SPECIFICATIONS TABLE OF CONTENTS <br />1. MANUFACTURERS: <br />a. O-Z/GEDNEY CO. <br />b. THOMAS & BETTS <br />c. APPLETON ELECTRIC <br />d. ELECTROLINE <br />e. BRIDGEPORT <br />f. MIDWEST <br />g. REGAL <br />h. ORBIT INDUSTRIES <br />i. OR APPROVED EQUAL. <br />2.4 LIQUIDTIGHT FLEXIBLE METALLIC CONDUIT (LFMC) AND FITTINGS <br />A. MANUFACTURERS: <br />1. ANACONDA TYPE UA <br />2. ELECTRI-FLEX TYPE LA <br />3. ALFLEX <br />4. CARLON (LAMSON & SESSIONS) <br />5. OR APPROVED EQUAL. <br />B.CONSTRUCTION: FLEXIBLE STEEL, APPROVED FOR CONDUIT GROUND, ZINC COATED, <br /> THREADLESS TYPE FORMED FROM A CONTINUOUS LENGTH OF SPIRALLY WOUND, <br /> INTERLOCKED ZINC COATED STRIP STEEL AND AN EXTRUDED PVC COVER. <br />C.FITTINGS AND CONDUIT BODIES: <br />1. WATERTIGHT, COMPRESSION TYPE, GALVANIZED ZINC COATED CADMIUM PLATED <br />MALLEABLE CAST IRON, UL LISTED. <br />2. FITTINGS AND CONDUIT BODIES SHALL INCLUDE PLASTIC OR CAST METAL INSERTS <br />SUPPLIED BY THE MANUFACTURER TO PROTECT CONDUCTORS FROM SHARP EDGES. <br />3. MANUFACTURERS: <br />a. APPLETON ELECTRIC <br />b. O-Z/GEDNEY CO. <br />c. ELECTROLINE <br />d. BRIDGEPORT <br />e. THOMAS & BETTS <br />f. MIDWEST <br />g. REGAL <br />h. CARLON (LAMSON & SESSIONS) <br />i. ORBIT INDUSTRIES <br />j. OR APPROVED EQUAL. <br />2.5 OUTLET BOXES <br />A. SHEET METAL OUTLET BOXES: ANSI/NEMA OS 1; GALVANIZED STEEL, 16 GAUGE <br />(APPROXIMATELY 0.0625 INCHES), WITH 1/2-INCH MALE FIXTURE STUDS WHERE REQUIRED. <br />B. CAST BOXES: NEMA FB1, TYPE FD, ALUMINUM, CAST FERALLOY, OR STAINLESS STEEL DEEP <br />TYPE, GASKETED COVER, THREADED HUBS. <br />C. OUTLET BOXES FOR LUMINAIRES TO BE NOT LESS THAN 1-1/2" DEEP, DEEPER IF REQUIRED BY <br />THE NUMBER OF WIRES OR CONSTRUCTION. THE BOX SHALL BE COORDINATED WITH SURFACE <br />LUMINAIRES TO CONCEAL THE BOX FROM VIEW OR PROVIDE A FINISHED TRIM PLATE. <br />D. SWITCH OUTLET BOXES FOR LOCAL LIGHT CONTROL SWITCHES, DIMMERS AND OCCUPANCY <br />SENSORS SHALL BE 4 INCHES SQUARE BY 2-1/8 INCHES DEEP, WITH RAISED COVER TO FIT <br />FLUSH WITH FINISH WALL LINE. MULTIPLE GANG SWITCH OUTLETS SHALL CONSIST OF THE <br />REQUIRED NUMBER OF GANG BOXES APPROPRIATE TO THE QUANTITY OF SWITCHES <br />COMPRISING THE GANG. WHERE WALLS ARE PLASTERED, PROVIDE A PLASTER RAISED COVER. <br />WHERE SWITCH OUTLET BOXES OCCUR IN EXPOSED CONCRETE BLOCK WALLS, BOXES SHALL <br />BE INSTALLED IN THE BLOCK CAVITY WITH A RAISED SQUARE EDGE TILE COVER OF SUFFICIENT <br />DEPTH TO EXTEND OUT TO FACE OF BLOCK OR MASONRY BOXES. <br />E. OUTLET BOXES FOR TECHNOLOGY ROUGH-INS IN WALLS AND COLUMNS SHALL BE 4-11/16 <br />INCHES SQUARE AND 2-1/8 INCHES DEEP WITH SINGLE GANG RAISED COVER TO FIT FLUSH <br />WITH FINISHED WALL LINE EQUIPPED WITH FLUSH PLATE. <br />F. WALL OR COLUMN RECEPTACLE OUTLET BOXES SHALL BE 4 INCHES SQUARE WITH RAISED <br />COVER TO FIT FLUSH WITH FINISHED WALL LINE. BOXES IN CONCRETE BLOCK WALLS SHALL BE <br />INSTALLED THE SAME AS FOR SWITCH BOXES IN BLOCK WALLS. <br />2.6 ECONN; ELECTRICAL CONNECTION <br />A. ELECTRICAL CONNECTION TO EQUIPMENT AND MOTORS, SIZED PER ELECTRICAL CODE. <br />COORDINATE REQUIREMENTS WITH CONTRACTOR FURNISHING EQUIPMENT OR MOTOR. REFER <br />TO SPECIFICATIONS AND GENERAL INSTALLATION NOTES FOR TERMINATIONS TO MOTORS. <br />2.7 JB; PULL AND JUNCTION BOXES <br />A. SHEET METAL BOXES: ANSI/NEMA OS 1; GALVANIZED STEEL. <br />B. SHEET METAL BOXES LARGER THAN 12 INCHES IN ANY DIMENSION THAT CONTAIN <br />TERMINATIONS OR COMPONENTS: CONTINUOUS HINGED ENCLOSURE WITH 1/4 TURN LATCH <br />AND WHITE BACK PANEL FOR MOUNTING TERMINAL BLOCKS AND ELECTRICAL COMPONENTS. <br />C. FLANGED TYPE BOXES SHALL BE USED WHERE INSTALLED FLUSH IN WALL. <br />2.8 ROUGH-IN <br />A. PROVIDE WITH ONE (1) FLUSH MOUNT DOUBLE GANG BOX WITH SINGLE GANG PLASTER RING <br />AND APPROPRIATE COVER PLATE, <br />B. CONDUIT STUBBED TO ABOVE THE LAY-IN CEILING. <br />C. RI-TECH; TECHNOLOGY ROUGH-IN: <br />1. ROUGH-IN SHALL HAVE ONE (1) 1" CONDUIT. <br />D.RI-TECH-W; TECHNOLOGY ROUGH-IN -WALL PHONE: <br />1. MOUNT ON WALL +54" OR AS NOTED IN PLANS. ROUGH-IN SHALL HAVE ONE (1) 1" CONDUIT. <br />E.RI-TECH-C; TECHNOLOGY ROUGH-IN -CEILING FLUSH MOUNTED: <br />1. MOUNT FLUSH IN FINISHED CEILING OR AS NOTED IN PLANS. ROUGH-IN SHALL HAVE ONE (1) <br />1" CONDUIT. <br />2.9 ACCESSORIES <br />A. FIRE RATED MOLDABLE PADS: UL #9700, MOLDABLE SHEET PUTTY AT REQUIRED THICKNESS ON <br />ALL FIVE SIDES OF BACK BOXES. KINETICS NOISE CONTROL -ISOBACKER PAD, SPECSEAL -SSP <br />PUTTY AND PADS, 3M #MPP-4S OR EQUAL. <br />PART 3 -EXECUTION <br />3.1 CONDUIT INSTALLATION SCHEDULE AND SIZING <br />A. IN THE EVENT THE LOCATION OF CONDUIT INSTALLATION REPRESENTS CONFLICTING <br />INSTALLATION REQUIREMENTS AS SPECIFIED IN THE FOLLOWING SCHEDULE, A CLARIFICATION <br />SHALL BE OBTAINED FROM THE ARCHITECT/ENGINEER. IF THIS CONTRACTOR IS UNABLE TO <br />OBTAIN A CLARIFICATION AS OUTLINED ABOVE, CONCEALED RIGID GALVANIZED STEEL <br />CONDUIT INSTALLED PER THESE SPECIFICATIONS AND THE ELECTRICAL CODE SHALL BE <br />REQUIRED. <br />B. INSTALLATION SCHEDULE: REFER TO DRAWINGS. <br />C. SIZE CONDUIT AS SHOWN ON THE DRAWINGS AND SPECIFICATIONS. WHERE NOT INDICATED IN <br />THE CONTRACT DOCUMENTS, CONDUIT SIZE SHALL BE ACCORDING TO THE ELECTRICAL CODE. <br />CONDUIT AND CONDUCTOR SIZING SHALL BE COORDINATED TO LIMIT CONDUCTOR FILL TO <br />LESS THAN 40%, MAINTAIN CONDUCTOR AMPERE CAPACITY AS REQUIRED BY THE ELECTRICAL <br />CODE (TO INCLUDE ENLARGED CONDUCTORS DUE TO TEMPERATURE AND QUANTITY <br />DERATING VALUES) AND TO PREVENT EXCESSIVE VOLTAGE DROP AND PULLING TENSION DUE <br />TO LONG CONDUIT/CONDUCTOR LENGTHS. <br />D. MINIMUM CONDUIT SIZE (UNLESS NOTED OTHERWISE): <br />1. ABOVE GRADE: 3/4 INCH. (THE USE OF 1/2 INCH WOULD BE ALLOWED FOR INSTALLATION <br />CONDUIT TO INDIVIDUAL FIXTURE WHIPS FROM JUNCTION BOX.) <br />2. TELECOMMUNICATION CONDUIT: 1 INCH. <br />3. CONTROLS CONDUIT: 3/4 INCH. <br />4. MAXIMUM SIZE 1-1/4 INCH FOR CONDUITS CROSSING EACH OTHER. <br />E.CONDUIT SIZES SHALL CHANGE ONLY AT THE ENTRANCE OR EXIT TO A JUNCTION BOX, UNLESS <br /> SPECIFICALLY NOTED ON THE DRAWINGS. <br />3.2 CONDUIT ARRANGEMENT <br />A. IN GENERAL, CONDUIT SHALL BE INSTALLED CONCEALED IN WALLS, IN FINISHED SPACES AND <br />WHERE POSSIBLE OR PRACTICAL, OR AS NOTED OTHERWISE. CONDUIT SHALL BE INSTALLED <br />PARALLEL OR PERPENDICULAR TO WALLS, CEILINGS, AND EXPOSED STRUCTURAL MEMBERS. <br />IN UNFINISHED SPACES, MECHANICAL AND UTILITY AREAS, CONDUIT MAY RUN EITHER <br />CONCEALED OR EXPOSED AS CONDITIONS DICTATE AND AS PRACTICAL UNLESS NOTED <br />OTHERWISE ON DRAWINGS. INSTALLATION SHALL MAINTAIN HEADROOM IN EXPOSED VICINITIES <br />OF PEDESTRIAN OR VEHICULAR TRAFFIC. <br />B. CONDUIT RUNS SHALL BE ROUTED AS SHOWN ON LARGE SCALE DRAWINGS. CONDUIT <br />ROUTING ON DRAWINGS SCALED 1/4"=1'-0" OR LESS SHALL BE CONSIDERED DIAGRAMMATIC, <br />UNLESS NOTED OTHERWISE. THE CORRECT ROUTING, WHEN SHOWN DIAGRAMMATICALLY <br />SHALL BE CHOSEN BY THE CONTRACTOR BASED ON INFORMATION IN THE CONTRACT <br />DOCUMENTS, IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS, APPLICABLE <br />CODES, THE NECA'S "STANDARD OF INSTALLATION", IN ACCORDANCE WITH RECOGNIZED <br />INDUSTRY STANDARDS, AND COORDINATED WITH OTHER CONTRACTORS. <br />C. CONTRACTOR SHALL ADAPT CONTRACTOR'S WORK TO THE JOB CONDITIONS AND MAKE SUCH <br />CHANGES AS REQUIRED AND PERMITTED BY THE ARCHITECT/ENGINEER, SUCH AS MOVING TO <br />CLEAR BEAMS AND JOISTS, ADJUSTING AT COLUMNS, AVOIDING INTERFERENCE WITH <br />WINDOWS, ETC., TO PERMIT THE PROPER INSTALLATION OF OTHER MECHANICAL AND/OR <br />ELECTRICAL EQUIPMENT. <br />D. CONTRACTOR SHALL COOPERATE WITH ALL CONTRACTORS ON THE PROJECT. CONTRACTOR <br />SHALL OBTAIN DETAILS OF OTHER CONTRACTOR'S WORK TO ENSURE FIT AND AVOID <br />CONFLICT. ANY EXPENSE DUE TO THE FAILURE OF THIS CONTRACTOR TO DO SO SHALL BE PAID <br />FOR IN FULL BY CONTRACTOR. THE OTHER TRADES INVOLVED AS DIRECTED BY THE <br />ARCHITECT/ENGINEER SHALL PERFORM THE REPAIR OF WORK DAMAGED AS A RESULT OF <br />NEGLECT OR ERROR BY THIS CONTRACTOR. THE RESULTANT COSTS SHALL BE BORNE BY THIS <br />CONTRACTOR. <br />3.3 CONDUIT SUPPORT <br />A. CONDUIT RUNS INSTALLED ABOVE A SUSPENDED CEILING SHALL BE PROPERLY SUPPORTED. IN <br />NO CASE SHALL CONDUIT REST ON THE SUSPENDED CEILING CONSTRUCTION, NOR UTILIZE <br />CEILING SUPPORT SYSTEM FOR CONDUIT SUPPORT. <br />• SECTION 26 05 33 -CONDUIT AND BOXES <br />• SECTION 26 05 53 -ELECTRICAL IDENTIFICATION <br />B. CONDUIT SHALL NOT BE SUPPORTED FROM DUCTWORK, WATER, SPRINKLER PIPING, OR <br />OTHER NON-STRUCTURAL MEMBERS, UNLESS APPROVED BY THE ARCHITECT/ENGINEER. ALL <br />SUPPORTS SHALL BE FROM STRUCTURAL SLABS, WALLS, STRUCTURAL MEMBERS, AND BAR <br />JOISTS, AND COORDINATED WITH ALL OTHER APPLICABLE CONTRACTORS, UNLESS NOTED <br />OTHERWISE. <br />C. CONDUIT SHALL BE HELD IN PLACE BY THE CORRECT SIZE OF GALVANIZED ONE-HOLE CONDUIT <br />CLAMPS, TWO-HOLE CONDUIT STRAPS, PATENTED SUPPORT DEVICES, CLAMP BACK CONDUIT <br />HANGERS, OR BY OTHER MEANS IF CALLED FOR ON THE DRAWINGS. <br />D. SUPPORT INDIVIDUAL HORIZONTAL RACEWAYS WITH SEPARATE, MALLEABLE-IRON PIPE <br />HANGERS OR CLAMPS. <br />E. SPRING-STEEL CONDUIT CLIPS SPECIFICALLY DESIGNED FOR SUPPORTING SINGLE CONDUITS <br />OR TUBING MAY BE USED IN LIEU OF MALLEABLE-IRON HANGERS FOR 1" AND SMALLER <br />RACEWAYS SERVING LIGHTING AND RECEPTACLE BRANCH CIRCUITS ABOVE ACCESSIBLE <br />CEILINGS AND FOR SECURING RACEWAYS TO SLOTTED CHANNEL AND ANGLE SUPPORTS. <br />F. GROUP CONDUITS IN PARALLEL RUNS WHERE PRACTICAL AND USE CONDUIT RACKS OR <br />TRAPEZE HANGERS CONSTRUCTED OF STEEL CHANNEL, SUSPENDED WITH THREADED SOLID <br />RODS OR WALL MOUNTED FROM METAL CHANNELS WITH CONDUIT STRAPS OR CLAMPS. <br />PROVIDE SPACE IN EACH RACK OR TRAPEZE FOR 25% ADDITIONAL CONDUITS. <br />G. DO NOT EXCEED 25 LBS. PER HANGER AND A MINIMUM SPACING OF 2'-0" ON CENTER WHEN <br />ATTACHING TO METAL ROOF DECKING (EXCLUDES CONCRETE ON METAL DECK). THIS 25 LBS. <br />LOAD AND 2'-0" SPACING INCLUDE ADJACENT ELECTRICAL AND MECHANICAL ITEMS HANGING <br />FROM DECK. IF THE HANGER RESTRICTIONS CANNOT BE ACHIEVED, SUPPLEMENTAL FRAMING <br />OFF STEEL FRAMING WILL NEED TO BE ADDED. <br />H. ARRANGE SUPPORTS IN VERTICAL RUNS SO THE WEIGHT OF RACEWAYS AND ENCLOSED <br />CONDUCTORS IS CARRIED ENTIRELY BY RACEWAY SUPPORTS, WITH NO WEIGHT LOAD ON <br />RACEWAY TERMINALS. <br />I. SUPPORTS FOR METALLIC CONDUIT SHALL BE NO GREATER THAN 10 FEET. A SMALLER <br />INTERVAL MAY BE USED IF NECESSITATED BY BUILDING CONSTRUCTION, BUT IN NO EVENT <br />SHALL SUPPORT SPANS EXCEED THE ELECTRICAL CODE REQUIREMENTS. CONDUIT SHALL BE <br />SECURELY FASTENED WITHIN 3 FEET OF EACH OUTLET BOX, JUNCTION BOX, DEVICE BOX, <br />CABINET, OR FITTING. <br />J. SUPPORTS OF FLEXIBLE CONDUIT SHALL BE WITHIN 12 INCHES OF EACH OUTLET BOX, <br />JUNCTION BOX, DEVICE BOX, CABINET, OR FITTING AND AT INTERVALS NOT TO EXCEED 4.5 <br />FEET. <br />K. FINISH: <br />1. PRIME COAT EXPOSED STEEL HANGERS AND SUPPORTS. HANGERS AND SUPPORTS IN <br />CRAWL SPACES, PIPE SHAFTS, AND ABOVE SUSPENDED CEILING SPACES ARE NOT <br />CONSIDERED EXPOSED. <br />2. TRIM ALL ENDS OF EXPOSED FIELD FABRICATED STEEL HANGERS, SLOTTED CHANNEL AND <br />THREADED ROD TO WITHIN 1" OF SUPPORT OR FASTENER TO ELIMINATE POTENTIAL INJURY <br />TO PERSONNEL UNLESS SHOWN OTHERWISE ON THE DRAWINGS. SMOOTH ENDS AND <br />INSTALL ELASTOMERIC INSULATION WITH TWO COATS OF LATEX PAINT IF EXPOSED STEEL <br />IS WITHIN 6'-6" OF FINISH FLOOR AND PRESENTS POTENTIAL INJURY TO PERSONNEL. <br />3.4 CONDUIT INSTALLATION <br />A. CONDUIT CONNECTIONS: <br />1. SHORTER THAN STANDARD CONDUIT LENGTHS SHALL BE CUT SQUARE USING INDUSTRY <br />STANDARDS. THE ENDS OF ALL CONDUITS CUT SHALL BE REAMED OR OTHERWISE <br />FINISHED TO REMOVE ALL ROUGH EDGES. <br />2. METALLIC CONDUIT CONNECTIONS IN SLAB ON GRADE INSTALLATION SHALL BE SEALED <br />AND ONE COAT OF RUST INHIBITOR PRIMER APPLIED AFTER THE CONNECTION IS MADE. <br />3. WHERE CONDUITS WITH TAPERED THREADS CANNOT BE COUPLED WITH STANDARD <br />COUPLINGS, THEN APPROVED SPLIT OR ERICKSON COUPLINGS SHALL BE USED. RUNNING <br />THREADS WILL NOT BE PERMITTED. <br />4. INSTALL EXPANSION/DEFLECTION JOINTS WHERE CONDUIT CROSSES STRUCTURE <br />EXPANSION/SEISMIC JOINTS. <br />B.CONDUIT TERMINATIONS FOR ALL LOW VOLTAGE WIRING SHALL HAVE NYLON BUSHINGS <br /> INSTALLED ON EACH END OF EVERY CONDUIT RUN. <br />C.CONDUIT BENDS: <br />1. USE A HYDRAULIC ONE-SHOT CONDUIT BENDER OR FACTORY ELBOWS FOR BENDS IN <br />CONDUIT 2" IN SIZE OR LARGER. ALL STEEL CONDUIT BENDING SHALL BE DONE COLD; NO <br />HEATING OF STEEL CONDUIT SHALL BE PERMITTED. <br />2. A RUN OF CONDUIT SHALL NOT CONTAIN MORE THAN THE EQUIVALENT OF FOUR (4) <br />QUARTER BENDS (360°), INCLUDING THOSE BENDS LOCATED IMMEDIATELY AT THE OUTLET <br />OR BODY. <br />3. TELECOMMUNICATIONS CONDUITS SHALL HAVE NO MORE THAN TWO (2) 90-DEGREE BENDS <br />BETWEEN PULL POINTS AND CONTAIN NO CONTINUOUS SECTIONS LONGER THAN 100 FEET. <br />INSERT PULL POINTS OR PULL BOXES FOR CONDUITS EXCEEDING 100 FEET IN LENGTH. <br />a. A THIRD BEND IS ACCEPTABLE IF: <br />1. THE TOTAL RUN IS NOT LONGER THAN (33) FEET. <br />2. THE CONDUIT SIZE IS INCREASED TO THE NEXT TRADE SIZE. <br />4.TELECOMMUNICATIONS PULL BOXES SHALL NOT BE USED IN LIEU OF A BEND. ALIGN <br /> CONDUITS THAT ENTER THE PULL BOX FROM OPPOSITE ENDS WITH EACH OTHER. PULL <br /> BOX SIZE SHALL BE TWELVE (12) TIMES THE DIAMETER OF THE LARGEST CONDUIT. SLIP <br /> SLEEVES OR GUTTERS CAN BE USED IN PLACE OF A PULL BOX. <br />5.TELECOMMUNICATIONS CONDUIT(S): MAINTAIN APPROPRIATE CONDUIT BEND RADIUS AT <br /> ALL TIMES. FOR CONDUITS WITH AN INTERNAL DIAMETER OF LESS THAN 2", MAINTAIN A <br /> BEND RADIUS OF AT LEAST 6 TIMES THE INTERNAL DIAMETER. FOR CONDUITS WITH AN <br /> INTERNAL DIAMETER 2" OR GREATER, MAINTAIN A BEND RADIUS OF AT LEAST 10 TIMES THE <br /> INTERNAL DIAMETER. <br />6.USE CONDUIT BODIES TO MAKE SHARP CHANGES IN DIRECTION (I.E. AROUND BEAMS). <br />D.CONDUIT PLACEMENT: <br />1. CONDUIT SHALL BE MECHANICALLY CONTINUOUS FROM SOURCE OF CURRENT TO ALL <br />OUTLETS. CONDUIT SHALL BE ELECTRICALLY CONTINUOUS FROM SOURCE OF CURRENT TO <br />ALL OUTLETS, UNLESS A PROPERLY SIZED GROUNDING CONDUCTOR IS ROUTED WITHIN <br />THE CONDUIT. ALL METALLIC CONDUITS SHALL BE BONDED PER THE ELECTRICAL CODE. <br />2. ROUTE EXPOSED CONDUIT AND CONDUIT ABOVE SUSPENDED CEILINGS (ACCESSIBLE OR <br />NOT) PARALLEL/PERPENDICULAR TO THE BUILDING STRUCTURAL LINES, AND AS CLOSE TO <br />BUILDING STRUCTURE AS POSSIBLE. WHEREVER POSSIBLE, ROUTE HORIZONTAL CONDUIT <br />RUNS ABOVE WATER AND STEAM PIPING. <br />3. AVOID MOISTURE TRAPS WHERE POSSIBLE. WHERE UNAVOIDABLE, PROVIDE A JUNCTION <br />BOX WITH DRAIN FITTING AT CONDUIT LOW POINT. <br />4. ALL CONDUITS THROUGH WALLS SHALL BE GROUTED OR SEALED INTO OPENINGS. WHERE <br />CONDUIT PENETRATES FIREWALLS AND FLOORS, SEAL WITH A UL LISTED SEALANT. ; REFER <br />TO SECTION 26 05 03 FOR THROUGH PENETRATION FIRESTOPPING REQUIREMENTS. <br />5. CONTRACTOR SHALL PROVIDE SUITABLE MECHANICAL PROTECTION AROUND ALL <br />CONDUITS STUBBED OUT FROM FLOORS, WALLS OR CEILINGS DURING CONSTRUCTION TO <br />PREVENT BENDING OR DAMAGING OF STUBS DUE TO CARELESSNESS WITH <br />CONSTRUCTION EQUIPMENT. <br />6. CONTRACTOR SHALL PROVIDE A POLYPROPYLENE PULL CORD WITH 2000 LBS. TENSILE <br />STRENGTH IN EACH EMPTY CONDUIT (INDOOR AND OUTDOOR), EXCEPT IN SLEEVES AND <br />NIPPLES. <br />3.5 CONDUIT TERMINATIONS <br />A. WHERE CONDUIT BONDING IS INDICATED OR REQUIRED IN THE CONTRACT DOCUMENTS, THE <br />BUSHINGS SHALL BE A GROUNDING TYPE SIZED FOR THE CONDUIT AND GROUND BONDING <br />CONDUCTOR AS MANUFACTURED BY O-Z/GEDNEY, APPLETON, THOMAS & BETTS, BURNDY, <br />REGAL, ORBIT INDUSTRIES OR APPROVED EQUAL. <br />B. CONDUITS WITH TERMINATION FITTINGS SHALL BE THREADED FOR ONE (1) LOCK NUT ON THE <br />OUTSIDE AND ONE (1) LOCK NUT AND BUSHING ON THE INSIDE OF EACH BOX. <br />C. WHERE CONDUITS TERMINATE IN BOXES WITH KNOCKOUTS, THEY SHALL BE SECURED TO THE <br />BOXES WITH LOCK NUTS AND PROVIDED WITH APPROVED SCREW TYPE TINNED IRON <br />BUSHINGS OR FITTINGS WITH PLASTIC INSERTS. <br />D. WHERE CONDUITS TERMINATE IN BOXES, FITTINGS, OR BODIES WITH THREADED OPENINGS, <br />THEY SHALL BE TIGHTLY SCREWED AGAINST THE SHOULDER PORTION OF THE THREADED <br />OPENINGS. <br />E. CONDUIT TERMINATIONS TO ALL MOTORS SHALL BE MADE WITH FLEXIBLE METALLIC CONDUIT <br />(FMC), UNLESS NOTED OTHERWISE. FINAL CONNECTIONS TO ROOF EXHAUST FANS, OR OTHER <br />EXTERIOR MOTORS AND MOTORS IN DAMP OR WET LOCATIONS SHALL BE MADE WITH <br />LIQUIDTIGHT FLEXIBLE METALLIC CONDUIT (LFMC). MOTORS IN HAZARDOUS AREAS, AS <br />DEFINED IN THE ELECTRICAL CODE, SHALL BE CONNECTED USING FLEXIBLE CONDUIT RATED <br />FOR THE ENVIRONMENT. FLEXIBLE CONDUIT SHALL NOT EXCEED 6' IN LENGTH. ROUTE <br />EQUIPMENT GROUND CONDUCTORS FROM CIRCUIT GROUND TO MOTOR GROUND TERMINAL <br />THROUGH FLEXIBLE CONDUIT. <br />F. ALL CONDUIT ENDS SHALL BE SEALED WITH PLASTIC IMMEDIATELY AFTER INSTALLATION TO <br />PREVENT THE ENTRANCE OF ANY FOREIGN MATTER DURING CONSTRUCTION. THE SEALS <br />SHALL BE REMOVED AND THE CONDUITS BLOWN CLEAR OF ALL FOREIGN MATTER PRIOR TO <br />ANY WIRES OR PULL CORDS BEING INSTALLED. <br />1. APPROVED EQUAL <br />3.6 BOX INSTALLATION SCHEDULE <br />A. GALVANIZED STEEL BOXES MAY BE USED IN: <br />1. CONCEALED INTERIOR LOCATIONS ABOVE CEILINGS AND IN HOLLOW STUDDED PARTITIONS. <br />2. EXPOSED INTERIOR LOCATIONS IN MECHANICAL ROOMS AND IN ROOMS WITHOUT <br />CEILINGS; HIGHER THAN 8' ABOVE THE HIGHEST PLATFORM LEVEL. <br />B.CAST BOXES SHALL BE USED IN: <br />1. EXPOSED INTERIOR LOCATIONS WITHIN 8' OF THE HIGHEST PLATFORM LEVEL. <br />2. WET LOCATIONS. <br />3.7 COORDINATION OF BOX LOCATIONS <br />A. PROVIDE ELECTRICAL BOXES AS SHOWN ON THE DRAWINGS, AND AS REQUIRED FOR SPLICES, <br />TAPS, WIRE PULLING, EQUIPMENT CONNECTIONS, AND CODE COMPLIANCE. <br />B. ELECTRICAL BOX LOCATIONS SHOWN ON THE CONTRACT DRAWINGS ARE APPROXIMATE, <br />UNLESS DIMENSIONED. VERIFY LOCATION OF FLOOR BOXES AND OUTLETS IN OFFICES AND <br />WORK AREAS PRIOR TO ROUGH-IN. <br />C. LOCATE AND INSTALL BOXES TO ALLOW ACCESS. AVOID INTERFERENCES WITH DUCTWORK, <br />PIPING, STRUCTURE, EQUIPMENT, ETC. RECESSED LUMINAIRES SHALL NOT BE USED AS <br />ACCESS TO OUTLET, PULL, AND JUNCTION BOXES. WHERE INSTALLATION IS INACCESSIBLE, <br />PROVIDE ACCESS DOORS. COORDINATE LOCATIONS AND SIZES OF REQUIRED ACCESS DOORS <br />WITH THE ARCHITECT/ENGINEER AND GENERAL CONTRACTOR. <br />D. LOCATE AND INSTALL TO MAINTAIN HEADROOM AND TO PRESENT A NEAT APPEARANCE. <br />3.8 OUTLET BOX INSTALLATION <br />A. DO NOT INSTALL BOXES BACK-TO-BACK IN WALLS. <br />1. PROVIDE A MINIMUM HORIZONTAL SEPARATION OF 6 INCHES BETWEEN BOXES INSTALLED <br />ON OPPOSITE SIDES OF NON-RATED STUD WALLS. <br />2. PROVIDE A MINIMUM HORIZONTAL SEPARATION OF 24 INCHES BETWEEN BOXES INSTALLED <br />ON OPPOSITE SIDES OF FIRE-RATED WALLS. WHEN THE MINIMUM SEPARATION CANNOT BE <br />MAINTAINED, THE BOX IS GREATER THAN 16 SQUARE INCHES OR THE TOTAL BOX AREA (ALL <br />TRADES) PER 100 SQUARE FEET IS GREATER THAN OR EQUAL TO 100 SQUARE INCHES, <br />INSTALL FIRE-RATED MOLDABLE PADS TO ALL FIVE SIDES OF THE BACK BOX TO MAINTAIN <br />THE FIRE RATING OF THE WALL. INSTALL MOLDABLE PADS IN ACCORDANCE WITH UL <br />LISTING FOR THE SPECIFIC PRODUCT. SOUND INSULATION PADS ARE NOT ACCEPTABLE <br />FOR USE IN FIRE-RATED WALL APPLICATIONS UNLESS THE PRODUCT CARRIES THE <br />NECESSARY FIRE RATING. <br />B.THE CONTRACTOR SHALL ANCHOR SWITCH AND OUTLET BOX TO WALL CONSTRUCTION SO <br /> THAT IT IS FLUSH WITH THE FINISHED MASONRY, PANELING, DRYWALL, PLASTER, ETC. THE <br /> CONTRACTOR SHALL CHECK THE BOXES AS THE FINISH WALL SURFACE IS BEING INSTALLED TO <br /> ASSURE THAT THE BOX IS FLUSH. (PROVIDE PLASTER RINGS AS NECESSARY.) <br />C.MOUNT AT HEIGHTS SHOWN OR NOTED ON THE DRAWINGS. <br />D.PROVIDE KNOCKOUT CLOSURES FOR UNUSED OPENINGS. <br />E.SUPPORT BOXES INDEPENDENTLY OF CONDUIT. <br />F.USE MULTIPLE-GANG BOXES WHERE MORE THAN ONE DEVICE IS MOUNTED TOGETHER; DO <br /> NOT USE SECTIONAL BOXES. PROVIDE BARRIERS TO SEPARATE WIRING OF DIFFERENT <br /> VOLTAGE SYSTEMS. <br />G.INSTALL BOXES IN WALLS WITHOUT DAMAGING WALL INSULATION. <br />H.COORDINATE MOUNTING HEIGHTS AND LOCATIONS OF OUTLETS MOUNTED ABOVE COUNTERS, <br /> BENCHES, AND BACKSPLASHES. <br />I.POSITION OUTLETS TO LOCATE LUMINAIRES AS SHOWN ON REFLECTED CEILING DRAWINGS. <br />J.PROVIDE RECESSED OUTLET BOXES IN FINISHED AREAS; SECURE BOXES TO INTERIOR WALL <br /> AND PARTITION STUDS, ACCURATELY POSITIONED TO ALLOW FOR SURFACE FINISH <br /> THICKNESS. USE STAMPED STEEL STUD BRIDGES FOR FLUSH OUTLETS IN HOLLOW STUD WALL, <br /> AND ADJUSTABLE STEEL CHANNEL FASTENERS FOR FLUSH CEILING OUTLET BOXES. <br />K.ALIGN WALL-MOUNTED OUTLET BOXES FOR SWITCHES, THERMOSTATS, AND SIMILAR DEVICES. <br />3.9 PULL AND JUNCTION BOX INSTALLATION <br />A. LOCATE PULL BOXES AND JUNCTION BOXES ABOVE ACCESSIBLE CEILINGS OR IN UNFINISHED <br />AREAS. <br />B. SUPPORT PULL AND JUNCTION BOXES INDEPENDENT OF CONDUIT. <br />C. DO NOT INSTALL BOXES BACK-TO-BACK IN WALLS. <br />1. PROVIDE A MINIMUM HORIZONTAL SEPARATION OF 6 INCHES BETWEEN BOXES INSTALLED <br />ON OPPOSITE SIDES OF NON-RATED STUD WALLS. <br />2. PROVIDE A MINIMUM HORIZONTAL SEPARATION OF 24 INCHES BETWEEN BOXES INSTALLED <br />ON OPPOSITE SIDES OF FIRE-RATED WALLS. WHEN THE MINIMUM SEPARATION CANNOT BE <br />MAINTAINED, THE BOX IS GREATER THAN 16 SQUARE INCHES OR THE TOTAL BOX AREA (ALL <br />TRADES) PER 100 SQUARE FEET IS GREATER THAN OR EQUAL TO 100 SQUARE INCHES, <br />INSTALL FIRE-RATED MOLDABLE PADS TO ALL FIVE SIDES OF THE BACK BOX TO MAINTAIN <br />THE FIRE RATING OF THE WALL. INSTALL MOLDABLE PADS IN ACCORDANCE WITH UL <br />LISTING FOR THE SPECIFIC PRODUCT. SOUND INSULATION PADS ARE NOT ACCEPTABLE <br />FOR USE IN FIRE-RATED WALL APPLICATIONS UNLESS THE PRODUCT CARRIES THE <br />NECESSARY FIRE RATING. <br />END OF SECTION <br />SECTION 26 05 53 -ELECTRICAL IDENTIFICATION <br />PART 1 -GENERAL <br />1.1 SECTION INCLUDES <br />A. ADHESIVE MARKINGS AND FIELD LABELS <br />B. NAMEPLATES AND SIGNS <br />C. PRODUCT COLORS <br />1.2 REFERENCES <br />A. NFPA 70E -NATIONAL ELECTRICAL SAFETY CODE <br />B. CEC CALIFORNIA ELECTRICAL CODE <br />PART 2 -PRODUCTS <br />2.1 ADHESIVE MARKINGS AND FIELD LABELS <br />A. COLORED ADHESIVE MARKING TAPE FOR BANDING RACEWAYS, WIRES, AND CABLES: SELF- <br />ADHESIVE VINYL TAPE NOT LESS THAN 3 MILS THICK BY 1 INCH TO 2 INCHES IN WIDTH. <br />B. PRETENSIONED FLEXIBLE WRAPAROUND COLORED PLASTIC SLEEVES FOR CABLE <br />IDENTIFICATION: FLEXIBLE ACRYLIC BANDS SIZED TO SUIT THE CABLE DIAMETER AND <br />ARRANGED TO STAY IN PLACE BY PRE-TENSIONED GRIPPING ACTION WHEN COILED AROUND <br />THE CABLE. <br />C. WIRE/CABLE DESIGNATION TAPE MARKERS: VINYL OR VINYL-CLOTH, SELF-ADHESIVE, <br />WRAPAROUND, CABLE/CONDUCTOR MARKERS WITH PREPRINTED NUMBERS AND LETTER. <br />D. CABLE TIES: FUNGUS-INERT, SELF-EXTINGUISHING, ONE-PIECE, SELF-LOCKING NYLON CABLE <br />TIES, 0.18-INCH MINIMUM WIDTH, 50-LB MINIMUM TENSILE STRENGTH, AND SUITABLE FOR A <br />TEMPERATURE RANGE FROM -40°F TO 185°F (-40°C TO 85°C), TYPE 2/2S OR TYPE 21/21S BASED <br />ON APPLICATION. PROVIDE TIES IN SPECIFIED COLORS WHEN USED FOR COLOR CODING. <br />CABLE TIES SHALL BE LISTED AND IDENTIFIED FOR THE APPLICATION, SECUREMENT, AND <br />SUPPORT. <br />2.2 NAMEPLATES AND SIGNS <br />A. ENGRAVED, PLASTIC-LAMINATED LABELS, SIGNS AND INSTRUCTION PLATES: ENGRAVING <br />STOCK MELAMINE PLASTIC LAMINATE, 1/16-INCH MINIMUM THICK FOR SIGNS UP TO 20 SQUARE <br />INCHES, OR 8 INCHES IN LENGTH; 1/8 INCH THICK FOR LARGER SIZES. LABELS SHALL BE <br />PUNCHED FOR MECHANICAL FASTENERS. <br />2.3 PRODUCT COLORS <br />1. NORMAL POWER AND GENERAL LABELS: BLACK LETTERS ON WHITE FACE <br />2. EMERGENCY: RED LETTERS ON WHITE FACE <br />B.NAMEPLATES AND SIGNS: <br />1. NORMAL POWER: BLACK LETTERS ON WHITE FACE <br />2. EMERGENCY: WHITE LETTERS ON RED FACE <br />3. PROVIDE COLOR CODED CONDUIT AS INDICATED BELOW. CONDUIT SHALL BE COLORED BY <br />THE MANUFACTURER: <br />a. NORMAL POWER AND GENERAL DISTRIBUTION: SILVER <br />b. EMERGENCY POWER DISTRIBUTION SYSTEM: RED <br />PART 3 -EXECUTION <br />3.1 INSTALLATION <br />A. LETTERING AND GRAPHICS: COORDINATE NAMES, ABBREVIATIONS, COLORS, AND OTHER <br />DESIGNATIONS USED IN ELECTRICAL IDENTIFICATION WORK WITH CORRESPONDING <br />DESIGNATIONS SPECIFIED OR INDICATED. INSTALL NUMBERS, LETTERING, AND COLORS AS <br />INDICATED ON DRAWINGS OR AS REQUIRED BY CODE. <br />B. INSTALL IDENTIFICATION DEVICES IN ACCORDANCE WITH MANUFACTURER'S WRITTEN <br />INSTRUCTION AND REQUIREMENTS OF ELECTRICAL CODE. <br />C. SEQUENCE OF WORK: WHERE IDENTIFICATION IS TO BE APPLIED TO SURFACES THAT REQUIRE <br />FINISH, INSTALL IDENTIFICATION AFTER COMPLETION OF FINISH WORK. ALL MOUNTING <br />SURFACES SHALL BE CLEANED AND DEGREASED PRIOR TO IDENTIFICATION INSTALLATION. <br />D. CIRCUIT IDENTIFICATION: TAG OR LABEL CONDUCTORS AS FOLLOWS: <br />1. MULTIPLE POWER OR LIGHTING CIRCUITS IN SAME ENCLOSURE: WHERE MULTIPLE BRANCH <br />CIRCUITS ARE TERMINATED OR SPLICED IN A BOX OR ENCLOSURE, LABEL EACH <br />CONDUCTOR WITH SOURCE AND CIRCUIT NUMBER. <br />2. MULTIPLE CONTROL WIRING AND COMMUNICATION/SIGNAL CIRCUITS IN SAME ENCLOSURE: <br />FOR CONTROL AND COMMUNICATIONS/SIGNAL WIRING, USE W IRE/CABLE MARKING TAPE AT <br />TERMINATIONS IN WIRING BOXES, TROUGHS, AND CONTROL CABINETS. USE CONSISTENT <br />LETTER/NUMBER CONDUCTOR DESIGNATIONS THROUGHOUT ON WIRE/CABLE MARKING <br />TAPE. <br />3. MATCH IDENTIFICATION MARKINGS WITH DESIGNATIONS USED IN PANELBOARDS SHOP <br />DRAWINGS, CONTRACT DOCUMENTS, AND SIMILAR PREVIOUSLY ESTABLISHED <br />IDENTIFICATION SCHEMES FOR THE FACILITY'S ELECTRICAL INSTALLATIONS. <br />4. EMERGENCY OPERATING SIGNS: INSTALL, WHERE REQUIRED BY ELECTRICAL CODE, <br />WHERE INDICATED, OR WHERE REASONABLY REQUIRED TO ASSURE SAFE OPERATION AND <br />MAINTENANCE OF ELECTRICAL SYSTEMS AND OF THE ITEMS TO WHICH THEY CONNECT, <br />ENGRAVED LAMINATE SIGNS WITH WHITE LEGEND ON RED BACKGROUND WITH MINIMUM <br />3/8-INCH HIGH LETTERING FOR EMERGENCY INSTRUCTIONS ON EMERGENCY POWER OFF, <br />POWER TRANSFER, OR OTHER EMERGENCY OPERATIONS. <br />E.APPLY CIRCUIT/CONTROL/ITEM DESIGNATION LABELS OF ENGRAVED PLASTIC LAMINATE FOR <br /> PUSHBUTTONS, PILOT LIGHTS, ALARM/SIGNAL COMPONENTS, AND SIMILAR ITEMS, EXCEPT <br /> WHERE LABELING IS SPECIFIED ELSEWHERE. <br />F.INSTALL LABELS PARALLEL TO EQUIPMENT LINES AT LOCATIONS AS REQUIRED AND AT <br /> LOCATIONS FOR BEST CONVENIENCE OF VIEWING WITHOUT INTERFERENCE WITH OPERATION <br /> AND MAINTENANCE OF EQUIPMENT. <br />G.SELECTIVE COORDINATION LABEL: INSTALL CAUTION SIGNS ON ALL SWITCHBOARDS, <br /> DISTRIBUTION PANELS, PANELBOARDS, DISCONNECTS, AND OTHER EQUIPMENT WITH <br /> SELECTIVELY COORDINATED OVERCURRENT PROTECTION DEVICES. SIGN AT A MINIMUM SHALL <br /> CONTAIN: <br />1. CAUTION: OVERCURRENT DEVICES IN THIS ENCLOSURE ARE SELECTIVELY COORDINATED. <br />EQUIVALENT REPLACEMENTS AND TRIP SETTINGS ARE REQUIRED. <br />3.2 LIGHTING CONTROL AND RECEPTACLE COVER PLATES <br />A. PRODUCT: <br />1. ADHESIVE LABELS AND FIELD MARKINGS <br />B.IDENTIFICATION MATERIAL TO BE ENGRAVED PLASTIC-LAMINATED LABELS, 1/16-INCH MINIMUM <br /> THICKNESS WITH WHITE LETTERS ON A RED FACE. LETTER AND NUMBER SIZE TO 1/8-INCH <br /> HIGH. <br />C.PROVIDE IDENTIFICATION ON ALL SWITCH AND RECEPTACLE COVER PLATES. IDENTIFICATION <br /> SHALL INDICATE SOURCE AND CIRCUIT NUMBER SERVING THE DEVICE (E.G. "C1A #24"). <br />3.3 CONDUIT AND EXPOSED CABLE LABELING <br />A. PRODUCT: <br />1. ADHESIVE LABELS AND FIELD MARKINGS <br />B.CONDUIT IDENTIFICATION: PRE-PRINTED, FLEXIBLE, SELF-ADHESIVE VINYL LABELS WITH <br /> LEGEND AT 20 FOOT (6 METER) INTERVALS TO IDENTIFY ALL CONDUITS RUN EXPOSED OR <br /> LOCATED ABOVE ACCESSIBLE CEILINGS. CONDUITS LOCATED ABOVE NON-ACCESSIBLE <br /> CEILING OR IN FLOORS AND WALLS SHALL BE LABELED WITHIN 3 FEET OF BECOMING <br /> ACCESSIBLE, OR SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, AND FLOORS. <br /> LABELS FOR MULTIPLE CONDUITS SHALL BE ALIGNED. REFER TO COLOR REQUIREMENTS IN <br /> PART 2 WHEN APPLICABLE IN ADDITION TO THE FOLLOWING: <br />1. 1000 VOLT OR LESS NORMAL/EMERGENCY POWER: INDICATE FEEDER IDENTIFICATION AND <br />VOLTAGE. <br />2. ESSENTIAL ELECTRICAL SYSTEM EES: WHEN APPLICABLE THE LABEL SHALL INCLUDE <br />"ESSENTIAL ELECTRICAL SYSTEM EES". MAXIMUM INTERVAL BETWEEN LABEL INTERVALS <br />SHALL BE 25 FEET OR AS REQUIRED BY CODE. <br />3.4 BOX LABELING <br />A. PRODUCTS: <br />1. ADHESIVE LABELS AND FIELD MARKINGS <br />B.IDENTIFY JUNCTION, PULL AND CONNECTION BOXES: LABELING SHALL BE 3/8-INCH KROY TAPE <br /> OR BROTHER SELF-LAMINATING VINYL LABEL, LETTERS/NUMBERS COLOR CODED SAME AS <br /> CONDUITS. IN ROOMS THAT ARE PAINTED OUT, PROVIDE LABELING ON INSIDE OF COVER. <br />C.ALL JUNCTION, PULL, AND CONNECTION BOXES SHALL BE IDENTIFIED AS FOLLOWS: <br />1. FOR POWER AND LIGHTING CIRCUITS, INDICATE SYSTEM VOLTAGE AND IDENTITY OF <br />CONTAINED CIRCUITS ("120V, 1LA1-3,5,7"). <br />2. ESSENTIAL ELECTRICAL SYSTEM EES: WHEN APPLICABLE THE LABEL SHALL INCLUDE <br />"ESSENTIAL ELECTRICAL SYSTEM EES". MAXIMUM INTERVAL BETWEEN LABEL INTERVALS <br />SHALL BE 25 FEET OR AS REQUIRED BY CODE. <br />3.5 CONDUCTOR COLOR CODING <br />A. PRODUCTS: <br />1. ALL WIRE AND CABLES SHALL BE COLOR CODED BY THE MANUFACTURER. <br />B.COLOR CODING SHALL BE APPLIED AT ALL PANELS, SWITCHES, JUNCTION BOXES, PULL BOXES, <br /> VAULTS, MANHOLES ETC., WHERE THE WIRES AND CABLES ARE VISIBLE AND TERMINATIONS <br /> ARE MADE. THE SAME COLOR CODING SHALL BE USED THROUGHOUT THE ENTIRE ELECTRICAL <br /> SYSTEM, THEREFORE MAINTAINING PROPER PHASING THROUGHOUT THE ENTIRE PROJECT. <br />C.COLORED CABLE TIES SHALL BE APPLIED IN GROUPS OF THREE TIES OF SPECIFIED COLOR TO <br /> EACH CONDUCTOR AT EACH TERMINAL OR SPLICE POINT STARTING 3 INCHES FROM THE <br /> TERMINATION AND SPACED AT 3-INCHES CENTERS. TIGHTEN TO A SNUG FIT, AND CUT OFF <br /> EXCESS LENGTH. <br />D.WHERE MORE THAN ONE NOMINAL VOLTAGE SYSTEM EXISTS IN A BUILDING OR FACILITY, EACH <br /> UNGROUNDED CONDUCTOR OF A MULTI-WIRE BRANCH CIRCUIT, WHERE ACCESSIBLE, SHALL <br /> BE IDENTIFIED BY PHASE AND SYSTEM. <br />1. 208Y/120 VOLT, 4-WIRE: <br />a. A-PHASE -BLACK <br />b. B-PHASE -RED <br />c. C-PHASE -BLUE <br />d. NEUTRAL -WHITE <br />e. GROUND BOND -GREEN <br />2.480Y/277 VOLT, 4-WIRE: <br />a. A-PHASE -BROWN <br />b. B-PHASE -ORANGE <br />c. C-PHASE -YELLOW <br />d. NEUTRAL -GRAY <br />e. GROUND BOND -GREEN <br />3.GROUNDING CONDUCTORS: <br />a. EQUIPMENT GROUNDING CONDUCTORS, MAIN/SYSTEM/SUPPLY-SIDE BONDING <br />JUMPERS: GREEN. <br />3.6 CONTROL EQUIPMENT IDENTIFICATION <br />A. PRODUCTS: <br />1. NAMEPLATES AND SIGNS <br />B.PROVIDE IDENTIFICATION ON THE FRONT OF ALL CONTROL EQUIPMENT SUCH AS ENCLOSED <br /> CIRCUIT BREAKERS, COMBINATION STARTERS, STARTERS, VFDS, CONTACTORS, ETC. <br />C.IDENTIFICATION SHALL BE PROVIDED FOR ALL CONNECTIONS TO EQUIPMENT FURNISHED BY <br /> THIS CONTRACTOR, OTHER CONTRACTORS, OR THE OWNER. <br />D.LABELING SHALL INCLUDE: <br />1. EQUIPMENT TYPE AND CONTRACT DOCUMENTS DESIGNATION OF EQUIPMENT BEING <br />SERVED. <br />2. LOCATION OF EQUIPMENT BEING SERVED IF IT IS NOT LOCATED WITHIN SIGHT. <br />3. VOLTAGE AND PHASE OF CIRCUIT(S). <br />4. PANEL AND CIRCUIT NUMBER(S) SERVING THE EQUIPMENT. <br />5. SAMPLE LABEL: <br />EXHAUST FAN EF-1 ("LOCATED ON ROOF") <br />480V, 3-PHASE <br />FED FROM "1HA1-1" <br />3.7 EQUIPMENT CONNECTION IDENTIFICATION <br />A. PRODUCTS: <br />1. NAMEPLATES AND SIGNS <br />B.PROVIDE IDENTIFICATION FOR HARD WIRED ELECTRICAL CONNECTIONS TO EQUIPMENT SUCH <br /> AS DISCONNECTS SWITCHES, STARTERS, ETC. PLUG AND CORD TYPE CONNECTIONS DO NOT <br /> REQUIRE THIS SPECIFIC LABEL. <br />END OF SECTION <br />TE OLIRFFOAC <br />LANRP <br />E 23191 <br />STA <br />ER <br />REGIST <br />ED <br />INA <br />N <br />REENIGE <br />FO OISSE <br />E AICLCERTL <br />Exp. 06/30/26 <br />MIRASOPHOCLISGEORGY <br />IMEG CORP. RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, <br />TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING <br />AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP. AND SHALL <br />NOT BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE <br />EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF IMEG CORP. <br />©2022 IMEG CORP. <br />REF. SCALE IN INCHES <br />0 1 2 3 <br />The FUTURE. Built Smarter www.imegcorp.com <br />R <br />SHEET TITLE <br />PROJECT <br />FACILITY <br />FAC NO: BLDG NO: FLOOR LEV: SECTION: <br />KP PROJ. NO. <br />PERMIT NO. <br />555 W. 5th St Suite 2950 | Los Angeles, CA 90013 USA <br />Phone 310.820.4600 | Fax 310.207.4215 <br />www.huitt-zollars.com <br />ARCHITECT <br />CONSULTANT <br />ARCHITECT SEAL CONSULTANT SEAL <br />KAISER FOUNDATION <br />HOSPITALS NATIONAL <br />FACILITIES SERVICES 1800 <br />HARRISON STREET OAKLAND, <br />CALIFORNIA 94612 <br />ISSUE / REVISION LOG <br />NO. ISSUED DATE <br />0 <br />5' <br /> <br />5 <br />0 <br />' <br />GR <br />A <br />P <br />H <br />I <br />C <br /> <br />S <br />C <br />A <br />L <br />E <br />S <br />: <br /> <br />1 <br />/ <br />1 <br />6 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />0 <br />25 <br />' <br />1/ <br />8 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />5' <br />0 <br />12 <br />' <br />1/ <br />4 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />1' <br />0 <br />6' <br />1/ <br />2 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />1' <br />0 <br />2' <br />1- <br />1 <br />/ <br />2 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />0 <br />1' <br />3" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />IF <br /> <br />T <br />H <br />I <br />S <br /> <br />S <br />H <br />E <br />E <br />T <br /> <br />I <br />S <br /> <br />N <br />O <br />T <br /> <br />30 <br />" <br />x <br />4 <br />2 <br />" <br />, <br /> <br />I <br />T <br /> <br />I <br />S <br /> <br />A <br /> <br />R <br />E <br />D <br />U <br />C <br />E <br />D <br /> <br />PR <br />I <br />N <br />T <br /> <br />- <br /> <br />S <br />C <br />A <br />L <br />E <br /> <br />AC <br />C <br />O <br />R <br />D <br />I <br />N <br />G <br />L <br />Y <br />AGENCY APPLICATION NUMBER <br />AGENCY APPROVAL STAMP <br />THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS <br />NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. <br />HZ PROJ. NO. <br />222 S. HARBOR BOULEVARD, SUITE 800 I ANAHEIM, CA 92805 <br />PH: 714.490.5555 I FAX: 714.490.5560 <br />IMEG PROJ. NO.: 22008618.00 <br />PROJECT #22008618.00 <br />SOCC 2022 R HBM 1st Fl KPOJ <br />REMODEL <br />E0-04 <br />ELECTRICAL SPECIFICATION <br />CA394-1 <br />CAP0227721R314412.35 <br />HARBOR/MacARTHUR MEDICAL OFF <br />3401 S. HARBOR BLVD. <br />SANTA ANA, CALIFORNIA 92704 <br />CITY SUBMITTAL 11/03/2025 <br />101125520, 20187249, 40140902