Laserfiche WebLink
SECTION 06 6116 - SOLID SURFACING FABRICATIONS <br />PART 1 - GENERAL <br />1.1 REFERENCES: <br />A. APPLICABLE STANDARDS: STANDARDS OF THE FOLLOWING, AS REFERENCED HEREIN: <br />1. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI). <br />2. ASTM INTERNATIONAL (ASTM). <br />1.2 ACTION SUBMITTALS: <br />A. SHOP DRAWINGS: INDICATE DIMENSIONS, COMPONENT SIZES, FABRICATION DETAILS <br />ATTACHMENT PROVISIONS AND COORDINATION REQUIREMENTS WITH ADJACENT <br />WORK. <br />B. SAMPLES: SUBMIT MINIMUM 6" BY 6" SAMPLES. INDICATE FULL RANGE OF COLOR AND <br />PATTERN VARIATION. APPROVED SAMPLES WILL BE RETAINED AS A STANDARD FOR WORK. <br />C. PRODUCT DATA: INDICATE PRODUCT DESCRIPTION, FABRICATION INFORMATION AND <br />COMPLIANCE WITH SPECIFIED PERFORMANCE REQUIREMENT. <br />1.3 CLOSEOUT SUBMITTALS: <br />A. MAINTENANCE DATA: SUBMIT MANUFACTURER'S CARE AND MAINTENANCE DATA, <br />INCLUDING REPAIR AND CLEANING INSTRUCTIONS. INCLUDE IN PROJECT CLOSEOUT <br />DOCUMENTS. <br />1.5 DELIVERY, STORAGE AND HANDLING: <br />A. DELIVER NO COMPONENTS TO PROJECT SITE UNTIL AREAS ARE READY FOR <br />INSTALLATION. STORE INDOORS. <br />B. HANDLE MATERIALS TO PREVENT DAMAGE TO FINISHED SURFACES. PROVIDE <br />PROTECTIVE COVERINGS TO PREVENT PHYSICAL DAMAGE OR STAINING FOLLOWING <br />INSTALLATION FOR DURATION OF PROJECT. <br />1.6 WARRANTY: <br />A. PROVIDE MANUFACTURER'S WARRANTY AGAINST DEFECTS IN MATERIALS. WARRANTY <br />SHALL PROVIDE FOR REPLACEMENT MATERIAL AND LABOR FOR A PERIOD OF FIVE <br />YEARS, BEGINNING AT DATE OF SUBSTANTIAL COMPLETION. <br />PART 2 - PRODUCTS <br />2.1 CAST ACRYLIC SURFACING MATERIAL: <br />A. ACCEPTABLE PRODUCTS: <br />1. SEE FINISH LIST FOR SPECIFIED PRODUCT <br />B. MATERIAL: CAST, 100% ACRYLIC RESIN, SOLID, STRUCTURAL SURFACING MATERIAL. <br />1. MATERIAL SHALL BE THROUGH-PATTERNED AND HOMOGENEOUS. NO <br />COATED MATERIALS NOR NON-HOMOGENEOUS MATERIALS ALLOWED. <br />2. HARDNESS: MINIMUM 55 BARCOL HARDNESS, TESTED IN ACCORD WITH ASTM <br />D2583-07, OR INIMUM 90 ROCKWELL HARDNESS, TESTED IN ACCORD WITH <br />ASTM D785-08. <br />3. TENSILE STRENGTH: MINIMUM 4,200 PSI, TESTED IN ACCORD WITH ASTM <br />D638-10. <br />4. ABRASION RESISTANCE: MAXIMUM 0.4 GRAMS AT 1,000 CYCLES, TESTED IN <br />ACCORD WITH ASTM C501-84(2009). <br />5. FIRE-RESISTANCE: FLAME SPREAD AND SMOKE DEVELOPED MEETING ASTM <br />E84-12C, CLASS I RATING. <br />6. COLOR STABILITY: NO CHANGE IN 200 HOURS, TESTED IN ACCORD WITH <br />NEMA LD3-2005. <br />7. WATER ABSORPTION: MAXIMUM 0.04% FOR 3/4" THICKNESS AND 0.06% FOR <br />1/2" THICKNESS, TESTED IN ACCORD WITH ASTM D570-98(2010). <br />8. FUNGAL RESISTANCE: NO ATTACK WHEN TESTED IN ACCORD WITH ASTM <br />G21-09. <br />9. BACTERIAL RESISTANCE: NO ATTACK WHEN TESTED IN ACCORD WITH ASTM <br />G22-76(1996)(WITHDRAWN 2002). <br />10. IMPACT RESISTANCE: NO FRACTURE WHEN TESTED IN ACCORD WITH NEMA <br />LD3-2005; SECTION 3.3, 144" DROP FOR 1/2" THICKNESS AND 204" DROP FOR <br />3/4" THICKNESS. <br />11. SUPERFICIAL DAMAGE TO A DEPTH OF 0.10" SHALL BE REPAIRABLE BY <br />SANDING AND POLISHING. <br />12. SURFACES SHALL BE UN AFFECTED BY CLASS I REAGENTS AND SHALL BE <br />REPAIRABLE AFTER EXPOSURE TO CLASS II REAGENTS. CLASS I AND II <br />REAGENTS SHALL BE AS IDENTIFIED IN BASIS OF DESIGN MANUFACTURER'S <br />PRODUCT DATA. <br />13. SURFACES AT DRUG COMPOUNDING COUNTER IN THE PHARMACY ARE TO BE <br />CHEMICAL RESISTANT. <br />C. FINISH: MATTE (GLOSS RATING OF 5-20). <br />D. COLOR: AS SELECTED BY ARCHITECT. <br />E. THICKNESS: AS INDICATED IN DRAWINGS. <br />2.2 ACCESSORY PRODUCTS: <br />A. JOINT ADHESIVE: MANUFACTURER'S STANDARD, TWO-PART ADHESIVE KIT TO CREATE <br />INCONSPICUOUS, NON-POROUS JOINTS, WITH A CHEMICAL BOND. <br />B. SEALANT: MANUFACTURER'S STANDARD MILDEW-RESISTANT, USDA/UL RECOGNIZED <br />SILICONE SEALANT IN COLOR MATCHING SURFACING OR CLEAR FORMULATIONS. <br />C. ADHESIVES AND SEALANTS VOC CONTENT: ADHESIVE AND SEALANTS SHALL HAVE A <br />VOC CONTENT LESS THAN THE CURRENT VOC CONTENT LIMITS OF SOUTH COAST <br />AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) RULE #1168, ADHESIVES AND <br />SEALANTS, AMENDED JANUARY 7, 2005. <br />2.3 FABRICATION: <br />A. FACTORY-FABRICATE COMPONENTS TO GREATEST EXTENT PRACTICABLE, TO SIZES <br />AND SHAPES INDICATED, IN ACCORD WITH APPROVED SHOP DRAWINGS. <br />B. FORM JOINTS BETWEEN COMPONENTS USING MANUFACTURER'S STANDARD JOINT <br />ADHESIVE; WITHOUT CONSPICUOUS JOINTS AND WITHOUT VOIDS. ATTACH A 2" WIDE <br />REINFORCING STRIP OF SOLID SURFACING UNDER EACH JOINT. <br />C. PROVIDE FACTORY CUTOUTS FOR PLUMBING FITTINGS AND ACCESSORIES AS INDICATED. <br />D. ROUT AND FINISH COMPONENT EDGES TO A SMOOTH, UNIFORM FINISH. ROUT CUTOUTS <br />AND SAND EDGES SMOOTH. MACHINE RADII AND CONTOURS TO TEMPLATE. REPAIR OR <br />REJECT DEFECTIVE AND INACCURATE WORK. <br />E. EDGE TREATMENT FOR TOPS: AS INDICATED ON DRAWINGS. <br />2.4 SOURCE QUALITY CONTROL: <br />A. ALLOWABLE TOLERANCES: <br />1. VARIATION IN COMPONENT SIZE: + -1/8". <br />2. LOCATION OF OPENINGS: + -1/8" FROM INDICATED LOCATION. <br />PART 3 - EXECUTION <br />3.1 INSTALLATION: <br />A. INSTALL COMPONENTS PLUMB, LEVEL AND RIGID, SCRIBED TO ADJACENT FINISHES, <br />IN ACCORD WITH APPROVED SHOP DRAWINGS AND PRODUCT DATA. <br />B. FORM FIELD JOINTS USING SPECIFIED ADHESIVE, WITH JOINTS INCONSPICUOUS IN <br />FINISHED WORK. <br />C. PROVIDE BACK AND END SPLASHES AS INDICATED. ADHERE TO COUNTERTOPS USING <br />SPECIFIED COLOR-MATCHED SILICONE ADHESIVE. <br />D. KEEP COMPONENTS CLEAN DURING INSTALLATION. REMOVE ADHESIVES, SEALANTS AND <br />OTHER STAINS. KEEP CLEAN UNTIL DATE OF SUBSTANTIAL COMPLETION. REPLACE <br />STAINED COMPONENTS. <br />E. MAKE PLUMBING CONNECTIONS TO SINKS IN ACCORD WITH DIVISION 22, PLUMBING. <br />3.2 PROTECTION: <br />A. PROTECT SURFACES FROM DAMAGE UNTIL DATE OF SUBSTANTIAL COMPLETION. REPAIR <br />OR REPLACE DAMAGED WORK WHICH CANNOT BE REPAIRED. <br />END OF SECTION <br />PART 3 - EXECUTION <br />3.1 EXAMINATION: <br />A. EXAMINE SUBSTRATES, AREAS, AND CONDITIONS WHERE INSTALLATION OF PLASTIC <br />FABRICATIONS WILL OCCUR, WITH INSTALLER PRESENT, FOR COMPLIANCE WITH <br />MANUFACTURER'S REQUIREMENTS. VERIFY THAT SUBSTRATES AND CONDITIONS ARE <br />SATISFACTORY FOR INSTALLATION AND COMPLY WITH REQUIREMENTS SPECIFIED. <br />3.2 INSTALLATION: <br />A. GENERAL: COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS FOR THE <br />INSTALLATION OF PLASTIC FABRICATIONS. <br />B. MANUFACTURER'S SHOP TO FABRICATE ITEMS TO THE GREATEST DEGREE POSSIBLE. <br />C. UTILIZE FASTENERS, ADHESIVES AND BONDING AGENTS RECOMMENDED BY <br />MANUFACTURER FOR TYPE OF INSTALLATION INDICATED. MATERIAL THAT IS CHIPPED, <br />WARPED, HAZED OR DISCOLORED AS A RESULT OF INSTALLATION OR FABRICATION <br />METHODS WILL BE REJECTED. <br />D. INSTALL COMPONENTS PLUMB, LEVEL AND RIGID, SCRIBED TO ADJACENT FINISHES, <br />IN ACCORDANCE WITH APPROVED SHOP DRAWINGS AND PRODUCT DATA. <br />E. FORM FIELD JOINTS MANUFACTURER'S RECOMMENDED PROCEDURES. LOCATE SEAMS <br />IN PANELS SO THAT THEY ARE NOT DIRECTLY IN LINE WITH SEAMS IN SUBSTRATES. <br />3.3 CLEANING AND PROTECTION: <br />A. PROTECT SURFACES FROM DAMAGE UNTIL DATE OF SUBSTANTIAL COMPLETION. <br />REPAIR <br />WORK OR REPLACE DAMAGED WORK, WHICH CANNOT BE REPAIRED TO ARCHITECT'S <br />SATISFACTION. <br />END OF SECTION <br />DIVISION 7 - THERMAL AND MOISTURE PROTECTION <br />SECTION 07 8400 - FIRESTOPPING <br />PART 1 - GENERAL <br />1.1 SUMMARY: <br />A. RELATED WORK: <br />1. GYPSUM BOARD. <br />2. PLUMBING. <br />3. ELECTRICAL. <br />1.2 SYSTEM PERFORMANCE REQUIREMENTS: <br />A. FIRESTOPPING SYSTEMS SHALL PROVIDE RESISTANCE TO SPREAD OF FIRE, AND <br />PASSAGE OF SMOKE AND OTHER GASES ACCORDING TO REQUIREMENTS INDICATED, <br />INCLUDING BUT NOT LIMITED TO THE FOLLOWING: <br />1. FIRESTOP PENETRATIONS PASSING THROUGH FIRE RESISTANCE RATED WALL <br />AND FLOOR ASSEMBLIES AND OTHER LOCATIONS AS INDICATED ON DRAWINGS. <br />2. PENETRATION FIRESTOPPING SYSTEMS SHALL HAVE BEEN TESTED AND <br />APPROVED BY A THIRD PARTY TESTING AGENCY. <br />3. THROUGH-PENETRATION FIRESTOP SYSTEMS AND DEVICES SHALL RESIST <br />SPREAD OF FIRE, AND PASSAGE OF SMOKE AND OTHER GASES ACCORDING <br />TO REQUIREMENTS INDICATED, INCLUDING BUT NOT LIMITED TO THE <br />FOLLOWING: <br />A. F - RATING SHALL EQUAL OR EXCEED THE RATING OF THE <br />FIRE-RESISTIVE CONSTRUCTION ASSEMBLY THROUGH WHICH THE <br />PENETRATION IS MADE, AS DETERMINED BY ASTM E814-11A, BUT <br />SHALL NOT BE NOT LESS THAN 1-HOUR. <br />B. T- RATING, IN ADDITION TO F-RATING, AT PENETRATIONS LOCATED <br />OUTSIDE OF A WALL CAVITY, SHALL EQUAL FIRE-RESISTIVE RATING <br />OF FLOOR CONSTRUCTION, AS DETERMINED BY ASTM E814-11A, <br />BUT SHALL BE NOT LESS THAN 1-HOUR. <br />C. L - RATING: IN ADDITION TO F AND T RATINGS, FIRESTOPPING SHALL <br />HAVE AN L - RATING, AS DETERMINED BY UL 1479, WHERE INDICATED <br />BY CODE. <br />4. FIRESTOP SYSTEMS USING CEMENTITIOUS FILL MATERIALS SHALL NOT BE <br />PERMITTED. <br />5. SYSTEMS USED WITHIN OR ADJACENT TO OCCUPIED SPACES SHALL BE FREE <br />OF VOLATILE SOLVENTS, NOXIOUS FUMES AND STRONG ODORS. <br />1.3 ACTION SUBMITTALS: <br />A. SHOP DRAWINGS: SUBMIT DETAILED DRAWINGS OF EACH TYPE AND SIZE PENETRATION <br />THROUGH FIRE-RATED CONSTRUCTION, INDICATING MATERIALS, DIMENSIONS, <br />ASSEMBLY CONSTRUCTION AND RATING. INDICATE THROUGH-PENETRATION FIRESTOP <br />SYSTEM DESIGN LISTINGS, INCLUDING ILLUSTRATIONS FROM A QUALIFIED TESTING AND <br />INSPECTION AGENCY FOR EACH TYPE PENETRATION. <br />B. PRODUCT DATA: SUBMIT PRODUCT DATA AND INSTALLATION INSTRUCTIONS FOR EACH <br />TYPE OF INSTALLATION. INCLUDE INSTALLATION DETAILS AND TEST REPORTS <br />INDICATING THAT FIRESTOPPING MATERIALS, SYSTEMS AND DEVICES MEET SPECIFIED <br />REQUIREMENTS AND DESIGN CRITERIA. INDICATE CLASSIFICATION MARKING OF <br />QUALIFIED TESTING AND INSPECTION AGENCY. <br />1.4 QUALITY ASSURANCE: <br />A. APPLICABLE STANDARDS; STANDARDS OF THE FOLLOWING, AS REFERENCED HEREIN: <br />1. ASTM INTERNATIONAL (ASTM). <br />2. FACTORY MUTUAL RESEARCH (FMR) <br />3. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA). <br />4. UNDERWRITERS LABORATORIES, INC. (UL). <br />B. FIRE-TEST-RESPONSE CHARACTERISTICS: PROVIDE FIRESTOPPING SYSTEM DESIGN <br />LISTING BY A TESTING AND INSPECTION AGENCY IN ACCORD WITH THE SPECIFIED <br />UL STANDARDS. <br />C. ACCEPTABLE INSTALLER SHALL BE: <br />1. INSTALLER QUALIFICATIONS: A FIRM THAT HAS BEEN APPROVED BY FM <br />GLOBAL ACCORDING TO FM GLOBAL 4991, "APPROVAL OF FIRESTOP <br />CONTRACTOR," OR BEEN EVALUATED BY UL AND FOUND TO COMPLY WITH <br />UL's "QUALIFIED FIRESTOP CONTRACTOR PROGRAM REQUIREMENTS." <br />2. LICENSED BY STATE OR LOCAL AUTHORITY, WHERE APPLICABLE. <br />D. SINGLE SOURCE RESPONSIBILITY: OBTAIN FIRESTOP SYSTEMS FOR EACH KIND OF <br />PENETRATION AND CONSTRUCTION CONDITION INDICATED FROM A SINGLE PRIMARY <br />FIRESTOP SYSTEMS MANUFACTURER. <br />1. MATERIALS FROM DIFFERENT MANUFACTURER THAN ALLOWED BY TESTED <br />AND LISTED SYSTEM SHALL NOT BE INTERMIXED IN THE SAME FIRESTOP <br />SYSTEM OR OPENING. <br />2. INSTALL TESTED AND LISTED FIRESTOP SYSTEMS BEFORE INSTALLING AN <br />ENGINEERING JUDGEMENT OR EQUIVALENT FIRE RESISTANCE RATED <br />ASSEMBLY (EFFRA). <br />E. SECURE INSPECTION AND APPROVAL OF FIRESTOPPING WORK BY BUILDING OFFICIALS <br />PRIOR TO CONCEALMENT. <br />F. SUPPORT PENETRATING ELEMENTS INDEPENDENTLY OF FIRESTOPPING SYSTEMS OR <br />DEVICES. <br />G. DO NOT COVER UP FIRESTOPPING INSTALLATIONS UNTIL OWNER'S INSPECTION AGENCY <br />OR AUTHORITIES HAVING JURISDICTION HAVE EXAMINED EACH INSTALLATION. <br />PART 2 - PRODUCTS <br />2.1 MATERIALS, GENERAL: <br />A. VOC CONTENT: PENETRATION FIRESTOPPING SEALANTS AND SEALANT PRIMERS SHALL <br />HAVE A VOC CONTENT LESS THAN THE CURRENT VOC CONTENT LIMITS OF SOUTH <br />COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) RULE #1113, ARCHITECTURAL <br />COATINGS, RULES IN EFFECT JANUARY 1, 2004. <br />2.2 THROUGH-PENETRATION FIRESTOP SYSTEMS: <br />A. ACCEPTABLE MANUFACTURERS; SUBJECT TO COMPLIANCE WITH SPECIFIED <br />REQUIREMENTS: <br />1. HILTI USA. <br />2. 3M FIRE PROTECTION PRODUCTS. <br />3. SPECIFIED TECHNOLOGIES, INC. (STI). <br />PART 3 - EXECUTION <br />3.1 EXAMINATION: <br />A. EXAMINE AREAS TO RECEIVE FIRESTOPPING MATERIALS PRIOR TO BEGINNING WORK. <br />VERIFY THAT OPENING AREAS AND DIMENSIONS FOR PENETRATIONS TO RECEIVE <br />FIRESTOPPING SYSTEMS AND DEVICES DO NOT EXCEED DESIGN REQUIREMENTS. <br />B. REMOVE PROJECTIONS INTERFERING WITH INSTALLATION. PREPARE SURFACES IN <br />ACCORD WITH MANUFACTURER'S PRODUCT DATA AND UL THROUGH-PENETRATION <br />FIRESTOP DEVICES NUMBERS. <br />3.2 PREPARATION: <br />A. PRIMING: PRIME SUBSTRATES WHERE RECOMMENDED BY FIRESTOPPING MANUFACTURER <br />USING THAT MANUFACTURER'S RECOMMENDED PRODUCTS AND METHODS. CONFINE <br />PRIMERS TO AREAS OF BOND. DO NOT ALLOW SPILLAGE AND MIGRATION ONTO EXPOSED <br />SURFACES. <br />B. MASKING TAPE: USE MASKING TAPE TO PREVENT FIRESTOPPING FROM CONTACTING <br />ADJOINING SURFACES THAT WILL REMAIN EXPOSED UPON COMPLETION OF THE WORK. <br />REMOVE TAPE AS SOON AS IT IS POSSIBLE TO DO SO WITHOUT DISTURBING THE <br />FIRESTOPPING SEAL WITH SUBSTRATES. <br />3.3 INSTALLATION: <br />A. GENERAL: <br />1. COMPLY WITH MANUFACTURER'S PRODUCT DATA AND UL CLASSIFIED FOR <br />THROUGH-PENETRATION FIRESTOP DEVICES NUMBERS. <br />2. INSTALL FIRESTOPPING MATERIALS FITTED TO ADJACENT CONSTRUCTION <br />TO FILL VOIDS. <br />3. FIRESTOP PENETRATIONS THROUGH FIRE-RATED WALLS, PARTITIONS, FLOORS <br />AND FLOOR/CEILING ASSEMBLIES WITH TESTED ASSEMBLIES IN ACCORD WITH <br />UL 1479 OR WITH A THROUGH-PENETRATION FIRESTOP SYSTEM OR DEVICE <br />WHEN TESTED IN ACCORD WITH ASTM E814-11A. <br />4. FIRESTOPPING SHALL COMPLY WITH CODE REQUIREMENTS. <br />B. THROUGH-PENETRATION FIRESTOP SYSTEMS AND DEVICES: <br />1. INSTALL AT PENETRATIONS THROUGH FIRE-RATED FLOOR AND WALL <br />CONSTRUCTION, INCLUDING PARTITIONS AND FLOOR/ CEILING ASSEMBLIES, <br />IN ACCORD WITH MANUFACTURER'S PRODUCT DATA AND UL SYSTEM NUMBERS. <br />PROVIDE MATERIALS AND ACCESSORIES AS REQUIRED. <br />2. INSTALL INTUMESCENT TYPE FIRESTOP SYSTEMS WHERE PLASTIC PIPING, <br />CABLE, CONDUIT AND OTHER COMBUSTIBLE ITEMS, INCLUDING INSULATED <br />METAL PIPES, PENETRATE FIRE-RATED CONSTRUCTION. <br />3. AT CONTRACTOR'S OPTION, THROUGH-PENETRATION FIRESTOP DEVICES OF <br />SIMILAR FUNCTION MAY BE INSTALLED IN LIEU OF FIRESTOP SYSTEMS. <br />4. DO NOT REMOVE FORMING MATERIALS UNLESS SPECIFIED IN SYSTEM DESIGNS. <br />C. FIRESTOP SEALANT: SEAL PERIMETERS, VOIDS AND JOINTS OF FIRE-RATED WALLS AND <br />PARTITIONS,INCLUDING ABUTMENT OF FLOOR AND ROOF OR CEILING STRUCTURE, AND <br />FLUTES OF METAL DECKING. <br />1. IF REQUIRED BY UL DESIGN, INSTALL MINERAL WOOL OR CERAMIC FIBER IN <br />CAVITIES, PACKED FULL AND TIGHT WITH ALLOWANCE FOR SEALANT <br />INSTALLATION. <br />2. SEAL BOTH FACES OF WALLS AND PARTITIONS WITH FIRESTOP SEALANT. TOOL <br />SEALANTFLUSH WITH ADJACENT FINISH. <br />3. IN ACCORD WITH UL FIRE RESISTANCE DIRECTORY DESIGNS, PACKED CONCRETE <br />AND MASONRY JOINTS SHALL BE SEALED USING FIRESTOP SEALANT OR USING <br />SEALANT AS SPECIFIED IN JOINT SEALANTS SECTION. <br />D. MINERAL FIBER SAFING: <br />1. INSTALL SAFING IN CAVITIES OF PENETRATIONS THROUGH NON-RATED FLOOR <br />AND WALL CONSTRUCTION, INCLUDING SPACES AROUND PIPING, CONDUITS, <br />CABLES AND DUCT PENETRATIONS. <br />2. INSTALL SAFING IN VOIDS AND JOINTS OF NON-RATED WALLS AND PARTITIONS <br />ABUTTING METAL DECKING OF FLOOR AND ROOD STRUCTURES. PACK FLUTES <br />OF METAL DECKING SOLID WITH SAFING MATERIAL. <br />3. SAFING SHALL BE INSTALLED AT JOINTS AND PENETRATIONS IN NON-RATED <br />CONSTRUCTION NOT EXPOSED TO VIEW AND CONCEALED IN FINISH WORK. <br />SECURE SAFING BY COMPRESSING INTO VOIDS OR JOINTS AND USING <br />MANUFACTURER'S STANDARD CLIPS OR CLOSURE PLATES AS REQUIRED. <br />3.4 CLEANING: <br />A. CLEAN OFF EXCESS FILL MATERIALS AND SEALANTS ADJACENT TO OPENINGS AND <br />JOINTS AS WORK PROGRESSES. USE METHODS AND CLEANING MATERIALS APPROVED <br />BY MANUFACTURERS OF FIRESTOPPING PRODUCTS AND OR ASSEMBLIES IN WHICH <br />OPENINGS AND JOINTS OCCUR. <br />B. PROTECT FIRESTOPPING DURING AND AFTER CURING PERIOD FROM CONTACT WITH <br />CONTAMINATING SUBSTANCES. <br />END OF SECTION <br />DIVISION 8 - OPENINGS <br />SECTION 08 1113 <br />HOLLOW METAL FRAMES <br />PART 1 - GENERAL <br />1.01 SUMMARY <br />A. SECTION INCLUDES: <br />1. HOLLOW METAL DOORS AND FRAMES OR HOLLOW METAL DOORS AS INDICATED. <br />2. HOLLOW METAL WINDOW FRAMES OR HOLLOW METAL DOOR AND WINDOW FRAMES. <br />1.02 DESIGN REQUIREMENTS <br />A. DOOR-AND-FRAME ASSEMBLIES OR FRAMES SHALL INCLUDE REINFORCING AND PROVISIONS <br />FOR HARDWARE AS SHOWN AND SPECIFIED. DRAWINGS INDICATE PROFILE AND GENERAL <br />DETAILS OF STEEL FRAME FABRICATION AND INSTALLATION. <br />1.03 SUBMITTALS <br />A. SHOP DRAWINGS: SUBMIT COMPOSITE SHOP DRAWINGS INDICATING DETAILED <br />RELATIONSHIPS OF INSTALLATION INCLUDING WORK OF ADJACENT CONSTRUCTION, FINISH <br />HARDWARE, SECURITY, FIRE AND LIFE SAFETY DEVICES, GLAZING, SEALING, AND <br />REQUIREMENTS FOR FIELD INSTALLATION. INCLUDE ELEVATIONS OF EACH HOLLOW METAL <br />DOOR TYPE, DETAILS OF EACH FRAME TYPE, LOCATION SCHEDULE OF DOORS AND FRAMES <br />INDICATING SAME REFERENCE FOR DETAILS AND OPENINGS AS INDICATED ON DRAWINGS, <br />CONDITIONS OF OPENINGS OF VARIOUS WALL SECTIONS AND MATERIALS, TYPICAL AND <br />SPECIAL DETAILS OF CONSTRUCTION, METHODS OF ASSEMBLING SECTIONS, LOCATION AND <br />INSTALLATION REQUIREMENTS FOR HARDWARE, MATERIAL SIZE, SHAPE, AND THICKNESS, AND <br />JOINTS AND CONNECTIONS. <br />B. PRODUCT DATA: SUBMIT MANUFACTURER'S PRODUCT DATA INDICATING COMPOSITION AND <br />CONSTRUCTION FOR EACH FABRICATED ITEM INCLUDING LOUVERS, COATINGS, FINISHES, AND <br />OTHER COMPONENTS DEMONSTRATING COMPLIANCE WITH REFERENCED STANDARDS. <br />C. CERTIFICATION: SUBMIT CERTIFICATION OF COMPLIANCE WITH REFERENCED STANDARDS <br />AND SPECIFIED CRITERIA, INCLUDING BUT NOT LIMITED TO FIRE RATINGS IN ACCORDANCE <br />WITH UL 10C, PHYSICAL ENDURANCE IN ACCORDANCE WITH ANSI A250.4 AND PRIME PAINT <br />PERFORMANCE IN ACCORDANCE WITH ANSI A250.10.. <br />1.04 QUALITY ASSURANCE <br />A. MANUFACTURER QUALIFICATIONS: MINIMUM DOCUMENTED EXPERIENCE OF MORE THAN <br />FIVE YEARS IN WORK OF THIS SECTION. <br />B. INSTALLER QUALIFICATIONS: MINIMUM DOCUMENTED EXPERIENCE OF MORE THAN FIVE <br />YEARS IN WORK OF THIS SECTION <br />C. COORDINATE WITH HARDWARE SUPPLIER FOR FABRICATION OF DOORS AND FRAMES TO <br />RECEIVE HARDWARE ITEMS. <br />D. REFERENCES: WORK SHALL COMPLY WITH PHYSICAL AND PERFORMANCE REQUIREMENTS <br />OF FOLLOWING STANDARDS, INCLUDING STANDARDS REFERENCED IN THEM, EXCEPT FOR <br />MORE STRINGENT PROVISIONS SPECIFIED HEREIN OR REQUIRED BY REGULATORY AGENCIES: <br />1. ANSI/SDI A250.8, SDI 100 RECOMMENDED SPECIFICATIONS FOR STANDARD STEEL <br />DOORS AND FAMES. <br />2. HMMA, GUIDE SPECIFICATIONS FOR COMMERCIAL HOLLOW METAL DOORS & <br />FRAMES (STANDARD OF NATIONAL ASSOCIATION OF ARCHITECTURAL METAL <br />MANUFACTURERS). <br />3. ANSI/SDI A250.4, TEST PROCEDURE AND ACCEPTANCE CRITERIA FOR PHYSICAL <br />ENDURANCE FOR STEEL DOORS, FRAMES, FRAME ANCHORS AND HARDWARE <br />REINFORCINGS. <br />4. ANSI A250.10, TEST PROCEDURE AND ACCEPTANCE CRITERIA FOR PRIME PAINTED <br />STEEL DOORS AND FRAMES. <br />5. ANSI A250.6, RECOMMENDED PRACTICE FOR HARDWARE REINFORCING ON <br />STANDARD STEEL DOORS AND FRAMES. <br />E. STANDARDS OF FABRICATION AND INSTALLATION: <br />1. FINISHED WORK SHALL BE OF UNIFORM PROFILE, ACCURATELY FABRICATED, RIGID <br />AND STRONG, SQUARE AND TRUE, NEAT IN APPEARANCE, SMOOTH AND FREE FROM <br />DENTS, WAVES, WARPS, BUCKLES, OPEN JOINTS, TOOL MARKS AND/OR OTHER <br />DEFECTS. <br />2. STEEL SHEET SHALL BE CLEAN WITH SMOOTH SURFACES FREE OF SCALE, PITTING <br />OR OTHER DEFECTS. <br />3. CONSTRUCTION JOINTS SHALL BE FLUSH, TIGHT AND WELDED THEIR FULL LENGTH, <br />GROUND FLUSH AND SMOOTH ON EXPOSED SURFACES. <br />4. FRAME AND DOOR REINFORCING AND HARDWARE PROVISIONS SHALL BE <br />PERFORMED IN FABRICATION SHOP. PROVIDE CUTS, WELDS, AND OTHER <br />FABRICATIONS BEFORE GALVANIZING OR SHOP PRIMING. <br />5. LINES AND MOLDED MEMBERS SHALL BE STRAIGHT AND TRUE WITH ANGLES AS <br />SHARP AS PRACTICAL FOR THICKNESS INVOLVED, SURFACES FLAT, AND FASTENINGS <br />CONCEALED. <br />1.05 WARRANTY <br />A. MANUFACTURER SHALL PROVIDE A FIVE YEAR MATERIAL WARRANTY. <br />B. INSTALLER SHALL PROVIDE A TWO YEAR FABRICATION AND INSTALLATION WARRANTY. <br />PART 2 - PRODUCTS <br />2.01 MANUFACTURERS <br />A. FRAMES SHALL BE PRODUCTS OF A SINGLE MANUFACTURER. <br />B. THE FOLLOWING ARE ACCEPTABLE MANUFACTURERS, AS ARE OTHERS THAT CAN <br />DEMONSTRATE THEIR PRODUCTS ARE EQUIVALENT IN QUALITY, PERFORMANCE AND <br />COMPLIANCE WITH THESE SPECIFICATIONS. <br />1. SECURITY METAL PRODUCTS CORP. <br />2. CURRIES MANUFACTURING, INC. <br />3. STEELCRAFT. <br />4. AMWELD METAL DOORS AND FRAMES. <br />5. STILES CUSTOM METAL, INC. <br />6. DOOR COMPONENTS INC. <br />7. CECO DOOR. <br />8. EQUAL. <br />C. MATERIALS, FABRICATION AND INSTALLATION MUST COMPLY WITH REQUIREMENTS OF <br />STANDARDS REFERENCED IN SECTION 1.04, QUALITY ASSURANCE. <br />2.02 MATERIALS <br />A. STEEL: <br />1. INTERIOR DOORS AND FRAMES: COLD-ROLLED STEEL SHEETS, COMMERCIAL <br />QUALITY CARBON STEEL, ASTM A1008. <br />2. STEEL SHALL BE FREE OF SCALE, PITTING, COIL BREAKS OR OTHER SURFACE <br />BLEMISHES, AND FREE OF BUCKLES, WAVES OR OTHER DEFECTS. <br />3. STEEL THICKNESSES EXPRESSED IN STEEL GAGES (MSG) IS FOR REFERENCE ONLY. <br />ACTUAL STEEL THICKNESSES MUST MEET MINIMUM REQUIREMENTS OF ASTM <br />STANDARDS AND AS DESCRIBED IN ANSI/SDI A250.8. <br />B. SUPPORTS AND ANCHORS: FABRICATE FROM A MINIMUM 16 GAUGE GALVANIZED SHEET <br />STEEL UNLESS NOTED OTHERWISE. <br />C. FASTENERS: PROVIDE AS SHOWN ON DRAWINGS AND TO SUIT CONDITIONS OF SECURE <br />INSTALLATIONS. <br />D. SHOP PAINT: <br />1. CONFORM TO STEEL STRUCTURES PAINTING COUNCIL (SSPC) FOR STEEL <br />COMPONENTS. <br />2. PRETREATMENT/PRIMING COATINGS SHALL BE COMPATIBLE WITH PROJECT SITE <br />FINISH PAINTING SYSTEM IN ACCORDANCE WITH SECTION 09 9000. <br />2.03 FABRICATION GENERAL <br />A.GENERAL: FABRICATE HOLLOW METAL UNITS TO BE RIGID, NEAT IN APPEARANCE, AND FREE <br />FROM DEFECTS INCLUDING WARP OR BUCKLE. <br />1. ACCURATELY FORM METAL TO REQUIRED SIZES AND PROFILES. FIT AND ASSEMBLE <br />UNITS IN MANUFACTURER’S PLANT. WHERE PRACTICAL, FACTORY OR SHOP FIT AND <br />ASSEMBLE UNITS FOR SHIPMENT. <br />2. WELD JOINTS CONTINUOUSLY; GRIND, DRESS, AND MAKE SMOOTH, FLUSH, AND <br />INVISIBLE. FILLER TO CONCEAL MANUFACTURING DEFECTS OR DAMAGE IS NOT <br />PERMITTED. <br />3. CORNER JOINTS: FINISH CORNER JOINTS BY MITERING, OR COPING AND BUTTING, <br />OR A COMBINATION OF BOTH. TRIM AND BACKBEND SHALL BE CONTINUOUS AROUND <br />CORNER. <br />4. CONTINUOUSLY WELD JOINTS FOR FULL DEPTH AND WIDTH OF FRAME, TRIM, AND <br />BACKBENDS. <br />5. CLEARANCES FOR FIRE-RATED DOORS: AS REQUIRED BY NFPA 80. <br />2.04 FRAMES <br />A. GENERAL: PROVIDE FULLY WELDED STEEL FRAMES WITH INTEGRAL STOPS AND TRIM FOR <br />DOORS, TRANSOMS, SIDELIGHTS, BORROWED LIGHTS, AND OTHER OPENINGS, AND WITH <br />DETAILS INDICATED FOR TYPE AND PROFILE. USE CONCEALED FASTENINGS, UNLESS <br />OTHERWISE INDICATED. <br />B. METAL THICKNESS OF FRAMES (MINIMUM): <br />1. INTERIOR HOLLOW METAL FRAMES UP TO 4-FOOT WIDE 16 GAGE <br />2. INTERIOR HOLLOW METAL FRAMES WIDER THAN 4-FOOT 14 GAGE <br />C. SUPPORTS AND ANCHORS: FABRICATE FROM AT LEAST 16-GAGE, GALVANIZED STEEL SHEET. <br />FRAME ANCHORS SHALL COMPLY WITH FIRE RATED LABEL REQUIREMENTS OF OPENING. <br />1. FLOOR ANCHORS: <br />A. MINIMUM THICKNESS: 12 GAGE GALVANIZED STEEL SHEET OR BENT <br />STEEL PLATE, SECURELY FASTENED INSIDE EACH JAMB, WITH TWO HOLES IN <br />ANCHOR AT EACH JAMB FOR 3/8 INCH FLOOR ANCHORAGE FASTENERS. FOR <br />PREFRAMED WOOD STUD WALLS PROVIDE AND ADDITIONAL WOOD STUD <br />ANCHOR LOCATED AS CLOSE TO THE BOTTOM OF THE JAMB AS IS <br />PRACTICAL. <br />B. WHERE REQUIRED AT SLOPING AND UNEVEN FLOOR CONDITIONS, OR TO <br />COORDINATE ADJUSTMENTS FOR TRIM ALIGNMENTS, PROVIDE ADJUSTABLE <br />FLOOR ANCHORS, PROVIDING AT LEAST 2-INCH HEIGHT ADJUSTMENTS. <br />2. JAMB ANCHORS: <br />A. LOCATE ANCHORS NEAR TOP AND BOTTOM AND AT INTERMEDIATE POINTS <br />NOT TO EXCEED 24 INCHES ON CENTER. PROVIDE TWO ANCHORS PER HEAD <br />FOR OPENINGS UP TO 48 INCHES WIDE; OVER 48 INCHES WIDE PROVIDE <br />ANCHORS AT 24 INCHES ON CENTER MAXIMUM. <br />B. ANCHORS IN STUD PARTITIONS: PROVIDE STEEL ANCHORS, 16 GAGE <br />MINIMUM SHEET STEEL, OF DESIGN TO SUIT PARTITION CONSTRUCTION, <br />SECURELY WELDED INSIDE EACH JAMB. <br />C. THROUGH-FRAME ANCHORS: AT FRAMES INDICATED TO BE ANCHORED <br />WITH BOLTS THROUGH FRAME, PROVIDE COUNTERSUNK HOLES FOR BOLTS <br />WITH 16 GAUGE MINIMUM SHEET STEEL STIFFENERS FULL THICKNESS OF <br />FRAME, AND SECURELY WELDED INSIDE EACH FRAME AT EACH HOLE. <br />D. INSERTS, BOLTS, AND FASTENERS: PROVIDE MANUFACTURER'S STANDARD UNITS. WHERE <br />ZINC-COATED ITEMS ARE TO BE BUILT INTO EXTERIOR WALLS, COMPLY WITH ASTM A153 CLASS <br />C OR D AS REQUIRED. <br />E. HEAD REINFORCING: REINFORCING SHALL NOT ACT AS LINTEL OR LOAD-CARRYING MEMBER <br />AND SHALL COMPLY WITH FIRE RATING REQUIREMENTS. PROVIDE AT FRAMES REGARDLESS <br />OF WHETHER A CLOSER IS CALLED FOR. <br />F. HARDWARE REINFORCEMENT AND ACCESSORIES: <br />1. BUTT HINGE: 7 GAGE MINIMUM. <br />2. CONTINUOUS HINGE: 14 GAGE CONTINUOUS STRIP REINFORCING. <br />3. HEAD ASSEMBLIES: REINFORCED INTERNALLY WITH, FULL LENGTH, 10 GAGE <br />ANGLES ON EACH SIDE OF FRAME AND BAR AT BOTTOM OF STOP FOR CLOSER <br />REINFORCEMENT IN FRAMES AS SHOWN IN DETAIL #2 OF THIS SECTION. <br />4. REINFORCING FOR OTHER ITEMS OF FINISH HARDWARE SHALL BE ACCOMPLISHED <br />ACCORDING TO ANSI A250.6. <br />G. GLAZED OPENINGS: APPLIED STOPS WITH MITERED OR BUTTED CORNERS, OF MINIMUM 18 <br />GAGE GALVANIZED STEEL, ONE-PIECE LENGTHS, SECURED WITHIN 3” OF ENDS AND AT 12” <br />CENTERS WITH OVAL HEAD COUNTERSUNK TAMPER RESISTANT SCREWS. CORNER JOINTS <br />SHALL BE FURNISHED WITH CONTACT EDGES CLOSED TIGHT, WITH TRIM FACES MITERED AND <br />CONTINUOUSLY WELDED. FRAMES FOR MULTIPLE OPENINGS SHALL BE PROVIDED WITH <br />MULLION AND/OR RAIL MEMBERS, FABRICATED OF CLOSED TUBULAR SHAPES WITH NO VISIBLE <br />SEAMS OR JOINTS. JOINTS BETWEEN FACES OF ABUTTING MEMBERS SHALL BE SECURELY <br />WELDED AND FINISHED SMOOTH. PROVIDE CONDENSATE WEEPS 4 INCHES ON CENTERS, <br />MAXIMUM. <br />I. DOOR SILENCERS: DRILL AND PUNCH FRAMES FOR THREE SILENCERS AT LOCK JAMB OF <br />SINGLE SWING DOORS OR IN DOUBLE DOORS WITH ASTRAGAL AND ONE SILENCER PER LEAF IN <br />HEADS OF DOUBLED DOOR FRAMES. <br />J. WHERE FRAMES ARE INSTALLED IN WALLS SITTING ON A CONCRETE CURB, PROVIDE A <br />CLOSURE PLATE OR EXTEND BACKBENDS TO PROVIDE CLOSURE WHERE FRAME ABUTS <br />CONCRETE CURB <br />2.05 SHOP PRIMING <br />A. EXPOSED AND CONCEALED METAL SURFACES OF HOLLOW METAL DOORS, FRAMES AND <br />OTHER HOLLOW METAL WORK OF THIS SECTION SHALL BE BONDERIZED AND THEN SHOP <br />PRIMED. <br />B. EXPOSED SURFACES OF DOORS, FRAMES AND ACCESSORIES SHALL BE FILLED, SANDED <br />SMOOTH AND CLEANED BEFORE PAINTING. <br />C. EXPOSED SURFACES SHALL BE SHOP PRIMED AFTER ASSEMBLY. <br />PART 3 - EXECUTION <br />3.01 FRAME INSTALLATION <br />A. INSTALL STEEL FRAMES ACCURATELY IN LOCATION, PERFECT ALIGNMENT, PLUMB, <br />STRAIGHT AND TRUE. BRACE FRAMES TO PREVENT DISPLACEMENT. <br />B. ANCHOR FRAMES IN STEEL AND WOOD FRAME PARTITIONS WITH MANUFACTURER <br />RECOMMENDED ANCHORS. <br />C. INSTALL FRAME AT FIRE RATED OPENINGS IN ACCORDANCE WITH NFPA STANDARD NO. 80. <br />D. FURNISH FILLER FOR ANCHOR ATTACHMENT SCREWS, AND SAND SMOOTH. <br />3.02 PRIME COAT TOUCH-UP <br />A. IMMEDIATELY AFTER INSTALLATION, REMOVE RUST, REPAIR DAMAGED SURFACES TO NEW <br />CONDITION, SAND SMOOTH, AND INSTALL TOUCH-UP PRIMER. <br />3.03 CLEAN UP <br />A. REMOVE RUBBISH, DEBRIS AND WASTE MATERIALS AND LEGALLY DISPOSE OF OFF PROJECT <br />SITE. <br />3.04 PROTECTION <br />A. PROTECT WORK OF THIS SECTION UNTIL SUBSTANTIAL COMPLETION. <br />END OF SECTION <br />SECTION 08 1416 <br />FLUSH WOOD DOORS <br />PART 1 - GENERAL <br />1.01 SUMMARY <br />A. SECTION INCLUDES: <br />1. WOOD DOORS. <br />B. RELATED REQUIREMENTS: <br />1. DIVISION 01 - GENERAL REQUIREMENTS. <br />2. SECTION 06 2000 - FINISH CARPENTRY. <br />3. SECTION 08 1113 - HOLLOW METAL DOORS AND FRAMES <br />4. SECTION 08 7100 - DOOR HARDWARE. <br />5. SECTION 08 8000 - GLAZING. <br />6. SECTION 09 9000 - PAINTING AND COATING. <br />1.02 DESIGN REQUIREMENTS <br />A. DRAWINGS INDICATE SIZES, LOCATIONS AND GENERAL DETAILS OF WOOD DOOR <br />CONSTRUCTION AND INSTALLATION. <br />1.03 SUBMITTALS <br />A. SHOP DRAWINGS: SUBMIT SCHEDULES, PLANS, ELEVATIONS AND DETAILS INDICATING DOOR <br />CONSTRUCTION DETAILS, OPENING IDENTIFICATION SYMBOLS, SIZES, DOOR TYPE AND GRADE, <br />FIRE CLASSIFICATION, SWING, LIGHT AND LOUVER CUTOUT SIZE AND LOCATIONS, AND <br />UNDERCUTS. <br />B. PRODUCT DATA: SUBMIT MANUFACTURERS TECHNICAL DATA FOR EACH SPECIFIED DOOR <br />TYPE, INCLUDING DETAILS OF WOOD SPECIES, DESIGN AND CONSTRUCTION, FACTORY <br />FINISHING SPECIFICATIONS AND INSTALLATION INSTRUCTIONS. <br />C. CERTIFICATES: <br />1. SUBMIT CERTIFICATE THAT SOLID CORE DOORS COMPLY WITH ALL REQUIREMENTS <br />OF ANSI/WDMA I.S. 1-A. <br />2. SUBMIT CERTIFICATION THAT FIRE RATED DOORS COMPLY WITH CBC SECTION 715 <br />OR UL 10B. <br />1.04 QUALITY ASSURANCE <br />A. WOOD DOORS CONSTRUCTION, MANUFACTURE, AND FABRICATION SHALL CONFORM TO <br />ANSI/WDMA I.S. 1-A, CUSTOM GRADE, EXTRA HEAVY DUTY GRADE INCLUDING THE LATEST <br />REVISIONS, AND SPECIAL REQUIREMENTS SPECIFIED. <br />B. DOORS SHALL BE FABRICATED, HARDWARE FACTORY FITTED AND MACHINED, AND FACTORY <br />FINISHED, UNLESS NOTED OTHERWISE. <br />C. WOOD DOOR FINISHES SHALL COMPLY WITH THE ARCHITECTURAL WOODWORK INSTITUTE <br />STANDARDS. <br />D. DOORS SHALL BE PRODUCTS OF ONE MANUFACTURER. <br />1.05 WARRANTY <br />A. MANUFACTURER SHALL PROVIDE A TWO YEAR MATERIAL WARRANTY FOR EXTERIOR <br />DOORS. <br />B. MANUFACTURER SHALL PROVIDE A LIFE TIME MATERIAL WARRANTY FOR INTERIOR <br />DOORS. <br />C. INSTALLER SHALL PROVIDE A TWO YEAR FABRICATION AND INSTALLATION WARRANTY <br />FOR ALL DOORS. <br />PART 2 - PRODUCTS <br />2.01 MANUFACTURERS <br />A. PROVIDE PRODUCTS MANUFACTURED BY ONE OF THE FOLLOWING: <br />1. ALGOMA HARDWOOD INC. <br />2. BRENTWOOD MANUFACTURING. <br />3. EGGERS INDUSTRIES. <br />4. MOHAWK FLUSH DOOR, INC <br />5. VT INDUSTRIES, INC. <br />6. WESTERN OREGON DOOR. <br />7. EQUAL. <br />2.02 DOOR CONSTRUCTION <br />A. INTERIOR FLUSH DOORS: <br />1. INTERIOR DOORS SHALL BE FURNISHED AS FOLLOWS: <br />A. TRANSPARENT FINISHED (STAINED): CUSTOM GRADE. SOLID WOOD <br />CORE, 5 PLY, VENEER FACED, FULLY BONDED TO CORE. <br />B. OPAQUE FINISHED (PAINTED): CUSTOM GRADE. SOLID WOOD CORE, 5 PLY, <br />MDO HARDBOARD FACE, FULLY BONDED TO CORE. <br />2. STRUCTURAL-COMPOSITE-LUMBER-CORE DOORS: <br />A. STRUCTURAL COMPOSITE LUMBER: WDMA I.S.10. <br />B. SCREW WITHDRAWAL, FACE: 700 POUND-FEET. <br />C. SCREW WITHDRAWAL, EDGE: 400 POUND-FEET. <br />3. EDGE STRIPS: KILN-DRIED BIRCH, MAPLE OR OTHER MATERIAL AS INDICATED. <br />A. TRANSPARENT FINISHED DOORS: SAME SPECIES AS FACE VENEER OR <br />SIMILAR IN OVERALL COLOR, GRAIN, CHARACTER AND CONTRAST AS THE <br />FACE VENEER. <br />B. OPAQUE FINISHED DOORS: CLOSE GRAIN HARDWOOD. <br />4. FULL STILE EDGE STRIP SHALL BE NOT LESS THAT 1 ½ INCHES WIDE, TWO PLY <br />STILE. STILES SHALL BE FULLY BONDED TO THE CORE. THE OUTER FACE STILE <br />SHALL BE FULL LENGTH ¾ INCH BIRCH OR MAPLE. THE INNER BACK STILE SHALL BE ¾ <br />INCH OF SIMILAR SPECIES WHICH MAY HAVE TWO FINGER JOINTS FULLY BONDED TO <br />CORE. <br />5. TOP AND BOTTOM EDGE RAILS SHALL BE FULL LENGTH AND MAY BE OF GLUED UP <br />STOCK OF SIMILAR SPECIES AS EDGE STRIP, WHITE FIR OR DOUGLAS FIR, MINIMUM <br />DENSITY 24.33 POUNDS OR HIGHER PER CUBIC FOOT. TOP RAIL SHALL BE MINIMUM <br />OF 2 INCHES. BOTTOM RAIL SHALL BE MINIMUM OF 5 INCHES FULLY BONDED TO <br />CORE. <br />6. CROSSBANDING: DOORS SHALL BE FURNISHED WITH FULL WIDTH CROSSBANDING <br />OF PROPERLY DRIED HARDWOOD OR ENGINEERED FIBER COMPOSITE MATERIAL, 1/16 <br />INCH THICK, WITH A DENSITY OF 52 POUNDS OR HIGHER PER CUBIC FOOT. <br />7. FACE VENEER FOR TRANSPARENT FINISHED DOORS: CUSTOM GRADE, VENEER <br />SHALL BE GRADE”A”. MINIMUM THICKNESS SHALL BE 0.0277 INCHES BEFORE SANDING <br />AND 0.020 INCHES AFTER SANDING OF SPECIFIED FACE VENEER. <br />A. VENEER SPECIES: <br />B. VENEER CUT: ROTARY <br />C. VENEER MATCH: BOOK <br />D. PAIRS: NOT MATCHED <br />8. OPAQUE FINISHED DOORS: CUSTOM GRADE MEDIUM DENSITY OVERLAY <br />HARDBOARD. <br />9. ADHESIVE AND BONDING: BONDING BETWEEN VENEER PLIES OF WOOD FACE <br />PANEL, AND BETWEEN DOOR FACES, FRAME AND CORE UNIT SHALL BE FABRICATED <br />WITH TYPE I OR II WATERPROOF ADHESIVES FOR INTERIOR DOORS. <br />10. OPENINGS: OPENINGS FOR LIGHTS, LOUVERS AND GRILLES SHALL BE <br />PERFORMED BY THE MANUFACTURER, OR IN A CERTIFIED DOOR SERVICE MILL IN <br />ACCORDANCE WITH MANUFACTURER’S DETAILS, AND IN COMPLIANCE WITH TESTING <br />AGENCY REQUIREMENTS. <br />2.03 FINISHING: <br />A. FACTORY FINISHING: <br />1. FACTORY FINISHING SHALL BE AWI CUSTOM GRADE AND INCLUDE ALL NECESSARY <br />PREPARATION, MATERIALS AND LABOR TO PROVIDE AN CLEAR TRANSPARENT FINISH. <br />1. FINISH FACES, ALL FOUR EDGES, EDGES OF CUTOUTS, AND MORTISES. <br />STAINS AND FILLERS MAY BE OMITTED ON TOP AND BOTTOM EDGES, EDGES <br />OF CUTOUTS, AND MORTISES. <br />2. FINISH: UV CURABLE, WATER BASED. <br />3. STAINING: AS SELECTED BY ARCHITECT FROM MANUFACTURER'S FULL <br />RANGE. <br />4. SHEEN: SEMIGLOSS. <br />B. JOB SITE FINISHING: <br />1. DOORS INDICATED TO BE JOB SITE FINISHED SHALL BE FACTORY BACK PRIMED. <br />A. DOORS SCHEDULED FOR OPAQUE PAINT FINISH: PRIME WITH ONE COAT <br />OF WOOD PRIMER INDICATED ON SECTION 09 9000 - PAINTING AND COATING. <br />B. DOORSSCHEDULES FOR TRANSPARENT FINISH: PRIME WITH STAIN AND <br />FIRST COAT OF FINISH AS INDICATED IN SECTION 09 9000 - PAINTING AND <br />COATING. <br />2. DOOR FINISH: PER SECTION 09 9000 - PAINTING AND COATING. <br />PART 3 - EXECUTION <br />3.01 INSTALLATION <br />A. PROVIDE EACH DOOR ACCURATELY CUT, TRIMMED, AND FITTED TO ITS FRAME AND <br />HARDWARE. CLEARANCE AT LOCK AND HANGING STILE AND AT TOP SHALL BE 1/8 INCH, AND <br />BOTTOM SHALL NOT EXCEED 1/4 INCH EXCEPT WHERE OTHERWISE INDICATED. ARISES SHALL <br />BE ROUNDED TO A 1/16 INCH RADIUS, AND LOCK RAIL EDGES SHALL BE SLIGHTLY BEVELED. <br />SCREWS FOR HARDWARE SHALL NOT BE DRIVEN BUT SCREWED INTO PRE-DRILLED HOLES. <br />B. DOORS SHALL OPERATE FREELY, BUT NOT LOOSELY, WITHOUT STICKING OR BINDING, <br />WITHOUT HINGE-BIND CONDITIONS AND WITH HARDWARE PROPERLY ADJUSTED AND <br />FUNCTIONING. <br />3.02 CLEAN UP <br />A. REMOVE RUBBISH, WASTE AND DEBRIS AND LEGALLY DISPOSE OF OFF THE PROJECT SITE. <br />3.03 PROTECTION <br />A. PROTECT THE WORK OF THIS SECTION UNTIL SUBSTANTIAL COMPLETION. <br />END OF SECTION <br />SECTION 08 8000 <br />GLAZING <br />PART 1 - GENERAL <br />1.01 SUMMARY <br />A. SECTION INCLUDES: <br />1. GLASS AND GLAZING AS INDICATED. <br />B. RELATED REQUIREMENTS: <br />1. DIVISION 01 - GENERAL REQUIREMENTS. <br />2. SECTION 08 1416 - FLUSH WOOD DOORS. <br />3. SECTION 08 5113 - ALUMINUM WINDOWS. <br />1.02 SUBMITTALS <br />A. PRODUCT DATA: SUBMIT MANUFACTURER'S DESCRIPTIVE LITERATURE AND I <br />INSTALLATION RECOMMENDATIONS FOR GLASS, GLAZING, AND ACCESSORIES. <br />B. MATERIAL SAMPLES: SUBMIT 6-INCH SQUARE UNITS OF EACH TYPE OF GLASS <br />SPECIFIED. <br />1.03 QUALITY ASSURANCE <br />A. LABELING: LABEL EACH PIECE OF GLASS AND GLAZING AND MIRRORS WITH M <br />MANUFACTURER'S NAME, AND THE GRADE OR QUALITY OF THE MATERIAL. LABELS <br />SHALL BE INTACT BEFORE AND AFTER INSTALLATION. FIRE-PROTECTION-RATED <br />GLAZING SHALL BEAR A LABEL OR OTHER IDENTIFICATION IN ACCORDANCE TO <br />CBC 715.5. <br />B. COMPLY WITH THE FOLLOWING AS A MINIMUM REQUIREMENT: <br />1. ASTM C864 - STANDARD SPECIFICATION FOR DENSE ELASTOMERIC <br />COMPRESSION SEAL GASKETS, SETTING BLOCKS, AND SPACERS. <br />2. ASTM C1036 - STANDARD SPECIFICATION FOR FLAT GLASS. <br />3. ASTM C1048 - STANDARD SPECIFICATION FOR HEAT-TREATED FLAT <br />GLASS —KIND HS, KIND FT COATED AND UNCOATED GLASS. <br />4. CPSC 16 CFR 1201 - SAFETY STANDARDS FOR ARCHITECTURAL GLAZING <br />MATERIALS ISSUED BY THE CONSUMER PRODUCTS SAFETY COMMISSION. <br />5. GANA - GLAZING MANUAL. <br />C. QUALIFICATIONS OF INSTALLER: MINIMUM FIVE YEARS EXPERIENCE INSTALLING <br />GLASS IN PROJECTS OF SIMILAR SCOPE AND COMPLEXITY. <br />1.04 DELIVERY, STORAGE AND HANDLING <br />A. DELIVER GLASS AND GLAZING MATERIALS WITH MANUFACTURER'S LABELS INTACT. <br />B. DO NOT REMOVE LABELS UNTIL GLASS HAS BEEN INSTALLED AND INSPECTED BY <br />THE PROJECT INSPECTOR. <br />C. PROTECT GLASS FROM STAINING, MARKING, AND DAMAGE. <br />D. PUTTY AND GLAZING COMPOUND SHALL BE DELIVERED TO THE PROJECT SITE IN <br />MANUFACTURER'S ORIGINAL UNBROKEN CONTAINERS LABELED TO IDENTIFY C <br />ONTENTS. <br />1.05 PROJECT CONDITIONS <br />A. PERFORM GLAZING WHEN AMBIENT TEMPERATURE IS ABOVE 40 DEGREES F. <br />B. PERFORM GLAZING ON CLEAN, DRY SURFACES ONLY. <br />1.06 WARRANTY <br />A. MANUFACTURER SHALL PROVIDE A TEN YEAR MATERIAL WARRANTY. <br />B. MANUFACTURER SHALL PROVIDE A TWENTY YEAR MATERIAL WARRANTY FOR <br />COATINGS AND THERMALLY OR ACOUSTICALLY RATED INSULATION UNITS AGAINST <br />DETERIORATION IN ACOUSTIC OR THERMAL RATING. <br />C. INSTALLER SHALL PROVIDE A THREE YEAR FABRICATIONS AND INSTALLATION <br />WARRANTY. <br />PART 2 - PRODUCTS <br />2.01 ACCEPTABLE MANUFACTURERS AND FABRICATORS <br />A. TO MAXIMUM EXTENT POSSIBLE, PROVIDE DOMESTICALLY MANUFACTURED AND <br />FABRICATED GLASS, AND PROVIDE GLASS FROM ONE MANUFACTURER. <br />B. TYPES OF GLASS SPECIFIED OR INDICATED SHALL BE MANUFACTURED OR <br />FABRICATED BY ONE OF THE FOLLOWING (U.N.O.): <br />1. PILKINGTON LOF (FIRE RATED GLAZING). <br />2. PPG GLASS TECHNOLOGY. <br />3. VISTEON FLOAT GLASS OPERATIONS. <br />4. VIRACON. <br />5. SOUTHWEST TECHNOLOGIES. <br />6. EQUAL. <br />2.02 GLASS MATERIALS <br />A. GENERAL: CONFORM TO ASTM C1036, ASTM C1048 AND TO ANSI Z97.1. LABEL <br />FACTORY CUT PANES. <br />B. FLOAT GLASS: TYPE I, (TRANSPARENT GLASS FLAT), CLASS 1 (CLEAR), QUALITY Q3, <br />(GLAZING SELECT), MINIMUM 1/4 INCH THICKNESS UNLESS OTHERWISE INDICATED O <br />R REQUIRED. <br />C. TINTED FLOAT GLASS: TYPE I (TRANSPARENT GLASS), CLASS 2 (TINTED HEAT <br />ABSORBING AND LIGHT REDUCING), QUALITY Q3 (GLAZING SELECT), <br />MANUFACTURED BY PPG OR LOF, COLOR AS SELECTED BY ARCHITECT, MINIMUM 1/4 <br />INCH THICKNESS UNLESS OTHERWISE INDICATED OR REQUIRED. <br />D. TEMPERED GLASS: CONDITION A (UNCOATED SURFACES), TYPE I OR II, CLASS 1, <br />QUALITY Q3 (GLAZING SELECT), KIND FT (FULLY TEMPERED GLASS), MATCH COLOR <br />OF CLEAR OR TINTED GLASS AS APPLICABLE; FULLY THERMAL TEMPERED, HEAT <br />STRENGTHENING OR CHEMICAL TEMPERING IS NOT PERMITTED. PERFORM <br />TEMPERING BY HORIZONTAL OSCILLATING ROLLER HEARTH OR HIGH SPEED R <br />OLLER HEARTH PROCESS. DO NOT PERMIT FABRICATION PROCESSES LEAVING <br />GRIPPER OR TONG MARKS. HANDLE AND SIZE GLASS ACCORDING TO <br />MANUFACTURER'S WRITTEN INSTRUCTIONS. <br />E. CLEAR LAMINATED GLASS: TWO LAYERS OF 1/8 INCH CLEAR FLOAT GLASS WITH <br />0.030 INCH THICK HIGH STRENGTH POLYVINYL BUTYRAL LAMINATING SHEET. <br />F. TINTED LAMINATED GLASS: ONE LAYER OF 1/8 INCH CLEAR FLOAT GLASS AND ONE <br />LAYER OF TINTED GLASS TO MATCH OTHER WINDOWS, WITH 0.030 INCH THICK HIGH <br />STRENGTH POLYVINYL BUTYRAL LAMINATING SHEET. EDGES OF <br />LAMINATED GLASS SHALL BE TREATED WITH ARGOTEC, ARGO EDGE SEAL PLUS, OR <br />EQUAL, EDGE PROTECTION TO PREVENT CONTACT OF LAMINATING SHEET WITH <br />SEALANTS. <br />G. LOW EMISSIVITY GLASS (LOW E GLASS): PROVIDE UNITS WITH THIN METALLIC HIGH- <br />TRANSMITTANCE COATING APPLIED TO THE NUMBER 3 SURFACE OF THE U <br />NIT, UNLESS OTHERWISE INDICATED. THE U-VALUE FOR THE IGU SHALL BE NO <br />GREATER THAN 0.34, UNLESS OTHERWISE INDICATED. <br />H. OBSCURE GLASS: TYPE II (PATTERNED), CLASS 1 (CLEAR), FORM 3 (PATTERNED), <br />QUALITY Q7 (DECORATIVE), PATTERNED ONE SIDE, PATTERN AS INDICATED OR S <br />ELECTED. <br />I. THERMOPLASTIC GLAZING: POLYCARBONATE SHEET SHALL BE ULTRA-VIOLET <br />STABILIZED MATERIAL, CLEAR OR GLARE REDUCING AS INDICATED, 1/4 INCH THICK A <br />AS MANUFACTURED BY GENERAL ELECTRIC COMPANY “LEXAN”, DUPONT, OR E <br />EQUAL. GLARE REDUCING GLAZING SHALL BE GRAY IN COLOR, PROVIDING A LIGHT <br />TRANSMISSION OF 14 PERCENT. <br />2.03 GLASS SETTING MATERIALS <br />A. SETTING BLOCKS: ASTM C864, CHANNEL SHAPE; HAVING ¼ INCH INTERNAL DEPTH, S <br />SHORE A HARDNESS OF 80 TO 90 DUROMETER. BLOCKS SHALL BE A MINIMUM 2 <br />INCH LONG. BLOCK WIDTH SHALL BE APPROXIMATELY 1/16 INCH LESS THAN THE <br />FULL WIDTH OF THE RABBET. BLOCK THICKNESS SHALL BE AT LEAST 3/16 INCH, <br />SIZED FOR RABBET DEPTH AS REQUIRED. <br />B. SPACERS: ASTM C864, CHANNEL SHAPE, WITH ¼ INCH INTERNAL DEPTH, 3/32 INCH <br />FLANGES, EB, 1/8 INCH THICK, ONE TO 3 INCHES LONG. SPACERS SHALL PROVIDE <br />SHORE A HARDNESS OF 40 TO 50 DUROMETER. <br />C. VINYL GLAZING CHANNELS: PROFILE COMPATIBLE WITH FRAMING SYSTEM AND <br />DESIGNED TO ACCOMMODATE GLASS OF SPECIFIED THICKNESS, LIGHT GRAY IN <br />COLOR. PROVIDE FOR DRY GLAZING ALUMINUM FRAMES WHERE INDICATED OR <br />PERMITTED. <br />D. GLAZING TAPE: POLY-ISOBUTYLENE BASED SEALANT TAPE, CONFORMING TO AAMA <br />804.1, WITH ADHESIVE ONE SIDE PROTECTED BY TEMPORARY PAPER COVER, <br />EXTRU-SEAL MANUFACTURED BY PECORA CORP., NO. 303 BY PROTECTIVE <br />TREATMENTS, INC., OR EQUAL. <br />E. SPRING STEEL SPACERS: GALVANIZED STEEL WIRE OR STRIP DESIGNED TO <br />POSITION GLAZING IN CHANNEL OR RABBET SASH WITH STOPS. <br />F. GLAZING CLIPS: GALVANIZED STEEL SPRING WIRE DESIGNED TO HOLD GLASS IN <br />POSITION IN RABBET SASH WITHOUT STOPS. <br />G. GLAZING POINTS (SPRIGS): PURE ZINC STOCK, THIN, FLAT, TRIANGULAR OR D <br />IAMOND-SHAPED PIECES, 1/4 INCH MINIMUM SIZE. <br />H. GLAZING SEALANTS FOR METAL SASH: GE SILICONES SILGLAZE II 2800, GE <br />SILICONES SILPRUF, GE SILICONES 1200 SILICONE, AND DOW CORNING 999A. <br />POLYBUTYLENE, OLEORESINOUS, ASPHALT, AND OIL BASE SEALANTS ARE N <br />NOT PERMITTED. PROVIDE SEALANT OF SAME COLOR AS STRUCTURAL SILICONE <br />SEALANT UNLESS OTHERWISE REQUIRED. <br />I. GLAZING COMPOUND FOR WOOD SASH: PROVIDE ACRYLIC LATEX GLAZING <br />COMPOUND FOR BEDDING AND SEALING GLASS IN WOOD FRAMES <br />J. GLAZING COMPOUNDS AND SEALANTS FOR THERMOPLASTIC: PROVIDE SILICONE, <br />BUTYL, OR POLYSULFIDE GLAZING COMPOUND. <br />2.04 SPEAK HOLES <br />A. SPEAK HOLES SHALL BE STOCK NO. 444, 4 TO 6-INCH DIAMETER FOR 1/4-INCH T <br />TEMPERED FLOAT GLASS, STAINLESS STEEL AS MANUFACTURED BY NISSEN AND <br />CO., N666 BY C.R. LAURENCE CO., OR EQUAL. <br />PART 3 - EXECUTION <br />3.01 TOLERANCES <br />A. THICKNESS INDICATED OR SPECIFIED ARE NOMINAL WITHIN STANDARD <br />TOLERANCES. MAXIMUM SIZE OF VERTICAL PANES SHALL NOT EXCEED THE <br />FOLLOWING: <br />FLOAT THICKNESS: 1/8 INCH 3/16 INCH 1/4 INCH <br />MAXIMUM AREAS IN SQUARE FEET: 12 16 20 <br />WHEN EXCEEDING THESE SQUARE FOOT MEASUREMENTS GLASS IS TO BE SAFETY <br />GLAZED. <br />3.02 INSTALLATION, GENERAL <br />A. GLAZED CABINET DOORS, WINDOWS, TRANSOMS, AND FIXTURES, NOT OTHERWISE <br />NOTED OR INDICATED, SHALL BE GLAZED WITH CLEAR FLOAT GLASS. ROOM OR <br />ENTRANCE DOORS SHALL BE GLAZED WITH CLEAR WIRE GLASS. <br />B. OBSCURE GLASS IN EXTERIOR OPENINGS SHALL BE INSTALLED WITH SMOOTH SIDE <br />OF GLASS TO WEATHER. PATTERNED GLASS SHALL BE INSTALLED WITH PATTERN R <br />RUNNING VERTICALLY, UNLESS OTHERWISE INDICATED. <br />C. GLAZING TAPES OR SEALANTS SHALL BE INSTALLED WHEREVER GLASS CONTACTS <br />WOOD OR METAL SURFACES. WIDTH OF STRIPS SHALL BE AS REQUIRED. <br />D. GLAZING COMPOUND SHALL BE NEATLY AND CLEANLY INSTALLED IN STRAIGHT <br />LINES, EVEN WITH INSIDE EDGE OF SASH MEMBERS. THUMB PUTTYING IS NOT <br />PERMITTED. <br />E. DISPLAY CASES AND SLIDING GLASS DOORS IN CASEWORK: GLASS IN DISPLAY <br />CASES SHALL BE ¼ INCH CLEAR LAMINATED GLASS AS INDICATED. EDGES OF <br />GLASS SHALL BE ROUNDED AND POLISHED. <br />F. GLAZING ALUMINUM SASH: GLAZING MATERIAL IN ALUMINUM SASH SHALL BE <br />INSTALLED IN COMPOUND AND SECURED IN PLACE WITH ALUMINUM GLAZING <br />BEADS. IN ADDITION, HORIZONTAL BEADS SHALL BE INSTALLED WITH 6-INCH BY 1 <br />INCH, TYPE A, SELF-TAPPING, STAINLESS STEEL, PHILLIPS-HEAD SCREWS, <br />INSTALLED INTO PRE-DRILLED, COUNTER-SUNK HOLES AND SPACED 2 INCHES FROM <br />EACH END AND 9 INCHES ON CENTERS. <br />3.03 INSTALLATION OF GLASS <br />A. CONFORM TO REQUIREMENTS OF GANA GLAZING MANUAL. <br />B. PROVIDE EDGE BLOCKING TO COMPLY WITH REQUIREMENTS OF REFERENCED G <br />GLAZING STANDARD, EXCEPT WHERE OTHERWISE REQUIRED BY GLASS UNIT <br />MANUFACTURER. <br />C. PROVIDE COMPRESSIBLE FILLER RODS OR EQUIVALENT BACK-UP MATERIAL TO <br />PREVENT SEALANT FROM EXTRUDING INTO GLASS CHANNEL WEEP SYSTEMS, FROM <br />ADHERING TO BACK SURFACE OF JOINTS AND TO CONTROL DEPTH OF SEALANT <br />FOR OPTIMUM PERFORMANCE. <br />D. FORCE SEALANTS INTO GLAZING CHANNELS, IN MANNER TO ELIMINATE VOIDS AND <br />TO ENSURE COMPLETE BOND OF SEALANT TO GLASS AND CHANNEL SURFACES. <br />E. TOOL EXPOSED SURFACES OF SEALANTS TO PROVIDE FOR DRAINAGE AWAY FROM <br />GLASS. INSTALL PRESSURIZED TAPES AND GASKETS TO PROTRUDE SLIGHTLY OUT <br />OF CHANNEL TO ELIMINATE DIRT AND MOISTURE POCKETS. <br />F. WHERE DRY GLAZING OF ALUMINUM FRAME IS INDICATED OR PERMITTED, PROVIDE <br />VINYL GLAZING CHANNELS INSTALLED IN ACCORDANCE WITH FRAME <br />MANUFACTURERS WRITTEN RECOMMENDATIONS. DO NOT STRETCH CHANNELS. <br />MITER CORNERS. <br />G. FOR TAPE GLAZING, FURNISH TAPE OF THICKNESS TO PROVIDE APPROXIMATELY 30 <br />PERCENT COMPRESSION. CUT TAPE TO PROPER LENGTH AND INSTALL TO <br />PERMANENT STOPS, THE ENTIRE LENGTH OF THE HEAD AND SILL FIRST, THEN TO J <br />JAMBS. BUTT TAPE TOGETHER WITH NO OVERLAP AND REMOVE PAPER BACKING. <br />INSTALL GLASS ON SETTING BLOCKS AT QUARTER POINTS AND MAINTAIN UNIFORM <br />GLASS EDGE CLEARANCE AROUND ENTIRE PERIMETER OF GLASS. MAINTAIN <br />MANUFACTURER'S RECOMMENDED EDGE CLEARANCE AND BITE ON GLASS. <br />INSTALL GLASS FIRMLY INTO TAPE WITH A SLIGHT LATERAL MOVEMENT TO ASSURE <br />PROPER ADHESION. INSTALL TAPE TO REMOVABLE STOP WITH EVENLY <br />DISTRIBUTED FIRMNESS, SMOOTHING OUT WRINKLES IN TAPE. SECURE REMOVABLE <br />STOP IN PROPER POSITION SO TAPE MAKES CONTACT WITH GLASS AS STOP IS INSTALLED, <br />FORCING CONTACT WITH GLASS AND COMPLETELY SEALING JOINT. REMOVE EXCESS TAPE <br />FROM BOTH SIDES AT SLIGHT ANGLE OVER SIGHT LINE. DO NOT UNDERCUT. <br />H. GLASS IN WOOD FRAMES: INSTALL GLASS WITH GLAZING POINTS AND SETTING <br />BLOCKS AS REQUIRED. SEAL GLASS WITH GLAZING COMPOUND AND SECURE WITH <br />WOOD STOPS. INSTALL STOPS WITH FINE FINISHING NAILS, AND SET FOR PUTTY <br />STOPPING. <br />I. PATTERNED GLASS: INSTALL GLASS WITH ONE PATTERNED SMOOTH SURFACE ON <br />THE WEATHER SIDE. <br />J. LAMINATED GLASS: SASHES, WHICH ARE TO RECEIVE LAMINATED GLASS, SHALL BE <br />WEEPED TO THE OUTSIDE TO PERMIT WATER IN THE CHANNEL TO DRAIN FROM THE <br />FRAME. <br />3.04 PROTECTION AND CLEANING <br />A. PROTECT EXTERIOR GLASS FROM BREAKAGE BY FURNISHING CROSSED STREAMERS <br />ATTACHED TO FRAMING AND AWAY FROM GLASS SURFACE. DO NOT DIRECTLY INSTALL <br />MARKERS TO GLASS SURFACES. REMOVE NON-PERMANENT LABELS AND CLEAN <br />SURFACES. <br />B. PROTECT GLASS FROM CONTACT WITH CONTAMINATING SUBSTANCES RESULTING <br />FROM CONSTRUCTION OPERATIONS. IF, DESPITE SUCH PROTECTION, <br />CONTAMINATING SUBSTANCES DO COME INTO CONTACT WITH GLASS, REMOVE <br />IMMEDIATELY BY METHOD RECOMMENDED BY GLASS MANUFACTURER. <br />C. EXAMINE GLASS SURFACES ADJACENT TO OR BELOW EXTERIOR CONCRETE AND <br />OTHER MASONRY SURFACES AT FREQUENT INTERVALS DURING CONSTRUCTION, <br />BUT NOT LESS OFTEN THAN ONCE A MONTH, FOR BUILD-UP OF DIRT, SCUM, ALKALI <br />DEPOSITS OR STAINING. WHEN EXAMINATION REVEALS PRESENCE OF THESE <br />FORMS OF RESIDUE, REMOVE BY METHOD RECOMMENDED BY GLASS <br />MANUFACTURER. GLAZING, WHICH CANNOT BE CLEANED TO A REQUIRED <br />CONDITION, SHALL BE DEEMED DEFECTIVE WORK. <br />D. REMOVE AND REPLACE GLASS, WHICH IS BROKEN, CHIPPED, CRACKED, ABRADED, <br />OR DAMAGED DURING CONSTRUCTION. <br />E. REMOVE PROTECTIVE COVERING FROM THERMOPLASTIC NOT MORE THAN 4 DAYS <br />BEFORE SUBSTANTIAL COMPLETION, AND IMMEDIATELY BEFORE <br />CLEANING. METHODS OF FINAL CLEANING AND FINISHING SHALL BE AS PRESCRIBED <br />BY THERMOPLASTIC GLAZING PUBLICATIONS REFERENCED ABOVE. <br />F. WASH GLASS ON BOTH FACES NOT MORE THAN FOUR DAYS BEFORE SUBSTANTIAL <br />COMPLETION. WASH GLASS BY METHOD RECOMMENDED BY GLASS <br />MANUFACTURER. DO NOT FURNISH HARSH CLEANING AGENTS, CAUSTICS, <br />ABRASIVES, OR ACIDS FOR CLEANING. POLISH GLASS BOTH SIDES AND LEAVE FREE <br />OF SOIL, STREAKS, AND LABELS. <br />3.05 CLEAN UP <br />A. REMOVE RUBBISH, DEBRIS AND WASTE MATERIALS AND LEGALLY DISPOSE OF OFF <br />THE PROJECT SITE. <br />3.06 PROTECTION <br />A. PROTECT THE WORK OF THIS SECTION UNTIL SUBSTANTIAL COMPLETION. <br />END OF SECTION <br />R <br />No. <br />F <br />LICENSE <br />STATE <br />D <br />O <br />A RCHITECT <br />C AL IFORNIA <br />STEPHE WHITE <br />RENEWAL <br />DATE <br />C-34829 <br />N <br />08/31/27 <br />SHEET TITLE <br />PROJECT <br />FACILITY <br />FAC NO: BLDG NO: FLOOR LEV: SECTION: <br />KP PROJ. NO. <br />PERMIT NO. <br />555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA <br />ARCHITECT <br />CONSULTANT <br />ARCHITECT SEAL CONSULTANT SEAL <br />KAISER FOUNDATION HOSPITALS <br />NATIONAL FACILITIES SERVICES <br />1800 HARRISON STREET OAKLAND, <br />CALIFORNIA 94612 <br />ISSUE / REVISION LOG <br />NO. ISSUED DATE <br />0 <br />5' <br /> <br />5 <br />0 <br />' <br />GR <br />A <br />P <br />H <br />I <br />C <br /> <br />S <br />C <br />A <br />L <br />E <br />S <br />: <br /> <br />1 <br />/ <br />1 <br />6 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />0 <br />25 <br />' <br />1/ <br />8 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />5' <br />0 <br />12 <br />' <br />1/ <br />4 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />1' <br />0 <br />6' <br />1/ <br />2 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />1' <br />0 <br />2' <br />1- <br />1 <br />/ <br />2 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />0 <br />1' <br />3" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />IF <br /> <br />T <br />H <br />I <br />S <br /> <br />S <br />H <br />E <br />E <br />T <br /> <br />I <br />S <br /> <br />N <br />O <br />T <br /> <br />30 <br />" <br />x <br />4 <br />2 <br />" <br />, <br /> <br />I <br />T <br /> <br />I <br />S <br /> <br />A <br /> <br />R <br />E <br />D <br />U <br />C <br />E <br />D <br /> <br />PR <br />I <br />N <br />T <br /> <br />- <br /> <br />S <br />C <br />A <br />L <br />E <br /> <br />AC <br />C <br />O <br />R <br />D <br />I <br />N <br />G <br />L <br />Y <br />AGENCY APPLICATION NUMBER <br />AGENCY APPROVAL STAMP <br />THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS <br />NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. <br />HZ PROJ. NO. <br />www.huitt-zollars.com <br />Phone 310.820.4600 | Fax 310.207.4215 <br />C: <br />\ <br />U <br />s <br />e <br />r <br />s <br />\ <br />l <br />r <br />o <br />b <br />i <br />n <br />s <br />o <br />n <br />\ <br />O <br />n <br />e <br />D <br />r <br />i <br />v <br />e <br /> <br />- <br /> <br />H <br />u <br />i <br />t <br />t <br />- <br />Z <br />o <br />l <br />l <br />a <br />r <br />s <br />, <br /> <br />I <br />n <br />c <br />\ <br />D <br />o <br />cu <br />m <br />e <br />n <br />t <br />s <br />\ <br />R <br />3 <br />1 <br />4 <br />4 <br />1 <br />2 <br />. <br />3 <br />5 <br /> <br />K <br />P <br /> <br />H <br />B <br />M <br /> <br />K <br />P <br />O <br />J <br />_ <br />A <br />2 <br />4 <br />_ <br />l <br />r <br />o <br />b <br />i <br />n <br />s <br />o <br />n <br />L <br />2 <br />M <br />D <br />X <br />. <br />r <br />vt <br />1 <br />1 <br />/ <br />3 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />3 <br />: <br />4 <br />4 <br />: <br />0 <br />1 <br /> <br />P <br />M <br />SOCC 2022 R HBM 1st Fl KPOJ <br />REMODEL <br />G0-02 <br />SPECIFICATIONS <br />CA394-1 - <br />CAP027721R314412.35 <br />HARBOR/MacARTHUR MEDICAL OFF <br />3401 S. HARBOR BLVD. <br />SANTA ANA, CALIFORNIA 92704 <br />N/ASPECIFICATIONS - DIVISION 6 CONT 06 N/ASPECIFICATIONS - DIVISION 7 07 N/ASPECIFICATIONS - DIVISION 8 08 <br />CITY SUBMITTAL 11/03/2025 <br />101125520, 20187249, 40140902