My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1044 W Fairbrook Ln & Unit #2 - Plan
PBA
>
Building
>
ProjectDox
>
F
>
Fairbrook Ln
>
1044 W Fairbrook Ln
>
1044 W Fairbrook Ln & Unit #2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/16/2026 5:00:21 AM
Creation date
4/16/2026 5:00:06 AM
Metadata
Fields
Template:
Plan
Permit Number
101125877
101125878
Full Address
1044 W Fairbrook Ln
1044 W Fairbrook Ln Unit# 2
Street Number
1044
Street Direction
W
Street Name
Fairbrook
Street Suffix
Ln
Unit Number
2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Entry /exit door must open over a landing not more than 1.5" <br />below thethreshold. Exception: Providing the door does not <br />swing over the landing. Landing shall be not more <br />than 7.75" below the threshold. Storm and screen doors are <br />permitted to swing over all exterior stairs and landings.(R311.3.1) <br />3' MIN LANDING TYPICAL ON ALL DOORS <br />KITCHEN <br />250 CFM HOOD <br />100 CFM EXHAUST FAN <br />DIRECT VENT TO OUTSIDE <br />WEATHER PROOF OUTLET <br />S <br /> OUTLET AFCI AND TAMPER RESISTANT <br />SWITCH <br />SMOKE DETECTOR, SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING <br />W.P. <br />SD <br />HARDWIRED LED LIGHT ( AFCI) <br />CM <br />100 CFM EXHAUST FAN <br />DIRECT VENT TO OUTSIDE MAX RATING 3.0 SONES. <br />a. Exhaust fans shall be ENERGY STAR compliant and be <br />ducted to terminate to the outside of the building. b. Exhaust <br />fans, not functioning as a component of a whole house <br />ventilation system, must be controlled by a humidistat which <br />shall be readily accessible. (9.506.1) <br />Bathrooms, water closet compartments <br />and other similar rooms shall be provided <br />natural ventilation <br />or with mechanical ventilation capable of <br />100 cfm exhausted directly to the outside <br />WHERE SUCH WIRING IS SERVED FROM A COMMERCIAL SOURCE AND SHALL BE EQUIPED <br />WITH A BATTERY BACKUP. WIRING IS SERVED FROM A COMMERCIAL SOURCE AND SHALL <br />BE EQUIPPED WITH A BATTERY BACK UP. SMOKE DETECTORS SHALL EMIT A SIGNAL WHEN <br />THE BATTERIES ARE LOW. WIRING SHALL BE PERMANENT AND WITHOUT A DISCONNECTING <br />SWITH OR OTHER THAN AS REQUIRED FOR OVERCURRENT PROTECTION. <br />CARBON MONOXIDE ALARMS, SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING <br />WHERE SUCH WIRING IS SERVED FROM A COMMERCIAL SOURCE AND SHALL BE EQUIPED <br />WITH A BATTERY BACKUP. WIRING IS SERVED FROM A COMMERCIAL SOURCE AND SHALL <br />BE EQUIPPED WITH A BATTERY BACK UP. <br /> WIRING SHALL BE PERMANENT AND WITHOUT A DISCONNECTING <br />SWITH OR OTHER THAN AS REQUIRED FOR OVERCURRENT PROTECTION. <br />CEILING FANS SHALL BE SUPPORTED <br />INDEPENDANTLY OF THE OUTLET BOX <br />OR BY LISTED OUTLET BOX INDENTIFIED <br />FOR THE USE (NOT A STANDARD MTL BOX) <br />422.18 2016 CEC <br />EXHAUST <br />FAN <br />STOVE EXHAUST FAN MAX 3.0 SONES RATING MIN 250 CFM, ENERGY STAR <br />WITH SMOOTH METAL DUCT TO TERMINATE OUTSIDE THE BUILDING <br />CEILING FAN <br />SHALL BE INTERCONNECTED <br />SHALL BE INTERCONNECTED <br /> Electric cooktop ready. (CEnergyC 150.0(u)) <br />a.A dedicated 240 volt branch circuit wiring shall be installed within 3 <br />feet from the cooktop and accessible to the cooktop with no obstructions. <br />The branch circuit conductors shall be rated at 50 amps minimum. The <br />blank cover shall be identified as "240V ready." All electrical components <br />shall be installed in accordance with the California Electrical Code. <br />b.The main electrical service panel shall have a reserved space to <br />allow for the installation of a double pole circuit breaker for a future <br />electric cooktop installation. The reserved space shall be permanently <br />marked as "For Future 240V use." <br />PROVIDE IAQV <br />37 CFM MIN AIR FLOW PER T-24 <br />USE ALWAYS ON BATHROOM EXHAUST <br />FAN TO MEET THIS REQUIREMENT <br />ALTERNATIVE: <br />All luminaires are required to be controlled by a National <br />Electrical Manufacturers Association (NEMA) SSL-7A-compliant <br />dimmer unless they are controlled by a vacancy sensor or an <br />occupancy sensor. The combined use of NEMA <br />SSL-7A-compliant dimmer with LED luminaires can ensure flicker <br />free operation when the luminaire is dimmed. Please show <br />dimmer switch(es) in the bedrooms on the plans. (2022 <br />Residential Compliance Manual 6.3.1(G)) <br />- New boxes used at luminaire or lampholder outlets in a ceiling <br />shall be required to support aluminaire weighing a minimum of <br />50lbs. Boxes used at luminaire outlets in walls shall be designed <br />for thepurpose and shall be marked on the interior indicating the <br />maximum weight of the luminaire permitted, ifother than 50lbs. <br />Outlet boxes or systems used as the sole support of ceiling fans <br />shall be listed and markedby the manufacturer as suitable for this <br />purpose. (314.27 CEC) <br />In bathrooms, at least one luminaire in each of these spaces must be <br />controlled by an occupant sensor or a vacancy sensor providing automatic-off <br />functionality. If an occupant sensor is installed, it must be initially configured to <br />manual-on operation using the manual control required under Section <br />150.0(k)2I. Please show sensor at the switch on the plans. <br />UL217 <br />UL2034/ 2075 <br />NEW WALLS - 2 X 4 STUDS @ 16" O.C. <br />WALL LEGEND <br />MAX RATING 3.0 SONES. GFI <br />W.P. <br />6 <br />2'-6" <br />2' <br />- <br />6 <br />" <br />HP W.H. <br />37 CFM <br />IAQV <br />7 <br />STACKABLE <br />WASHER AND <br />DRYER <br />BEDROOM <br /> HEIGHT: VAULTED <br />SCALE:1/4" =1'-0" <br />EXISTING PLAN WITH DEMO <br />(E) WALLS <br />200A METER SYSTEM. <br />PHOTO CELL <br />EGRESS WINDOWS FROM SLEEPING ROOM SHALL HAVE A NET CLEAR OPENING <br />OF 5.7 SQ. FT. NET CLEAR HEIGHT OR 24" & NET CLEAR WIDTH OF 20" AND A FINISHED <br />BEDROOM AND ROOMS USED FOR SLEEPING NOTES. <br />SILL HEIGHT OF NO MORE THAN 44" ABOVE FINISHED FLOOR. <br />BE TEMPERED AND LABELED A SUCH <br />3. ALL GLAZING WITH IN A DOOR AND WITH IN 24" OF A DOOR SHALL <br />3. ALL GLAZING WITH IN SHOWER ENCLOSURE AND TUB SHALL BE SAFETY <br />GLAZING PER CBC STANDARD 24-2 PART 1 <br />DOOR SCHEDULE <br />TYPE REMARKSQTYMAT.HEIGHT <br />1 STANDARD <br />SYM WIDTH <br />3'-0" <br />1. ALL DOORS AND WINDOWS TO BE APPROVED BY OWNER PRIOR TO INSTALLATION <br />2.THE LOAD RESISTANCE OF GLASS UNDER UNIFORM LOAD SHALL BE <br />DETERMINED IN ACCORDANCE WITH ASTM E 1300. <br />U-FACTOR SHGC <br />WINDOW SCHEDULE <br />TYPE REMARKSQTYHEIGHTSYMWIDTH <br />2.THE LOAD RESISTANCE OF GLASS UNDER UNIFORM LOAD SHALL BE <br />DETERMINED IN ACCORDANCE WITH ASTM E 1300. <br />U-FACTOR SHGC <br />N/A6'-8"SOLID CORE N/A <br />12 TEMP. GLZ. <br />2 STDR OR2'-8"2 6'-8" <br />1 <br />2'-0"2'-0" <br />N/A N/A <br />.3 .23SLIDING <br />POCKET <br />Door/window schedule - Safety or tempered glazing (CRC R308.4; CBC 2406.4): <br />a.Glazing in swinging, sliding and bi-fold doors. <br />b.Glazing in enclosures for or walls facing bathtubs and showers where the bottom exposed edge <br />is less than 60” measured vertically above a standing or walking surface and less than 60” <br />measured horizontally from the water’s edge of a shower or bathtub. <br />c.Glazing in an individual fixed or operable panel adjacent to a door shall be considered to be a <br />hazardous location where the bottom exposed edge of the glazing is less than 60 inches (1524 <br />mm) above the floor or walking surface and it meets either of the following conditions: <br />i. Where the glazing is within 24 inches (610 mm) of either side of the door in the plane of the door in a <br />closed position. <br />ii. Where the glazing is on a wall less than 180 degrees (3.14 rad) from the plane of the door in a closed <br />position and within 24 inches (610 mm) of the hinge side of an in-swinging door. <br />d. Safety glazing required to be permanently marked (etched) as required by CRC R308.1 <br />DOOR AND WINDOW NOTES <br />AC CONDENSER UNITS SUPPORTED FROM THE GROUND <br />SHALL REST ON A CONCRETE OR OTHER APPROVED BASE <br />EXTENDING NOT LESS THAN 3" ABOVE THE GROUND LEVEL. <br />ELECTRICAL DISCONNECT <br /> PER (CEC 430.102(B)) <br />Electric clothes dryer ready. Clothes dryer locations with gas or propane plumbing to serve <br />individual dwelling units shall include the following: (CEnergyC 150.0(v)) <br />a.A dedicated 240 volt branch circuit wiring shall be installed within 3 feet from the clothes <br />dryer location and accessible to the clothes dryer location with no obstructions. The branch <br />circuit conductors shall be rated at 30 amps minimum. The blank cover shall be identified as <br />"240V ready." All electrical components shall be installed in accordance with the California <br />Electrical Code. <br />b.The main electrical service panel shall have a reserved space to allow for the installation <br />of a double pole circuit breaker for a future electric clothes dryer installation. The reserved <br />space shall be permanently marked as "For Future 240V use." <br />FAN FOR RANGE <br />WITH SMOOTH METAL DUCT TO TERMINATE OUTSIDE THE BUILDING <br />250 CFM MINIMUN REQUIREMNETS <br />Provide 15" min. between the center of <br />water closet to any side wall. (Calif. <br />Plumb. Code 407.6) <br />Provide 24" clear space in front of any <br />water closet. (Calif. Plumb. Code 407.6) <br />Bathrooms, water closet compartments <br />and other similar rooms shall be provided <br />natural ventilation <br />or with mechanical ventilation capable of <br />50 cfm exhausted directly to the outside <br /> TUB OR SHOWER SHALL BE SAFETY <br />GLAZING PER CBC STANDARD 24-2 PART 1 <br />ALL GLAZING WITH IN <br />Entry /exit door must open over a landing not more than 1.5" <br />below thethreshold. Exception: Providing the door does not <br />swing over the landing. Landing shall be not more <br />than 7.75" below the threshold. Storm and screen doors are <br />permitted to swing over all exterior stairs and landings.(R311.3.1) <br />PROVIDE 3' MIN LANDING <br />Provide a smoke alarm and a carbon monoxide alarm or a combination of both <br />types outside of the Bedroom per CRC R314.3 and R315.3. Please note that <br />per CRC R314.3.3, smoke alarm shall be installed a minimum of 20 feet <br />horizontal distance from a permanently installed cooking appliance except that <br />photoelectric smoke alarm can be installed 10 feet or more from the cooking <br />appliance. The smoke alarm in the Living Room to be ionization or <br />photoelectric if it is less than 20 feet away from cooking appliance. [CRC <br />R314.3.3] <br />AT least one 120-volt, 20-ampere branch circuit shall be provided to supply a <br />bathroom receptacle outlet(s). Such circuits shall have no other outlets. [CEC <br />210.11] <br />AC OR MINI SPLIT <br />OR SIMILAR PER T-24 REQUIREMENTS <br />1 <br />2 <br />3 <br />4 <br />5 <br />Please note the laundry exhaust duct shall be 3' <br />away from openings into the building. [CMC 502.2.1] <br />PROVIDE EXHAUST DUCT 4" MIN. <br />IN DIA. W/ BACK-DRAFT DAMPER. <br />EXHAUST DUCT LIMITED TO 14' W/ 2 <br />PROVIDE 100 SQ.IN. OF MAKE UP AIR <br />TO LAUNDRY ROOM PER CMC 504.4 <br />PROVIDE TRANSFER GRILL. <br />provide one 20-amp dedicated branch circuits to supply the laundry <br />receptacle outlet(s). This circuit shall have no other outlets CEC art. <br />210.11(C)(2) <br />7 <br /> Exhaust fans, not functioning as a component of a whole house ventilation <br />system, must be controlled by a humidistat which shall be readily accessible. <br />(9.506.1) <br />Shower to encompass a 30" diameter circle. <br />Bathtub and shower floors, walls above bathtubs with a showerhead and <br />shower compartments shall be finished with a nonabsorbent surface extending <br />to a height of not less than 6 ft. above the floor. (R307.2) <br />MIN 1024 SQ.INCHES <br />8 <br />9 <br />10 <br />KEY NOTES <br />6 Heat pump water heater proposed per energy compliance documents <br />a. <br />A designate a space at least 2.5 feet by 2.5 feet wide and 7 feet tall suitable for the installation of <br />aheat pump water heater (HPWH). Heat pump water heaters require installation in locations <br />thatremain in the 40º–90ºF (4.4º–32.2ºC) range year-round and provide at least 1,000 cubic feet <br />(28.3cubic meters) of air space around the water heater. Energy compliance documents indicate <br />the heatpump water heater obtains required air from the inside of the ADU. This assumes the <br />Heat pump isinstalled inside the ADU. Please show on the plans. <br />b. <br />Provide a dedicated 125 volt, 20 amp electrical GFCI receptacle connected to the electrical <br />panelwith a 120/240 volt 3 conductor 10 AWG copper branch circuit, within 3 feet of the water <br />heater andaccessible to the water heater. (CEnergyC 150.0(n)(1)(A)) <br />c. <br />Indicate on the plans a condensate drain that is no more than 2 inches higher than the base of <br />theinstalled water heater, and allows natural draining without pump assistance is provided to the <br />heatpump water heater. <br />314'-0"4'-0"SLIDING <br />SHEET NUMBER <br />0002 <br />PER PLAN <br />BBCHECK BY <br />BRUNO B. <br />3/13/26DATE <br />DRAWN BY <br />JOB NUMBER <br />SCALE <br />A-2 <br />40 <br />7 <br />1 <br /> <br />C <br />O <br />L <br />U <br />M <br />B <br />I <br />A <br /> <br />A <br />V <br />E <br />, <br /> <br />95 <br />1 <br />. <br />2 <br />2 <br />4 <br />. <br />2 <br />5 <br />5 <br />6 <br />BD <br />R <br />A <br />F <br />T <br />I <br />N <br />G <br />N <br />D <br />E <br />S <br />I <br />G <br />N <br />@ <br />O <br />U <br />T <br />L <br />O <br />O <br />K <br />. <br />C <br />O <br />M <br />RI <br />V <br />E <br />R <br />S <br />I <br />D <br />E <br /> <br />C <br />A <br /> <br />9 <br />2 <br />5 <br />0 <br />1 <br />BR <br />U <br />N <br />O <br /> <br />B <br />U <br />S <br />T <br />O <br />S <br />BU <br />I <br />L <br />D <br />E <br />R <br />: <br />DR <br />E <br />C <br /> <br />C <br />O <br />N <br />S <br />T <br />R <br />U <br />C <br />T <br />I <br />O <br />N <br /> <br />S <br />E <br />R <br />V <br />I <br />C <br />E <br />S <br />AD <br />D <br />R <br />E <br />S <br />S <br />: <br />__ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />PH <br />O <br />N <br />E <br />: <br />95 <br />1 <br />- <br />7 <br />3 <br />3 <br />- <br />9 <br />7 <br />9 <br />0 <br />10 <br />4 <br />4 <br /> <br />F <br />A <br />I <br />R <br />B <br />R <br />O <br />O <br />K <br /> <br />L <br />N <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />9' <br />- <br />5 <br />" <br />9' <br />- <br />5 <br />" <br />8' <br />- <br />4 <br />" <br />5'-0" <br />10 <br />' <br />- <br />6 <br />" <br />11'-6" <br />3'-0" <br />3' <br />- <br />0 <br />" <br />5' <br />- <br />0 <br />" <br />2'-0" <br />1'-0" <br />NEW ADU 468 SQ.FT. <br />HOME ADDITION 31 SQ.FT. <br />20 <br />' <br />- <br />2 <br />" <br />23'-9" <br />3' <br />- <br />0 <br />" <br />10'-5" <br />SCALE:1/4" =1'-0" <br />NEW FLOOR PLAN <br />22 <br />' <br />- <br />1 <br />1 <br />" <br />29 <br />' <br />- <br />1 <br />0 <br />" <br />10'-6" <br />18'-2"10'-1" <br />32 <br />' <br />- <br />1 <br />0 <br />" <br />20 <br />' <br />- <br />2 <br />" <br />ELECTRICAL NOTES <br />ADU MEPS NOTES SEE A-5 <br />LIVING ROOM <br /> HEIGHT: VAULTED <br />KITCHEN <br />BEDROOM <br /> HEIGHT: 8'-0" <br />(E) <br />BEDROOM EXTENSION <br />BEDROOM <br /> HEIGHT: 8'-0" <br />(E) <br />BATHROOM <br /> HEIGHT: 8'-0" <br />(E) <br />LIVING ROOM <br /> HEIGHT: 8'-0" <br />(E) <br />2 CAR GARAGE <br /> HEIGHT: 8'-0" <br />(E) <br />(E) AC SYSTEM <br />4 <br />MINI SPLIT PER <br />T-24 REQUIREMENTSGFI <br />W.P. <br />SD <br />CM <br />SD <br />SD <br />SD <br />2 <br />2 <br />1 <br />1 <br />1 1 <br />.3 .23 <br />2 <br />3 <br />135'-0"2'-2".3 .23CASEMENT <br />GFI <br />GFI <br />GFI <br />GFI <br />GFI <br />GFI <br />GFI <br />GFI <br />GFI <br />W.P. <br />5 <br />1 <br />23'-9" <br />3'-5"4'-0"3'-5"4'-0" <br />SS <br />S SS <br />SS <br />SS <br />BEDROOM <br /> HEIGHT: 8'-0" <br />(E) <br />LIVING ROOM <br /> HEIGHT: 8'-0" <br />(E) <br />2 CAR GARAGE <br /> HEIGHT: 8'-0" <br />(E) <br />4' <br />- <br />0 <br />" <br />2' <br />- <br />8 <br />" <br />3'-2" <br />DIMMER <br />DIMMER <br />NEW 100 AMP MIN <br />SUBPANEL FOR ADU <br />GFI <br />AD <br />U <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />__ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />10 <br />4 <br />4 <br /> <br />F <br />A <br />I <br />R <br />B <br />R <br />O <br />O <br />K <br /> <br />L <br />N <br /> <br />U <br />N <br />I <br />T <br /> <br /># <br />2 <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />BATHROOM <br />BEDROOM <br /> HEIGHT: 8'-0" <br />(E) <br />KICHEN <br /> HEIGHT: 8'-0" <br />(E) <br />DINING <br /> HEIGHT: 8'-0" <br />(E) <br />LAUNDRY <br /> HEIGHT: 8'-0" <br />(E) <br />WATER HEATER <br />(E) <br />WATER HEATER <br />(E) <br />N <br />N <br />within an enclosure that <br />architecturally matches <br />the exterior <br />TYPICAL LANDING DETAIL <br />36" MIN LANDING <br />1" <br /> <br />M <br />I <br />N <br />1 <br />1 <br />10 <br />" <br />10 <br />" <br /> <br />LANDING STEP MIN REQ. <br />a.7.75" rise & min. 10" run. (R311.7.4) <br />b.Min. (36") clear width. (R311.7.1) <br /> <br />4" CONC. SLAB <br />ADU WALL <br /> <br />(2) #4 T AND B <br />TYP. <br />RHEEM HPLD40-1RH <br />3'-0" <br />CASEMENT EGRESS WINDOW2 <br />2 <br />A-2 <br /> <br />#4 DOWELS AT 24" O.C. <br />SD <br />CM <br />SD <br />CM <br />Smoke Alarms: Addition to smoke alarm(s) in each sleeping room; <br />provide smoke alarm in the immediate vicinity of the bedroom(s) in <br />accordance with following provisions. (R314) <br />- Not less than 3 feet horizontally from the door or opening of a bathroom <br />that contains a bathtub or shower unless this would prevent placement of <br />a smoke alarm required by this section. <br />- Smoke alarms or smoke detectors shall be installed a minimum of 20 <br />feet horizontal distance from a permanently installed cooking appliance. <br />Exception: Ionization smoke alarms with an alarm-silencing switch or <br />Photoelectric smoke alarms shall be permitted to be installed 10 feet or <br />greater from a permanently installed cooking appliance. <br />Photoelectric smoke alarms shall be permitted to be installed greater than <br />6 feet from a permanently installed cooking appliance where the kitchen <br />or cooking area and adjacent spaces have no clear interior partitions and <br />the 10 ft distances would prohibit the placement of a smoke alarm or <br />smoke detector required by other sections of the code. Smoke alarms <br />listed for use in close proximity to a permanently installed cooking <br />appliance. <br />- Smoke alarms and smoke detectors shall not be installed within a 36 in. <br />horizontal path from the supply registers of a forced air heating or cooling <br />system and shall be installed outside of the direct airflow from those <br />registers. <br />- Smoke alarms and smoke detectors shall not be installed within a 36 in. <br />horizontal path from the tip of the blade of a ceiling-suspended (paddle) <br />fan. <br />Comment <br /> <br />2% MIN DRAINAGE AWAY <br />24 <br />" <br />MI <br />N