DIMENSIONS, COMPONENT SIZES, FABRICATION DETAILS
<br />ATTACHMENT PROVISIONS AND COORDINATION REQUIREMENTS WITH ADJACENT
<br />WORK.
<br />B. SAMPLES: SUBMIT MINIMUM 6" BY 6" SAMPLES. INDICATE FULL RANGE OF COLOR AND
<br />PATTERN VARIATION. APPROVED SAMPLES WILL BE RETAINED AS A STANDARD FOR WORK.
<br />C. PRODUCT DATA: INDICATE PRODUCT DESCRIPTION, FABRICATION INFORMATION AND
<br />COMPLIANCE WITH SPECIFIED PERFORMANCE REQUIREMENT.
<br />1.3 CLOSEOUT SUBMITTALS:
<br />A. MAINTENANCE DATA: SUBMIT MANUFACTURER'S CARE AND MAINTENANCE DATA,
<br />INCLUDING REPAIR AND CLEANING INSTRUCTIONS. INCLUDE IN PROJECT CLOSEOUT
<br />DOCUMENTS.
<br />1.5 DELIVERY, STORAGE AND HANDLING:
<br />A. DELIVER NO COMPONENTS TO PROJECT SITE UNTIL AREAS ARE READY FOR
<br />INSTALLATION. STORE INDOORS.
<br />B. HANDLE MATERIALS TO PREVENT DAMAGE TO FINISHED SURFACES. PROVIDE
<br />PROTECTIVE COVERINGS TO PREVENT PHYSICAL DAMAGE OR STAINING FOLLOWING
<br />INSTALLATION FOR DURATION OF PROJECT.
<br />1.6 WARRANTY:
<br />A. PROVIDE MANUFACTURER'S WARRANTY AGAINST DEFECTS IN MATERIALS. WARRANTY
<br />SHALL PROVIDE FOR REPLACEMENT MATERIAL AND LABOR FOR A PERIOD OF FIVE
<br />YEARS, BEGINNING AT DATE OF SUBSTANTIAL COMPLETION.
<br />PART 2 - PRODUCTS
<br />2.1 CAST ACRYLIC SURFACING MATERIAL:
<br />A. ACCEPTABLE PRODUCTS:
<br />1. SEE FINISH LIST FOR SPECIFIED PRODUCT
<br />B. MATERIAL: CAST, 100% ACRYLIC RESIN, SOLID, STRUCTURAL SURFACING MATERIAL.
<br />1. MATERIAL SHALL BE THROUGH-PATTERNED AND HOMOGENEOUS. NO
<br />COATED MATERIALS NOR NON-HOMOGENEOUS MATERIALS ALLOWED.
<br />2. HARDNESS: MINIMUM 55 BARCOL HARDNESS, TESTED IN ACCORD WITH ASTM
<br />D2583-07, OR INIMUM 90 ROCKWELL HARDNESS, TESTED IN ACCORD WITH
<br />ASTM D785-08.
<br />3. TENSILE STRENGTH: MINIMUM 4,200 PSI, TESTED IN ACCORD WITH ASTM
<br />D638-10.
<br />4. ABRASION RESISTANCE: MAXIMUM 0.4 GRAMS AT 1,000 CYCLES, TESTED IN
<br />ACCORD WITH ASTM C501-84(2009).
<br />5. FIRE-RESISTANCE: FLAME SPREAD AND SMOKE DEVELOPED MEETING ASTM
<br />E84-12C, CLASS I RATING.
<br />6. COLOR STABILITY: NO CHANGE IN 200 HOURS, TESTED IN ACCORD WITH
<br />NEMA LD3-2005.
<br />7. WATER ABSORPTION: MAXIMUM 0.04% FOR 3/4" THICKNESS AND 0.06% FOR
<br />1/2" THICKNESS, TESTED IN ACCORD WITH ASTM D570-98(2010).
<br />8. FUNGAL RESISTANCE: NO ATTACK WHEN TESTED IN ACCORD WITH ASTM
<br />G21-09.
<br />9. BACTERIAL RESISTANCE: NO ATTACK WHEN TESTED IN ACCORD WITH ASTM
<br />G22-76(1996)(WITHDRAWN 2002).
<br />10. IMPACT RESISTANCE: NO FRACTURE WHEN TESTED IN ACCORD WITH NEMA
<br />LD3-2005; SECTION 3.3, 144" DROP FOR 1/2" THICKNESS AND 204" DROP FOR
<br />3/4" THICKNESS.
<br />11. SUPERFICIAL DAMAGE TO A DEPTH OF 0.10" SHALL BE REPAIRABLE BY
<br />SANDING AND POLISHING.
<br />12. SURFACES SHALL BE UN AFFECTED BY CLASS I REAGENTS AND SHALL BE
<br />REPAIRABLE AFTER EXPOSURE TO CLASS II REAGENTS. CLASS I AND II
<br />REAGENTS SHALL BE AS IDENTIFIED IN BASIS OF DESIGN MANUFACTURER'S
<br />PRODUCT DATA.
<br />13. SURFACES AT DRUG COMPOUNDING COUNTER IN THE PHARMACY ARE TO BE
<br />CHEMICAL RESISTANT.
<br />C. FINISH: MATTE (GLOSS RATING OF 5-20).
<br />D. COLOR: AS SELECTED BY ARCHITECT.
<br />E. THICKNESS: AS INDICATED IN DRAWINGS.
<br />2.2 ACCESSORY PRODUCTS:
<br />A. JOINT ADHESIVE: MANUFACTURER'S STANDARD, TWO-PART ADHESIVE KIT TO CREATE
<br />INCONSPICUOUS, NON-POROUS JOINTS, WITH A CHEMICAL BOND.
<br />B. SEALANT: MANUFACTURER'S STANDARD MILDEW-RESISTANT, USDA/UL RECOGNIZED
<br />SILICONE SEALANT IN COLOR MATCHING SURFACING OR CLEAR FORMULATIONS.
<br />C. ADHESIVES AND SEALANTS VOC CONTENT: ADHESIVE AND SEALANTS SHALL HAVE A
<br />VOC CONTENT LESS THAN THE CURRENT VOC CONTENT LIMITS OF SOUTH COAST
<br />AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) RULE #1168, ADHESIVES AND
<br />SEALANTS, AMENDED JANUARY 7, 2005.
<br />2.3 FABRICATION:
<br />A. FACTORY-FABRICATE COMPONENTS TO GREATEST EXTENT PRACTICABLE, TO SIZES
<br />AND SHAPES INDICATED, IN ACCORD WITH APPROVED SHOP DRAWINGS.
<br />B. FORM JOINTS BETWEEN COMPONENTS USING MANUFACTURER'S STANDARD JOINT
<br />ADHESIVE; WITHOUT CONSPICUOUS JOINTS AND WITHOUT VOIDS. ATTACH A 2" WIDE
<br />REINFORCING STRIP OF SOLID SURFACING UNDER EACH JOINT.
<br />C. PROVIDE FACTORY CUTOUTS FOR PLUMBING FITTINGS AND ACCESSORIES AS INDICATED.
<br />D. ROUT AND FINISH COMPONENT EDGES TO A SMOOTH, UNIFORM FINISH. ROUT CUTOUTS
<br />AND SAND EDGES SMOOTH. MACHINE RADII AND CONTOURS TO TEMPLATE. REPAIR OR
<br />REJECT DEFECTIVE AND INACCURATE WORK.
<br />E. EDGE TREATMENT FOR TOPS: AS INDICATED ON DRAWINGS.
<br />2.4 SOURCE QUALITY CONTROL:
<br />A. ALLOWABLE TOLERANCES:
<br />1. VARIATION IN COMPONENT SIZE: + -1/8".
<br />2. LOCATION OF OPENINGS: + -1/8" FROM INDICATED LOCATION.
<br />PART 3 - EXECUTION
<br />3.1 INSTALLATION:
<br />A. INSTALL COMPONENTS PLUMB, LEVEL AND RIGID, SCRIBED TO ADJACENT FINISHES,
<br />IN ACCORD WITH APPROVED SHOP DRAWINGS AND PRODUCT DATA.
<br />B. FORM FIELD JOINTS USING SPECIFIED ADHESIVE, WITH JOINTS INCONSPICUOUS IN
<br />FINISHED WORK.
<br />C. PROVIDE BACK AND END SPLASHES AS INDICATED. ADHERE TO COUNTERTOPS USING
<br />SPECIFIED COLOR-MATCHED SILICONE ADHESIVE.
<br />D. KEEP COMPONENTS CLEAN DURING INSTALLATION. REMOVE ADHESIVES, SEALANTS AND
<br />OTHER STAINS. KEEP CLEAN UNTIL DATE OF SUBSTANTIAL COMPLETION. REPLACE
<br />STAINED COMPONENTS.
<br />E. MAKE PLUMBING CONNECTIONS TO SINKS IN ACCORD WITH DIVISION 22, PLUMBING.
<br />3.2 PROTECTION:
<br />A. PROTECT SURFACES FROM DAMAGE UNTIL DATE OF SUBSTANTIAL COMPLETION. REPAIR
<br />OR REPLACE DAMAGED WORK WHICH CANNOT BE REPAIRED.
<br />END OF SECTION
<br />PART 3 - EXECUTION
<br />3.1 EXAMINATION:
<br />A. EXAMINE SUBSTRATES, AREAS, AND CONDITIONS WHERE INSTALLATION OF PLASTIC
<br />FABRICATIONS WILL OCCUR, WITH INSTALLER PRESENT, FOR COMPLIANCE WITH
<br />MANUFACTURER'S REQUIREMENTS. VERIFY THAT SUBSTRATES AND CONDITIONS ARE
<br />SATISFACTORY FOR INSTALLATION AND COMPLY WITH REQUIREMENTS SPECIFIED.
<br />3.2 INSTALLATION:
<br />A. GENERAL: COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS FOR THE
<br />INSTALLATION OF PLASTIC FABRICATIONS.
<br />B. MANUFACTURER'S SHOP TO FABRICATE ITEMS TO THE GREATEST DEGREE POSSIBLE.
<br />C. UTILIZE FASTENERS, ADHESIVES AND BONDING AGENTS RECOMMENDED BY
<br />MANUFACTURER FOR TYPE OF INSTALLATION INDICATED. MATERIAL THAT IS CHIPPED,
<br />WARPED, HAZED OR DISCOLORED AS A RESULT OF INSTALLATION OR FABRICATION
<br />METHODS WILL BE REJECTED.
<br />D. INSTALL COMPONENTS PLUMB, LEVEL AND RIGID, SCRIBED TO ADJACENT FINISHES,
<br />IN ACCORDANCE WITH APPROVED SHOP DRAWINGS AND PRODUCT DATA.
<br />E. FORM FIELD JOINTS MANUFACTURER'S RECOMMENDED PROCEDURES. LOCATE SEAMS
<br />IN PANELS SO THAT THEY ARE NOT DIRECTLY IN LINE WITH SEAMS IN SUBSTRATES.
<br />3.3 CLEANING AND PROTECTION:
<br />A. PROTECT SURFACES FROM DAMAGE UNTIL DATE OF SUBSTANTIAL COMPLETION.
<br />REPAIR
<br />WORK OR REPLACE DAMAGED WORK, WHICH CANNOT BE REPAIRED TO ARCHITECT'S
<br />SATISFACTION.
<br />END OF SECTION
<br />DIVISION 7 - THERMAL AND MOISTURE PROTECTION
<br />SECTION 07 8400 - FIRESTOPPING
<br />PART 1 - GENERAL
<br />1.1 SUMMARY:
<br />A. RELATED WORK:
<br />1. GYPSUM BOARD.
<br />2. PLUMBING.
<br />3. ELECTRICAL.
<br />1.2 SYSTEM PERFORMANCE REQUIREMENTS:
<br />A. FIRESTOPPING SYSTEMS SHALL PROVIDE RESISTANCE TO SPREAD OF FIRE, AND
<br />PASSAGE OF SMOKE AND OTHER GASES ACCORDING TO REQUIREMENTS INDICATED,
<br />INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
<br />1. FIRESTOP PENETRATIONS PASSING THROUGH FIRE RESISTANCE RATED WALL
<br />AND FLOOR ASSEMBLIES AND OTHER LOCATIONS AS INDICATED ON DRAWINGS.
<br />2. PENETRATION FIRESTOPPING SYSTEMS SHALL HAVE BEEN TESTED AND
<br />APPROVED BY A THIRD PARTY TESTING AGENCY.
<br />3. THROUGH-PENETRATION FIRESTOP SYSTEMS AND DEVICES SHALL RESIST
<br />SPREAD OF FIRE, AND PASSAGE OF SMOKE AND OTHER GASES ACCORDING
<br />TO REQUIREMENTS INDICATED, INCLUDING BUT NOT LIMITED TO THE
<br />FOLLOWING:
<br />A. F - RATING SHALL EQUAL OR EXCEED THE RATING OF THE
<br />FIRE-RESISTIVE CONSTRUCTION ASSEMBLY THROUGH WHICH THE
<br />PENETRATION IS MADE, AS DETERMINED BY ASTM E814-11A, BUT
<br />SHALL NOT BE NOT LESS THAN 1-HOUR.
<br />B. T- RATING, IN ADDITION TO F-RATING, AT PENETRATIONS LOCATED
<br />OUTSIDE OF A WALL CAVITY, SHALL EQUAL FIRE-RESISTIVE RATING
<br />OF FLOOR CONSTRUCTION, AS DETERMINED BY ASTM E814-11A,
<br />BUT SHALL BE NOT LESS THAN 1-HOUR.
<br />C. L - RATING: IN ADDITION TO F AND T RATINGS, FIRESTOPPING SHALL
<br />HAVE AN L - RATING, AS DETERMINED BY UL 1479, WHERE INDICATED
<br />BY CODE.
<br />4. FIRESTOP SYSTEMS USING CEMENTITIOUS FILL MATERIALS SHALL NOT BE
<br />PERMITTED.
<br />5. SYSTEMS USED WITHIN OR ADJACENT TO OCCUPIED SPACES SHALL BE FREE
<br />OF VOLATILE SOLVENTS, NOXIOUS FUMES AND STRONG ODORS.
<br />1.3 ACTION SUBMITTALS:
<br />A. SHOP DRAWINGS: SUBMIT DETAILED DRAWINGS OF EACH TYPE AND SIZE PENETRATION
<br />THROUGH FIRE-RATED CONSTRUCTION, INDICATING MATERIALS, DIMENSIONS,
<br />ASSEMBLY CONSTRUCTION AND RATING. INDICATE THROUGH-PENETRATION FIRESTOP
<br />SYSTEM DESIGN LISTINGS, INCLUDING ILLUSTRATIONS FROM A QUALIFIED TESTING AND
<br />INSPECTION AGENCY FOR EACH TYPE PENETRATION.
<br />B. PRODUCT DATA: SUBMIT PRODUCT DATA AND INSTALLATION INSTRUCTIONS FOR EACH
<br />TYPE OF INSTALLATION. INCLUDE INSTALLATION DETAILS AND TEST REPORTS
<br />INDICATING THAT FIRESTOPPING MATERIALS, SYSTEMS AND DEVICES MEET SPECIFIED
<br />REQUIREMENTS AND DESIGN CRITERIA. INDICATE CLASSIFICATION MARKING OF
<br />QUALIFIED TESTING AND INSPECTION AGENCY.
<br />1.4 QUALITY ASSURANCE:
<br />A. APPLICABLE STANDARDS; STANDARDS OF THE FOLLOWING, AS REFERENCED HEREIN:
<br />1. ASTM INTERNATIONAL (ASTM).
<br />2. FACTORY MUTUAL RESEARCH (FMR)
<br />3. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA).
<br />4. UNDERWRITERS LABORATORIES, INC. (UL).
<br />B. FIRE-TEST-RESPONSE CHARACTERISTICS: PROVIDE FIRESTOPPING SYSTEM DESIGN
<br />LISTING BY A TESTING AND INSPECTION AGENCY IN ACCORD WITH THE SPECIFIED
<br />UL STANDARDS.
<br />C. ACCEPTABLE INSTALLER SHALL BE:
<br />1. INSTALLER QUALIFICATIONS: A FIRM THAT HAS BEEN APPROVED BY FM
<br />GLOBAL ACCORDING TO FM GLOBAL 4991, "APPROVAL OF FIRESTOP
<br />CONTRACTOR," OR BEEN EVALUATED BY UL AND FOUND TO COMPLY WITH
<br />UL's "QUALIFIED FIRESTOP CONTRACTOR PROGRAM REQUIREMENTS."
<br />2. LICENSED BY STATE OR LOCAL AUTHORITY, WHERE APPLICABLE.
<br />D. SINGLE SOURCE RESPONSIBILITY: OBTAIN FIRESTOP SYSTEMS FOR EACH KIND OF
<br />PENETRATION AND CONSTRUCTION CONDITION INDICATED FROM A SINGLE PRIMARY
<br />FIRESTOP SYSTEMS MANUFACTURER.
<br />1. MATERIALS FROM DIFFERENT MANUFACTURER THAN ALLOWED BY TESTED
<br />AND LISTED SYSTEM SHALL NOT BE INTERMIXED IN THE SAME FIRESTOP
<br />SYSTEM OR OPENING.
<br />2. INSTALL TESTED AND LISTED FIRESTOP SYSTEMS BEFORE INSTALLING AN
<br />ENGINEERING JUDGEMENT OR EQUIVALENT FIRE RESISTANCE RATED
<br />ASSEMBLY (EFFRA).
<br />E. SECURE INSPECTION AND APPROVAL OF FIRESTOPPING WORK BY BUILDING OFFICIALS
<br />PRIOR TO CONCEALMENT.
<br />F. SUPPORT PENETRATING ELEMENTS INDEPENDENTLY OF FIRESTOPPING SYSTEMS OR
<br />DEVICES.
<br />G. DO NOT COVER UP FIRESTOPPING INSTALLATIONS UNTIL OWNER'S INSPECTION AGENCY
<br />OR AUTHORITIES HAVING JURISDICTION HAVE EXAMINED EACH INSTALLATION.
<br />PART 2 - PRODUCTS
<br />2.1 MATERIALS, GENERAL:
<br />A. VOC CONTENT: PENETRATION FIRESTOPPING SEALANTS AND SEALANT PRIMERS SHALL
<br />HAVE A VOC CONTENT LESS THAN THE CURRENT VOC CONTENT LIMITS OF SOUTH
<br />COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) RULE #1113, ARCHITECTURAL
<br />COATINGS, RULES IN EFFECT JANUARY 1, 2004.
<br />2.2 THROUGH-PENETRATION FIRESTOP SYSTEMS:
<br />A. ACCEPTABLE MANUFACTURERS; SUBJECT TO COMPLIANCE WITH SPECIFIED
<br />REQUIREMENTS:
<br />1. HILTI USA.
<br />2. 3M FIRE PROTECTION PRODUCTS.
<br />3. SPECIFIED TECHNOLOGIES, INC. (STI).
<br />PART 3 - EXECUTION
<br />3.1 EXAMINATION:
<br />A. EXAMINE AREAS TO RECEIVE FIRESTOPPING MATERIALS PRIOR TO BEGINNING WORK.
<br />VERIFY THAT OPENING AREAS AND DIMENSIONS FOR PENETRATIONS TO RECEIVE
<br />FIRESTOPPING SYSTEMS AND DEVICES DO NOT EXCEED DESIGN REQUIREMENTS.
<br />B. REMOVE PROJECTIONS INTERFERING WITH INSTALLATION. PREPARE SURFACES IN
<br />ACCORD WITH MANUFACTURER'S PRODUCT DATA AND UL THROUGH-PENETRATION
<br />FIRESTOP DEVICES NUMBERS.
<br />3.2 PREPARATION:
<br />A. PRIMING: PRIME SUBSTRATES WHERE RECOMMENDED BY FIRESTOPPING MANUFACTURER
<br />USING THAT MANUFACTURER'S RECOMMENDED PRODUCTS AND METHODS. CONFINE
<br />PRIMERS TO AREAS OF BOND. DO NOT ALLOW SPILLAGE AND MIGRATION ONTO EXPOSED
<br />SURFACES.
<br />B. MASKING TAPE: USE MASKING TAPE TO PREVENT FIRESTOPPING FROM CONTACTING
<br />ADJOINING SURFACES THAT WILL REMAIN EXPOSED UPON COMPLETION OF THE WORK.
<br />REMOVE TAPE AS SOON AS IT IS POSSIBLE TO DO SO WITHOUT DISTURBING THE
<br />FIRESTOPPING SEAL WITH SUBSTRATES.
<br />3.3 INSTALLATION:
<br />A. GENERAL:
<br />1. COMPLY WITH MANUFACTURER'S PRODUCT DATA AND UL CLASSIFIED FOR
<br />THROUGH-PENETRATION FIRESTOP DEVICES NUMBERS.
<br />2. INSTALL FIRESTOPPING MATERIALS FITTED TO ADJACENT CONSTRUCTION
<br />TO FILL VOIDS.
<br />3. FIRESTOP PENETRATIONS THROUGH FIRE-RATED WALLS, PARTITIONS, FLOORS
<br />AND FLOOR/CEILING ASSEMBLIES WITH TESTED ASSEMBLIES IN ACCORD WITH
<br />UL 1479 OR WITH A THROUGH-PENETRATION FIRESTOP SYSTEM OR DEVICE
<br />WHEN TESTED IN ACCORD WITH ASTM E814-11A.
<br />4. FIRESTOPPING SHALL COMPLY WITH CODE REQUIREMENTS.
<br />B. THROUGH-PENETRATION FIRESTOP SYSTEMS AND DEVICES:
<br />1. INSTALL AT PENETRATIONS THROUGH FIRE-RATED FLOOR AND WALL
<br />CONSTRUCTION, INCLUDING PARTITIONS AND FLOOR/ CEILING ASSEMBLIES,
<br />IN ACCORD WITH MANUFACTURER'S PRODUCT DATA AND UL SYSTEM NUMBERS.
<br />PROVIDE MATERIALS AND ACCESSORIES AS REQUIRED.
<br />2. INSTALL INTUMESCENT TYPE FIRESTOP SYSTEMS WHERE PLASTIC PIPING,
<br />CABLE, CONDUIT AND OTHER COMBUSTIBLE ITEMS, INCLUDING INSULATED
<br />METAL PIPES, PENETRATE FIRE-RATED CONSTRUCTION.
<br />3. AT CONTRACTOR'S OPTION, THROUGH-PENETRATION FIRESTOP DEVICES OF
<br />SIMILAR FUNCTION MAY BE INSTALLED IN LIEU OF FIRESTOP SYSTEMS.
<br />4. DO NOT REMOVE FORMING MATERIALS UNLESS SPECIFIED IN SYSTEM DESIGNS.
<br />C. FIRESTOP SEALANT: SEAL PERIMETERS, VOIDS AND JOINTS OF FIRE-RATED WALLS AND
<br />PARTITIONS,INCLUDING ABUTMENT OF FLOOR AND ROOF OR CEILING STRUCTURE, AND
<br />FLUTES OF METAL DECKING.
<br />1. IF REQUIRED BY UL DESIGN, INSTALL MINERAL WOOL OR CERAMIC FIBER IN
<br />CAVITIES, PACKED FULL AND TIGHT WITH ALLOWANCE FOR SEALANT
<br />INSTALLATION.
<br />2. SEAL BOTH FACES OF WALLS AND PARTITIONS WITH FIRESTOP SEALANT. TOOL
<br />SEALANTFLUSH WITH ADJACENT FINISH.
<br />3. IN ACCORD WITH UL FIRE RESISTANCE DIRECTORY DESIGNS, PACKED CONCRETE
<br />AND MASONRY JOINTS SHALL BE SEALED USING FIRESTOP SEALANT OR USING
<br />SEALANT AS SPECIFIED IN JOINT SEALANTS SECTION.
<br />D. MINERAL FIBER SAFING:
<br />1. INSTALL SAFING IN CAVITIES OF PENETRATIONS THROUGH NON-RATED FLOOR
<br />AND WALL CONSTRUCTION, INCLUDING SPACES AROUND PIPING, CONDUITS,
<br />CABLES AND DUCT PENETRATIONS.
<br />2. INSTALL SAFING IN VOIDS AND JOINTS OF NON-RATED WALLS AND PARTITIONS
<br />ABUTTING METAL DECKING OF FLOOR AND ROOD STRUCTURES. PACK FLUTES
<br />OF METAL DECKING SOLID WITH SAFING MATERIAL.
<br />3. SAFING SHALL BE INSTALLED AT JOINTS AND PENETRATIONS IN NON-RATED
<br />CONSTRUCTION NOT EXPOSED TO VIEW AND CONCEALED IN FINISH WORK.
<br />SECURE SAFING BY COMPRESSING INTO VOIDS OR JOINTS AND USING
<br />MANUFACTURER'S STANDARD CLIPS OR CLOSURE PLATES AS REQUIRED.
<br />3.4 CLEANING:
<br />A. CLEAN OFF EXCESS FILL MATERIALS AND SEALANTS ADJACENT TO OPENINGS AND
<br />JOINTS AS WORK PROGRESSES. USE METHODS AND CLEANING MATERIALS APPROVED
<br />BY MANUFACTURERS OF FIRESTOPPING PRODUCTS AND OR ASSEMBLIES IN WHICH
<br />OPENINGS AND JOINTS OCCUR.
<br />B. PROTECT FIRESTOPPING DURING AND AFTER CURING PERIOD FROM CONTACT WITH
<br />CONTAMINATING SUBSTANCES.
<br />END OF SECTION
<br />DIVISION 8 - OPENINGS
<br />SECTION 08 1113
<br />HOLLOW METAL FRAMES
<br />PART 1 - GENERAL
<br />1.01 SUMMARY
<br />A. SECTION INCLUDES:
<br />1. HOLLOW METAL DOORS AND FRAMES OR HOLLOW METAL DOORS AS INDICATED.
<br />2. HOLLOW METAL WINDOW FRAMES OR HOLLOW METAL DOOR AND WINDOW FRAMES.
<br />1.02 DESIGN REQUIREMENTS
<br />A. DOOR-AND-FRAME ASSEMBLIES OR FRAMES SHALL INCLUDE REINFORCING AND PROVISIONS
<br />FOR HARDWARE AS SHOWN AND SPECIFIED. DRAWINGS INDICATE PROFILE AND GENERAL
<br />DETAILS OF STEEL FRAME FABRICATION AND INSTALLATION.
<br />1.03 SUBMITTALS
<br />A. SHOP DRAWINGS: SUBMIT COMPOSITE SHOP DRAWINGS INDICATING DETAILED
<br />RELATIONSHIPS OF INSTALLATION INCLUDING WORK OF ADJACENT CONSTRUCTION, FINISH
<br />HARDWARE, SECURITY, FIRE AND LIFE SAFETY DEVICES, GLAZING, SEALING, AND
<br />REQUIREMENTS FOR FIELD INSTALLATION. INCLUDE ELEVATIONS OF EACH HOLLOW METAL
<br />DOOR TYPE, DETAILS OF EACH FRAME TYPE, LOCATION SCHEDULE OF DOORS AND FRAMES
<br />INDICATING SAME REFERENCE FOR DETAILS AND OPENINGS AS INDICATED ON DRAWINGS,
<br />CONDITIONS OF OPENINGS OF VARIOUS WALL SECTIONS AND MATERIALS, TYPICAL AND
<br />SPECIAL DETAILS OF CONSTRUCTION, METHODS OF ASSEMBLING SECTIONS, LOCATION AND
<br />INSTALLATION REQUIREMENTS FOR HARDWARE, MATERIAL SIZE, SHAPE, AND THICKNESS, AND
<br />JOINTS AND CONNECTIONS.
<br />B. PRODUCT DATA: SUBMIT MANUFACTURER'S PRODUCT DATA INDICATING COMPOSITION AND
<br />CONSTRUCTION FOR EACH FABRICATED ITEM INCLUDING LOUVERS, COATINGS, FINISHES, AND
<br />OTHER COMPONENTS DEMONSTRATING COMPLIANCE WITH REFERENCED STANDARDS.
<br />C. CERTIFICATION: SUBMIT CERTIFICATION OF COMPLIANCE WITH REFERENCED STANDARDS
<br />AND SPECIFIED CRITERIA, INCLUDING BUT NOT LIMITED TO FIRE RATINGS IN ACCORDANCE
<br />WITH UL 10C, PHYSICAL ENDURANCE IN ACCORDANCE WITH ANSI A250.4 AND PRIME PAINT
<br />PERFORMANCE IN ACCORDANCE WITH ANSI A250.10..
<br />1.04 QUALITY ASSURANCE
<br />A. MANUFACTURER QUALIFICATIONS: MINIMUM DOCUMENTED EXPERIENCE OF MORE THAN
<br />FIVE YEARS IN WORK OF THIS SECTION.
<br />B. INSTALLER QUALIFICATIONS: MINIMUM DOCUMENTED EXPERIENCE OF MORE THAN FIVE
<br />YEARS IN WORK OF THIS SECTION
<br />C. COORDINATE WITH HARDWARE SUPPLIER FOR FABRICATION OF DOORS AND FRAMES TO
<br />RECEIVE HARDWARE ITEMS.
<br />D. REFERENCES: WORK SHALL COMPLY WITH PHYSICAL AND PERFORMANCE REQUIREMENTS
<br />OF FOLLOWING STANDARDS, INCLUDING STANDARDS REFERENCED IN THEM, EXCEPT FOR
<br />MORE STRINGENT PROVISIONS SPECIFIED HEREIN OR REQUIRED BY REGULATORY AGENCIES:
<br />1. ANSI/SDI A250.8, SDI 100 RECOMMENDED SPECIFICATIONS FOR STANDARD STEEL
<br />DOORS AND FAMES.
<br />2. HMMA, GUIDE SPECIFICATIONS FOR COMMERCIAL HOLLOW METAL DOORS &
<br />FRAMES (STANDARD OF NATIONAL ASSOCIATION OF ARCHITECTURAL METAL
<br />MANUFACTURERS).
<br />3. ANSI/SDI A250.4, TEST PROCEDURE AND ACCEPTANCE CRITERIA FOR PHYSICAL
<br />ENDURANCE FOR STEEL DOORS, FRAMES, FRAME ANCHORS AND HARDWARE
<br />REINFORCINGS.
<br />4. ANSI A250.10, TEST PROCEDURE AND ACCEPTANCE CRITERIA FOR PRIME PAINTED
<br />STEEL DOORS AND FRAMES.
<br />5. ANSI A250.6, RECOMMENDED PRACTICE FOR HARDWARE REINFORCING ON
<br />STANDARD STEEL DOORS AND FRAMES.
<br />E. STANDARDS OF FABRICATION AND INSTALLATION:
<br />1. FINISHED WORK SHALL BE OF UNIFORM PROFILE, ACCURATELY FABRICATED, RIGID
<br />AND STRONG, SQUARE AND TRUE, NEAT IN APPEARANCE, SMOOTH AND FREE FROM
<br />DENTS, WAVES, WARPS, BUCKLES, OPEN JOINTS, TOOL MARKS AND/OR OTHER
<br />DEFECTS.
<br />2. STEEL SHEET SHALL BE CLEAN WITH SMOOTH SURFACES FREE OF SCALE, PITTING
<br />OR OTHER DEFECTS.
<br />3. CONSTRUCTION JOINTS SHALL BE FLUSH, TIGHT AND WELDED THEIR FULL LENGTH,
<br />GROUND FLUSH AND SMOOTH ON EXPOSED SURFACES.
<br />4. FRAME AND DOOR REINFORCING AND HARDWARE PROVISIONS SHALL BE
<br />PERFORMED IN FABRICATION SHOP. PROVIDE CUTS, WELDS, AND OTHER
<br />FABRICATIONS BEFORE GALVANIZING OR SHOP PRIMING.
<br />5. LINES AND MOLDED MEMBERS SHALL BE STRAIGHT AND TRUE WITH ANGLES AS
<br />SHARP AS PRACTICAL FOR THICKNESS INVOLVED, SURFACES FLAT, AND FASTENINGS
<br />CONCEALED.
<br />1.05 WARRANTY
<br />A. MANUFACTURER SHALL PROVIDE A FIVE YEAR MATERIAL WARRANTY.
<br />B. INSTALLER SHALL PROVIDE A TWO YEAR FABRICATION AND INSTALLATION WARRANTY.
<br />PART 2 - PRODUCTS
<br />2.01 MANUFACTURERS
<br />A. FRAMES SHALL BE PRODUCTS OF A SINGLE MANUFACTURER.
<br />B. THE FOLLOWING ARE ACCEPTABLE MANUFACTURERS, AS ARE OTHERS THAT CAN
<br />DEMONSTRATE THEIR PRODUCTS ARE EQUIVALENT IN QUALITY, PERFORMANCE AND
<br />COMPLIANCE WITH THESE SPECIFICATIONS.
<br />1. SECURITY METAL PRODUCTS CORP.
<br />2. CURRIES MANUFACTURING, INC.
<br />3. STEELCRAFT.
<br />4. AMWELD METAL DOORS AND FRAMES.
<br />5. STILES CUSTOM METAL, INC.
<br />6. DOOR COMPONENTS INC.
<br />7. CECO DOOR.
<br />8. EQUAL.
<br />C. MATERIALS, FABRICATION AND INSTALLATION MUST COMPLY WITH REQUIREMENTS OF
<br />STANDARDS REFERENCED IN SECTION 1.04, QUALITY ASSURANCE.
<br />2.02 MATERIALS
<br />A. STEEL:
<br />1. INTERIOR DOORS AND FRAMES: COLD-ROLLED STEEL SHEETS, COMMERCIAL
<br />QUALITY CARBON STEEL, ASTM A1008.
<br />2. STEEL SHALL BE FREE OF SCALE, PITTING, COIL BREAKS OR OTHER SURFACE
<br />BLEMISHES, AND FREE OF BUCKLES, WAVES OR OTHER DEFECTS.
<br />3. STEEL THICKNESSES EXPRESSED IN STEEL GAGES (MSG) IS FOR REFERENCE ONLY.
<br />ACTUAL STEEL THICKNESSES MUST MEET MINIMUM REQUIREMENTS OF ASTM
<br />STANDARDS AND AS DESCRIBED IN ANSI/SDI A250.8.
<br />B. SUPPORTS AND ANCHORS: FABRICATE FROM A MINIMUM 16 GAUGE GALVANIZED SHEET
<br />STEEL UNLESS NOTED OTHERWISE.
<br />C. FASTENERS: PROVIDE AS SHOWN ON DRAWINGS AND TO SUIT CONDITIONS OF SECURE
<br />INSTALLATIONS.
<br />D. SHOP PAINT:
<br />1. CONFORM TO STEEL STRUCTURES PAINTING COUNCIL (SSPC) FOR STEEL
<br />COMPONENTS.
<br />2. PRETREATMENT/PRIMING COATINGS SHALL BE COMPATIBLE WITH PROJECT SITE
<br />FINISH PAINTING SYSTEM IN ACCORDANCE WITH SECTION 09 9000.
<br />2.03 FABRICATION GENERAL
<br />A.GENERAL: FABRICATE HOLLOW METAL UNITS TO BE RIGID, NEAT IN APPEARANCE, AND FREE
<br />FROM DEFECTS INCLUDING WARP OR BUCKLE.
<br />1. ACCURATELY FORM METAL TO REQUIRED SIZES AND PROFILES. FIT AND ASSEMBLE
<br />UNITS IN MANUFACTURER’S PLANT. WHERE PRACTICAL, FACTORY OR SHOP FIT AND
<br />ASSEMBLE UNITS FOR SHIPMENT.
<br />2. WELD JOINTS CONTINUOUSLY; GRIND, DRESS, AND MAKE SMOOTH, FLUSH, AND
<br />INVISIBLE. FILLER TO CONCEAL MANUFACTURING DEFECTS OR DAMAGE IS NOT
<br />PERMITTED.
<br />3. CORNER JOINTS: FINISH CORNER JOINTS BY MITERING, OR COPING AND BUTTING,
<br />OR A COMBINATION OF BOTH. TRIM AND BACKBEND SHALL BE CONTINUOUS AROUND
<br />CORNER.
<br />4. CONTINUOUSLY WELD JOINTS FOR FULL DEPTH AND WIDTH OF FRAME, TRIM, AND
<br />BACKBENDS.
<br />5. CLEARANCES FOR FIRE-RATED DOORS: AS REQUIRED BY NFPA 80.
<br />2.04 FRAMES
<br />A. GENERAL: PROVIDE FULLY WELDED STEEL FRAMES WITH INTEGRAL STOPS AND TRIM FOR
<br />DOORS, TRANSOMS, SIDELIGHTS, BORROWED LIGHTS, AND OTHER OPENINGS, AND WITH
<br />DETAILS INDICATED FOR TYPE AND PROFILE. USE CONCEALED FASTENINGS, UNLESS
<br />OTHERWISE INDICATED.
<br />B. METAL THICKNESS OF FRAMES (MINIMUM):
<br />1. INTERIOR HOLLOW METAL FRAMES UP TO 4-FOOT WIDE 16 GAGE
<br />2. INTERIOR HOLLOW METAL FRAMES WIDER THAN 4-FOOT 14 GAGE
<br />C. SUPPORTS AND ANCHORS: FABRICATE FROM AT LEAST 16-GAGE, GALVANIZED STEEL SHEET.
<br />FRAME ANCHORS SHALL COMPLY WITH FIRE RATED LABEL REQUIREMENTS OF OPENING.
<br />1. FLOOR ANCHORS:
<br />A. MINIMUM THICKNESS: 12 GAGE GALVANIZED STEEL SHEET OR BENT
<br />STEEL PLATE, SECURELY FASTENED INSIDE EACH JAMB, WITH TWO HOLES IN
<br />ANCHOR AT EACH JAMB FOR 3/8 INCH FLOOR ANCHORAGE FASTENERS. FOR
<br />PREFRAMED WOOD STUD WALLS PROVIDE AND ADDITIONAL WOOD STUD
<br />ANCHOR LOCATED AS CLOSE TO THE BOTTOM OF THE JAMB AS IS
<br />PRACTICAL.
<br />B. WHERE REQUIRED AT SLOPING AND UNEVEN FLOOR CONDITIONS, OR TO
<br />COORDINATE ADJUSTMENTS FOR TRIM ALIGNMENTS, PROVIDE ADJUSTABLE
<br />FLOOR ANCHORS, PROVIDING AT LEAST 2-INCH HEIGHT ADJUSTMENTS.
<br />2. JAMB ANCHORS:
<br />A. LOCATE ANCHORS NEAR TOP AND BOTTOM AND AT INTERMEDIATE POINTS
<br />NOT TO EXCEED 24 INCHES ON CENTER. PROVIDE TWO ANCHORS PER HEAD
<br />FOR OPENINGS UP TO 48 INCHES WIDE; OVER 48 INCHES WIDE PROVIDE
<br />ANCHORS AT 24 INCHES ON CENTER MAXIMUM.
<br />B. ANCHORS IN STUD PARTITIONS: PROVIDE STEEL ANCHORS, 16 GAGE
<br />MINIMUM SHEET STEEL, OF DESIGN TO SUIT PARTITION CONSTRUCTION,
<br />SECURELY WELDED INSIDE EACH JAMB.
<br />C. THROUGH-FRAME ANCHORS: AT FRAMES INDICATED TO BE ANCHORED
<br />WITH BOLTS THROUGH FRAME, PROVIDE COUNTERSUNK HOLES FOR BOLTS
<br />WITH 16 GAUGE MINIMUM SHEET STEEL STIFFENERS FULL THICKNESS OF
<br />FRAME, AND SECURELY WELDED INSIDE EACH FRAME AT EACH HOLE.
<br />D. INSERTS, BOLTS, AND FASTENERS: PROVIDE MANUFACTURER'S STANDARD UNITS. WHERE
<br />ZINC-COATED ITEMS ARE TO BE BUILT INTO EXTERIOR WALLS, COMPLY WITH ASTM A153 CLASS
<br />C OR D AS REQUIRED.
<br />E. HEAD REINFORCING: REINFORCING SHALL NOT ACT AS LINTEL OR LOAD-CARRYING MEMBER
<br />AND SHALL COMPLY WITH FIRE RATING REQUIREMENTS. PROVIDE AT FRAMES REGARDLESS
<br />OF WHETHER A CLOSER IS CALLED FOR.
<br />F. HARDWARE REINFORCEMENT AND ACCESSORIES:
<br />1. BUTT HINGE: 7 GAGE MINIMUM.
<br />2. CONTINUOUS HINGE: 14 GAGE CONTINUOUS STRIP REINFORCING.
<br />3. HEAD ASSEMBLIES: REINFORCED INTERNALLY WITH, FULL LENGTH, 10 GAGE
<br />ANGLES ON EACH SIDE OF FRAME AND BAR AT BOTTOM OF STOP FOR CLOSER
<br />REINFORCEMENT IN FRAMES AS SHOWN IN DETAIL #2 OF THIS SECTION.
<br />4. REINFORCING FOR OTHER ITEMS OF FINISH HARDWARE SHALL BE ACCOMPLISHED
<br />ACCORDING TO ANSI A250.6.
<br />G. GLAZED OPENINGS: APPLIED STOPS WITH MITERED OR BUTTED CORNERS, OF MINIMUM 18
<br />GAGE GALVANIZED STEEL, ONE-PIECE LENGTHS, SECURED WITHIN 3” OF ENDS AND AT 12”
<br />CENTERS WITH OVAL HEAD COUNTERSUNK TAMPER RESISTANT SCREWS. CORNER JOINTS
<br />SHALL BE FURNISHED WITH CONTACT EDGES CLOSED TIGHT, WITH TRIM FACES MITERED AND
<br />CONTINUOUSLY WELDED. FRAMES FOR MULTIPLE OPENINGS SHALL BE PROVIDED WITH
<br />MULLION AND/OR RAIL MEMBERS, FABRICATED OF CLOSED TUBULAR SHAPES WITH NO VISIBLE
<br />SEAMS OR JOINTS. JOINTS BETWEEN FACES OF ABUTTING MEMBERS SHALL BE SECURELY
<br />WELDED AND FINISHED SMOOTH. PROVIDE CONDENSATE WEEPS 4 INCHES ON CENTERS,
<br />MAXIMUM.
<br />I. DOOR SILENCERS: DRILL AND PUNCH FRAMES FOR THREE SILENCERS AT LOCK JAMB OF
<br />SINGLE SWING DOORS OR IN DOUBLE DOORS WITH ASTRAGAL AND ONE SILENCER PER LEAF IN
<br />HEADS OF DOUBLED DOOR FRAMES.
<br />J. WHERE FRAMES ARE INSTALLED IN WALLS SITTING ON A CONCRETE CURB, PROVIDE A
<br />CLOSURE PLATE OR EXTEND BACKBENDS TO PROVIDE CLOSURE WHERE FRAME ABUTS
<br />CONCRETE CURB
<br />2.05 SHOP PRIMING
<br />A. EXPOSED AND CONCEALED METAL SURFACES OF HOLLOW METAL DOORS, FRAMES AND
<br />OTHER HOLLOW METAL WORK OF THIS SECTION SHALL BE BONDERIZED AND THEN SHOP
<br />PRIMED.
<br />B. EXPOSED SURFACES OF DOORS, FRAMES AND ACCESSORIES SHALL BE FILLED, SANDED
<br />SMOOTH AND CLEANED BEFORE PAINTING.
<br />C. EXPOSED SURFACES SHALL BE SHOP PRIMED AFTER ASSEMBLY.
<br />PART 3 - EXECUTION
<br />3.01 FRAME INSTALLATION
<br />A. INSTALL STEEL FRAMES ACCURATELY IN LOCATION, PERFECT ALIGNMENT, PLUMB,
<br />STRAIGHT AND TRUE. BRACE FRAMES TO PREVENT DISPLACEMENT.
<br />B. ANCHOR FRAMES IN STEEL AND WOOD FRAME PARTITIONS WITH MANUFACTURER
<br />RECOMMENDED ANCHORS.
<br />C. INSTALL FRAME AT FIRE RATED OPENINGS IN ACCORDANCE WITH NFPA STANDARD NO. 80.
<br />D. FURNISH FILLER FOR ANCHOR ATTACHMENT SCREWS, AND SAND SMOOTH.
<br />3.02 PRIME COAT TOUCH-UP
<br />A. IMMEDIATELY AFTER INSTALLATION, REMOVE RUST, REPAIR DAMAGED SURFACES TO NEW
<br />CONDITION, SAND SMOOTH, AND INSTALL TOUCH-UP PRIMER.
<br />3.03 CLEAN UP
<br />A. REMOVE RUBBISH, DEBRIS AND WASTE MATERIALS AND LEGALLY DISPOSE OF OFF PROJECT
<br />SITE.
<br />3.04 PROTECTION
<br />A. PROTECT WORK OF THIS SECTION UNTIL SUBSTANTIAL COMPLETION.
<br />END OF SECTION
<br />SECTION 08 1416
<br />FLUSH WOOD DOORS
<br />PART 1 - GENERAL
<br />1.01 SUMMARY
<br />A. SECTION INCLUDES:
<br />1. WOOD DOORS.
<br />B. RELATED REQUIREMENTS:
<br />1. DIVISION 01 - GENERAL REQUIREMENTS.
<br />2. SECTION 06 2000 - FINISH CARPENTRY.
<br />3. SECTION 08 1113 - HOLLOW METAL DOORS AND FRAMES
<br />4. SECTION 08 7100 - DOOR HARDWARE.
<br />5. SECTION 08 8000 - GLAZING.
<br />6. SECTION 09 9000 - PAINTING AND COATING.
<br />1.02 DESIGN REQUIREMENTS
<br />A. DRAWINGS INDICATE SIZES, LOCATIONS AND GENERAL DETAILS OF WOOD DOOR
<br />CONSTRUCTION AND INSTALLATION.
<br />1.03 SUBMITTALS
<br />A. SHOP DRAWINGS: SUBMIT SCHEDULES, PLANS, ELEVATIONS AND DETAILS INDICATING DOOR
<br />CONSTRUCTION DETAILS, OPENING IDENTIFICATION SYMBOLS, SIZES, DOOR TYPE AND GRADE,
<br />FIRE CLASSIFICATION, SWING, LIGHT AND LOUVER CUTOUT SIZE AND LOCATIONS, AND
<br />UNDERCUTS.
<br />B. PRODUCT DATA: SUBMIT MANUFACTURERS TECHNICAL DATA FOR EACH SPECIFIED DOOR
<br />TYPE, INCLUDING DETAILS OF WOOD SPECIES, DESIGN AND CONSTRUCTION, FACTORY
<br />FINISHING SPECIFICATIONS AND INSTALLATION INSTRUCTIONS.
<br />C. CERTIFICATES:
<br />1. SUBMIT CERTIFICATE THAT SOLID CORE DOORS COMPLY WITH ALL REQUIREMENTS
<br />OF ANSI/WDMA I.S. 1-A.
<br />2. SUBMIT CERTIFICATION THAT FIRE RATED DOORS COMPLY WITH CBC SECTION 715
<br />OR UL 10B.
<br />1.04 QUALITY ASSURANCE
<br />A. WOOD DOORS CONSTRUCTION, MANUFACTURE, AND FABRICATION SHALL CONFORM TO
<br />ANSI/WDMA I.S. 1-A, CUSTOM GRADE, EXTRA HEAVY DUTY GRADE INCLUDING THE LATEST
<br />REVISIONS, AND SPECIAL REQUIREMENTS SPECIFIED.
<br />B. DOORS SHALL BE FABRICATED, HARDWARE FACTORY FITTED AND MACHINED, AND FACTORY
<br />FINISHED, UNLESS NOTED OTHERWISE.
<br />C. WOOD DOOR FINISHES SHALL COMPLY WITH THE ARCHITECTURAL WOODWORK INSTITUTE
<br />STANDARDS.
<br />D. DOORS SHALL BE PRODUCTS OF ONE MANUFACTURER.
<br />1.05 WARRANTY
<br />A. MANUFACTURER SHALL PROVIDE A TWO YEAR MATERIAL WARRANTY FOR EXTERIOR
<br />DOORS.
<br />B. MANUFACTURER SHALL PROVIDE A LIFE TIME MATERIAL WARRANTY FOR INTERIOR
<br />DOORS.
<br />C. INSTALLER SHALL PROVIDE A TWO YEAR FABRICATION AND INSTALLATION WARRANTY
<br />FOR ALL DOORS.
<br />PART 2 - PRODUCTS
<br />2.01 MANUFACTURERS
<br />A. PROVIDE PRODUCTS MANUFACTURED BY ONE OF THE FOLLOWING:
<br />1. ALGOMA HARDWOOD INC.
<br />2. BRENTWOOD MANUFACTURING.
<br />3. EGGERS INDUSTRIES.
<br />4. MOHAWK FLUSH DOOR, INC
<br />5. VT INDUSTRIES, INC.
<br />6. WESTERN OREGON DOOR.
<br />7. EQUAL.
<br />2.02 DOOR CONSTRUCTION
<br />A. INTERIOR FLUSH DOORS:
<br />1. INTERIOR DOORS SHALL BE FURNISHED AS FOLLOWS:
<br />A. TRANSPARENT FINISHED (STAINED): CUSTOM GRADE. SOLID WOOD
<br />CORE, 5 PLY, VENEER FACED, FULLY BONDED TO CORE.
<br />B. OPAQUE FINISHED (PAINTED): CUSTOM GRADE. SOLID WOOD CORE, 5 PLY,
<br />MDO HARDBOARD FACE, FULLY BONDED TO CORE.
<br />2. STRUCTURAL-COMPOSITE-LUMBER-CORE DOORS:
<br />A. STRUCTURAL COMPOSITE LUMBER: WDMA I.S.10.
<br />B. SCREW WITHDRAWAL, FACE: 700 POUND-FEET.
<br />C. SCREW WITHDRAWAL, EDGE: 400 POUND-FEET.
<br />3. EDGE STRIPS: KILN-DRIED BIRCH, MAPLE OR OTHER MATERIAL AS INDICATED.
<br />A. TRANSPARENT FINISHED DOORS: SAME SPECIES AS FACE VENEER OR
<br />SIMILAR IN OVERALL COLOR, GRAIN, CHARACTER AND CONTRAST AS THE
<br />FACE VENEER.
<br />B. OPAQUE FINISHED DOORS: CLOSE GRAIN HARDWOOD.
<br />4. FULL STILE EDGE STRIP SHALL BE NOT LESS THAT 1 ½ INCHES WIDE, TWO PLY
<br />STILE. STILES SHALL BE FULLY BONDED TO THE CORE. THE OUTER FACE STILE
<br />SHALL BE FULL LENGTH ¾ INCH BIRCH OR MAPLE. THE INNER BACK STILE SHALL BE ¾
<br />INCH OF SIMILAR SPECIES WHICH MAY HAVE TWO FINGER JOINTS FULLY BONDED TO
<br />CORE.
<br />5. TOP AND BOTTOM EDGE RAILS SHALL BE FULL LENGTH AND MAY BE OF GLUED UP
<br />STOCK OF SIMILAR SPECIES AS EDGE STRIP, WHITE FIR OR DOUGLAS FIR, MINIMUM
<br />DENSITY 24.33 POUNDS OR HIGHER PER CUBIC FOOT. TOP RAIL SHALL BE MINIMUM
<br />OF 2 INCHES. BOTTOM RAIL SHALL BE MINIMUM OF 5 INCHES FULLY BONDED TO
<br />CORE.
<br />6. CROSSBANDING: DOORS SHALL BE FURNISHED WITH FULL WIDTH CROSSBANDING
<br />OF PROPERLY DRIED HARDWOOD OR ENGINEERED FIBER COMPOSITE MATERIAL, 1/16
<br />INCH THICK, WITH A DENSITY OF 52 POUNDS OR HIGHER PER CUBIC FOOT.
<br />7. FACE VENEER FOR TRANSPARENT FINISHED DOORS: CUSTOM GRADE, VENEER
<br />SHALL BE GRADE”A”. MINIMUM THICKNESS SHALL BE 0.0277 INCHES BEFORE SANDING
<br />AND 0.020 INCHES AFTER SANDING OF SPECIFIED FACE VENEER.
<br />A. VENEER SPECIES:
<br />B. VENEER CUT: ROTARY
<br />C. VENEER MATCH: BOOK
<br />D. PAIRS: NOT MATCHED
<br />8. OPAQUE FINISHED DOORS: CUSTOM GRADE MEDIUM DENSITY OVERLAY
<br />HARDBOARD.
<br />9. ADHESIVE AND BONDING: BONDING BETWEEN VENEER PLIES OF WOOD FACE
<br />PANEL, AND BETWEEN DOOR FACES, FRAME AND CORE UNIT SHALL BE FABRICATED
<br />WITH TYPE I OR II WATERPROOF ADHESIVES FOR INTERIOR DOORS.
<br />10. OPENINGS: OPENINGS FOR LIGHTS, LOUVERS AND GRILLES SHALL BE
<br />PERFORMED BY THE MANUFACTURER, OR IN A CERTIFIED DOOR SERVICE MILL IN
<br />ACCORDANCE WITH MANUFACTURER’S DETAILS, AND IN COMPLIANCE WITH TESTING
<br />AGENCY REQUIREMENTS.
<br />2.03 FINISHING:
<br />A. FACTORY FINISHING:
<br />1. FACTORY FINISHING SHALL BE AWI CUSTOM GRADE AND INCLUDE ALL NECESSARY
<br />PREPARATION, MATERIALS AND LABOR TO PROVIDE AN CLEAR TRANSPARENT FINISH.
<br />1. FINISH FACES, ALL FOUR EDGES, EDGES OF CUTOUTS, AND MORTISES.
<br />STAINS AND FILLERS MAY BE OMITTED ON TOP AND BOTTOM EDGES, EDGES
<br />OF CUTOUTS, AND MORTISES.
<br />2. FINISH: UV CURABLE, WATER BASED.
<br />3. STAINING: AS SELECTED BY ARCHITECT FROM MANUFACTURER'S FULL
<br />RANGE.
<br />4. SHEEN: SEMIGLOSS.
<br />B. JOB SITE FINISHING:
<br />1. DOORS INDICATED TO BE JOB SITE FINISHED SHALL BE FACTORY BACK PRIMED.
<br />A. DOORS SCHEDULED FOR OPAQUE PAINT FINISH: PRIME WITH ONE COAT
<br />OF WOOD PRIMER INDICATED ON SECTION 09 9000 - PAINTING AND COATING.
<br />B. DOORSSCHEDULES FOR TRANSPARENT FINISH: PRIME WITH STAIN AND
<br />FIRST COAT OF FINISH AS INDICATED IN SECTION 09 9000 - PAINTING AND
<br />COATING.
<br />2. DOOR FINISH: PER SECTION 09 9000 - PAINTING AND COATING.
<br />PART 3 - EXECUTION
<br />3.01 INSTALLATION
<br />A. PROVIDE EACH DOOR ACCURATELY CUT, TRIMMED, AND FITTED TO ITS FRAME AND
<br />HARDWARE. CLEARANCE AT LOCK AND HANGING STILE AND AT TOP SHALL BE 1/8 INCH, AND
<br />BOTTOM SHALL NOT EXCEED 1/4 INCH EXCEPT WHERE OTHERWISE INDICATED. ARISES SHALL
<br />BE ROUNDED TO A 1/16 INCH RADIUS, AND LOCK RAIL EDGES SHALL BE SLIGHTLY BEVELED.
<br />SCREWS FOR HARDWARE SHALL NOT BE DRIVEN BUT SCREWED INTO PRE-DRILLED HOLES.
<br />B. DOORS SHALL OPERATE FREELY, BUT NOT LOOSELY, WITHOUT STICKING OR BINDING,
<br />WITHOUT HINGE-BIND CONDITIONS AND WITH HARDWARE PROPERLY ADJUSTED AND
<br />FUNCTIONING.
<br />3.02 CLEAN UP
<br />A. REMOVE RUBBISH, WASTE AND DEBRIS AND LEGALLY DISPOSE OF OFF THE PROJECT SITE.
<br />3.03 PROTECTION
<br />A. PROTECT THE WORK OF THIS SECTION UNTIL SUBSTANTIAL COMPLETION.
<br />END OF SECTION
<br />SECTION 08 8000
<br />GLAZING
<br />PART 1 - GENERAL
<br />1.01 SUMMARY
<br />A. SECTION INCLUDES:
<br />1. GLASS AND GLAZING AS INDICATED.
<br />B. RELATED REQUIREMENTS:
<br />1. DIVISION 01 - GENERAL REQUIREMENTS.
<br />2. SECTION 08 1416 - FLUSH WOOD DOORS.
<br />3. SECTION 08 5113 - ALUMINUM WINDOWS.
<br />1.02 SUBMITTALS
<br />A. PRODUCT DATA: SUBMIT MANUFACTURER'S DESCRIPTIVE LITERATURE AND I
<br />INSTALLATION RECOMMENDATIONS FOR GLASS, GLAZING, AND ACCESSORIES.
<br />B. MATERIAL SAMPLES: SUBMIT 6-INCH SQUARE UNITS OF EACH TYPE OF GLASS
<br />SPECIFIED.
<br />1.03 QUALITY ASSURANCE
<br />A. LABELING: LABEL EACH PIECE OF GLASS AND GLAZING AND MIRRORS WITH M
<br />MANUFACTURER'S NAME, AND THE GRADE OR QUALITY OF THE MATERIAL. LABELS
<br />SHALL BE INTACT BEFORE AND AFTER INSTALLATION. FIRE-PROTECTION-RATED
<br />GLAZING SHALL BEAR A LABEL OR OTHER IDENTIFICATION IN ACCORDANCE TO
<br />CBC 715.5.
<br />B. COMPLY WITH THE FOLLOWING AS A MINIMUM REQUIREMENT:
<br />1. ASTM C864 - STANDARD SPECIFICATION FOR DENSE ELASTOMERIC
<br />COMPRESSION SEAL GASKETS, SETTING BLOCKS, AND SPACERS.
<br />2. ASTM C1036 - STANDARD SPECIFICATION FOR FLAT GLASS.
<br />3. ASTM C1048 - STANDARD SPECIFICATION FOR HEAT-TREATED FLAT
<br />GLASS —KIND HS, KIND FT COATED AND UNCOATED GLASS.
<br />4. CPSC 16 CFR 1201 - SAFETY STANDARDS FOR ARCHITECTURAL GLAZING
<br />MATERIALS ISSUED BY THE CONSUMER PRODUCTS SAFETY COMMISSION.
<br />5. GANA - GLAZING MANUAL.
<br />C. QUALIFICATIONS OF INSTALLER: MINIMUM FIVE YEARS EXPERIENCE INSTALLING
<br />GLASS IN PROJECTS OF SIMILAR SCOPE AND COMPLEXITY.
<br />1.04 DELIVERY, STORAGE AND HANDLING
<br />A. DELIVER GLASS AND GLAZING MATERIALS WITH MANUFACTURER'S LABELS INTACT.
<br />B. DO NOT REMOVE LABELS UNTIL GLASS HAS BEEN INSTALLED AND INSPECTED BY
<br />THE PROJECT INSPECTOR.
<br />C. PROTECT GLASS FROM STAINING, MARKING, AND DAMAGE.
<br />D. PUTTY AND GLAZING COMPOUND SHALL BE DELIVERED TO THE PROJECT SITE IN
<br />MANUFACTURER'S ORIGINAL UNBROKEN CONTAINERS LABELED TO IDENTIFY C
<br />ONTENTS.
<br />1.05 PROJECT CONDITIONS
<br />A. PERFORM GLAZING WHEN AMBIENT TEMPERATURE IS ABOVE 40 DEGREES F.
<br />B. PERFORM GLAZING ON CLEAN, DRY SURFACES ONLY.
<br />1.06 WARRANTY
<br />A. MANUFACTURER SHALL PROVIDE A TEN YEAR MATERIAL WARRANTY.
<br />B. MANUFACTURER SHALL PROVIDE A TWENTY YEAR MATERIAL WARRANTY FOR
<br />COATINGS AND THERMALLY OR ACOUSTICALLY RATED INSULATION UNITS AGAINST
<br />DETERIORATION IN ACOUSTIC OR THERMAL RATING.
<br />C. INSTALLER SHALL PROVIDE A THREE YEAR FABRICATIONS AND INSTALLATION
<br />WARRANTY.
<br />PART 2 - PRODUCTS
<br />2.01 ACCEPTABLE MANUFACTURERS AND FABRICATORS
<br />A. TO MAXIMUM EXTENT POSSIBLE, PROVIDE DOMESTICALLY MANUFACTURED AND
<br />FABRICATED GLASS, AND PROVIDE GLASS FROM ONE MANUFACTURER.
<br />B. TYPES OF GLASS SPECIFIED OR INDICATED SHALL BE MANUFACTURED OR
<br />FABRICATED BY ONE OF THE FOLLOWING (U.N.O.):
<br />1. PILKINGTON LOF (FIRE RATED GLAZING).
<br />2. PPG GLASS TECHNOLOGY.
<br />3. VISTEON FLOAT GLASS OPERATIONS.
<br />4. VIRACON.
<br />5. SOUTHWEST TECHNOLOGIES.
<br />6. EQUAL.
<br />2.02 GLASS MATERIALS
<br />A. GENERAL: CONFORM TO ASTM C1036, ASTM C1048 AND TO ANSI Z97.1. LABEL
<br />FACTORY CUT PANES.
<br />B. FLOAT GLASS: TYPE I, (TRANSPARENT GLASS FLAT), CLASS 1 (CLEAR), QUALITY Q3,
<br />(GLAZING SELECT), MINIMUM 1/4 INCH THICKNESS UNLESS OTHERWISE INDICATED O
<br />R REQUIRED.
<br />C. TINTED FLOAT GLASS: TYPE I (TRANSPARENT GLASS), CLASS 2 (TINTED HEAT
<br />ABSORBING AND LIGHT REDUCING), QUALITY Q3 (GLAZING SELECT),
<br />MANUFACTURED BY PPG OR LOF, COLOR AS SELECTED BY ARCHITECT, MINIMUM 1/4
<br />INCH THICKNESS UNLESS OTHERWISE INDICATED OR REQUIRED.
<br />D. TEMPERED GLASS: CONDITION A (UNCOATED SURFACES), TYPE I OR II, CLASS 1,
<br />QUALITY Q3 (GLAZING SELECT), KIND FT (FULLY TEMPERED GLASS), MATCH COLOR
<br />OF CLEAR OR TINTED GLASS AS APPLICABLE; FULLY THERMAL TEMPERED, HEAT
<br />STRENGTHENING OR CHEMICAL TEMPERING IS NOT PERMITTED. PERFORM
<br />TEMPERING BY HORIZONTAL OSCILLATING ROLLER HEARTH OR HIGH SPEED R
<br />OLLER HEARTH PROCESS. DO NOT PERMIT FABRICATION PROCESSES LEAVING
<br />GRIPPER OR TONG MARKS. HANDLE AND SIZE GLASS ACCORDING TO
<br />MANUFACTURER'S WRITTEN INSTRUCTIONS.
<br />E. CLEAR LAMINATED GLASS: TWO LAYERS OF 1/8 INCH CLEAR FLOAT GLASS WITH
<br />0.030 INCH THICK HIGH STRENGTH POLYVINYL BUTYRAL LAMINATING SHEET.
<br />F. TINTED LAMINATED GLASS: ONE LAYER OF 1/8 INCH CLEAR FLOAT GLASS AND ONE
<br />LAYER OF TINTED GLASS TO MATCH OTHER WINDOWS, WITH 0.030 INCH THICK HIGH
<br />STRENGTH POLYVINYL BUTYRAL LAMINATING SHEET. EDGES OF
<br />LAMINATED GLASS SHALL BE TREATED WITH ARGOTEC, ARGO EDGE SEAL PLUS, OR
<br />EQUAL, EDGE PROTECTION TO PREVENT CONTACT OF LAMINATING SHEET WITH
<br />SEALANTS.
<br />G. LOW EMISSIVITY GLASS (LOW E GLASS): PROVIDE UNITS WITH THIN METALLIC HIGH-
<br />TRANSMITTANCE COATING APPLIED TO THE NUMBER 3 SURFACE OF THE U
<br />NIT, UNLESS OTHERWISE INDICATED. THE U-VALUE FOR THE IGU SHALL BE NO
<br />GREATER THAN 0.34, UNLESS OTHERWISE INDICATED.
<br />H. OBSCURE GLASS: TYPE II (PATTERNED), CLASS 1 (CLEAR), FORM 3 (PATTERNED),
<br />QUALITY Q7 (DECORATIVE), PATTERNED ONE SIDE, PATTERN AS INDICATED OR S
<br />ELECTED.
<br />I. THERMOPLASTIC GLAZING: POLYCARBONATE SHEET SHALL BE ULTRA-VIOLET
<br />STABILIZED MATERIAL, CLEAR OR GLARE REDUCING AS INDICATED, 1/4 INCH THICK A
<br />AS MANUFACTURED BY GENERAL ELECTRIC COMPANY “LEXAN”, DUPONT, OR E
<br />EQUAL. GLARE REDUCING GLAZING SHALL BE GRAY IN COLOR, PROVIDING A LIGHT
<br />TRANSMISSION OF 14 PERCENT.
<br />2.03 GLASS SETTING MATERIALS
<br />A. SETTING BLOCKS: ASTM C864, CHANNEL SHAPE; HAVING ¼ INCH INTERNAL DEPTH, S
<br />SHORE A HARDNESS OF 80 TO 90 DUROMETER. BLOCKS SHALL BE A MINIMUM 2
<br />INCH LONG. BLOCK WIDTH SHALL BE APPROXIMATELY 1/16 INCH LESS THAN THE
<br />FULL WIDTH OF THE RABBET. BLOCK THICKNESS SHALL BE AT LEAST 3/16 INCH,
<br />SIZED FOR RABBET DEPTH AS REQUIRED.
<br />B. SPACERS: ASTM C864, CHANNEL SHAPE, WITH ¼ INCH INTERNAL DEPTH, 3/32 INCH
<br />FLANGES, EB, 1/8 INCH THICK, ONE TO 3 INCHES LONG. SPACERS SHALL PROVIDE
<br />SHORE A HARDNESS OF 40 TO 50 DUROMETER.
<br />C. VINYL GLAZING CHANNELS: PROFILE COMPATIBLE WITH FRAMING SYSTEM AND
<br />DESIGNED TO ACCOMMODATE GLASS OF SPECIFIED THICKNESS, LIGHT GRAY IN
<br />COLOR. PROVIDE FOR DRY GLAZING ALUMINUM FRAMES WHERE INDICATED OR
<br />PERMITTED.
<br />D. GLAZING TAPE: POLY-ISOBUTYLENE BASED SEALANT TAPE, CONFORMING TO AAMA
<br />804.1, WITH ADHESIVE ONE SIDE PROTECTED BY TEMPORARY PAPER COVER,
<br />EXTRU-SEAL MANUFACTURED BY PECORA CORP., NO. 303 BY PROTECTIVE
<br />TREATMENTS, INC., OR EQUAL.
<br />E. SPRING STEEL SPACERS: GALVANIZED STEEL WIRE OR STRIP DESIGNED TO
<br />POSITION GLAZING IN CHANNEL OR RABBET SASH WITH STOPS.
<br />F. GLAZING CLIPS: GALVANIZED STEEL SPRING WIRE DESIGNED TO HOLD GLASS IN
<br />POSITION IN RABBET SASH WITHOUT STOPS.
<br />G. GLAZING POINTS (SPRIGS): PURE ZINC STOCK, THIN, FLAT, TRIANGULAR OR D
<br />IAMOND-SHAPED PIECES, 1/4 INCH MINIMUM SIZE.
<br />H. GLAZING SEALANTS FOR METAL SASH: GE SILICONES SILGLAZE II 2800, GE
<br />SILICONES SILPRUF, GE SILICONES 1200 SILICONE, AND DOW CORNING 999A.
<br />POLYBUTYLENE, OLEORESINOUS, ASPHALT, AND OIL BASE SEALANTS ARE N
<br />NOT PERMITTED. PROVIDE SEALANT OF SAME COLOR AS STRUCTURAL SILICONE
<br />SEALANT UNLESS OTHERWISE REQUIRED.
<br />I. GLAZING COMPOUND FOR WOOD SASH: PROVIDE ACRYLIC LATEX GLAZING
<br />COMPOUND FOR BEDDING AND SEALING GLASS IN WOOD FRAMES
<br />J. GLAZING COMPOUNDS AND SEALANTS FOR THERMOPLASTIC: PROVIDE SILICONE,
<br />BUTYL, OR POLYSULFIDE GLAZING COMPOUND.
<br />2.04 SPEAK HOLES
<br />A. SPEAK HOLES SHALL BE STOCK NO. 444, 4 TO 6-INCH DIAMETER FOR 1/4-INCH T
<br />TEMPERED FLOAT GLASS, STAINLESS STEEL AS MANUFACTURED BY NISSEN AND
<br />CO., N666 BY C.R. LAURENCE CO., OR EQUAL.
<br />PART 3 - EXECUTION
<br />3.01 TOLERANCES
<br />A. THICKNESS INDICATED OR SPECIFIED ARE NOMINAL WITHIN STANDARD
<br />TOLERANCES. MAXIMUM SIZE OF VERTICAL PANES SHALL NOT EXCEED THE
<br />FOLLOWING:
<br />FLOAT THICKNESS: 1/8 INCH 3/16 INCH 1/4 INCH
<br />MAXIMUM AREAS IN SQUARE FEET: 12 16 20
<br />WHEN EXCEEDING THESE SQUARE FOOT MEASUREMENTS GLASS IS TO BE SAFETY
<br />GLAZED.
<br />3.02 INSTALLATION, GENERAL
<br />A. GLAZED CABINET DOORS, WINDOWS, TRANSOMS, AND FIXTURES, NOT OTHERWISE
<br />NOTED OR INDICATED, SHALL BE GLAZED WITH CLEAR FLOAT GLASS. ROOM OR
<br />ENTRANCE DOORS SHALL BE GLAZED WITH CLEAR WIRE GLASS.
<br />B. OBSCURE GLASS IN EXTERIOR OPENINGS SHALL BE INSTALLED WITH SMOOTH SIDE
<br />OF GLASS TO WEATHER. PATTERNED GLASS SHALL BE INSTALLED WITH PATTERN R
<br />RUNNING VERTICALLY, UNLESS OTHERWISE INDICATED.
<br />C. GLAZING TAPES OR SEALANTS SHALL BE INSTALLED WHEREVER GLASS CONTACTS
<br />WOOD OR METAL SURFACES. WIDTH OF STRIPS SHALL BE AS REQUIRED.
<br />D. GLAZING COMPOUND SHALL BE NEATLY AND CLEANLY INSTALLED IN STRAIGHT
<br />LINES, EVEN WITH INSIDE EDGE OF SASH MEMBERS. THUMB PUTTYING IS NOT
<br />PERMITTED.
<br />E. DISPLAY CASES AND SLIDING GLASS DOORS IN CASEWORK: GLASS IN DISPLAY
<br />CASES SHALL BE ¼ INCH CLEAR LAMINATED GLASS AS INDICATED. EDGES OF
<br />GLASS SHALL BE ROUNDED AND POLISHED.
<br />F. GLAZING ALUMINUM SASH: GLAZING MATERIAL IN ALUMINUM SASH SHALL BE
<br />INSTALLED IN COMPOUND AND SECURED IN PLACE WITH ALUMINUM GLAZING
<br />BEADS. IN ADDITION, HORIZONTAL BEADS SHALL BE INSTALLED WITH 6-INCH BY 1
<br />INCH, TYPE A, SELF-TAPPING, STAINLESS STEEL, PHILLIPS-HEAD SCREWS,
<br />INSTALLED INTO PRE-DRILLED, COUNTER-SUNK HOLES AND SPACED 2 INCHES FROM
<br />EACH END AND 9 INCHES ON CENTERS.
<br />3.03 INSTALLATION OF GLASS
<br />A. CONFORM TO REQUIREMENTS OF GANA GLAZING MANUAL.
<br />B. PROVIDE EDGE BLOCKING TO COMPLY WITH REQUIREMENTS OF REFERENCED G
<br />GLAZING STANDARD, EXCEPT WHERE OTHERWISE REQUIRED BY GLASS UNIT
<br />MANUFACTURER.
<br />C. PROVIDE COMPRESSIBLE FILLER RODS OR EQUIVALENT BACK-UP MATERIAL TO
<br />PREVENT SEALANT FROM EXTRUDING INTO GLASS CHANNEL WEEP SYSTEMS, FROM
<br />ADHERING TO BACK SURFACE OF JOINTS AND TO CONTROL DEPTH OF SEALANT
<br />FOR OPTIMUM PERFORMANCE.
<br />D. FORCE SEALANTS INTO GLAZING CHANNELS, IN MANNER TO ELIMINATE VOIDS AND
<br />TO ENSURE COMPLETE BOND OF SEALANT TO GLASS AND CHANNEL SURFACES.
<br />E. TOOL EXPOSED SURFACES OF SEALANTS TO PROVIDE FOR DRAINAGE AWAY FROM
<br />GLASS. INSTALL PRESSURIZED TAPES AND GASKETS TO PROTRUDE SLIGHTLY OUT
<br />OF CHANNEL TO ELIMINATE DIRT AND MOISTURE POCKETS.
<br />F. WHERE DRY GLAZING OF ALUMINUM FRAME IS INDICATED OR PERMITTED, PROVIDE
<br />VINYL GLAZING CHANNELS INSTALLED IN ACCORDANCE WITH FRAME
<br />MANUFACTURERS WRITTEN RECOMMENDATIONS. DO NOT STRETCH CHANNELS.
<br />MITER CORNERS.
<br />G. FOR TAPE GLAZING, FURNISH TAPE OF THICKNESS TO PROVIDE APPROXIMATELY 30
<br />PERCENT COMPRESSION. CUT TAPE TO PROPER LENGTH AND INSTALL TO
<br />PERMANENT STOPS, THE ENTIRE LENGTH OF THE HEAD AND SILL FIRST, THEN TO J
<br />JAMBS. BUTT TAPE TOGETHER WITH NO OVERLAP AND REMOVE PAPER BACKING.
<br />INSTALL GLASS ON SETTING BLOCKS AT QUARTER POINTS AND MAINTAIN UNIFORM
<br />GLASS EDGE CLEARANCE AROUND ENTIRE PERIMETER OF GLASS. MAINTAIN
<br />MANUFACTURER'S RECOMMENDED EDGE CLEARANCE AND BITE ON GLASS.
<br />INSTALL GLASS FIRMLY INTO TAPE WITH A SLIGHT LATERAL MOVEMENT TO ASSURE
<br />PROPER ADHESION. INSTALL TAPE TO REMOVABLE STOP WITH EVENLY
<br />DISTRIBUTED FIRMNESS, SMOOTHING OUT WRINKLES IN TAPE. SECURE REMOVABLE
<br />STOP IN PROPER POSITION SO TAPE MAKES CONTACT WITH GLASS AS STOP IS INSTALLED,
<br />FORCING CONTACT WITH GLASS AND COMPLETELY SEALING JOINT. REMOVE EXCESS TAPE
<br />FROM BOTH SIDES AT SLIGHT ANGLE OVER SIGHT LINE. DO NOT UNDERCUT.
<br />H. GLASS IN WOOD FRAMES: INSTALL GLASS WITH GLAZING POINTS AND SETTING
<br />BLOCKS AS REQUIRED. SEAL GLASS WITH GLAZING COMPOUND AND SECURE WITH
<br />WOOD STOPS. INSTALL STOPS WITH FINE FINISHING NAILS, AND SET FOR PUTTY
<br />STOPPING.
<br />I. PATTERNED GLASS: INSTALL GLASS WITH ONE PATTERNED SMOOTH SURFACE ON
<br />THE WEATHER SIDE.
<br />J. LAMINATED GLASS: SASHES, WHICH ARE TO RECEIVE LAMINATED GLASS, SHALL BE
<br />WEEPED TO THE OUTSIDE TO PERMIT WATER IN THE CHANNEL TO DRAIN FROM THE
<br />FRAME.
<br />3.04 PROTECTION AND CLEANING
<br />A. PROTECT EXTERIOR GLASS FROM BREAKAGE BY FURNISHING CROSSED STREAMERS
<br />ATTACHED TO FRAMING AND AWAY FROM GLASS SURFACE. DO NOT DIRECTLY INSTALL
<br />MARKERS TO GLASS SURFACES. REMOVE NON-PERMANENT LABELS AND CLEAN
<br />SURFACES.
<br />B. PROTECT GLASS FROM CONTACT WITH CONTAMINATING SUBSTANCES RESULTING
<br />FROM CONSTRUCTION OPERATIONS. IF, DESPITE SUCH PROTECTION,
<br />CONTAMINATING SUBSTANCES DO COME INTO CONTACT WITH GLASS, REMOVE
<br />IMMEDIATELY BY METHOD RECOMMENDED BY GLASS MANUFACTURER.
<br />C. EXAMINE GLASS SURFACES ADJACENT TO OR BELOW EXTERIOR CONCRETE AND
<br />OTHER MASONRY SURFACES AT FREQUENT INTERVALS DURING CONSTRUCTION,
<br />BUT NOT LESS OFTEN THAN ONCE A MONTH, FOR BUILD-UP OF DIRT, SCUM, ALKALI
<br />DEPOSITS OR STAINING. WHEN EXAMINATION REVEALS PRESENCE OF THESE
<br />FORMS OF RESIDUE, REMOVE BY METHOD RECOMMENDED BY GLASS
<br />MANUFACTURER. GLAZING, WHICH CANNOT BE CLEANED TO A REQUIRED
<br />CONDITION, SHALL BE DEEMED DEFECTIVE WORK.
<br />D. REMOVE AND REPLACE GLASS, WHICH IS BROKEN, CHIPPED, CRACKED, ABRADED,
<br />OR DAMAGED DURING CONSTRUCTION.
<br />E. REMOVE PROTECTIVE COVERING FROM THERMOPLASTIC NOT MORE THAN 4 DAYS
<br />BEFORE SUBSTANTIAL COMPLETION, AND IMMEDIATELY BEFORE
<br />CLEANING. METHODS OF FINAL CLEANING AND FINISHING SHALL BE AS PRESCRIBED
<br />BY THERMOPLASTIC GLAZING PUBLICATIONS REFERENCED ABOVE.
<br />F. WASH GLASS ON BOTH FACES NOT MORE THAN FOUR DAYS BEFORE SUBSTANTIAL
<br />COMPLETION. WASH GLASS BY METHOD RECOMMENDED BY GLASS
<br />MANUFACTURER. DO NOT FURNISH HARSH CLEANING AGENTS, CAUSTICS,
<br />ABRASIVES, OR ACIDS FOR CLEANING. POLISH GLASS BOTH SIDES AND LEAVE FREE
<br />OF SOIL, STREAKS, AND LABELS.
<br />3.05 CLEAN UP
<br />A. REMOVE RUBBISH, DEBRIS AND WASTE MATERIALS AND LEGALLY DISPOSE OF OFF
<br />THE PROJECT SITE.
<br />3.06 PROTECTION
<br />A. PROTECT THE WORK OF THIS SECTION UNTIL SUBSTANTIAL COMPLETION.
<br />END OF SECTION
<br />R
<br />No.
<br />F
<br />LICENSE
<br />STATE
<br />D
<br />O
<br />A RCHITECT
<br />C AL IFORNIA
<br />STEPHE WHITE
<br />RENEWAL
<br />DATE
<br />C-34829
<br />N
<br />08/31/27
<br />SHEET TITLE
<br />PROJECT
<br />FACILITY
<br />FAC NO: BLDG NO: FLOOR LEV: SECTION:
<br />KP PROJ. NO.
<br />PERMIT NO.
<br />555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA
<br />ARCHITECT
<br />CONSULTANT
<br />ARCHITECT SEAL CONSULTANT SEAL
<br />KAISER FOUNDATION HOSPITALS
<br />NATIONAL FACILITIES SERVICES
<br />1800 HARRISON STREET OAKLAND,
<br />CALIFORNIA 94612
<br />ISSUE / REVISION LOG
<br />NO. ISSUED DATE
<br />0
<br />5'
<br />
<br />5
<br />0
<br />'
<br />GR
<br />A
<br />P
<br />H
<br />I
<br />C
<br />
<br />S
<br />C
<br />A
<br />L
<br />E
<br />S
<br />:
<br />
<br />1
<br />/
<br />1
<br />6
<br />"
<br />
<br />=
<br />
<br />1
<br />'
<br />-
<br />0
<br />"
<br />0
<br />25
<br />'
<br />1/
<br />8
<br />"
<br />
<br />=
<br />
<br />1
<br />'
<br />-
<br />0
<br />"
<br />5'
<br />0
<br />12
<br />'
<br />1/
<br />4
<br />"
<br />
<br />=
<br />
<br />1
<br />'
<br />-
<br />0
<br />"
<br />1'
<br />0
<br />6'
<br />1/
<br />2
<br />"
<br />
<br />=
<br />
<br />1
<br />'
<br />-
<br />0
<br />"
<br />1'
<br />0
<br />2'
<br />1-
<br />1
<br />/
<br />2
<br />"
<br />
<br />=
<br />
<br />1
<br />'
<br />-
<br />0
<br />"
<br />0
<br />1'
<br />3"
<br />
<br />=
<br />
<br />1
<br />'
<br />-
<br />0
<br />"
<br />IF
<br />
<br />T
<br />H
<br />I
<br />S
<br />
<br />S
<br />H
<br />E
<br />E
<br />T
<br />
<br />I
<br />S
<br />
<br />N
<br />O
<br />T
<br />
<br />30
<br />"
<br />x
<br />4
<br />2
<br />"
<br />,
<br />
<br />I
<br />T
<br />
<br />I
<br />S
<br />
<br />A
<br />
<br />R
<br />E
<br />D
<br />U
<br />C
<br />E
<br />D
<br />
<br />PR
<br />I
<br />N
<br />T
<br />
<br />-
<br />
<br />S
<br />C
<br />A
<br />L
<br />E
<br />
<br />AC
<br />C
<br />O
<br />R
<br />D
<br />I
<br />N
<br />G
<br />L
<br />Y
<br />AGENCY APPLICATION NUMBER
<br />AGENCY APPROVAL STAMP
<br />THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS
<br />NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION.
<br />HZ PROJ. NO.
<br />www.huitt-zollars.com
<br />Phone 310.820.4600 | Fax 310.207.4215
<br />C:
<br />\
<br />U
<br />s
<br />e
<br />r
<br />s
<br />\
<br />l
<br />r
<br />o
<br />b
<br />i
<br />n
<br />s
<br />o
<br />n
<br />\
<br />O
<br />n
<br />e
<br />D
<br />r
<br />i
<br />v
<br />e
<br />
<br />-
<br />
<br />H
<br />u
<br />i
<br />t
<br />t
<br />-
<br />Z
<br />o
<br />l
<br />l
<br />a
<br />r
<br />s
<br />,
<br />
<br />I
<br />n
<br />c
<br />\
<br />D
<br />o
<br />cu
<br />m
<br />e
<br />n
<br />t
<br />s
<br />\
<br />R
<br />3
<br />1
<br />4
<br />4
<br />1
<br />2
<br />.
<br />3
<br />5
<br />
<br />K
<br />P
<br />
<br />H
<br />B
<br />M
<br />
<br />K
<br />P
<br />O
<br />J
<br />_
<br />A
<br />2
<br />4
<br />_
<br />l
<br />r
<br />o
<br />b
<br />i
<br />n
<br />s
<br />o
<br />n
<br />L
<br />2
<br />M
<br />D
<br />X
<br />.
<br />r
<br />vt
<br />1
<br />1
<br />/
<br />3
<br />/
<br />2
<br />0
<br />2
<br />5
<br />
<br />3
<br />:
<br />4
<br />4
<br />:
<br />0
<br />1
<br />
<br />P
<br />M
<br />SOCC 2022 R HBM 1st Fl KPOJ
<br />REMODEL
<br />G0-02
<br />SPECIFICATIONS
<br />CA394-1 -
<br />CAP027721R314412.35
<br />HARBOR/MacARTHUR MEDICAL OFF
<br />3401 S. HARBOR BLVD.
<br />SANTA ANA, CALIFORNIA 92704
<br />N/ASPECIFICATIONS - DIVISION 6 CONT 06 N/ASPECIFICATIONS - DIVISION 7 07 N/ASPECIFICATIONS - DIVISION 8 08
<br />CITY SUBMITTAL 11/03/2025
<br />101125520, 20187249, 40140902
|