Laserfiche WebLink
DIVISION 9 - FINISHES <br />SECTION 09 2900 - GYPSUM BOARD AND FRAMING <br />PART 1 - GENERAL <br />1.1 SUMMARY: <br />A RELATED WORK: <br />1. ELECTRICAL <br />2. PLUMBING <br />1.2 ACTION SUBMITTALS: <br />A. PRODUCT DATA: INDICATE PRODUCT DESCRIPTION, INCLUDING COMPLIANCE WITH <br />SPECIFIED REQUIREMENTS AND INSTALLATION REQUIREMENTS. INCLUDE SPECIFIC <br />REQUIREMENTS FOR FIRE-RATED AND ACOUSTICALLY RATED PARTITIONS AND CEILING <br />ASSEMBLIES. MARK MANUFACTURER'S BROCHURES TO INCLUDE ONLY THOSE <br />PRODUCTS PROPOSED FOR USE. INCLUDE DETAILS FOR SUPPLEMENTARY FIRE <br />PROTECTION AT PENETRATIONS AND LOCATIONS OF ACOUSTICAL SEALANT. <br />1.3 QUALITY ASSURANCE: <br />A. APPLICABLE STANDARDS; STANDARDS OF THE FOLLOWING: <br />1. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI). <br />2. ASTM INTERNATIONAL (ASTM) AS REFERENCED HEREIN. <br />3. GYPSUM ASSOCIATION (GA). <br />4. STEEL STUD MANUFACTURERS ASSOCIATION (SSMA) <br />5. UNDERWRITERS LABORATORIES, INC. (UL) <br />6. INTERTEK TESTING SERVICES/WARNOCK HERSEY, INC. (WHI). <br />PART 2 - PRODUCTS <br />2.1 FRAMING MEMBERS: <br />A. GYPSUM BOARD STUDS: MEETING REQUIREMENTS OF ASTM C645-11; CHANNEL TYPE, <br />ROLL-FORMED FROM DIP GALVANIZED STEEL COMPLYING WITH ASTM A1003-09 AND <br />WITH ASTM A653-11, G40 MINIMUM. <br />1. STUD SIZE: TO MATCH EXISTING <br />2. STUD GAUGE: TO MATCH EXISTING <br />2.2 GYPSUM BOARD: <br />A. FIRE-RETARDANT BOARD: MEETING ASTM C1396-11, TYPE X, THICKNESS INDICATED, <br />TAPERED ROUNDED EDGES. <br />B. MOLD AND MOISTURE RESISTANT BOARD: TREATED PAPER-FACED GYPSUM BOARD. <br />1. ACCEPTABLE PRODUCTS: <br />A. NATIONAL GYPSUM, XP GYPSUM BOARD AND XP FIRE-SHIELD <br />GYPSUM BOARD. <br />B. UNITED STATES GYPSUM (USG), SHEETROCK MOLD TOUGH GYPSUM <br />PANELS. <br />2. THICKNESS: 5/8" THICK TYPE X GRADE FIRE-RATED BOARD, TAPERED EDGES. <br />3. DESCRIPTION: MOLD AND MOISTURE RESISTANT GYPSUM CORE ENCASED <br />IN MOLD AND MOISTURE RESISTANT FACERS, WITH TAPERED LONG EDGES. <br />PANELS SHALL COMPLY WITH ASTM C1396-11. <br />4. MOLD RESISTANCE: RESISTANT TO MOLD GROWTH WHEN TESTED IN ACCORD <br />WITH ASTM D3273-12, SCORE OF 10. <br />5. WATER ABSORPTION: LESS THAN 5% OF BOARD WEIGHT WHEN TESTED IN <br />ACCORD WITH ASTM C473-12. <br />6. JOINT TAPE: AS RECOMMENDED BY GYPSUM BOARD MANUFACTURER. <br />2.3 SOUND CONTROL MATERIALS: <br />A. CONTRACTOR'S OPTION: BASED ON SOUND RATINGS AND FIRE-RESISTANCE RATINGS <br />REQUIRED FOR ASSEMBLIES, CONTRACTOR MAY SELECT GLASS FIBER OR MINERAL <br />WOOL SOUND ATTENUATION MATERIALS AS FOLLOWS: <br />1. GLASS FIBER SOUND ATTENUATION BATTS: <br />A. ACCEPTABLE MANUFACTURERS: <br />1) CERTAINTEED CORP. <br />2) KNAUF INSULATION. <br />3) JOHNS MANVILLE CORP. <br />4) OWENS-CORNING CORP. <br />2. MINERAL WOOL SOUND ATTENUATION BLANKETS: <br />A. ACCEPTABLE MANUFACTURERS: <br />1) IIG, MINWOOL, LLC, MINWOOL SOUND ATTENUATION FIRE <br />BATTS. <br />2) OWENS-CORNING CORP., SOUND ATTENUATION FIRE BATT. <br />3) U.S. GYPSUM CO., THERMAFIBER SAFB (SOUND ATTENUATION <br />FIRE BLANKETS). OWENS-CORNING CORP. <br />2.4 FASTENERS: <br />A. FASTENERS FOR METAL FRAMING, CORROSION-RESISTANT: <br />1. FOR FASTENING FRAMING MEMBERS TO CONCRETE SURFACES: FASTENERS <br />SHALL BE BEADED DRIVE PINS OR THREADED STUDS DRIVEN BY POWER <br />ACTUATED TOOLS. FASTENERS SHALL RESIST DESIGN LOADS IN ACCORD <br />WITH REQUIREMENTS OF ASTM E1190-11. <br />2. FOR FASTENING TO METAL DECKING AND FOR FASTENING FRAMING MEMBERS <br />TOGETHER: TYPE S, PAN HEAD SCREWS, IN SIZES RECOMMENDED BY GYPSUM <br />BOARD MANUFACTURER FOR APPLICATIONS INDICATED. <br />3. PROVIDE SLOTTED, STAND-OFF WASHERS FOR SLIP JOINT ATTACHMENTS. <br />4. REFER TO DETAILS INDICATED IN DRAWINGS. <br />B. SCREWS FOR GYPSUM BOARD AND ACCESSORY APPLICATION: MEETING ASTM C1002-07, <br />CORROSION-RESISTANT. <br />1. FOR APPLICATION OF SINGLE LAYER OR BASE LAYER OF GYPSUM BOARD TO <br />METAL FRAMING: 1", TYPE S, BUGLE HEAD. <br />2. FOR APPLICATION OF FACE LAYER OF GYPSUM BOARD TO METAL FRAMING IN <br />DOUBLE LAYER CONSTRUCTION: 1-5/8", TYPE S, BUGLE HEAD. <br />3. FOR GYPSUM BOARD TO GYPSUM BOARD APPLICATION: 1-1/2", TYPE G, BUGLE <br />HEAD. <br />C. SCREWS FOR GLASS MAT FACED BOARD APPLICATION: CORROSSION RESISTANT SHEET <br />METAL SCREWS WITH HEAD DIAMETER PROVIDING 125 LB. FASTENER PULL-THROUGH <br />AND PULL-OUT RESISTANCE. SCREW LENGTH SHALL PROVIDE 1/4" MINIMUM THREAD <br />ENGAGEMENT. <br />2.5 JOINT MATERIALS AND ADHESIVES: <br />A. STANDARD GYPSUM BOARD PRODUCTS: <br />1. JOINT TAPE: MEETING ASTM C475-12, PERFORATED PAPER TYPE. <br />2. JOINT COMPOUND: MEETING ASTM C475-12, READY-MIXED TAPE EMBEDMENT <br />AND TOPPING COMPOUNDS, VINYL-BASED. <br />B. MOLD AND MOISTURE RESISTANT PAPER FACED GYPSUM BOARD: JOINT TAPE AND JOINT <br />COMPOUND SHALL BE IN ACCORD WITH RECOMMENDATIONS OF BOARD <br />MANUFACTURER'S PRODUCT DATA. <br />2.6 ACCESSORIES: <br />A. ACCESSORIES SHALL COMPLY WITH ASTM C1047-10A <br />B. CORNER REINFORCEMENT: VINYL CORP., "RIGID VINYL DRYWALL & VENEER <br />ACCESSORIES, MODEL CBD125 CORNER BEADS"; LEAD-FREE, VIRGIN VINYL <br />COMPOUNDS CORNER BEADS WITH 1-1/4" X 1-1/4" PERFORATED FLANGES. <br />C. METAL JAMB, CEILING AND CASING TRIM: MANUFACTURER'S STANDARD "L" AND "U" <br />SHAPED GALVANIZED MEMBERS WITH FINE EXPANDED MESH FLANGES; "MUD-IN" TYPE <br />FOR <br />FINISHING WITH JOINT COMPOUNDS. <br />D. TIE WIRE: MINIMUM 18 GA. GALVANIZED, ANNEALED STEEL WIRE. <br />PART 3 - EXECUTION <br />3.1 FRAMING AND FURRING INSTALLATION: <br />A. EXCEPT WHERE MORE STRINGENT REQUIREMENTS ARE SPECIFIED, INSTALL FRAMING <br />AND FURRING IN ACCORD WITH ASTM C754-11, GYPSUM ASSOCIATION REQUIREMENTS <br />AND MANUFACTURER'S PRODUCT DATA. <br />3.2 GENERAL BOARD APPLICATION: <br />A. EXCEPT WHERE MORE STRINGENT REQUIREMENTS ARE SPECIFIED, INSTALL GYPSUM <br />BOARD IN ACCORD WITH ASTM C840-11, GA-216 AND MANUFACTURER'S PRODUCT DATA. <br />C. USE GYPSUM BOARD OF MAXIMUM LENGTHS TO MINIMIZE END JOINTS. STAGGER END <br />JOINTS. <br />D. ABUT GYPSUM BOARDS WITHOUT FORCING. FIT ENDS AND EDGES OF BOARD. DO NOT <br />PLACE BUTT ENDS AGAINST TAPERED EDGES. <br />E. SUPPORT ENDS AND EDGES OF GYPSUM BOARD PANELS ON FRAMING OR FURRING <br />MEMBERS, EXCEPT FOR FACE LAYER OF DOUBLE LAYER WORK. <br />F. INSTALL ACOUSTICAL SEALANT AT SOUND-RATED PARTITIONS: <br />1. SEAL PARTITION PERIMETER WITH CONTINUOUS 1/4" MINIMUM ROUND BEAD OF <br />ACOUSTICAL SEALANT APPLIED TO EACH LEG OF RUNNERS, INCLUDING THOSE <br />USED AT PARTITION INTERSECTIONS WITH DISSIMILAR WALL CONSTRUCTION. <br />2. INSTALL GYPSUM BOARD WITH 1/8" PERIMETER RELIEF COMPRESSING SEALANT <br />TO FORM PERMANENT AIRTIGHT SEAL. <br />3. WHERE SLIP JOINT ATTACHMENTS ARE REQUIRED AT TOP OF PARTITIONS, FILL <br />RESULTING JOINT BETWEEN DRYWALL AND ADJACENT STRUCTURE WITH <br />ACOUSTICAL SEALANT TO FORM PERMANENT AIR TIGHT SEAL. <br />4. APPLY ACOUSTICAL SEALANT AROUND CUTOUTS SUCH AS AT ELECTRICAL <br />BOXES, PLUMBING PENETRATIONS, MEDICINE CABINETS, HEATING DUCTS AND <br />COLD AIR RETURNS TO FORM PERMANENT AIRTIGHT SEAL. (SEALANT SHALL <br />NOT BE USED AS A FIRE STOPPING MATERIAL.) <br />H. INSTALL MOLD-MOISTURE RESISTANT GYPSUM BOARD IN DAMP, MOIST LOCATIONS AND <br />AROUND ALL PLUMBING FIXTURES. <br />I. CONTINUE REQUIRED COMPONENTS OF FIRE-RATED AND ACOUSTICALLY RATED WALL <br />ASSEMBLY TO OVERHEAD STRUCTURE. APPLY JOINT TAPE AND ONE COAT OF COMPOUND <br />TO GYPSUM BOARD JOINTS CONCEALED FROM VIEW IN COMPLETED WORK. <br />J. ALLOWABLE TOLERANCES IN FRAMED GYPSUM BOARD CONSTRUTION. <br />1. POSITION: + - 1/4" MAXIMUM VARIATION FROM DESIGN POSITIOIN. <br />2. ALIGNMENT: 1/8" IN 8'-0"; 1/4" MAXIMUM IN ANY CONTINOUS WALL, LINE OR <br />SURFACE. <br />3. SURFACE PLANE: 1/8" IN 12-0"; 1/16" IN 1'-0", MAXIMUM VARIATION IN TRUE <br />SURFACE PLANE. <br />4. SURFACE SMOOTHNESS: NO JOINT OR FASTENER LOCATION, ROUGHNESS OR <br />BLEMISH DISCERNIBLE AFTER APPLICATION OF FINISH WHEN VIEWED AT ANY <br />ANGLE FROM A DISTANCE OF 5'-0" UNDER OCCUPANCY LIGHTING CONDITIONS, <br />WITH SURFACE PREPARATION AS SPECIFIED IN PAINTING AND COATING <br />SECTION. <br />3.3 JOINT TREATMENT: <br />A. FINISH LEVELS SHALL BE IN ACCORD WITH THE "RECOMMENDED SPECIFICATON: LEVELS <br />OF GYPSUM BOARD FINISH" AS PUBLISHED JOINTLY BY THE GYPSUM ASSOCIATION, <br />AWCI, CISCA, AND PDCA. <br />B. FINISH LEVEL 1; JOINT TREATMENT FOR NON-PUBLIC, NON-SERVICE AREAS TO RECEIVE <br />NO FURTHER FINISH, INCLUDING STORAGE AREAS: APPLY JOINT COMPOUND TO JOINTS <br />AND ANGLES IN GYPSUM BOARD AND EMBED JOINT TAPE. SURFACE SHALL BE FREE OF <br />EXCESS JOINT COMPOUND; TOOL MARKS AND RIDGES ARE ACCEPTABLE. <br />C. FINISH LEVEL 2; JOINT TREATMENT FOR AREAS INDICATED TO RECEIVE NO FURTHER <br />FINISH; APPLY JOINT COMPOUND TO JOINTS, ANGLES, FASTENER HEADS AND <br />ACCESSORIES. EMBED JOINT TAPE. APPLY ONE ADDITIONAL COAT OR COMPOUND OVER <br />TAPE. APPLY ONE COAT OF COMPOUND TO FASTENER DEPRESSIONS. SURFACES SHALL <br />BE FREE OF EXCESS JOINT COMPOUND; TOOL MARKS AND RIDGES ARE ACCEPTABLE. <br />D. FINISH LEVEL 4; JOINT TREATMENT FOR AREAS INDICATED TO RECEIVE SEMI-GLOSS AND <br />EGGSHELL PAINT FINISHES: <br />1. APPLY JOINT COMPOUND TO JOINTS, ANGLES, FASTENER HEADS AND ACCESSORIES. <br /> EMBED JOINT TAPE. APPLY THREE ADDITIONAL COATS OF COMPOUND OVER TAPE, <br /> FEATHEREDGING AND SANDING EACH COAT. <br />2. APPLY MINIMUM OF THREE COATS OF COMPOUND TO FASTENER DEPRESSIONS, <br /> SANDING EACH COAT AND BRINGING TO LEVEL PLANE WITH GYPSUM BOARD SURFACE. <br />3. ALL JOINT COMPOUND SHALL BE FREE OF TOOL MARKS AND RIDGES. <br />END OF SECTION <br />SECTION 09 6516 - RESILIENT SHEET FLOORING <br />PART 1 - GENERAL <br />1.1 REFERENCES <br />1.2.1 ASTM INTERNATIONAL (ASTM) <br />A. ASTM D412: STANDARD TEST METHODS FOR VULCANIZED RUBBER AND <br />THERMOPLASTIC ELASTOMERS—TENSION. <br />B. ASTM D2047: STANDARD TEST METHOD FOR STATIC COEFFICIENT OF FRICTION OF <br />POLISH-COATED FLOOR SURFACES AS MEASURED BY THE JAMES MACHINE. <br />C. ASTM D2240: STANDARD TEST METHOD FOR RUBBER PROPERTY (DUROMETER <br />HARDNESS). <br />D. ASTM D3389: STANDARD TEST METHOD FOR COATED FABRICS ABRASION RESISTANCE <br />(ROTARY PLATFORM ABRADER). <br />E. ASTM E648: STANDARD TEST METHOD FOR CRITICAL RADIANT FLUX OF FLOOR <br />COVERING SYSTEMS USING A RADIANT HEAT ENERGY SOURCE. <br />F. ASTM E662: STANDARD TEST METHOD FOR SPECIFIC OPTICAL DENSITY OF SMOKE <br />GENERATED BY SOLID MATERIALS. <br />G. ASTM E1643: STANDARD PRACTICE FOR SELECTION, DESIGN, INSTALLATION, AND <br />INSPECTION OF WATER VAPOR RETARDERS USED IN CONTACT WITH EARTH OR <br />GRANULAR FILL UNDER CONCRETE SLABS. <br />H. ASTM E1745: STANDARD SPECIFICATION FOR WATER VAPOR RETARDERS USED IN <br />CONTACT WITH SOIL OR GRANULAR FILL UNDER CONCRETE SLABS. <br />I. ASTM F386: STANDARD TEST METHOD FOR THICKNESS OF RESILIENT FLOORING <br />MATERIALS HAVING FLAT SURFACES. <br />J. ASTM F710: STANDARD PRACTICE FOR PREPARING CONCRETE FLOORS TO RECEIVE <br />RESILIENT FLOORING. <br />K. ASTM F925: STANDARD TEST METHOD FOR RESISTANCE TO CHEMICALS OF RESILIENT <br />FLOORING. <br />L. ASTM F970: STANDARD TEST METHOD FOR STATIC LOAD LIMIT. <br />M. ASTM F1344: STANDARD SPECIFICATION FOR RUBBER FLOOR TILE. <br />N. ASTM F1514: STANDARD TEST METHOD FOR MEASURING HEAT STABILITY OF RESILIENT <br />FLOORING BY COLOR CHANGE. <br />O. ASTM F1515: STANDARD TEST METHOD FOR MEASURING LIGHT STABILITY OF RESILIENT <br />FLOORING BY COLOR CHANGE. <br />P. ASTM F1859: STANDARD SPECIFICATION FOR RUBBER SHEET FLOOR COVERING <br />WITHOUT BACKING. <br />Q. ASTM F1869: STANDARD TEST METHOD FOR MEASURING MOISTURE VAPOR EMISSION <br />RATE OF CONCRETE SUBFLOOR USING ANHYDROUS CALCIUM CHLORIDE. <br />R. ASTM F2055: STANDARD TEST METHOD FOR SIZE AND SQUARENESS OF RESILIENT <br />FLOOR TILE BY DIAL GAGE METHOD. <br />S. ASTM F2170: STANDARD TEST METHOD FOR DETERMINING RELATIVE HUMIDITY IN <br />CONCRETE FLOOR SLABS USING IN SITU PROBES. <br />T. ASTM F2199: STANDARD TEST METHOD FOR DETERMINING DIMENSIONAL STABILITY OF <br />RESILIENT FLOOR TILE AFTER EXPOSURE TO HEAT. <br />1.2.2 STATE OF CALIFORNIA (CA) <br />A. STANDARD METHOD FOR THE TESTING AND EVALUATION OF VOLATILE ORGANIC <br />COMPOUND EMISSIONS FROM INDOOR SOURCES USING ENVIRONMENTAL CHAMBERS. <br />1.3 ACTION SUBMITTALS <br />A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT, PROVIDE MANUFACTURER’S CURRENT <br />BASE SURFACE PREPARATION GUIDELINES AND MANUFACTURER’S CURRENT <br />INSTALLATION GUIDELINES FOR PRODUCTS SUPPLIED. <br />B. SAMPLES: FOR EACH EXPOSED PRODUCT AND FOR EACH COLOR, TEXTURE, AND <br />PATTERN SPECIFIED. <br />1.4 CLOSEOUT SUBMITTALS <br />A. MAINTENANCE DATA. <br />1.5 QUALITY ASSURANCE <br />A. INSTALLER QUALIFICATIONS: AN ENTITY THAT EMPLOYS INSTALLERS AND <br />SUPERVISORS WHO ARE COMPETENT IN TECHNIQUES REQUIRED BY MANUFACTURER <br />FOR RESILIENT SHEET FLOORING INSTALLATION AND SEAMING METHOD INDICATED. <br />1. ENGAGE AN INSTALLER WHO EMPLOYS WORKERS FOR THIS PROJECT WHO <br />ARE TRAINED OR CERTIFIED BY RESILIENT SHEET FLOORING MANUFACTURER <br />FOR INSTALLATION TECHNIQUES REQUIRED. <br />2. INSTALLER MUST HAVE PERFORMED INSTALLATIONS OF THE SAME SCALE IN <br />THE LAST THREE (3) YEARS. <br />PART 2 - PRODUCTS <br />2.1 PERFORMANCE REQUIREMENTS <br />A. FIRE-TEST-RESPONSE CHARACTERISTICS: FOR RESILIENT SHEET FLOORING, AS <br />DETERMINED BY TESTING IDENTICAL PRODUCTS ACCORDING TO ASTM E 648 OR <br />NFPA 253 BY A QUALIFIED TESTING AGENCY. <br />1. CRITICAL RADIANT FLUX CLASSIFICATION: CLASS I, NOT LESS THAN <br />0.45 W/SQ. CM. <br />2.2 UNBACKED RUBBER SHEET FLOORING <br />A. ACCEPTABLE MANUFACTURERS: <br />1. SEE FINISH LIST FOR SPECIFIED PRODUCT <br />3. NO SUBSTITUTES WILL BE ACCEPTED. <br />B. PRODUCT STANDARD: ASTM F1859. <br />1. TYPE: RUBBER SHEET FLOOR COVERING <br />2. THICKNESS: PER FINISH LIST <br />3. HARDNESS: MANUFACTURER'S STANDARD HARDNESS, MEASURED USING SHORE, <br />TYPE A DUROMETER PER ASTM D 2240. <br />C. WEARING SURFACE: SMOOTH <br />D. SEAMLESS-INSTALLATION METHOD: CHEMICALLY BONDED (COLD WELD). <br />E. COLORS AND PATTERNS: PER SECTION 2.2-A <br />2.3 INSTALLATION MATERIALS <br />A. TROWELABLE LEVELING AND PATCHING COMPOUNDS: LATEX-MODIFIED, PORTLAND- <br />CEMENT-BASED OR BLENDED HYDRAULIC-CEMENT-BASED FORMULATION PROVIDED OR <br />APPROVED BY RESILIENT SHEET FLOORING MANUFACTURER FOR APPLICATIONS <br />INDICATED. <br />B. ADHESIVES: WATER-RESISTANT TYPE RECOMMENDED BY FLOORING AND ADHESIVE <br />MANUFACTURERS TO SUIT RESILIENT SHEET FLOORING AND SUBSTRATE CONDITIONS <br />INDICATED. <br />1. CONTRACTOR SHALL PROVIDE ADHESIVE BACKING OF ENVIROSTIX (MONDO) <br />OR NTX (NORA) AS A COST PROPOSAL FOR THE OWNER’S REVIEW. CONTRACTOR <br />SHALL PERFORM MOISTURE TESTING IN ACCORDANCE WITH THE PROJECT <br />SCHEDULE TO ALLOW FOR THE NECESSARY ADDITIONAL LEAD TIME FOR <br />BACKING APPLICATIONS. <br />C. SEAMLESS-INSTALLATION ACCESSORIES: <br />1. CHEMICAL-BONDING COMPOUND: MANUFACTURER'S PRODUCT FOR CHEMICALLY <br />BONDING SEAMS. <br />D. BASE ACCESSORIES: <br />1. TOP SET RUBBER WALL BASE. COLOR AND MANUFACTURER TO MATCH (E) IN <br />AREA OF WORK. <br />PART 3 - EXECUTION <br />3.1 PREPARATION <br />A. PREPARE SUBSTRATES ACCORDING TO RESILIENT SHEET FLOORING MANUFACTURER'S <br />WRITTEN INSTRUCTIONS TO ENSURE ADHESION OF RESILIENT SHEET FLOORING. <br />B. CONCRETE SUBSTRATES: PREPARE ACCORDING TO ASTM F 710. <br />1. VERIFY THAT SUBSTRATES ARE DRY AND FREE OF CURING COMPOUNDS, <br />SEALERS, AND HARDENERS. <br />2. REMOVE SUBSTRATE COATINGS AND OTHER SUBSTANCES THAT ARE <br />INCOMPATIBLE WITH ADHESIVES AND THAT CONTAIN SOAP, WAX, OIL, OR <br />SILICONE, USING MECHANICAL METHODS RECOMMENDED BY RESILIENT SHEET <br />FLOORING MANUFACTURER. DO NOT USE SOLVENTS. <br />3. ALKALINITY AND ADHESION TESTING: PERFORM TESTS RECOMMENDED BY <br />RESILIENT SHEET FLOORING MANUFACTURER. PROCEED WITH INSTALLATION <br />ONLY AFTER SUBSTRATE ALKALINITY FALLS WITHIN RANGE ON PH SCALE <br />RECOMMENDED BY MANUFACTURER IN WRITING, BUT NOT LESS THAN 5 <br />OR MORE THAN 9 PH. <br />4. MOISTURE TESTING: PERFORM TESTS SO THAT EACH TEST AREA DOES NOT <br />EXCEED 1000 SQ. FT. AND PERFORM NO FEWER THAN THREE TESTS IN EACH <br />INSTALLATION AREA AND WITH TEST AREAS EVENLY SPACED IN INSTALLATION <br />AREAS. <br />A. ANHYDROUS CALCIUM CHLORIDE TEST: ASTM F 1869. PROCEED WITH <br />INSTALLATION ONLY AFTER SUBSTRATES HAVE MAXIMUM MOISTURE- <br />VAPOR-EMISSION RATE OF 3 LB OF WATER/1000 SQ. FT. <br />B. RELATIVE HUMIDITY TEST: USING IN-SITU PROBES, ASTM F 2170. <br />PROCEED WITH INSTALLATION ONLY AFTER SUBSTRATES HAVE A <br />MAX. 85 PERCENT RELATIVE HUMIDITY LEVEL MEASUREMENT. <br />C. FILL CRACKS, HOLES, AND DEPRESSIONS IN SUBSTRATES WITH <br />TROWELABLE LEVELING AND PATCHING COMPOUND; REMOVE BUMPS <br />AND RIDGES TO PRODUCE A UNIFORM AND SMOOTH SUBSTRATE. <br />D. DO NOT INSTALL RESILIENT SHEET FLOORING UNTIL MATERIALS ARE <br />THE SAME TEMPERATURE AS SPACE WHERE THEY ARE TO BE INSTALLED. <br />1. AT LEAST 48 HOURS IN ADVANCE OF INSTALLATION, MOVE <br />FLOORING AND INSTALLATION MATERIALS INTO SPACES <br />WHERE THEY WILL BE INSTALLED. <br />E. IMMEDIATELY BEFORE INSTALLATION, SWEEP AND VACUUM CLEAN <br />SUBSTRATES TO BE COVERED BY RESILIENT SHEET FLOORING. <br />3.2 RESILIENT SHEET FLOORING INSTALLATION <br />A. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS FOR INSTALLING RESILIENT <br />SHEET FLOORING. <br />B. UNROLL RESILIENT SHEET FLOORING AND ALLOW IT TO STABILIZE BEFORE CUTTING <br />AND FITTING. <br />C. LAY OUT RESILIENT SHEET FLOORING AS FOLLOWS: <br />1. MAINTAIN UNIFORMITY OF FLOORING DIRECTION. <br />2. MINIMIZE NUMBER OF SEAMS; PLACE SEAMS IN INCONSPICUOUS AND <br />LOW-TRAFFIC AREAS, AT LEAST 6 INCHES (152 MM) AWAY FROM PARALLEL <br />JOINTS IN FLOORING SUBSTRATES. <br />3. MATCH EDGES OF FLOORING FOR COLOR SHADING AT SEAMS. <br />4. AVOID CROSS SEAMS. <br />D. SCRIBE AND CUT RESILIENT SHEET FLOORING TO BUTT NEATLY AND TIGHTLY TO VERTICAL <br />SURFACES AND PERMANENT FIXTURES INCLUDING BUILT-IN FURNITURE, CABINETS, PIPES, <br />OUTLETS, AND DOOR FRAMES. <br />E. EXTEND RESILIENT SHEET FLOORING INTO TOE SPACES, DOOR REVEALS, CLOSETS, AND <br />SIMILAR OPENINGS. <br />F. MAINTAIN REFERENCE MARKERS, HOLES, AND OPENINGS THAT ARE IN PLACE OR MARKED <br />FOR FUTURE CUTTING BY REPEATING ON RESILIENT SHEET FLOORING AS MARKED ON <br />SUBSTRATES. USE CHALK OR OTHER NONPERMANENT MARKING DEVICE. <br />G. INSTALL RESILIENT SHEET FLOORING ON COVERS FOR TELEPHONE AND ELECTRICAL <br />DUCTS AND SIMILAR ITEMS IN INSTALLATION AREAS. MAINTAIN OVERALL CONTINUITY OF <br />COLOR AND PATTERN BETWEEN PIECES OF FLOORING INSTALLED ON COVERS AND <br />ADJOINING FLOORING. TIGHTLY ADHERE FLOORING EDGES TO SUBSTRATES THAT ABUT <br />COVERS AND TO COVER PERIMETERS. <br />H. ADHERE RESILIENT SHEET FLOORING TO SUBSTRATES USING A FULL SPREAD OF <br />ADHESIVE APPLIED TO SUBSTRATE TO PRODUCE A COMPLETED INSTALLATION WITHOUT <br />OPEN CRACKS, VOIDS, RAISING AND PUCKERING AT JOINTS, TELEGRAPHING OF ADHESIVE <br />SPREADER MARKS, AND OTHER SURFACE IMPERFECTIONS. <br />I. SEAMLESS INSTALLATION: <br />1. CHEMICALLY BONDED SEAMS: BOND SEAMS WITH CHEMICAL-BONDING <br />COMPOUND TO FUSE SECTIONS PERMANENTLY INTO A SEAMLESS FLOORING <br />INSTALLATION. PREPARE SEAMS AND APPLY COMPOUND TO PRODUCE TIGHTLY <br />FITTED SEAMS WITHOUT GAPS, OVERLAYS, OR EXCESS BONDING COMPOUND <br />ON FLOORING SURFACES. <br />END OF SECTION <br />SECTION 08 34 00 – SPECIAL FUNCTION DOORS <br />PART 1 GENERAL <br />1.01 RELATED DOCUMENTS <br />A. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND <br />SUPPLEMENTARY CONDITIONS AND DIVISION 01 SPECIFICATION SECTIONS, APPLY TO THIS <br />SECTION. <br />1.02 SUMMARY <br />A. SECTION INCLUDES: <br />1. ALUMINUM SLIDING DOOR AND SIDELITE FRAMING SYSTEM FOR INTERIOR USE. <br />B. RELATED SECTIONS: <br />1. SECTION 08 14 16 – FLUSH WOOD DOOR <br />2. SECTION 08 13 16 – ALUMINUM DOORS <br />1.03 REFERENCES <br />A. ANSI – AMERICAN NATIONAL STANDARDS INSTITUTE <br />1. ANSI 156.18 MATERIALS AND FINISHES <br />2. ANSI A117.1 SPECIFICATIONS FOR MAKING BUILDINGS AND FACILITIES USABLE BY <br />PHYSICALLY HANDICAPPED PEOPLE. <br />B. BHMA – BUILDERS HARDWARE MANUFACTURERS ASSOCIATION <br />C. DHI – DOOR AND HARDWARE INSTITUTE <br />D. NFPA – NATIONAL FIRE PROTECTION ASSOCIATION <br />1. NFPA 80 – FIRE DOORS AND WINDOWS <br />2. NFPA 101 – LIFE SAFETY CODE <br />3. NFPA 105 – SMOKE AND DRAFT CONTROL DOOR ASSEMBLIES <br />4. NFPA 252 – FIRE TESTS OF DOORS ASSEMBLIES <br />E. AWS – ARCHITECTURAL WOODWORK STANDARDS <br />1.04 SUBMITTALS <br />A. COMPLY WITH SECTION 01 33 00 – SUBMITTAL PROCEDURES <br />B. PRODUCT DATA: SUBMIT MANUFACTURER’S PRODUCT DATA, INCLUDING INSTALLATION <br />INSTRUCTIONS. <br />C. SHOP DRAWINGS: SUBMIT MANUFACTURER’S SHOP DRAWINGS, INCLUDING PLANS, <br />ELEVATIONS, SECTIONS, AND DETAILS, INDICATING DIMENSIONS, TOLERANCES, MATERIALS, <br />COMPONENTS, HARDWARE, FINISH, OPTIONS, AND ACCESSORIES. SHOP DRAWINGS TO SHOW <br />REQUIRED BLOCKING BY OTHERS. <br />D. SAMPLES: SUBMIT MANUFACTURER’S SAMPLES OF THE FOLLOWING SLIDING DOOR <br />COMPONENTS: <br />1. DOOR VENEER OR LAMINATE SAMPLE. <br />2. ALUMINUM FRAME FINISH SAMPLE. <br />B. MANUFACTURER’S CERTIFICATION: SUBMIT MANUFACTURER’S CERTIFICATION THAT <br />MATERIALS COMPLY WITH SPECIFIED REQUIREMENTS AND ARE SUITABLE FOR INTENDED <br />APPLICATION. <br />C. WARRANTY DOCUMENTATION: SUBMIT MANUFACTURER’S STANDARD WARRANTY. <br />1.02 QUALITY ASSURANCE <br />A. PRODUCT OPTIONS: DRAWINGS INDICATE SIZE, PROFILES, AND DIMENSIONAL <br />REQUIREMENTS OF INTERIOR ALUMINUM FRAMES AND DOORS. <br />B. SOURCE: OBTAIN SLIDING ALUMINUM FRAMED DOORS AND HARDWARE FROM SINGLE <br />SOURCE. <br />C. MANUFACTURER'S QUALIFICATIONS: MANUFACTURER REGULARLY ENGAGED FOR PAST 5 <br />YEARS IN MANUFACTURE OF SLIDING DOORS SIMILAR TO THAT SPECIFIED. <br />1.03 PERFORMANCE <br />A. ALUMINUM PERIMETER FRAMES WITH INTEGRAL ACOUSTIC SEALS AT ALL DOOR/FRAME <br />INTERFACES <br />1. ARCHITECT TO VERIFY FRAME THICKNESS SUITABLE FOR REQUIRED APPLICATION <br />B. SOFT CLOSING DAMPENER AT BOTH SIDES OF DOOR INTEGRATED WITH TOP TRACK. <br />DEMONSTRATE SOFT CLOSERS TESTED TO A MINIMUM OF 150,000 CYCLES. <br />C. CONCEALED DOOR GUIDE. <br />D. MANUFACTURER TO SUBMIT 3RD PARTY TEST DATA ON AIR INFILTRATION AND/OR SMOKE <br />RATINGS AS APPLICABLE <br />1.04 DELIVERY, STORAGE, AND HANDLING <br />A. DELIVERY AND ACCEPTANCE REQUIREMENTS: DELIVER MATERIALS TO SITE IN <br />MANUFACTURER’S ORIGINAL, UNOPENED CONTAINERS AND PACKAGING, WITH LABELS CLEARLY <br />IDENTIFYING PRODUCT NAME AND MANUFACTURER. <br />B. NOTIFY MANUFACTURER IMMEDIATELY OF ANY SHIPPING DAMAGE. <br />C. STORAGE AND HANDLING REQUIREMENTS: <br />1. STORE AND HANDLE MATERIALS IN ACCORDANCE WITH MANUFACTURER’S INSTRUCTIONS. <br />2. KEEP MATERIALS IN MANUFACTURER’S ORIGINAL, UNOPENED CONTAINERS AND <br />PACKAGING UNTIL INSTALLATION. <br />3. STORE MATERIALS IN CLEAN, DRY AREA INDOORS. <br />4. PROTECT MATERIALS AND FINISH DURING STORAGE, HANDLING, AND INSTALLATION TO <br />PREVENT DAMAGE. <br />PART 1 - PRODUCTS <br />1.01 MANUFACTURERS <br />A. AD SYSTEMS 2201 100TH ST. SW, EVERETT, WA 98204 | WEBSITE: <br />HTTP://SPECADSYSTEMS.COM | PHONE: 425-740-6011 | ADSYSTEMS.ESTIMATING@ALLEGION.COM <br />1.02 INTERIOR SLIDING ALUMINUM-FRAMED DOORS AND PARTITIONS <br />A. MANUFACTURER: <br />1. SCHEDULED MANUFACTURER: INSETSLIDE™ HIGH PERFORMANCE BARN (SLIDING) DOOR <br />SYSTEM BY AD SYSTEMS. <br />2. ACCEPTABLE SUBSTITUTE: NO SUBSTITUTION. <br />B. SPECIFIED WALL THICKNESS: SEE PARTITIONS TYPES <br />C. FRAME PROFILES: EXTRUDED ALUMINUM FRAME “WRAP” FRAME WITH INTEGRAL VERTICAL <br />JAMB (STILE POCKET). <br />D. FINISH: STANDARD HARDCOAT (KYNAR) FINISH IN LIGHT SEQUIN <br />1. STANDARD: PAINTED HARDCOAT (KYNAR) FINISH. MEETS AAMA 2604 STANDARD COLORS. <br />2. CUSTOM PAINTED HARDCOAT (KYANAR) FINISH <br />E. DOOR LEAFS: ALL DOORS TO BE FACTORY MACHINED FOR HARDWARE INCLUDING PILOT <br />AND FUNCTION HOLES <br />1. 1-3/4" FLUSH WOOD DOOR: SOLID TIMBER-STRAND CORE. <br />A. OPTIONAL GLAZING: MONOLITHIC CLEAR TEMPERED <br />B. STANDARD STILE WIDTHS ARE 6” WITH A 10” BOTTOM RAIL. <br />2. ALUMINUM STILE & RAIL DOOR: MANUFACTURER’S STANDARD 1-3/4 INCH THICK GLAZED <br />DOORS WITH EXTRUDED-ALUMINUM TUBULAR STILE AND RAIL MEMBERS. WELDED AND BOLTED <br />CORNER CONNECTIONS. <br />A. 3-1/2 INCH VERTICAL STILES PLUS 1/2 INCH STOP. <br />B. 3-1/2 INCH HORIZONTAL STILES PLUS 1/2 INCH STOP <br />C. OPTIONAL: 10” BOTTOM RAIL. <br />D. GLAZING: MONOLITHIC CLEAR TEMPERED <br />3. OTHER 1-3/4” DOORS. CONTACT AD SYSTEMS. <br />B. DOOR COMPONENTS <br />1. SINGLE TOP TRACK: AD SYSTEMS EXTRUDED ALUMINUM TRACK BY AD SYSTEMS <br />3. TOP ROLLERS: TANDEM NYLON ROLLER SIZED TO MATCH DOOR WEIGHT <br />4. CONCEALED FLOOR GUIDE: INTEGRAL JAMB FLOOR GUIDE BY AD SYSTEMS <br />5. SOFT-CLOSER: SOFT-CLOSING DAMPENER MECHANISM AT BOTH SIDES OF DOOR LEAF. <br />DEMONSTRATE SOFT CLOSER AS HAVING BEEN TESTED TO 150K CYCLES. <br />6. PULL HANDLES: <br />A. AD SYSTEMS STANDARD LADDER PULL: 16” LONG X 1” DIAMETER. FINISH: US32D <br />SATIN STAINLESS STEEL. <br />B. AD SYSTEMS STANDARD STRAIGHT PULL: 12” LONG X 1” DIAMETER. FINISH: US32D <br />SATIN STAINLESS STEEL. <br />C. FLUSH PULL AND CUSTOM PULL HANDLE BY REQUEST. <br />G. DOOR LOCKS: MAGNETIC LOCK BY AD SYSTEMS <br />B. SELF-CLOSING SPRING MECHANISM <br />C. AUTOMATIC DOOR BOTTOM FOR IMPROVED ACOUSTICAL PERFORMANCE <br />D. SYNCHRONAL DOOR DRIVE FOR BI-PARTING PAIRS OF DOORS. <br />E. ADDITIONAL HARDWARE FUNCTIONALITY CAN BE ACCOMMODATED. PLEASE CONTACT AD <br />SYSTEMS WITH YOUR HARDWARE REQUIREMENTS AND WE EVALUATE SYSTEM COMPATIBILITY AND <br />CREATE SPECIFICATION LANGUAGE. <br />PART 2 - EXECUTION <br />2.01 EXAMINATION <br />A. EXAMINE WALL OPENINGS TO RECEIVE SLIDING DOORS FOR PLUMB, LEVEL, AND SQUARE. <br />NOTE: FINISH DOOR OPERATION WILL BE AFFECTED BY OUT OF TOLERANCE FRAMING. <br />B. VERIFY DIMENSIONS OF WALL OPENINGS. <br />C. EXAMINE SURFACES TO RECEIVE TOP AND BOTTOM GUIDE. <br />D. NOTIFY ARCHITECT OF CONDITIONS THAT WOULD ADVERSELY AFFECT INSTALLATION OR <br />SUBSEQUENT USE OF SLIDING DOORS. <br />E. DO NOT BEGIN INSTALLATION UNTIL UNACCEPTABLE CONDITIONS ARE CORRECTED. <br />F. BASE OF DOOR SIDE TO BE FLUSH OR MINIMAL. RUBBER BASE ACCEPTABLE. <br />1.01 INSTALLATION <br />A. INSTALL SLIDING DOORS IN ACCORDANCE WITH MANUFACTURER’S INSTRUCTIONS AT <br />LOCATIONS INDICATED ON THE DRAWINGS. <br />B. INSTALL SLIDING DOORS PLUMB, LEVEL, SQUARE, AND IN PROPER ALIGNMENT. <br />C. INSTALL SLIDING DOORS TO CLOSE AGAINST WALLS WITHOUT GAPS. <br />D. INSTALL SLIDING DOORS TO OPEN AND CLOSE SMOOTHLY. <br />E. ANCHOR SLIDING DOORS SECURELY IN PLACE TO SUPPORTS. REQUIRED: FIRE TREATED 2 <br />X 6 BLOCKING REQUIRED FULL LENGTH OF TRACK. <br />1.02 ADJUSTING <br />A. ADJUST SLIDING DOORS FOR PROPER OPERATION IN ACCORDANCE WITH <br />MANUFACTURER’S INSTRUCTIONS. <br />B. ADJUST SLIDING DOORS TO OPERATE SMOOTHLY WITHOUT BINDING. <br />C. REPAIR MINOR DAMAGES TO FINISH IN ACCORDANCE WITH MANUFACTURER’S <br />INSTRUCTIONS AND AS APPROVED BY ARCHITECT. <br />1.03 CLEANING <br />A. CLEAN SLIDING DOORS PROMPTLY AFTER INSTALLATION IN ACCORDANCE WITH <br />MANUFACTURER’S INSTRUCTIONS. <br />B. DO NOT USE HARSH CLEANING MATERIALS OR METHODS THAT COULD DAMAGE <br />MATERIALS OR FINISH. <br />1.04 PROTECTION <br />A. PROTECT INSTALLED SLIDING DOORS FROM DAMAGE DURING CONSTRUCTION. <br />END OF SECTION <br />R <br />No. <br />F <br />LICENSE <br />STATE <br />D <br />O <br />A RCHITECT <br />C AL IFORNIA <br />STEPHE WHITE <br />RENEWAL <br />DATE <br />C-34829 <br />N <br />08/31/27 <br />SHEET TITLE <br />PROJECT <br />FACILITY <br />FAC NO: BLDG NO: FLOOR LEV: SECTION: <br />KP PROJ. NO. <br />PERMIT NO. <br />555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA <br />ARCHITECT <br />CONSULTANT <br />ARCHITECT SEAL CONSULTANT SEAL <br />KAISER FOUNDATION HOSPITALS <br />NATIONAL FACILITIES SERVICES <br />1800 HARRISON STREET OAKLAND, <br />CALIFORNIA 94612 <br />ISSUE / REVISION LOG <br />NO. ISSUED DATE <br />0 <br />5' <br /> <br />5 <br />0 <br />' <br />GR <br />A <br />P <br />H <br />I <br />C <br /> <br />S <br />C <br />A <br />L <br />E <br />S <br />: <br /> <br />1 <br />/ <br />1 <br />6 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />0 <br />25 <br />' <br />1/ <br />8 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />5' <br />0 <br />12 <br />' <br />1/ <br />4 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />1' <br />0 <br />6' <br />1/ <br />2 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />1' <br />0 <br />2' <br />1- <br />1 <br />/ <br />2 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />0 <br />1' <br />3" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />IF <br /> <br />T <br />H <br />I <br />S <br /> <br />S <br />H <br />E <br />E <br />T <br /> <br />I <br />S <br /> <br />N <br />O <br />T <br /> <br />30 <br />" <br />x <br />4 <br />2 <br />" <br />, <br /> <br />I <br />T <br /> <br />I <br />S <br /> <br />A <br /> <br />R <br />E <br />D <br />U <br />C <br />E <br />D <br /> <br />PR <br />I <br />N <br />T <br /> <br />- <br /> <br />S <br />C <br />A <br />L <br />E <br /> <br />AC <br />C <br />O <br />R <br />D <br />I <br />N <br />G <br />L <br />Y <br />AGENCY APPLICATION NUMBER <br />AGENCY APPROVAL STAMP <br />THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS <br />NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. <br />HZ PROJ. NO. <br />www.huitt-zollars.com <br />Phone 310.820.4600 | Fax 310.207.4215 <br />C: <br />\ <br />U <br />s <br />e <br />r <br />s <br />\ <br />l <br />r <br />o <br />b <br />i <br />n <br />s <br />o <br />n <br />\ <br />O <br />n <br />e <br />D <br />r <br />i <br />v <br />e <br /> <br />- <br /> <br />H <br />u <br />i <br />t <br />t <br />- <br />Z <br />o <br />l <br />l <br />a <br />r <br />s <br />, <br /> <br />I <br />n <br />c <br />\ <br />D <br />o <br />cu <br />m <br />e <br />n <br />t <br />s <br />\ <br />R <br />3 <br />1 <br />4 <br />4 <br />1 <br />2 <br />. <br />3 <br />5 <br /> <br />K <br />P <br /> <br />H <br />B <br />M <br /> <br />K <br />P <br />O <br />J <br />_ <br />A <br />2 <br />4 <br />_ <br />l <br />r <br />o <br />b <br />i <br />n <br />s <br />o <br />n <br />L <br />2 <br />M <br />D <br />X <br />. <br />r <br />vt <br />1 <br />1 <br />/ <br />3 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />3 <br />: <br />4 <br />4 <br />: <br />0 <br />2 <br /> <br />P <br />M <br />SOCC 2022 R HBM 1st Fl KPOJ <br />REMODEL <br />G0-03 <br />SPECIFICATIONS <br />CA394-1 - <br />CAP027721R314412.35 <br />HARBOR/MacARTHUR MEDICAL OFF <br />3401 S. HARBOR BLVD. <br />SANTA ANA, CALIFORNIA 92704 <br />N/ASPECIFICATIONS - DIVISION 9 09 <br />CITY SUBMITTAL 11/03/2025 <br />101125520, 20187249, 40140902