Laserfiche WebLink
62.02'PROPERTY LINE <br />62.02'PROPERTY LINE <br />15 <br />4 <br />. <br />6 <br />6 <br />' <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />15 <br />4 <br />. <br />6 <br />6 <br />' <br />SCALE 1/8"=1'-0" <br />SITE PLAN <br />1432 N. BAKER ST. UNIT #2 <br />SINGLE FAMILY DWLG. <br />2,594.00 S.F. <br />EXISTG. 2-STORY <br />NOTE: THE APPLICANT/PROPERTY OWNER SHALL BE RESPONSIBLE <br />FOR CONFIRMING ALL EXISTING UTILITY EASEMENTS AND/OR <br />CLEARANCES ON-SITE THAT MAY AFFECT THE PROJECT. <br />EXIST. PORCH <br /> REAR YARD <br />EXIST. LANDSCAPE <br />FRONT YARD <br />EXIST. LANDSCAPE <br />TO BE ADU <br />297.00 S.F. <br />EXISTG. GARAGE <br />EXIST. BRICK. WALKWAY <br />EXIST. PATIO <br />EX <br />I <br />S <br />T <br />. <br /> <br /> <br />C <br />O <br />N <br />C <br />. <br /> <br />D <br />R <br />I <br />V <br />E <br />W <br />A <br />Y <br />EX <br />I <br />S <br />T <br />. <br /> <br /> <br />C <br />O <br />N <br />C <br />. <br /> <br />D <br />R <br />I <br />V <br />E <br />W <br />A <br />Y <br />EX <br />I <br />S <br />T <br />. <br /> <br /> <br />C <br />O <br />N <br />C <br />. <br /> <br />D <br />R <br />I <br />V <br />E <br />W <br />A <br />Y <br />EXISTG. SWIMMING POOL <br />EX <br />I <br />S <br />T <br />. <br /> <br /> <br />S <br />I <br />D <br />E <br /> <br /> <br />Y <br />A <br />R <br />D <br />EX <br />I <br />S <br />T <br />. <br /> <br /> <br />S <br />I <br />D <br />E <br /> <br /> <br />Y <br />A <br />R <br />D <br />11 <br />' <br />- <br />2 <br />" <br />18 <br />' <br />- <br />2 <br />" <br />13 <br />' <br />- <br />3 <br />" <br />1'-3"16'-4"5'-0"39'-5" <br />NORTH <br />(EXISTG.) DRIVEWAY <br />APPROACH(E) CURB & GUTTER <br />EXISTG. SIDEWALK <br />EXISTG. PARKWAY <br />PROVIDE SAND BAGS <br />PROVIDE 6'-0" HIGH <br />TEMPORARY CHAIN LINK FENCE <br />********* <br />(EXISTG.) WALKWAY <br />APPROACH <br />A <br />A-2 <br />1%MI <br />N <br />1%MI <br />N <br />1%MI <br />N <br />1%MI <br />N <br />1%MI <br />N1%MI <br />N <br />1%MI <br />N <br />1%MI <br />N <br />1%MI <br />N <br />1%MI <br />N <br />1%MI <br />N <br />5% <br />5% <br />5%5% <br />5%5% <br />(E) TREE <br />(E) BUSHES <br />36 <br />' <br />- <br />6 <br />" <br />49 <br />' <br />- <br />5 <br />" <br />68 <br />' <br />- <br />8 <br />" <br />NOTE: NO EASEMENT ON PROPERTY <br />(E <br />) <br /> <br />3 <br />F <br />T <br /> <br />H <br />I <br />G <br />H <br /> <br />B <br />L <br />O <br />C <br />K <br /> <br />F <br />E <br />N <br />C <br />E <br />(E <br />) <br /> <br />6 <br /> <br />F <br />T <br /> <br />H <br />I <br />G <br />H <br /> <br />B <br />L <br />O <br />C <br />K <br /> <br />F <br />E <br />N <br />C <br />E <br />(E <br />) <br /> <br />6 <br /> <br />F <br />T <br /> <br />H <br />I <br />G <br />H <br /> <br />B <br />L <br />O <br />C <br />K <br /> <br />F <br />E <br />N <br />C <br />E <br />(E <br />) <br /> <br />6 <br /> <br />F <br />T <br /> <br />H <br />I <br />G <br />H <br /> <br />V <br />I <br />N <br />Y <br />L <br /> <br />F <br />E <br />N <br />C <br />E <br />(E <br />) <br /> <br />6 <br /> <br />F <br />T <br /> <br />H <br />I <br />G <br />H <br /> <br />V <br />I <br />N <br />Y <br />L <br /> <br />F <br />E <br />N <br />C <br />E <br />(E) 6 FT HIGH VINYL FENCE <br />PROVIDE 6'-0" HIGH <br />VINYL GATE <br />11 <br />' <br />- <br />0 <br />" <br />23'-0" <br />TANKLESS <br />WATER HEATER <br />(E) GAS METER <br />(N) GAS METER <br />(N <br />) <br /> <br />G <br />A <br />S <br /> <br />L <br />I <br />N <br />E <br /> <br />T <br />O <br /> <br />A <br />D <br />U <br />(N) GAS LINE <br />(E) SEWER LATERAL <br />(N <br />) <br /> <br />S <br />E <br />W <br />E <br />R <br /> <br />L <br />I <br />N <br />E <br />(N <br />) <br /> <br />S <br />E <br />W <br />E <br />R <br /> <br />L <br />I <br />N <br />E <br />(E <br />) <br /> <br />S <br />E <br />W <br />E <br />R <br /> <br />L <br />I <br />N <br />E <br />(E <br />) <br /> <br />S <br />E <br />W <br />E <br />R <br /> <br />L <br />I <br />N <br />E <br />VERIFY <br />(E) 4" SEWER <br />LATERAL <br />(N) 4" SEWER <br />LATERAL <br />(N) 100 AMP <br />SUBPANEL <br />(E) ELECTRICAL <br />PANEL <br />(N) 100 AMP <br />ELECTRICAL <br />SUB-PANEL <br />(E) WATER METER <br />(N <br />) <br /> <br />W <br />A <br />T <br />E <br />R <br /> <br />L <br />I <br />N <br />E <br />(E <br />) <br /> <br />W <br />A <br />T <br />E <br />R <br /> <br />L <br />I <br />N <br />E <br />(N) <br />W <br />A <br />T <br />E <br />R <br /> <br />L <br />I <br />N <br />E <br />(E)UNPERMITTED <br />CARPORT <br />STRUCTURE TO <br />BE REMOVED <br />A <br />A <br />10'-3" <br />REF. <br />SCALE 1/4"=1'-0" <br />ADU FLOOR PLAN <br />LEGEND: <br />PROPOSED <br />EXISTING <br />REMOVE <br />4'-0" <br />CLOSET <br />BATH <br />10'-1" <br />14 <br />' <br />- <br />1 <br />1 <br />" <br />15'-6" <br />9' <br />- <br />5 <br />" <br />HIGH EFFICIENCY FIXTURES <br />ELECTRICAL LEGEND <br />G.F.I. <br />SWITCHES <br />FLUORESCENT <br />FIXTURE 40 LUM <br />A.F.C.I. <br />ARC FAULT CURRENTINTERRUPTER RECEPTACLE <br />H.E. <br /> SENSOR OFF <br />ON AND PHOTO-CONTROLLED <br />LIGHTING W/ MOTION SENSORP <br />SWITCHES W/ DIMMERD <br />G.F.I. W/P WP/GFI OUTLET TYP. <br />EXHAUST FAN- CAPABLE OF 5 AIR <br />CHANGES/HOUR IN BATHROOM AND/OR <br />TOILET ROOM. HUMIDISTAT <br />CONTROLLED <br />SD <br />HARD-WIRED CARBON MONOXIDE <br />ALARM WITH BATTERY BACKUP CO <br />LIGHT FIXTURES <br />ELECTRICAL RECEPTACLE TAMPER <br />PROOF1 <br />WARDROBE SHELF & POLE2 <br />3 <br />4 <br />5 <br />6 <br />FLOOR PLAN KEYNOTES <br />WATER CLOSET SHALL BE ULTRA LOW FLUSH TYPE WITH 1.28 GAL. MAX. PER FLUSH. <br />HOSE BIBB W/ BACKFLOW PREVENTER <br />7 <br />ENERGY STAR EXHAUST FAN W/ 5-AIR CHANGES PER HOUR EXHAUSTING DIRECTLY <br />TO THE OUTSIDE/ 50 CFM EXHAUST PER CGBSC 4.506.1. WITH HUMIDITY CONTROL <br />LANDING <br />8 <br />9 <br />10" X 19" STOVE TOP <br />16" X 14" S. STL SINK W/ GARB. DISPOSAL ON A SEPARATE CIRCUIT. <br />10 <br />F.A.U. IN ATTIC 13.5EER CAPACITY HEATER & COOLER SEE NOTES <br />30"X30" ATTIC ACCESS W/ 30" MIN. HEADRM. W/ WEATHER STRIPS TO <br />PREVENT BACK DRAFT. <br />11 <br />12 <br />GRAB BARS NOTES <br />A.REINFORCEMENT FOR GRAB BARS. [R327.1.1] AT LEAST ONE BATHROOM ON THE ENTRY LEVEL <br />SHALL BE PROVIDED WITH REINFORCEMENT INSTALLED IN ACCORDANCE WITH THIS SECTION. <br />WHERE THERE IS NO BATHROOM ON THE ENTRY LEVEL, AT LEAST ONE BATHROOM ON THE 2ND <br />OR 3RD FLOOR OF THE DWELLING SHALL COMPLY WITH THIS SECTION. <br />1.REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS APPROVED BY <br />THE ENFORCING AGENCY. <br />2.REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 INCH NOMINAL LUMBER (1-1/2” X 7-1/4” ACTUAL <br />DIMENSION) OR OTHER CONSTRUCTION MATERIAL PROVIDING EQUAL HEIGHT AND LOAD <br />CAPACITY. REINFORCEMENT SHALL BE LOCATED BETWEEN 32” AND 39-1/4” ABOVE THE FINISHED <br />FLOOR, FLUSH WITH THE WALL FRAMING. <br />3.WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE FIXTURE, OR <br />ONE SIDE WALL AND THE BACK WALL. <br />4.SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED. <br />5.BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT SHALL BE CONTINUOUS ON <br />EACH END OF THE BATHTUB AND THE BACK WALL. ADDITIONALLY, BACK WALL REINFORCEMENT <br />FOR A LOWER GRAB BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE LOCATED NO MORE THAN <br />6” ABOVE THE BATHTUB RIM. <br />6.WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO A SIDE WALL CAPABLE OF <br />ACCOMMODATING A GRAB BAR, THE BATHROOM SHALL HAVE PROVISIONS FOR INSTALLATION OF <br />FLOOR-MOUNTED, FOLDAWAY OR SIMILAR ALTERNATE GRAB BAR REINFORCEMENTS APPROVED <br />BY THE ENFORCING AGENCY. <br />B.DOCUMENTATION FOR GRAB BAR REINFORCEMENT. [R327.1.1.1] INFORMATION AND/OR DRAWINGS <br />IDENTIFYING THE LOCATION OF GRAB BAR REINFORCEMENT SHALL BE PLACED IN THE OPERATION <br />& MAINTENANCE MANUAL IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS <br />CODE, CH. 4, DIVISION 4.4. <br />C.ELECTRICAL RECEPTACLE OUTLET, SWITCH & CONTROL HEIGHTS. [R327.1.2] ELECTRICAL <br />RECEPTACLE OUTLETS, SWITCHES AND CONTROLS (INCLUDING CONTROLS FOR HEATING, <br />VENTILATION AND AIR CONDITIONING) INTENDED TO BE USED BY OCCUPANTS SHALL BE LOCATED <br />NO MORE THAN 48” MEASURED FROM THE TOP OF THE OUTLET BOX AND NOT LESS THAN 15” <br />MEASURED FROM THE BOTTOM OF THE OUTLET BOX ABOVE THE FINISH FLOOR. <br />D.INTERIOR DOORS. [R327.1.3] EFFECTIVE JULY 1, 2024, AT LEAST ONE BATHROOM AND ONE <br />BEDROOM ON THE ENTRY LEVEL SHALL PROVIDE A DOORWAY WITH A NET CLEAR OPENING OF <br />NOT LESS THAN 32”, MEASURED WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM <br />THE CLOSED POSITION; OR, IN THE CASE OF A 2- OR 3-STORY SINGLE FAMILY DWELLING, ON THE <br />2ND OR 3RD FLOOR OF THE DWELLING IF A BATHROOM OR BEDROOM IS NOT LOCATED ON THE <br />ENTRY LEVEL. <br />E.DOORBELL BUTTONS. [R327.1.4] DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED, SHALL <br />NOT EXCEED 48” ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE <br />DOORBELL BUTTON ASSEMBLY. WHERE DOORBELL BUTTONS INTEGRATED WITH OTHER <br />FEATURES ARE REQUIRED TO BE INSTALLED ABOVE 48” MEASURED FROM THE EXTERIOR FLOOR <br />OR LANDING, A STANDARD DOORBELL BUTTON OR CONTROL SHALL ALSO BE PROVIDED AT A <br />HEIGHT NOT EXCEEDING 48” ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF <br />THE DOORBELL BUTTON OR CONTROL. <br />SMOKE DETECTOR SHALL BE INTERCONNECTED SUCH THAT THE ACTIVATION OF ONE ALARM WILL <br />ACTIVATE ALL ALARMS. <br />A MINIMUM OF 20 FT. FROM PERMANENT COOKING EQUIPMENT (OR 10' WITH PHOTO-ELECTRIC TYPE). <br />SMOKE ALARM AND DETECTORS WILL BE INSTALLED AND MAINTAINED ACCORDING TO <br />MANUFACTURER'S INSTRUCTIONS. <br />HARDWIRED SMOKE DETECTOR W/ <br />BATTERY BACK-UP (PHOTO ELECTRIC) <br />WATER HEATING. SYSTEMS USING GAS OR PROPANE WATER HEATERS TO SERVE INDIVIDUAL <br />DWELLING UNITS SHALL INCLUDE THE FOLLOWING COMPONENTS [150.0(N)]: <br />A.A DEDICATED 125V, 20A (10 AWG COPPER BRANCH CIRCUIT) ELECTRICAL RECEPTACLE <br />THAT IS WITHIN 3 FEET FROM THE WATER HEATER AND ACCESSIBLE TO THE WATER <br />HEATER WITH NO OBSTRUCTIONS. THERE SHALL BE A RESERVED SINGLE POLE BREAKER <br />SPACE IN THE ELECTRICAL PANEL LABELED "FUTURE 240V USE". BOTH ENDS OF THE <br />UNUSED CONDUCTOR SHALL BE LABELED WITH THE WORD “SPARE” AND BE <br />ELECTRICALLY ISOLATED. <br />B.A CONDENSATE DRAIN THAT IS NO MORE THAN 2 INCHES HIGHER THAN THE BASE OF THE <br />INSTALLED WATER HEATER, AND ALLOWS NATURAL DRAINING WITHOUT PUMP <br />ASSISTANCE. <br />C.DESIGNATE A SPACE AT LEAST 2.5 FT. BY 2.5 FT. WIDE AND 7 FT. TALL SUITABLE FOR THE <br />FUTURE INSTALLATION OF A HEAT PUMP WATER HEATER (HPWH). <br />D.IF DESIGNATED SPACE IS MORE THAN 3 FEET FROM WATER HEATER, COMPLY WITH <br />150.0(N)B. <br />A.ELECTRIC COOKTOP READY. SYSTEMS USING GAS OR PROPANE COOKTOP TO SERVE <br />INDIVIDUAL DWELLING UNITS SHALL INCLUDE THE FOLLOWING: <br />1.A DEDICATED 240 VOLT BRANCH CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3 FT. FROM THE <br />COOKTOP AND ACCESSIBLE TO THE COOKTOP WITH NO OBSTRUCTIONS. THE <br />BRANCH CIRCUIT CONDUCTORS SHALL BE RATED AT 50 AMPS MINIMUM. THE BLANK <br />COVER SHALL BE IDENTIFIED AS “240V READY”. <br />2.THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED SPACE TO ALLOW FOR THE <br />INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKER FOR A FUTURE ELECTRIC <br />COOKTOP INSTALLATION. THE RESERVED SPACE SHALL BE PERMANENTLY MARKED <br />AS “FOR FUTURE 240V USE.” <br />B.ELECTRIC CLOTHES DRYER READY. CLOTHES DRYER LOCATIONS WITH GAS OR PROPANE <br />PLUMBING TO SERVE INDIVIDUAL DWELLING UNITS SHALL INCLUDE THE FOLLOWING: <br />1.A DEDICATED 240 VOLT BRANCH CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3 FT. FROM THE <br />CLOTHES DRYER LOCATION AND ACCESSIBLE TO THE CLOTHES DRYER LOCATION <br />WITH NO OBSTRUCTIONS. THE BRANCH CIRCUIT CONDUCTORS SHALL BE RATED AT <br />30 AMPS MINIMUM. THE BLANK COVER SHALL BE IDENTIFIED AS “240V READY.” <br />2.THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED SPACE TO ALLOW FOR THE <br />INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKER FOR A FUTURE ELECTRIC <br />CLOTHES DRYER INSTALLATION. THE RESERVED SPACE SHALL BE PERMANENTLY <br />MARKED AS “FOR FUTURE 240V USE.” <br />VACANCY SENSORVS <br />SHOW COMPLIANCE WITH THE FOLLOWING LIGHTING MEASURES: [150.0(K) / 160.5(A)] <br />1.A.LIGHTING IN BATHROOMS, GARAGES, LAUNDRY ROOMS, WALK-IN CLOSETS AND UTILITY <br />ROOMS. ALL LUMINAIRES SHALL BE HIGH EFFICACY AND SHALL BE CONTROLLED BY <br />AN OCCUPANCY OR VACANCY SENSOR <br />NOTE: HIGH EFFICACY LUMINARIES MUST BE PIN BASED <br />IN ADDITION TO THE LOCAL EXHAUST FANS IN THE BATHROOMS <br />AND KITCHENS, AN EXHAUST FAN SHALL BE SIZED TO PROVIDE <br />VENTILATION FOR THE WHOLE HOUSE. THE MINIMUM VENTILATION <br />RATE FOR THE IAQ FAN SHALL BE CALCULATED ACCORDING TO <br />ASHRAE STANDARD 62.2 AND 150.0(O)C / 160.2. ONE OF THE LOCAL <br />EXHAUST FANS IN THE BATHROOMS OR KITCHENS MAY BE USED <br />TO MEET THE WHOLE-BUILDING VENTILATION, PROVIDED THE <br />EXHAUST FAN MEETS THE MINIMUM VENTILATION RATED FOR <br />BOTH THE LOCAL EXHAUST AND IAQ REQUIREMENTS. THE <br />DUCTING FOR THE WHOLE BUILDING EXHAUST FAN SHALL BE <br />SIZED ACCORDING TO TABLE 150.0-H / 160.2-H, AND THIS EXHAUST <br />FAN SHALL OPERATE CONTINUOUSLY. <br />THE WHOLE-BUILDING VENTILATION EXHAUST FAN WILL OPERATE <br />CONTINUOUSLY AND IS REQUIRED TO BE RATED FOR SOUND AT A <br />MAXIMUM OF 1 SONE. THIS EXHAUST FAN CAN BE CONTROLLED BY <br />A STANDARD ON/OFF SWITCH BUT THE SWITCH MUST BE LABELED <br />CLEARLY DISPLAYING THE FOLLOWING TEXT, OR EQUIVALENT: <br />“THIS SWITCH CONTROLS THE INDOOR AIR QUALITY VENTILATION <br />FOR THE HOME. LEAVE SWITCH IN THE 'ON' POSITION AT ALL <br />TIMES UNLESS THE OUTDOOR AIR QUALITY IS VERY POOR.” <br />[150.0(O)J] <br />WATER HEATERS SHALL BE ANCHORED OR STRAPPED TO THE <br />STRUCTURE [CPC 507.2]. <br />A KITCHEN IS DEFINED AS ANY ROOM CONTAINING COOKING APPLIANCES. EACH KITCHEN IS <br />REQUIRED TO HAVE AN EXHAUST FAN DUCTED TO THE OUTSIDE WITH A MINIMUM VENTILATION RATE <br />AND CAPTURE EFFICIENCY PER TABLE 150.0-G OR TABLE 160.2-G (MULTI-FAMILY). THE RANGE HOOD <br />OVER THE STOVE MAY BE USED TO MEET THIS REQUIREMENT BUT THE RANGE HOOD MUST VENT TO <br />THE OUTSIDE; RECIRCULATING RANGE HOODS CANNOT BE USED. THE DUCTING FOR THE EXHAUST <br />FAN SHALL BE SIZED ACCORDING TO ASHRAE STANDARD 62.2 TABLE 7.1. THIS LOCAL EXHAUST FAN <br />MAY OPERATE CONTINUOUSLY OR INTERMITTENTLY. INSTALLING THIS LOCAL EXHAUST FAN IN THE <br />KITCHEN WILL ALLOW THE HOME OCCUPANT TO REGULATE THE INDOOR AIR QUALITY WHEN NEEDED. <br />100 CFM IS NOT ADEQUATE; 280 CFM FAN REQUIRED PER TABLE 150.0-G. <br />GROUND FAULT FOR 120 VOLT, 15/20AMP RECEPTACLE <br />STUDY <br />KITCHEN <br />5'-8" <br />3'-0" <br />4' <br />- <br />0 <br />" <br />7 <br />7 <br />7' <br />- <br />9 <br />" <br />10 <br />' <br />- <br />1 <br />" <br />16'-4" <br />18 <br />' <br />- <br />2 <br />" <br />16'-4" <br />18 <br />' <br />- <br />2 <br />" <br />1 5'-0" X 3'-6" <br />2 <br />SYM. SIZE TYPE <br />WINDOW SCHEDULE <br />VINYL SLID. <br />3 <br />4'-0" X 4'-0" <br />3'-0" X 1'-0" <br />VINYL SLID. <br />VINYL SLID. <br />TEMPERED GLASS <br />U-FACTOR SHGC <br />0.30 0.23 <br />0.30 0.23 <br />0.30 0.23 <br />DOOR SCHEDULE <br />SYM. SIZE <br />A HOLLOW CORE <br />B <br />TYPE <br />C <br />DOOR SCHEDULE <br />SYM. SIZE <br />A HOLLOW CORE <br />B <br />TYPE <br />C <br />2'-10"X6'-8"X1 3/8" <br />D <br />SOLID CORE3'-0" X 6'-8" X 1 3/4" <br />E <br />6'-0" X 6'-8"SLID. WOOD <br />DBL. DRS. <br />2 <br />1 <br />2' <br />- <br />8 <br />" <br />15 <br />' <br />- <br />7 <br />" <br />3' <br />- <br />0 <br />" <br />30 <br />" <br /> <br />M <br />I <br />N <br />. <br />24" MIN. <br />5'-0" <br />A.F.C.I.A.F.C.I. <br />A.F.C.I. <br />A.F.C.I. <br />A.F.C.I. <br />A.F.C.I. <br />A.F.C.I. <br />G.F.I.G.F.I.G.F.I.G.F.I. <br />G.F.I. <br />VS <br />D <br />P <br />P <br />SOLID CORE2'-8"X6'-8"X1 3/8" <br />B <br />D1" MAX. <br />DIFF. <br />A <br />C <br />SD CO <br />SHOWER WITH CEMENT PLASTER, TILE, OR APPROVED COVERING EQUAL WITH 72" <br />(MINIMUM) HIGH ABOVE DRAIN NON-ABSORBENT WALLS. MATERIALS OTHER THAN <br />STRUCTURAL ELEMENTS ARE TO BE MOISTURE RESISTANT <br />1 <br />2 <br />3 <br />4 <br />F.A.U. <br />IN ATTIC <br />10 <br />5 8 <br />9 <br />G.F.I. <br />W/P <br />G.F.I. <br />W/P <br />3 TEMP <br />GLASS <br />1-HR FIRE RATED WALL <br />EXHAUST FAN W/ 20 CFM <br />Single-Speed Whole House Ventilation <br />Fan from the Eco-Exhaust Series PER <br />ASHRAE 62.2 <br />MANUFACTURER: AIRKING EVD <br />WHOLE HOUSE VENTILATION <br />a. Qr= 0.01 X 297.00 +7.5 (1+1) <br />a. Qr= 0.01 X 770.00 +15.00 = 17.97 cfm <br />b. 1 Sone max <br />c. 4" duct 15'-0" max length <br />1" MAX. <br />DIFF. <br />2" X 6" BACKING <br />FOR FUTURE GRAB <br />BAR INSTALLATION <br />SEE DETAIL 1/A-2 <br />30" <br /> <br />M <br />I <br />N <br />A-2 <br />X <br />TANKLESS <br />WATER HEATER <br />1'-8" X 6'-8" X 1 3/4"SOLID CORE W/ LOUVER <br />VENTS <br />TEMPERED GLASS <br />TEMP <br />GLASS <br />6 <br />SHOWER DOOR TO <br />BE TEMPERED <br />GLASS <br />2'-10" <br />DOOR ALARM FOR <br />POOL <br />15 <br />" <br />MI <br />N <br />15 <br />" <br />MI <br />N <br />(N) 100 AMP <br />ELECTRICAL <br />SUB-PANEL <br />LAUNDRY <br />A <br />A <br />A <br />A-1 <br />SITE PLAN, FLOOR PLAN <br />ISSUES AND REVISIONS <br />Computer File <br />Project Name <br />Description <br />Project Number <br />SHEET: <br />Scale <br />NO. <br />1. <br />DATE <br />2. <br />3. <br />CHECKBY <br />CONSULTANT <br />CONTACT: <br />PROPOSED GARAGE <br />CONVERSION INTO <br />ADU <br />SEAL: <br />VERIFY MEASUREMENTS WITH CORRESPONDING <br />COSTRUCTED OR EXISTING CONDITIONS PRIOR TO <br />PROCEEDING WITH THE WORK, AND NOTIFY THE <br />ARCHITECT IMMEDIATELY OF SIGNIFICANT <br />DISCREPANCIES. <br />FINISH ELEVATIONS REFERENCED ON ARCHITECTURAL <br />DRAWINGS ARE DATUM ELEVATIONS ABOVE THE FINISH <br />FLOOR ELEVATION. THE CONTRACTOR MUST <br />COORDINATE DATUM-BASED ARCHITECTURAL <br />ELEVATIONS SHOWN WITH SITE-SPECIFIC ELEVATIONS <br />SHOWN ON CIVIL DRAWINGS. <br />WALL DIMENSIONS SHOWN ARE TO FACE OF WALL <br />FINISH UNLESS SPECIFICALLY NOTED OTHERWISE. <br />1432 N. BAKER ST. <br />SANTA ANA, CA 92706 <br />C&C <br />Drafting Design <br />Edgar Cortes <br />& Commercial <br />Residential <br />Design <br />1100 E. Orangethorpe Ave. <br />Ca. 92801 <br /># 200w, Anaheim <br /> (562) 916 7505 (714) 813 6555 <br />e_mail: ccdraftingdesign@yahoo.com <br />OWNER: <br />MRS. MINEL HERAS <br />Mobile: (562) 547 4249 <br />MRS. MOUREEN B. HERAS <br />Mobile: (562) 547-4249 <br />EMAIL: <br />INPROPERBUENAPARK@GMAIL.COM <br />A 2/05/2026 ROOF FRAMING PLAN, <br />RELOCATE WATER HEATER, <br />ELECTRICAL PANEL. <br />CONCRETE SLAB DETAIL AND <br />ROOF SHEATHING <br />A-1 <br />INDEX OF DRAWINGS <br />SITE PLAN, PROPOSED FLOOR PLAN <br />9,588.00 SQ.FT. <br />3,144.00 SQ.FT. <br />LOT AREA <br />TOTAL EXISTING AND PROPOSED <br />2,594.00 SQ.FT.EXISTING LIVING AREA <br />297.00 SQ.FT. <br />PROJECT DATA: <br />LOT COVERAGE = 3,144.00 SQ.FT. / 9,588.00 SQ.FT.X 100 =32.79% <br />TOTAL EXISTING HOUSE, GARAGE & ADDITION <br />SCOPE OF WORK: <br />PROPOSED GARAGE CONVERSION INTO ADU: EXISTING GARAGE <br />297.00 SQ.FT. INTO ADU INCLUDE; STUDY, CLOSET, BATH, KITCHEN <br />AND LIVING/DINING AREA. <br />LEGEND <br />PROPOSED ADU <br />APPLICABLE CODES <br />BUILDING ANALYSIS <br />OCCUPANCY CLASSIFICATION: R3 <br />TYPE OF CONSTRUCTION: V-B <br />EXISTING 2-CAR GARAGE TO BE ADU <br />LEGAL DESCRIPTION <br />THE GOVERNING CODES FOR THIS PROJECT ARE <br />2022 CALIFORNIA BUILDING CODE <br />2022 CALIFORNIA PLUMBING CODE <br />2022 CALIFORNIA MECHANICAL CODE <br />2022 CALIFORNIA ELECTRIC CODE BASED ON NEC <br />2022 BUILDING ENERGY EFFICIENCY STANDARDS <br />SANTA ANA MUNICIPAL CODE <br />CA RESIDENTIAL CODE <br />ADU SPRINKLERS: NO <br />NUMBER OF STORIES: 1 <br />NOTES <br />ZONING: R-1 SINGLE FAMILY RESIDENCE ZONE <br />APN. 405-251-13 <br />MECHANICAL, ELECTRICAL, AND PLUMBING ARE NOT PART OF THIS PLAN <br />REVIEW AND APPROVAL. MEP ARE SUBJECT TO BUILDING FIELD <br />INSPECTION <br />VICINITY MAP <br />PROJECT LOCATION <br />A-2 ELEVATIONS, CROSS SECTION <br />GRN <br />GRN2 <br />S-1 FOUNDATION AND ROOF FRAMING PLAN <br />EN-1 ENERGY FORMS <br />GREEN MANDATORY MEASURES <br />GREEN MANDATORY MEASURES <br />EXISTING MAIN HOUSE SPRINKLERS: NO <br />253.00 SQ.FT.EXISTING PATIO <br />UTILITIES WILL BE UNDERGROUND <br />FLOOD ZONE: X <br />ADU SF / SFD SF = 297.00 SF / 2,594.00 SF = 0.11449 = 11.45% <br />THE ADU SF / SFD SF RATIO IS FOR PARK & REC FEE PURPOSE ONLY. THE <br />APPLICANT IS RESPONSIBLE FOR THE GIVEN “SFR SF” OF THE EXISTING <br />PRIMARY RESIDENCE; BUILDING SAFETY STAFF ARE NOT RESPONSIBLE FOR <br />THE ACCURACY OF THE GIVEN “SFR SF” OF THE EXISTING RESIDENCE. <br />ADU/SFD SF <br />KAMAL MCHANTAF <br />949-307-6346 <br />ENGINEER INFORMATION