Laserfiche WebLink
PROPOSED EGRESS PLAN <br />SCALE: 1/4"=1' <br />EXIT + EMERGENCY LIGHT <br />EMERGENCY LIGHT <br />EGRESS PATH <br />·CBC 2022 - 1017.2 Exit Access Travel Distance, Limitations: <br />Exit access travel distance shall not exceed the values given in Table 1017.2. <br />Max Travel Distance for Assembly Occupancy (Without Sprinkler System): 200' <br />·CBC 2022 - 1010.1.1 Size of Doors <br />The required capacity of each door opening shall be sufficient for the occupant load thereof and shall provide a minimum clear <br />opening width of 32 inches (813 mm). The clear opening width of doorways with swinging doors shall be measured between the face <br />of the door and the stop, with the door open 90 degrees (1.57 rad). <br />·CBC 2022 - 1010.2.3 Hardware Height: <br />Door handles, pulls, latches, locks and other operating devices shall be installed 34 inches (864 mm) minimum and 48 inches (1219 <br />mm) maximum above the finished floor. <br />·CBC 2022 - 1030.8 Common Path of Egress Travel <br />The common path of egress travel shall not exceed 30 feet (9144 mm) from any seat to a point where an occupant has a choice of two <br />paths of egress travel to two exits. <br />Exceptions: <br />For areas serving less than 50 occupants, the common path of egress travel shall not exceed 75 feet (22 860 mm). <br />For smoke-protected or open-air assembly seating, the common path of egress travel shall not exceed 50 feet (15 240 mm). <br />·CBC 2022 - 1030.9.1 Minimum Aisle Width <br />The minimum clear width for aisles shall comply with one of the following: <br /> 4. Forty-two inches (1067 mm) for level or ramped aisles having seating on both sides. <br /> Exceptions: <br />-Thirty-six inches (914 mm) where the aisle serves less than 50 seats. <br /> 5. Thirty-six inches (914 mm) for level or ramped aisles having seating on only one side. <br />OCCUPANCY LOAD CALCULATIONS <br />ROOM NAME OCCUPANCY AREA (SF)OCCUPANT LOAD FACTOR <br />(SF/OCCUPANT) <br />NUMBER <br />OF OCCUPANTS (NOT ROUNDED) <br />NUMBER OF OCCUPANTS <br />(ROUNDED) <br />RECEPTION 131.58 5 26.32 27 <br />DINNING 1 287.24 15 19.15 20 <br />DINING 2 92.78 15 6.19 7 <br />DINING 3 228.18 15 15.21 16 <br />KITCHEN 226.77 200 1.13 2 <br />STORAGE 53.73 -1.00 1 <br />TOTAL 1020.28 -69.00 73 <br />OCCUPANCY LOADO.L. <br />59'-9"18'-2"5'-8" <br />20 <br />' <br />- <br />7 <br />" <br />2'-11" <br />41 <br />2" <br />18'-6" <br />41 <br />2" <br />7'-61 <br />2" <br />41 <br />2" <br />6'-2" <br />41 <br />2" <br />22'-8" <br />8' <br />- <br />7 <br />" <br />12 <br />' <br />- <br />0 <br />" <br />15'-5"5'-0"16'-4" <br />18 <br />' <br />- <br />2 <br />" <br />STORAGE <br />ADA REST RM <br />83'-7" <br />EX <br />I <br />T <br />EX <br />I <br />T <br />D1 <br />5'-71 <br />2" <br />RECEPTION3' <br />- <br />1 <br />0 <br />1 2" <br />W1 <br />W2 <br />W2 <br />N <br />8' <br />- <br />4 <br />" <br />4' <br />- <br />3 <br />1 2" <br />12'-10" <br />ST <br />A <br />F <br />F <br /> <br />O <br />N <br />L <br />Y <br />AR <br />E <br />A <br />SERVICE WINDOW <br />48"x12" <br />24 <br />" <br />x <br />2 <br />4 <br />" <br />24 <br />" <br />x <br />2 <br />4 <br />" <br />36 <br />" <br />x <br />1 <br />2 <br />" <br />18 <br />" <br />x <br />2 <br />4 <br />" <br />48"x24" <br />20 <br />36"x12" <br />2 <br />48'-10'' <br />28'-9" <br />51'-7'' <br />38' <br />27'-4'' <br />8'-7'' <br />51'-4'' <br />O.L: 4 OCCUPANTS <br />O.L: 27 OCCUPANTS <br />O.L: 1 OCCUPANT <br />57'-0'' <br />2'-9" <br />5' <br />- <br />1 <br />0 <br />" <br />O.L: 12 PEOPLE <br />ADJACENT TENANT: GROUP B OCCUPANCY <br />ADJACENT TENANT: GROUP R OCCUPANCY <br />(E) NON-RATED WALL <br />(E) NON-RATED WALL <br />ADJACENT TENANT: GROUP M OCCUPANCY <br />(E) NON-RATED WALL <br />(E) NON-RATED WALL <br />(E) NON-RATED WALL <br />ADJACENT TENANT: GROUP B OCCUPANCY <br />DINING 2 DINING 1 <br />O.L: 3 OCCUPANTS <br />O.L: 2 OCCUPANTS <br />KITCHEN <br />STAFF SERVICE ONLY AREA COMPLEMENTARY <br />TO DINING AREAS 1, 2 AND 3) <br />Fixed Booth <br />Seating, <br />Anchored, <br />Fixed Booth <br />Seating, <br />Anchored,Fixed Booth <br />Seating, <br />Anchored, <br />Fixed Booth <br />Seating, <br />Anchored, <br />Fixed Booth <br />Seating, <br />Anchored, <br />Fixed Booth <br />Seating, <br />Anchored, <br />Fixed Booth <br />Seating, <br />Anchored, <br />Fixed Booth <br />Seating, <br />Anchored, <br />Fixed Booth <br />Seating, <br />Anchored, <br />Fixed Booth <br />Seating, <br />Anchored, <br />10 OF 13 <br />PR <br />O <br />P <br />O <br />S <br />E <br />D <br /> <br />E <br />G <br />R <br />E <br />S <br />S <br />PL <br />A <br />N <br />A02 <br />DRAWN <br />CHECKED <br />DATE <br />SCALE <br />Y.A. <br />AS NOTED <br />Y.A. <br />REVISIONS <br />SHEET NUMBER <br />ALL THE DRAWINGS, <br />SPECIFICATIONS & IDEAS, <br />DESIGNS & ARRANGEMENTS <br />REPRESENTED THEREBY <br />ARE AND SHALL REMAIN <br />THE PROPERTY OF THE <br />DESIGNERS AND BUILDERS. <br />NO PART THEREOF SHALL <br />BE COPIED, DISCLOSED TO <br />OTHERS, OR USED IN <br />CONNECTION WITH ANY <br />WORK OR PROJECT <br />WITHOUT THE WRITTEN <br />CONSENT OF THE <br />DESIGNER. <br />No DATE <br />March 12, 2026 <br />TE <br />N <br />A <br />N <br />T <br /> <br />I <br />M <br />P <br />R <br />O <br />V <br />E <br />M <br />E <br />N <br />T <br />HE <br />X <br />E <br />S <br /> <br />& <br /> <br />B <br />R <br />E <br />W <br />S <br /> 30 <br />2 <br /> <br />N <br /> <br />B <br />r <br />o <br />a <br />d <br />w <br />a <br />y <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />, <br /> <br />U <br />S <br />A <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />O <br />W <br />N <br />E <br />R <br />: <br /> <br />C <br />I <br />V <br />I <br />C <br /> <br />C <br />E <br />N <br />T <br />E <br />R <br /> <br />R <br />E <br />A <br />L <br />T <br />Y <br /> <br />3 <br />0 <br />0 <br />, <br /> <br />L <br />L <br />C <br />. <br /> <br />A <br />CA <br />L <br />I <br />F <br />O <br />R <br />N <br />I <br />A <br /> <br />L <br />I <br />M <br />I <br />T <br />E <br />D <br /> <br />L <br />I <br />A <br />B <br />I <br />L <br />I <br />T <br />Y <br /> <br />C <br />O <br />M <br />P <br />A <br />N <br />Y <br />01 2024/19/06 <br />HD01 2024/13/09 <br />HD02 2024/18/10 <br />PROPOSED EGRESS PLAN- SCALE 1/4"=1'-0" <br />Charles F. Starck, RA, AIA <br />Digitally signed by Charles F. Starck, <br />RA, AIA <br />DN: C=US, <br />E=charles@starckarchitecture.com, <br />O=C. F. Starck & Associates LLC, <br />CN="Charles F. Starck, RA, AIA" <br />Location: Thompson's Station, TN <br />37179 <br />Reason: I am the author of this <br />document <br />Contact Info: <br />charles@starckarchitecture.com <br />Date: 2026.03.13 08:45:06-05'00'