2710 W Edinger Ave #A - Plan
PBA
>
Building
>
ProjectDox
>
E
>
Edinger Ave
>
2710 W Edinger Ave Unit# A
>
2710 W Edinger Ave #A - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2026 5:00:12 AM
Creation date
4/17/2026 5:00:06 AM
Metadata
Fields
Template:
Plan
Permit Number
20187697
30149782
40141159
101126159
Full Address
2710 W Edinger Ave Unit# A
Street Number
2710
Street Direction
W
Street Name
Edinger
Street Suffix
Ave
Unit Number
A
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
(E) RESTROOM <br />(E) MECH. RM <br />50x2 <br />50x2 <br />CM <br />T1200 <br />T300 <br />T300 <br />T600 <br />T600 <br />T400 <br />T400 <br />T1200 <br />T300 <br />T300 <br />T600 <br />T600 <br />T400 <br />T400 <br />T1200 <br />T300 <br />T300 <br />T600 <br />T600 <br />T400 <br />T400 <br />T600 <br />T600 <br />T400 <br />T400 <br />(E) LAUNDRY AREA <br />30x2 <br />CM <br />(E) COUNTER <br />(E) COUNTER <br />(E) SINK <br />SWITCHBOARD / <br />METER UPGRADE <br />(N) PANEL <br />UPGRADE <br />VI <br />F <br />69 <br />' <br /> <br />- <br /> <br />2 <br />" <br />45 <br />' <br /> <br />- <br /> <br />4 <br />" <br />9' <br /> <br />- <br /> <br />2 <br />" <br />14 <br />' <br /> <br />- <br /> <br />8 <br />" <br />29 <br />' <br /> <br />- <br /> <br />0 <br />" <br />VI <br />F <br /> <br />A <br />L <br />L <br /> <br />( <br />E <br />) <br /> <br />D <br />I <br />M <br />E <br />N <br />S <br />I <br />O <br />N <br />S <br />, <br /> <br />T <br />Y <br />P <br />. <br />32 <br />' <br /> <br />- <br /> <br />1 <br />0 <br />" <br />VI <br />F <br />7' <br /> <br />- <br /> <br />4 <br />" <br />VIF <br />19' - 1 7/8" <br />9' - 8 1/2"3' - 11 1/2" <br />9' - 3 1/2"4' - 4 3/8" <br />VIF <br />5' - 6" <br />(E) ACCESS <br />DOOR <br />30x2 <br />30x2 <br />30x2 <br />30x2 <br />30x2 <br />30x2 <br />30x2 <br />30x2 <br />30x2 <br />30x2 <br />30x2 <br />ME <br />C <br />H <br />. <br /> <br />C <br />H <br />A <br />S <br />E <br />(E) COMMON AREA <br />(E) HALL <br />INSTALL (N) GRAB BAR, <br />SEE /B1 A100 <br />ACCESSIBLE <br />WASHER PER <br />11B-611 <br />ACCESSIBLE <br />DRYER PER <br />11B-611 <br />(E) LAUNDRY AREA <br />(E) RESTROOM <br />(E) MECH. RM <br />(E) COMMON AREA <br />OPEN TO STRUCT. ABOVE <br />OP <br />E <br />N <br /> <br />T <br />O <br /> <br />S <br />T <br />R <br />U <br />C <br />T <br />. <br /> <br />A <br />B <br />O <br />V <br />E <br />REPLACE (E) DAMAGED CLG GRID <br />& CEILING TILE AS NEEDED <br />REPLACE ALL (E) LIGHT, <br />SEE ELECTRICAL, TYP. <br />REPLACE (E) <br />DAMAGED FAN <br />REPLACE ALL (E) LIGHT, <br />SEE ELECTRICAL, TYP. <br />REPLACE (E) DAMAGED <br />CLG GRID & CEILING TILE <br />AS NEEDED <br />REPLACE ALL (E) LIGHT, <br />SEE ELECTRICAL, TYP. <br />ME <br />C <br />H <br />. <br /> <br />C <br />H <br />A <br />S <br />E <br />ACT-1 CEILING <br />10' - 0" A.F.F. <br />GWB CLG <br />8' - 0" A.F.F. <br />AD <br />J <br />A <br />C <br />E <br />N <br />T <br /> <br />T <br />E <br />N <br />A <br />N <br />T <br />AD <br />J <br />A <br />C <br />E <br />N <br />T <br /> <br />T <br />E <br />N <br />A <br />N <br />T <br />SUSPENDED LIGHT FIXTURE <br />(N) SWITCH GEAR <br />& METER PER SCE <br />A100 <br />D1 <br />TYP <br />12 GA HANGER WIRE <br />MAIN RUNNER <br />(REF. ESR-1308) <br />ACOUSTIC CEILING TILE <br />LEDGERS/CLIPS <br />(REF. ESR-1308) <br />8" MAX. <br />#8 SMS <br />SLOTTED 1" X 1" <br />ANGLE SPACER, <br />20 GA <br />3/4" MIN. CLEAR <br />HANGER / SPLAY WIRE <br />MA <br />X <br />3" <br />1/4" DIA x 4" SCREW EYE <br />W/ FULL THREAD W. MIN. <br />1-1/4" EMBED, TYP. <br />12 GA HANGER WIRE <br />WOOD FRAME, <br />PROVIDE BLOCKING <br />AS NEEDED, TYP. <br />WOOD SHEATHING 1. <br />a. <br />b. <br />c. <br />d. <br />1. <br />a. <br />b. <br />c. <br />d. <br />e. <br />f. <br />g. <br />1. <br />a. <br />b. <br />c. <br />Ceiling suspension system components: <br />Suspension system components shall comply W/ ASTM C635 and Section 5.1 of <br />ASTM E580. <br />Only heavy-duty main tees as defined by ASTM C635 shall be used as main <br />runners. A heavy-duty runner shall be adequate to support 16 PLF of uniformly <br />distributed load over a 4 feet long simply supported span without the mid-span <br />deflection exceeding 0.133 inch. <br />Suspension wires shall be minimum No.12 gauge, soft annealed, and galvanized <br />mild steel wires. <br />Main runners, cross runners and their splices, intersection connectors, and <br />expansion devices shall be designed to carry a mean ultimate test load of not less <br />than 180 lbs in compression and tension (ASTM E580 Section 5.1.2). <br />Ceiling suspension system installation: <br />The suspension system shall be installed in compliance with ASTM C636 and <br />Section 5.2 of ASTM E580. <br />To support dead load and live load of a ceiling suspension system, No.12 gauge <br />hanger wire shall be spaced at 4 feet on center and shall be attached to main <br />runners unless calculations justifying the increased spacing are approved by plan <br />check engineer. <br />Provide No.12 gauge hanger wires at the ends of each main and cross runners <br />within 8 inches of the support. <br />The width of the perimeter supporting closure angle shall be not less than 2 inches. <br />Exception: supporting closure angle narrower than 2” may be used if the assembly of <br />a closure angle and a wall attachment clip is approved by ICC equivalent to 2-inch- <br />wide perimeter supporting angle required by Section 5.2.2 of ASTM E580 for <br />Seismic Design Categories D, E and F. <br />Main runner and cross runner ends shall be attached to the perimeter on two <br />adjacent walls. A clearance of ¾ inch shall be maintained between the main runner <br />and cross runner ends and the perimeter members on the two opposite walls. On <br />other walls where terminal end runners are not fixed to the perimeter supporting <br />closure, allow for ¾ inch movement. <br />The terminal ends of main runners and cross runners not attached to the perimeter <br />closure angle or channel shall be prevented from spreading. A metal spreader strut <br />or a No.16 gauge wire with a positive mechanical connection to the runner may be <br />used for this purpose. <br />Attachment requirements of hanger wires and bracing wires <br />Separate all ceiling hanger wires and bracing wires at least 6 inches from all un- <br />braced ducts, pipes, conduit, etc. <br />Hanger wires shall not hang more than 1:6 out of plumb unless counter-sloping wires <br />are provided. <br />The wire loops of hanger wires shall be tightly wrapped and sharply bent to prevent <br />any vertical movement or rotation of the member within the loops. The wire must be <br />wrapped around itself a minimum of three full turns within 3-inch length. <br />FIXTURE BRACING DETAIL <br />12" MAX 42" MIN <br />54" MIN <br />17 <br />" <br /> <br />- <br /> <br />1 <br />9 <br />" <br />7" - 9" <br />24" MIN 12" MIN <br />36" MIN <br />33 <br />" <br /> <br />- <br /> <br />3 <br />6 <br />" <br />33 <br />" <br /> <br />- <br /> <br />3 <br />6 <br />" <br />33 <br />" <br /> <br />- <br /> <br />3 <br />6 <br />" <br />GRAB BAR <br />SIDE WALL GRAB BAR AT WATER CLOSET <br />CL <br />CL <br />REAR WALL GRAB BAR AT WATER CLOSET <br />17 <br />" <br /> <br />- <br /> <br />1 <br />9 <br />" <br />A B <br />GRAB BAR <br />18 <br />" <br /> <br />m <br />i <br />n <br />. <br />TOILET ACCESSORIES <br />ZONE OF POSSIBLE <br />LOCATION <br />3' <br />- <br />4 <br />" <br /> <br />M <br />A <br />X <br />. <br />Height of <br />Laundry Compartment Opening <br />(a) <br />top loading (b) <br />front loading <br />91 <br />5 <br />36 <br /> <br />m <br />a <br />x <br />38 <br />0 <br /> <br />- <br /> <br />9 <br />1 <br />5 <br />15 <br /> <br />t <br />o <br /> <br />3 <br />6 <br />05/31/2027 <br />AS NOTED <br />DRAWN CHECKEDDATE <br />SCALE <br />PROJECT NUMBER <br />SHEETSHEET NAME <br />PROJECT TITLE <br />LOCATION: <br />1 2 3 4 5 <br />B <br />A <br />C <br />D <br />15551 Eden Street <br />Westminster, CA 92683 <br />Copyright. Hu Architecture Inc. 2018. All rights reserved. <br />This drawing and its contents is copyright by Hu Architecture. <br />Reproducing, modifying, and distributing this material without the <br />written permission of Hu Architecture is prohibited.ST <br />A <br />M <br />P <br />CLIENT INFORMATION <br />duchuy@huarchitecture.com <br />(714) 476-4751 <br />NO.DATE DESCRIPTION <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />S <br />CONSULTANT INFORMATION <br />B <br />A <br />C <br />D <br />duchuy@huarchitecture.com <br />(714) 476-47513/20/2026 3:50:32 PM <br />A100 <br />DHHDWGIssue Date <br />2025.103 <br />PLANS & DETAILS <br />Laundromat 2710 W Edinger Ave, Suite A | Electrical, Lighting & Repair Ceiling <br />Laundromat 2710 W Edinger Ave, Suite A <br />Santa Ana, CA 92704 <br />Thai H. Dinh <br />714.468.3129 | khadoan84@yahoo.com <br />Laundromat 2710 W Edinger Ave, Suite A <br />Santa Ana, CA 92704 <br />20 <br />2 <br />5 <br />. <br />1 <br />0 <br />3 <br />_ <br /> <br />L <br />a <br />u <br />n <br />d <br />r <br />o <br />m <br />a <br />t <br /> <br />2 <br />7 <br />1 <br />0 <br /> <br />W <br /> <br />E <br />d <br />i <br />n <br />g <br />e <br />r <br /> <br />A <br />v <br />e <br />, <br /> <br />S <br />u <br />i <br />t <br />e <br /> <br />A <br /> <br />| <br /> <br />E <br />l <br />e <br />c <br />t <br />r <br />i <br />c <br />a <br />l <br />, <br /> <br />Li <br />g <br />h <br />t <br />i <br />n <br />g <br /> <br />& <br /> <br />R <br />e <br />p <br />a <br />i <br />r <br /> <br />C <br />e <br />i <br />l <br />i <br />n <br />g <br />NOT TO SCALEB1 <br />GRAB BAR, ACCESSIBLE WATER CLOSET AND <br />DISPENSER <br />SCALE: 1/4" = 1'-0" <br />ARCHITECTURAL CEILING PLAN <br />SCALE: 1/4" = 1'-0" <br />ARCHITECTURAL FLOOR PLAN <br />EQUIPMENT SCHEDULE <br />Mark Type Manufacturer Model Comments <br />30x2 30x2 DEXTER 30x2 <br />50x2 50x2 DEXTER 50x2 <br />CM CASH COIN MACHINE STANDAR <br />CHANGE MAKERS <br />MC520RL-DA <br />T300 T300 DEXTER T300 <br />T400 T400 DEXTER T400 <br />T600 T600 DEXTER T600 <br />T1200 T1200 DEXTER T1200 <br />SCALE: 3" = 1'-0"D1 SUSP ACT CLG - SLIP JOINT @ WALL <br />NO DATE DESCRIPTION <br />SCALE: 3/8" = 1'-0"A1 LAUNDRY ACCESS