ELECTRICAL ABBREVIATION KEY <br />AFF ABOVE FINISHED FLOOR <br />C CONDUIT <br />CO CONDUIT AND BOX ROUGH-IN ONLY (ROUGH-IN ONLY) <br />GFI GROUND FAULT INTERRUPTER <br />ABBR:DESCRIPTION: <br />TYP TYPICAL <br />UON UNLESS OTHERWISE NOTED <br />1. EXISTING CONDITIONS ARE SHOWN BASED ON INFORMATION OBTAINED FROM FIELD <br />SURVEYS, EXISTING BUILDING DOCUMENTS. CONTRACTOR SHALL REVIEW EXISTING <br />CONDITIONS AND REPORT CONFLICTS. <br />2. NOT ALL EXISTING EQUIPMENT, LUMINAIRES, AND CONDUIT ARE SHOWN. CONTRACTOR <br />SHALL REVIEW EXISTING CONDITIONS AND REPORT CONFLICTS. <br />3. ELECTRICAL CONTRACTOR SHALL REVIEW EXISTING CONDITIONS TO VERIFY ACCESSIBILITY <br />TO THE AREAS OF THEIR WORK INCLUDING WALLS, FLOOR, AND CEILINGS. ELECTRICAL <br />CONTRACTOR IS RESPONSIBLE TO PROVIDE CUTTING, REMOVAL, PATCHING, AND <br />REINSTALLATION OF AFFECTED AREAS ASSOCIATED WITH THEIR WORK BY COORDINATING <br />WITH THE GENERAL CONTRACTOR OR QUALIFIED CONTRACTOR. <br />4. WHERE EXISTING ELECTRICAL SYSTEMS ARE LOCATED IN AREAS THAT CONFLICT WITH NEW <br />EQUIPMENT, PIPING, OR DUCTWORK TO BE INSTALLED, EACH CONTRACTOR SHALL EITHER <br />ARRANGE NEW EQUIPMENT, CONDUIT, OR DUCTWORK IN SUCH A FASHION THAT IT DOES <br />NOT CONFLICT WITH EXISTING SYSTEMS, OR REWORK EXISTING ELECTRICAL SYSTEMS TO <br />ALLOW FOR INSTALLATION OF NEW EQUIPMENT, PIPING, OR DUCTWORK. <br />ELECTRICAL RENOVATION NOTES: <br />THESE NOTES APPLY TO ALL ELECTRICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED <br />TO LIGHTING AND POWER <br />26 05 33 JUNCTION BOXJ <br />ELECTRICAL SYMBOL LIST <br />SYMBOL:TAG:SPEC <br />SECTION:DESCRIPTION: <br />PANEL '###'PANELBOARD -SURFACE MOUNT <br />26 05 33 ELECTRICAL CONNECTIONE <br />E <br />SWITCH <br />SUBSCRIPTS: <br />3R= NEMA 3R WEATHERPROOF SWITCH <br />## <br />J <br />BRANCH CIRCUITS: LIGHTING, RECEPTACLES, <br />CONTROLS, ETC. <br />CONDUIT INSTALLATION SCHEDULE <br />THE FOLLOWING SCHEDULE SHALL BE ADHERED TO UNLESS THEY CONSTITUTE A VIOLATION OF <br />APPLICABLE CODES OR ARE NOTED OTHERWISE ON THE DRAW INGS. THE INSTALLATION OF RMC <br />CONDUIT WILL BE PERMITTED IN PLACE OF ALL CONDUIT SPECIFIED IN THIS SCHEDULE. REFER <br />TO CONDUIT AND BOXES SPECIFICATION 26 05 33 FOR ADDITIONAL INFORMATION. <br />INSTALLATION TYPE FMC <br />X <br />EMT <br />X <br />BRANCH CIRCUIT SCHEDULE <br />SYMBOL:DESCRIPTION: <br />CONDUIT HOMERUN TO PANELBOARD. LETTER AND NUMERALS <br />INDICATE ELECTRICAL PANEL AND CIRCUIT NUMBER. <br />PANEL -CIRCUIT <br />2022 CALIFORNIA BUILDING STANDARDS ADMINISTRATIVE CODE <br />CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 1 <br />2022 CALIFORNIA BUILDING CODE (CBC) <br />CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 2 <br />(2021 INTERNATIONAL BUILDING CODE (IBC) W/ 2022 CALIFORNIA AMENDMENTS) <br />2022 CALIFORNIA ELECTRICAL CODE (CEC) <br />CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 3 <br />(2020 NATIONAL ELECTRICAL CODE (NEC) W/ 2022 CALIFORNIA AMENDMENTS) <br />2022 CALIFORNIA MECHANICAL CODE (CMC) <br />CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 4 <br />(2021 UNIFORM MECHANICAL CODE (UMC) W/ 2022 CALIFORNIA AMENDMENTS) <br />2022 CALIFORNIA PLUMBING CODE (CPC) <br />CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 5 <br />(2021 UNIFORM MECHANICAL CODE (UPC) W/ 2022 CALIFORNIA AMENDMENTS) <br />2022 CALIFORNIA ENERGY CODE <br />CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 6 <br />2022 CALIFORNIA FIRE CODE (CFC) <br />CALIFORNIA CODES OF REGULATIONS (CRR) TITLE 24, PART 9 <br />(2021 INTERNATIONAL FIRE CODE (IFC) W/ 2022 CALIFORNIA AMENDMENTS) <br />2022 CALIFORNIA EXISTING BUILDING CODE <br />CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 10 <br />(2021 INTERNATIONAL EXISTING BUILDING CODE (IEBC)) <br />2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGREEN) <br />CALIFORNIA CODES OF REGULATIONS (CCR) TITLE 24, PART 11 <br />2022 CALIFORNIA REFERENCED STANDARDS CODE <br />CALIFORNIA DOE OF REGULATIONS (CCR) TITLE 24, PART 12 <br />APPLICABLE CODES AND STANDARDS: <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br />20" MAX. <br />44 <br />" <br /> <br />M <br />A <br />X <br />. <br />20"-25" MAX. <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br />15 <br />" <br /> <br />M <br />I <br />N <br />. <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br />46 <br />" <br /> <br />M <br />A <br />X <br />. <br />10" MAX.10"-24" MAX. <br />ADA STANDARDS -FRONT ACCESS <br />ADA STANDARDS FOR ACCESSIBLE DESIGN <br />INSTALL ABOVE COUNTER <br />DEVICE AT 44" ABOVE <br />FINISHED FLOOR. <br />INSTALL ABOVE COUNTER <br />DEVICE AT 40" ABOVE <br />FINISHED FLOOR. <br />INSTALL DEVICE AT 18" <br />ABOVE FINISHED FLOOR. <br />ADA STANDARDS -SIDE ACCESS <br />INSTALL DEVICE AT 44" <br />ABOVE FINISHED FLOOR. <br />INSTALL DEVICE AT 42" <br />ABOVE FINISHED FLOOR. <br />ELECTRICAL CONTRACTORE.C. <br />CONTRACTOR ABBREVIATION KEY <br />ABBR:DESCRIPTION: <br />VIEW KEY <br />LINE TYPE AND TAG KEY: <br />NEW WORK BY THIS CONTRACTOR (WIDE LINE) <br />EXISTING TO REMAIN <br />HALFTONING DOES NOT MODIFY SCOPE. <br />'TAG'-(E)TAGS WITH DASH 'E' INDICATES THE REFERENCED OBJECT IS EXISTING <br />'TAG'-(R)TAGS WITH DASH 'R' INDICATES THE REFERENCED OBJECT IS REMOVED <br />TAG-1 UNDERLINED TAG INDICATES OBJECT IS IN-SCOPE. IF NEW, ADDITIONAL <br />INFORMATION IS AVAILABLE IN A SCHEDULE, MATERIAL LIST, OR SYMBOL LIST <br />INDICATES AN EXISTING SYSTEM'S POINT OF CONNECTION/REMOVAL <br />PLAN OR DETAIL NUMBER <br />PLAN OR DETAIL NAME <br />PLAN OR DETAIL SCALE <br />DETAIL REFERRED TO BY SECTION CUT <br />SHEET DETAIL IS LOCATED ON <br />NAME <br />1 VIEW NAME <br />1/8" = 1'-0" <br />1 <br />M101 <br />1 <br />4 <br />3 <br />2 <br />SIMSIM <br />INDICATES SIMILAR DETAIL REFERENCED <br />IN MULTIPLE LOCATIONS <br />LEVEL NAME <br />10'-0"HEIGHT ABOVE <br />PROJECT 0'-0" <br />1 KEYNOTE: INDICATES NOTE USED TO <br />DESCRIBE ADDITIONAL INFORMATION <br />ABOUT WORK REQUIRED, SPECIFIC <br />TO THE SHEET AND/OR DETAIL <br />NO R HT <br />INDICATES DIRECTION OF TRUE NORTH <br />T101 <br />NEW <br />EXISTING TO BE REMOVED (SHORT DASHED PATTERN) <br />EXISTING (NARROW LINE PATTERN) <br />SCOPE OF WORK NOTES: <br />1. DEMOLITION OF EXISTING EXTERIOR SIGNAGE AND INSTALLATION OF NEW EXTERIOR <br />ILLUMINATED SIGNAGE. <br />1. THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE WITH THE ADA STANDARDS FOR <br />ACCESSIBLE DESIGN. REFER TO THE ADA GUIDELINES FOR ALL CONFIGURATION DETAILS ON <br />THIS PAGE FOR ADDITIONAL INFORMATION. <br />2. CIRCUIT NUMBERS ARE SHOWN FOR CIRCUIT IDENTIFICATION. CIRCUITING SHALL AGREE <br />WITH NUMBERING ON THE PANEL PROVIDED. COMMON NEUTRALS MAY NOT BE USED FOR <br />BRANCH CIRCUITS. <br />3. FLUSH MOUNT ALL LIGHTING CONTROL DEVICES AT +42" FROM FLOOR (CENTERLINE <br />DIMENSION), EXCEPT WHERE OTHERWISE NOTED. <br />4. FLUSH MOUNT ALL DUPLEX RECEPTACLES OUTLETS AT +18" FROM FLOOR (CENTERLINE <br />DIMENSION), EXCEPT WHERE OTHERWISE NOTED. <br />5. CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL CEILING MOUNTED DEVICES AND <br />EQUIPMENT WITH LUMINAIRES, SPRINKLER, AND CEILING DIFFUSERS. CENTER ALL DEVICES <br />IN CEILING TILE PATTERN. OCCUPANCY/VACANCY SENSORS SHALL BE LOCATED NO CLOSER <br />THAN 3 FEET TO AN AIR SUPPLY DIFFUSER OR RETURN GRILLE. <br />6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OPENINGS REQUIRED IN WALLS. ALL <br />OPENINGS SHALL BE REPAIRED TO MATCH EXISTING BY A QUALIFIED CONTRACTOR AT THE <br />EXPENSE OF THIS CONTRACTOR. ALL CONDUITS THROUGH W ALLS SHALL BE GROUTED OR <br />SEALED INTO OPENINGS. <br />7. EACH CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY THEIR ACTIONS TO THE <br />WALLS, FLOORS, AND CEILINGS. THE CONTRACTOR WHOSE WORK CAUSES DAMAGE IS <br />RESPONSIBLE FOR PATCHING TO MATCH ORIGINAL CONSTRUCTION, FIRE RATING, AND <br />FINISH. <br />8. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN, ELECTRICAL AND OTHER <br />ELECTRICAL PLANS FOR EXACT LOCATIONS OF ALL CEILING MOUNTED DEVICES, OTHER <br />THAN SPRINKLERS. <br />9. ELECTRICAL IDENTIFICATION. REFER TO SPECIFICATION SECTION 26 05 53 FOR COLOR/LABEL <br />REQUIREMENTS FOR CONDUIT, BOX, CABLE/WIRE, AND EQUIPMENT. <br />ELECTRICAL INSTALLATION NOTES: <br />TE OLIRFFOAC <br />LANRP <br />E 23191 <br />STA <br />ER <br />REGIST <br />ED <br />INA <br />N <br />REENIGE <br />FO OISSE <br />E AICLCERTL <br />Exp. 06/30/26 <br />MIRASOPHOCLISGEORGY <br />IMEG RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO <br />THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAW ING <br />AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG AND SHALL NOT <br />BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE <br />EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF IMEG. <br />©2024 IMEG CONSULTANTS CORP. <br />REF. SCALE IN INCHES <br />0 1 2 3 <br />222 S. HARBOR BOULEVARD <br />SUITE 800 <br />ANAHEIM, CA 92805 <br />P: 714.490.5555 F: 714.490.5560 <br />The FUTURE. Built Smarter www.imegcorp.com <br />PROJECT #24007312.00 <br />0 5' <br />GRAPHIC SCALES: <br />Issue Date <br />1/16" = 1'-0" <br />50' <br />1/8" = 1'-0"1/4" = 1'-0"1/2" = 1'-0"3/4" = 1'-0"1" = 1'-0"1-1/2" = 1'-0"3" = 1'-0" <br />0 5'25' 0 1'12' 0 1'6' 0 4' 0 3'1'0 2' 0 1' <br />Chckd By <br />Drwn By <br />Scale <br />Building ID: <br />KP Proj. No. <br />Permit No. <br />Sheet <br />SheetsOf <br />Sheet Title <br />Project <br />Facility <br />This document is the property of the Owner and is <br />Project Architect Approval: <br />Architect/Engineer Of Record: <br />IF THIS SHEET IS NOT 30"x42" , IT IS <br />A REDUCED PRINT - SCALE ACCORDINGLY <br />National Facilities Services <br />Post Office Box 12916 <br />Oakland California 94604 <br />not to be used without owner's written permission. <br />Floor Lev:Section: <br />HGW Proj. No. <br />© <br />A <br />R <br />C <br />H <br />I <br />T <br />E <br />C <br />T <br />S <br /> <br />h <br />a <br />n <br />n <br />a <br /> <br />g <br />a <br />b <br />r <br />i <br />e <br />l <br /> <br />w <br />e <br />l <br />l <br />s <br />, <br /> <br />a <br />l <br />l <br /> <br />r <br />i <br />g <br />h <br />t <br />s <br /> <br />r <br />e <br />s <br />e <br />r <br />v <br />ed <br />. <br /> <br /> <br />A <br />n <br />y <br /> <br />u <br />s <br />e <br /> <br />w <br />i <br />t <br />h <br />o <br />u <br />t <br /> <br />p <br />e <br />r <br />m <br />i <br />s <br />s <br />i <br />o <br />n <br /> <br />i <br />s <br /> <br />e <br />x <br />p <br />r <br />e <br />s <br />s <br />l <br />y <br /> <br />p <br />r <br />o <br />h <br />i <br />b <br />i <br />t <br />ed <br />. <br /> <br /> <br />P <br />l <br />o <br />t <br />t <br />e <br />d <br />CAP029271 <br />1955 Bacon Street. San Diego, CA 92107 <br />Office 619 523 8487 <br />www.hgwarchitecture.com <br />PROJECT #24007312.00 <br />Revisions <br />By Appr. <br />KAISER HARBOR MACARTHUR MOB <br />EXTERIOR SIGNAGE <br />KAISER PERMANENTE <br />HARBOR MACARTHUR MOB <br />As indicated <br />1/ <br />2 <br />3 <br />/ <br />2 <br />0 <br />2 <br />6 <br /> <br />1 <br />2 <br />: <br />4 <br />5 <br />: <br />5 <br />2 <br /> <br />P <br />M <br />01/23/2026 <br />MG <br />CL <br />ES001 <br />ELECTRICAL COVERSHEET <br />3401 South Harbor Boulevard, <br />Santa Ana, CA 92704 <br />10 <br />0 <br />% <br /> <br />C <br />D <br /> <br />S <br />E <br />T <br />2441 <br />ELECTRICAL SHEET INDEX <br />ES001 ELECTRICAL COVERSHEET <br />ES002 ELECTRICAL SPECIFICATIONS <br />ES003 ELECTRICAL SPECIFICATIONS <br />ES004 ELECTRICAL SPECIFICATIONS <br />ES102 LEVEL 02 - ELECTRICAL PLAN - OVERALL <br />ES103 LEVEL 03 - ELECTRICAL PLAN - OVERALL <br />ES122 LEVEL 02 - ENLARGED POWER PLAN <br />ES123 LEVEL 03 - ENLARGED POWER PLAN <br />ES400 PARTIAL SINGLE LINE DIAGRAM, PANEL SCHEDULES, LOAD CALCULATIONS, & <br />DETAILS <br />GRAND TOTAL: 9 <br />No. Revisions Date <br />pl <br />a <br />n <br /> <br />c <br />h <br />e <br />c <br />k <br /> <br />s <br />u <br />b <br />m <br />i <br />t <br />t <br />a <br />l