PART I - GENERAL <br />1.01 GENERAL PROJECT REQUIREMENTS <br />A. ALL DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, <br />INCLUDING DIVISION 1 SPECIFICATION SECTIONS AND GENERAL <br />AND SUPPLEMENTARY CONDITIONS, SHALL APPLY TO THIS <br />SECTION. <br />B. RELATED DOCUMENTS: ARCHITECTURAL SPECIFICATIONS, <br />LIGHTING FIXTURE SPECIFICATIONS INCLUDED IN OTHERS' <br />DOCUMENTS, GENERAL, SPECIAL AND SUPPLEMENTARY <br />CONDITIONS, AND SIMILAR DOCUMENTS SHALL FORM A PART OF <br />THESE SPECIFICATIONS. <br />C. SCOPE OF WORK: PROVIDE ALL REQUIRED LABOR, MATERIALS, <br />EQUIPMENT AND CONTRACTOR'S SERVICES NECESSARY FOR <br />COMPLETE AND SAFE INSTALLATION OF ELECTRICAL WORK IN <br />CONFORMITY WITH REQUIREMENTS OF ALL AUTHORITIES HAVING <br />JURISDICTION, AS INDICATED ON DRAWINGS AND/OR DESCRIBED <br />IN THESE SPECIFICATIONS. <br />D. SITE CLEANLINESS: KEEP SITE FREE FROM SURPLUS <br />MATERIAL, TOOLS, AND RUBBISH AT ALL TIMES DURING <br />CONSTRUCTION PERIOD AND, UPON COMPLETION, LEAVE SITE IN <br />CLEAN CONDITION. <br />E. DAMAGE: REPAIR ANY DAMAGE CAUSED TO WORK OF OTHER <br />TRADES AND ANY OTHER DAMAGE CAUSED BY THIS SECTION TO <br />INTENDED/ORIGINAL CONDITION. <br />F. PASSAGE OF EQUIPMENT: CHECK THE DIMENSIONS OF <br />EQUIPMENT OF THIS SECTION TO ENSURE THAT SUCH <br />EQUIPMENT CAN PASS THROUGH THE NECESSARY AREAS TO <br />REACH ITS ULTIMATE INSTALLED LOCATION. INCLUDE IN BID <br />COSTS FOR ALL WORK REQUIRED, INCLUDING ANY WORK <br />REQUIRED TO MOVE THE EQUIPMENT THROUGH THE SITE TO <br />THIS FINAL LOCATION AND ANY DISMANTLING/RE-ASSEMBLY. <br />G. GUARANTEE: CONTRACTOR SHALL GUARANTEE THAT ALL <br />PORTIONS OF THE WORK ARE IN ACCORDANCE WITH CONTRACT <br />REQUIREMENTS. GUARANTEE ALL WORK AGAINST FAULTY AND <br />IMPROPER MATERIAL AND WORKMANSHIP FOR A MINIMUM <br />PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE BY <br />OWNER. IF GUARANTEES OR WARRANTIES FOR LONGER TERMS <br />ARE SPECIFIED BY CONTRACT, SUCH LONGER TERM SHALL <br />APPLY. <br />H. PERMITS AND INSPECTIONS: CONTRACTOR SHALL SECURE ALL <br />APPROVALS AND PAY ALL FEES FOR WORK INSTALLED AND <br />DELIVER CERTIFICATE TO OWNER. INCLUDE ALL COSTS IN BASE <br />BID. <br />I. PRIOR TO SUBMITTING BID, CONTRACTOR SHALL VERIFY <br />ALLOWABLE WORKING HOURS, EMPLOYEE PARKING AREAS, <br />MATERIAL DELIVERY AND STORAGE REQUIREMENTS, AND <br />REQUIREMENTS FOR DEMOLITION AND REMOVAL OF <br />CONSTRUCTION DEBRIS (IF ANY). INCLUDE ALL COSTS IN BID FOR <br />DUST BARRIERS AND DUMPSTERS FOR THE DURATION OF THE <br />PROJECT AS REQUIRED. <br />J. DURING PREPARATION OF BID, CONTRACTOR MAY DISCOVER <br />ERRORS IN THESE DOCUMENTS OR DISCREPANCIES BETWEEN <br />THESE DOCUMENTS AND THOSE OF OTHER TRADES. IN CASE OF <br />DISCREPANCIES, CONTRACTOR IS RESPONSIBLE FOR BIDDING <br />THE GREATER QUANTITY OR HIGHER QUALITY ITEMS IF NO <br />SUFFICIENT RESOLUTION OF THE DISCREPANCY IS DETERMINED <br />PRIOR TO SUBMITTING BID. <br />K. RECORD DRAWINGS: UPON PROJECT COMPLETION, DELIVER <br />TO OWNER ONE SET OF REPRODUCIBLE DRAWINGS AND ONE <br />BOUND SET OF BLUEPRINTS AND PANEL SCHEDULES SHOWING <br />ALL WORK AS ACTUALLY INSTALLED. <br />1.02 DEFINITIONS AND TERMINOLOGY <br />A. DRAWINGS AND SPECIFICATIONS ARE OF SIMPLIFIED FORM <br />AND INCLUDE INCOMPLETE SENTENCES. WORDS OR PHRASES <br />SUCH AS "THE CONTRACTOR SHALL", "SHALL BE", "FURNISH", <br />"PROVIDE", "A", "AN", "THE" AND "ALL" MAY BE OMITTED FOR <br />BREVITY. <br />B. WORDS AND/OR PHRASES USED IN THESE DOCUMENTS ARE <br />DEFINED AS FOLLOWS: <br />1. "FURNISH" OR "PROVIDE": TO SUPPLY, INSTALL, AND <br />CONNECT COMPLETELY AND READY FOR SAFE AND <br />REGULAR OPERATION OF PARTICULAR WORK REFERRED <br />TO UNLESS SPECIFICALLY NOTED OTHERWISE. <br />2. "INSTALL": TO ERECT, MOUNT, AND CONNECT COMPLETE <br />WITH ANY NECESSARY RELATED ACCESSORIES (WHETHER <br />SPECIFICALLY INDICATED OR NOT). <br />3. "SUPPLY": TO PURCHASE, PROCURE, ACQUIRE, AND <br />DELIVER COMPLETE WITH ANY NECESSARY RELATED <br />ACCESSORIES. <br />4. "WORK": LABOR, MATERIALS, EQUIPMENT, AND <br />ACCESSORIES,AND OTHER ITEMS REQUIRED FOR PROPER <br />AND COMPLETE INSTALLATION. <br />5. "CONTRACTOR": ELECTRICAL CONTRACTOR, UNLESS <br />NOTED OTHERWISE. <br />6. "PROJECT MANAGER": THE ENTITY/PROFESSIONAL <br />RESPONSIBLE FOR COORDINATION AND COMPLETION OF <br />ALL REQUIRED CONSTRUCTION WORK FOR THIS PROJECT <br />(THE GENERAL CONTRACTOR OR ARCHITECT OR OTHER <br />AUTHORITY AS DESCRIBED IN THE CONTRACT). <br />7. "OWNER": THE OWNER OR TENANT THAT IS THE ULTIMATE <br />RECIPIENT OF THE CONSTRUCTION WORK PERFORMED. <br />8. "WIRING": RACEWAY, FITTINGS, CONDUCTORS, BOXES, <br />AND RELATED ITEMS. <br />9. "CONCEALED": INSTALLED EMBEDDED IN MASONRY OR <br />OTHER CONSTRUCTION, IN FURRED SPACES, WITHIN <br />DOUBLE PARTITIONS OR HUNG CEILINGS, IN TRENCHES, IN <br />CRAWL SPACES, IN ENCLOSURES, OR AS DEFINED IN NEC <br />ARTICLE 100. <br />10."EXPOSED": NOT INSTALLED UNDERGROUND OR <br />"CONCEALED" AS DEFINED ABOVE, OR AS DEFINED IN NEC <br />ARTICLE 100. <br />11."EQUAL": ACCEPTABLE EQUIVALENT IN MATERIALS, <br />WEIGHT, SIZE, DESIGN, OPERATION, AND EFFICIENCY OF <br />SPECIFIED PRODUCT. FINAL DETERMINATION OF <br />ACCEPTABLE EQUIVALENCY SHALL BE MADE BY ENGINEER <br />WHEN AN ITEM IS INDICATED AS "APPROVED EQUAL". <br />C. WHERE TERMS ARE NOT DEFINED IN THESE DOCUMENTS, THE <br />DEFINITIONS IN NEC ARTICLE 100 SHALL TAKE PRECEDENCE. <br />1.03 REFERENCE STANDARDS <br />A. COMPLY WITH ALL PUBLISHED CODES, SPECIFICATIONS, <br />STANDARDS, TESTS, OR RECOMMENDED METHODS OF TRADE, <br />INDUSTRY OR GOVERNMENTAL ORGANIZATIONS, OR LOCAL <br />UTILITIES AS THEY APPLY TO WORK IN THIS DIVISION AS <br />OUTLINED BELOW: <br />1. ADA - AMERICANS WITH DISABILITIES ACT. <br />2. ANSI - AMERICAN NATIONAL STANDARDS INSTITUTE. <br />3. ASTM - AMERICAN SOCIETY OF TESTING AND MATERIALS. <br />4. CBM - CERTIFIED BALLAST MANUFACTURERS. <br />5. ETL - ELECTRICAL TESTING LABORATORIES. <br />6. FAA - FEDERAL AVIATION ADMINISTRATION <br />7. FCC - FEDERAL COMMUNICATIONS COMMISSION. <br />8. FM - FACTORY MUTUAL. <br />9. IEEE - INSTITUTE OF ELECTRICAL AND ELECTRONICS <br />ENGINEERS. <br />10.IES - ILLUMINATING ENGINEERING SOCIETY. <br />11.NEC - NATIONAL ELECTRICAL CODE. <br />12.NECA - NATIONAL ELECTRICAL CONTRACTOR'S <br />ASSOCIATION. <br />13.NEMA - NATIONAL ELECTRICAL MANUFACTURER'S <br />ASSOCIATION. <br />14.NFPA - NATIONAL FIRE PROTECTION ASSOCIATION. <br />15.OSHA - OCCUPATIONAL SAFETY AND HEALTH ACT. <br />16.UL - UNDERWRITERS' LABORATORIES, INC. <br />17.LOCALLY ADOPTED BUILDING CODES AND/OR OTHER <br />BUILDING CODES SPECIFIC TO THIS JURISDICTION. <br />18.LOCALLY ADOPTED ELECTRICAL CODES AND/OR OTHER <br />ELECTRICAL CODES SPECIFIC TO THIS JURISDICTION. <br />19.LOCAL UTILITY AUTHORITIES. <br />20.LOCAL FIRE DEPARTMENT. <br />B. COMPLIANCE WITH GOVERNING CODES AND REGULATIONS <br />SHALL BE SUBJECT TO THE FOLLOWING GUIDELINES: <br />1. DRAWINGS AND SPECIFICATION REQUIREMENTS SHALL <br />GOVERN WHERE THEY EXCEED GOVERNING CODE AND <br />REGULATION REQUIREMENTS. <br />2. WHERE REQUIREMENTS BETWEEN GOVERNING CODES <br />AND REGULATIONS VARY, THE MORE STRINGENT SHALL <br />APPLY. <br />3. NOTHING CONTAINED IN CONTRACT DOCUMENTS SHALL <br />BE CONSTRUED AS AUTHORITY OR PERMISSION TO <br />DISREGARD OR VIOLATE LEGAL REQUIREMENTS. <br />CONTRACTOR SHALL IMMEDIATELY DRAW THE ATTENTION <br />OF THE PROJECT MANAGER TO ANY SUCH CONFLICTS <br />NOTED IN THE CONTRACT DOCUMENTS. <br />1.04 SUBMITTALS <br />A. PROVIDE ELECTRONIC COPIES OF SUBMITTALS WITH <br />DESCRIPTIVE DATA FOR ALL PRODUCTS AND MATERIALS FOR <br />REVIEW BY ENGINEER PRIOR TO ORDERING. SUBMITTALS SHALL <br />CLEARLY IDENTIFY MANUFACTURER, MODEL NUMBER, AND ANY <br />DETAILS NECESSARY TO SHOW COMPLIANCE WITH THE <br />SPECIFICATION DOCUMENTS IN ADDITION TO THOSE <br />PARAMETERS OUTLINED BELOW FOR THE FOLLOWING ITEMS: <br />1. LIGHTING FIXTURES: INCLUDING PHOTOMETRIC <br />PERFORMANCE DATA AND ANALYSIS (WITH PARAMETERS <br />OUTLINED) AS REQUIRED BY ENGINEER, FIXTURE POLES <br />AND MOUNTING ARMS, BALLASTS, AND LAMPS. <br />2. DEVICES AND EQUIPMENT: INCLUDING WALL SWITCHES, <br />WALL-BOX DIMMERS, RECEPTACLES, DEVICE COVER <br />PLATES, SAFETY SWITCHES, ETC. <br />3. OVERCURRENT DEVICES: INCLUDING TIME/CURRENT <br />CURVES IF REQUESTED. <br />4. SWITCHBOARDS, DISTRIBUTION BOARDS, MOTOR <br />CONTROL CENTERS, AND PANELBOARDS: DIMENSIONS, <br />ENCLOSURE DATA, VOLTAGE AND PHASE, AMPACITY, <br />OVERCURRENT DEVICES (INCLUDING QUANTITIES, <br />AMPACITY RATINGS, TYPES, POLES, ETC.), CATALOG CUTS, <br />AND ANY RELATED ACCESSORIES. <br />5. TRANSFORMERS: WEIGHT OF TRANSFORMER, MOUNTING <br />DETAILS, AND PERFORMANCE DATA (INCLUDING <br />IMPEDANCE, EFFICIENCY, AND SOUND LEVEL) <br />6. SPECIAL SYSTEMS AND EQUIPMENT: <br />ARCHITECTURAL/THEATRICAL DIMMING EQUIPMENT AND <br />CONTROLS, OCCUPANCY AND DAYLIGHT HARVESTING <br />SENSORS, EMERGENCY POWER SOURCES AND RELATED <br />TRANSFER EQUIPMENT, TRANSIENT VOLTAGE SURGE <br />SUPPRESSORS, SUB-METERING DEVICES, ETC. <br />B. SHOP DRAWINGS: COORDINATED LAYOUT PLANS FOR <br />ELECTRICAL ROOMS, INFORMATION TECHNOLOGY ROOMS, AND <br />OTHER SPECIALIZED AREAS AS REQUESTED BY THE ENGINEER, <br />SHOWING WORK OF ALL TRADES INCLUDING BUT NOT LIMITED TO <br />DUCTWORK, HVAC, PLUMBING, FIRE PROTECTION PIPING, <br />ELECTRICAL CONDUITS, BUS DUCTS, AND ALL RELATED <br />EQUIPMENT. <br />1.05 SUBSTITUTIONS <br />A. PROCEDURE: CONTRACTOR'S BID SHALL INCLUDE PRODUCTS <br />AS OUTLINED IN THE SPECIFICATION DOCUMENTS. EXCEPT IN <br />THE CASE OF PRODUCT UNAVAILABILITY, SUBSTITUTIONS WILL <br />NOT BE ALLOWED. ENGINEER WILL CONSIDER FORMAL <br />REQUESTS FOR SUBSTITUTION OF PRODUCTS ONLY IF THE <br />REQUEST MEETS THE FOLLOWING CONDITIONS:. <br />1. WRITTEN EVIDENCE OF PRODUCT UNAVAILABILITY <br />NECESSITATING THE PROPOSED SUBSTATION FROM THE <br />SPECIFIED PRODUCT'S MANUFACTURER REPRESENTATIVE <br />OR SUPPLIER. <br />2. COMPLETE DATA SUBSTANTIATING COMPLIANCE OF <br />PROPOSED SUBSTITUTION WITH REQUIREMENTS AND <br />SPECIFICATIONS STATED IN CONTRACT DOCUMENTS. <br />3. DATA RELATING TO CHANGES IN CONSTRUCTION <br />SCHEDULE. <br />4. COMPLETE DESCRIPTION OF ANY EFFECT OF <br />SUBSTITUTION ON OTHER WORK IN THIS AND OTHER <br />TRADES. <br />B. FAILURE TO PLACE ORDERS FOR SPECIFIED ITEMS IN A TIMELY <br />MANNER (WITH RESPECT TO THE PROJECT MANAGER'S <br />CONSTRUCTION SCHEDULE) DOES NOT CONSTITUTE PRODUCT <br />UNAVAILABILITY. <br />C. CONTRACTOR SHALL BE RESPONSIBLE AT NO EXTRA COST TO <br />OWNER FOR ANY CHANGES RESULTING FROM PROPOSED <br />SUBSTITUTIONS WHICH AFFECT WORK OF OTHER TRADES OR <br />RELATED CONTRACTS. <br />D. CLAIMS FOR ADDITIONAL COSTS CAUSED BY SUBSTITUTION <br />WHICH MAY SUBSEQUENTLY BECOME APPARENT SHALL BE MET <br />BY THE CONTRACTOR. <br />E. SUBSTITUTIONS WILL NOT BE CONSIDERED FOR ACCEPTANCE <br />WHEN ACCEPTANCE WILL REQUIRE SUBSTANTIAL REVISION OF <br />CONTRACT DOCUMENTS, UNLESS CONTRACTOR BEARS COST OF <br />REDESIGN. <br />F. SUBSTITUTE PRODUCTS SHALL NOT BE ORDERED OR <br />INSTALLED WITHOUT PRIOR WRITTEN APPROVAL/ACCEPTANCE <br />BY ENGINEER. <br />1.06 PRODUCT DELIVERY, STORAGE, AND HANDLING <br />A. SHIP EQUIPMENT IN ORIGINAL PACKAGES TO PREVENT <br />DAMAGE OR ENTRANCE OF FOREIGN MATTER. HANDLE AND SHIP <br />IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. <br />B. PROVIDE AND MAINTAIN PROTECTIVE COVERINGS DURING <br />CONSTRUCTION. <br />C. REPLACE, AT NO EXPENSE TO OWNER, EQUIPMENT OR <br />MATERIAL DAMAGED, LOST, OR STOLEN DURING STORAGE OR <br />HANDLING AS DIRECTED BY THE PROJECT MANAGER. <br />1.07 EXISTING CONDITIONS (AS APPLICABLE) <br />A. VERIFICATION: BEFORE SUBMITTING BID, BECOME <br />THOROUGHLY FAMILIAR WITH ACTUAL EXISTING CONDITIONS <br />AND THE PRESENT INSTALLATIONS TO WHICH CONNECTIONS <br />MUST BE MADE OR WHICH MUST BE ALTERED. THE INTENT OF <br />THE WORK IS SHOWN ON THE DRAWINGS AND DESCRIBED <br />HEREIN, AND NO CONSIDERATION WILL BE GRANTED BY REASON <br />OF LACK OF FAMILIARITY ON THE PART OF THE CONTRACTOR <br />WITH ACTUAL PHYSICAL CONDITIONS, REQUIREMENTS, AND <br />PRACTICES AT THE SITE. <br />B. TEMPORARY SHUTDOWNS: SHALL BE PERFORMED AT NO <br />ADDITIONAL CHARGES TO OWNER. SHUTDOWNS SHALL BE <br />UNDERTAKEN AT TIMES NOT TO INTERFERE WITH NORMAL <br />OPERATION OF EXISTING FACILITIES. OBTAIN WRITTEN CONSENT <br />OF OWNER PRIOR TO SHUTDOWNS. <br />C. ALARM AND EMERGENCY SYSTEMS SHALL NOT BE <br />INTERRUPTED. <br />D. CONNECTIONS TO EXISTING WORK: INSTALL NEW WORK AND <br />CONNECT TO EXISTING WORK WITH MINIMUM INTERFERENCE TO <br />EXISTING FACILITIES. MAINTAIN CONTINUOUS OPERATION OF <br />EXISTING FACILITIES AS REQUIRED WITH NECESSARY <br />TEMPORARY CONNECTIONS BETWEEN NEW AND EXISTING WORK. <br />CONNECT NEW WORK TO EXISTING WORK IN NEAT AND <br />ACCEPTABLE MANNER. RESTORE EXISTING DISTURBED WORK TO <br />ORIGINAL CONDITION INCLUDING MAINTENANCE OF WIRING <br />CONTINUITY AS REQUIRED. <br />E. REMOVAL AND RELOCATION OF EXISTING WORK: <br />1. DISCONNECT AND REMOVE OR RELOCATE ANY <br />ELECTRICAL EQUIPMENT AND/OR DEVICES REQUIRED BY <br />REMOVAL OR CHANGES IN EXISTING CONSTRUCTION. <br />2. REMOVE CONDUCTORS FROM EXISTING RACEWAYS TO <br />BE REUSED AND REPLACE WITH NEW CONDUCTORS. <br />3. REMOVE EXISTING CONDUCTORS NO LONGER USED. <br />REMOVE RACEWAYS IN ALL CASES EXCEPT WHERE THE <br />REMOVAL OF THE RACEWAY WOULD CAUSE DAMAGE TO <br />EXISTING CONSTRUCTION. CAP AND MARK AS <br />"ABANDONED" ANY UNUSED RACEWAYS TO REMAIN. <br />4. CUT AND CAP ABANDONED FLOOR RACEWAYS FLUSH <br />WITH CONCRETE FLOOR OR BEHIND WALLS AND <br />CEILINGS. <br />5. DISPOSE OF ALL REMOVED RACEWAYS AND WIRE. <br />6. DISPOSE OF REMOVED ELECTRICAL EQUIPMENT, <br />LIGHTING FIXTURES, AND DEVICES AS DIRECTED. <br />7. CUT AND PATCH EXISTING CONSTRUCTION AS REQUIRED. <br />ALL PATCHING SHALL BE OF THE SAME MATERIALS, FINISH, <br />AND WORKMANSHIP AS THE EXISTING AREA AND SHALL <br />ACCURATELY MATCH ALL SURROUNDING WORK TO THE <br />SATISFACTION OF THE PROJECT MANAGER. <br />8. IF ASBESTOS INSULATION IS FOUND WHEN WORKING IN <br />EXISTING AREAS, IMMEDIATELY STOP WORK AND NOTIFY <br />PROJECT MANAGER. DO NOT RESTART WORK UNTIL <br />ADVISED IN WRITING BY PROJECT MANAGER THAT IT IS <br />SAFE TO DO SO FOLLOWING ABATEMENT, <br />ENCAPSULATIONS, ETC. <br />1.08 TELECOMMUNICATIONS AND OTHER LOW-VOLTAGE <br />SYSTEMS <br />A. SCOPE: ALL TELECOMMUNICATIONS AND OTHER <br />LOW-VOLTAGE CABLE DESIGNS ARE OUTSIDE OF THE SCOPE OF <br />THE ELECTRICAL DOCUMENTS. THE DOCUMENTS REPRESENT <br />THE GENERAL ARRANGEMENT OF EMPTY RACEWAYS AND BOXES <br />TO ACCOMMODATE THE TELECOMMUNICATIONS AND <br />LOW-VOLTAGE SYSTEMS. CONTRACTOR SHALL VERIFY EXACT <br />RACEWAY, JUNCTION BOX, AND DEVICE BOX REQUIREMENTS <br />WITH THE OWNER'S SELECTED TELECOMMUNICATIONS <br />CONSULTANT PRIOR TO ORDERING THE COMPONENTS OF THE <br />RACEWAY AND BOX SYSTEM. <br />B. SUBMITTALS: CONTRACTOR SHALL SUBMIT ALL COMPONENTS <br />OF THE TELECOMMUNICATION AND OTHER LOW-VOLTAGE <br />SYSTEMS TO THE OWNER'S SELECTED TELECOMMUNICATIONS <br />CONSULTANT FOR APPROVAL. <br />PART II - PRODUCTS <br />2.01 QUALITY ASSURANCE <br />A. QUALITY OF MATERIALS SHALL BE IN ACCORDANCE WITH THE <br />FOLLOWING: <br />1. MATERIALS SHALL BE NEW AND LISTED BY UL (OR <br />SIMILAR AGENCY ACCEPTED BY THE AUTHORITY HAVING <br />JURISDICTION) AND BEARING THEIR LABEL. <br />2. MATERIALS AND EQUIPMENT OF SIMILAR APPLICATION <br />SHALL BE OF THE SAME MANUFACTURE, UNLESS <br />OTHERWISE NOTED. <br />3. MATERIALS SHALL CONFORM TO NEMA, ANSI, AND IEEE <br />STANDARDS. <br />2.02 RACEWAYS <br />A. RIGID GALVANIZED STEEL CONDUIT (RGS): FULL-WEIGHT PIPE, <br />GALVANIZED, THREADED. <br />B. INTERMEDIATE METAL CONDUIT (IMC): LIGHTWEIGHT STEEL <br />PIPE, GALVANIZED, THREADED. <br />C. ELECTROMETALLIC TUBING (EMT): THIN WALL PIPE, <br />GALVANIZED, THREADLESS. <br />D. RIGID NONMETALLIC CONDUIT: SCHEDULE 40 PVC. <br />E. FLEXIBLE STEEL CONDUIT: STANDARD-WALL, GALVANIZED. <br />F. FLEXIBLE ALUMINUM CONDUIT: STANDARD-WALL. <br />G. MINIMUM TRADE SIZE IS 1/2" FOR ALL RIGID AND FLEXIBLE <br />CONDUITS. <br />2.03 RACEWAY FITTINGS AND ACCESSORIES <br />A. RIGID GALVANIZED AND INTERMEDIATE METAL CONDUIT: ZINC <br />DIE CAST NOT PERMITTED. <br />B. ELECTROMETALLIC TUBING: COMPRESSION (WET LOCATIONS) <br />OR DOUBLE SET SCREW TYPE (DRY LOCATIONS ONLY). <br />GALVANIZED RIGID STEEL ELBOWS, 2 IN. OR LARGER. <br />C. FLEXIBLE METALLIC CONDUIT: ANGLE WEDGE TYPE WITH <br />INSULATED THROAT. D. BUSHINGS: METALLIC INSULATED TYPE. <br />2.04 BOXES <br />A. OUTLET BOXES: STAMPED OR WELDED STEEL, 4 IN. SQUARE <br />OR OCTAGON WITH APPROPRIATE MUD RING, EXCEPT AS <br />OTHERWISE REQUIRED BY CONSTRUCTION, DEVICES OR WIRING, <br />AS FOLLOWS: <br />1. LIGHTING FIXTURES: 1-1/2" DEEP ABOVE CEILING, 2-1/8" <br />DEEP IN WALL. <br />2. IN WALL FOR RECEPTACLES, SWITCHES, TELE/DATA <br />DEVICES: 1-1/2" DEEP. <br />3. IN WALL FOR WALL-BOX DIMMERS AND GFCI <br />RECEPTACLES: 2-1/8" DEEP. <br />4. WITH RAISED COVERS AND FIXTURE STUDS WHERE <br />REQUIRED. <br />5. THROUGH-THE-WALL TYPE, NOT PERMITTED. <br />6. WITHOUT FIXTURE OR DEVICE: BLANK COVER. <br />7. OFFSET BACK-TO-BACK OUTLETS: MINIMUM 6 IN. <br />SEPARATION. <br />B. BOXES FOR WET/DAMP LOCATIONS: WEATHERPROOF (NEMA <br />3R), CAST METAL. <br />C. IN HAZARDOUS LOCATIONS: CAST, COPPER-FREE ALUMINUM. <br />D. JUNCTION AND PULL BOXES: GALVANIZED SHEET STEEL, <br />SCREW-ON COVERS, INSULATED SUPPORTS FOR CABLES, <br />INSTALLED ONLY IN ACCESSIBLE LOCATIONS. <br />E. FLOOR BOXES: GALVANIZED CAST IRON WITH BRASS COVERS <br />AND FLANGES, SUITABLE FOR CONDUIT AND DEVICES INDICATED. <br />F. EXTERIOR GRADE-MOUNTED PULL BOXES: CONCRETE OR <br />COMPOSITE FIBER CONSTRUCTION WITH BOLT-DOWN COVERS. <br />METALLIC COVERS ARE NOT PERMITTED. <br />G. PROVIDE BARRIERS IN ALL BOXES BETWEEN 480Y/277 VOLT <br />WIRING ENERGIZED FROM SEPARATE SERVICES, 208Y/120 VOLT <br />AND 480Y/277 VOLT WIRING, EMERGENCY AND NORMAL WIRING. <br />2.05 WIRE AND CABLE <br />A. CONDUCTORS: ASTM STANDARD SOLID; STRANDED FOR #8 <br />AWG AND LARGER. <br />1. TYPE: COPPER, UNLESS OTHERWISE NOTED. <br />CONTRACTOR SHALL NOT SUBSTITUTE ALUMINUM FOR ANY <br />BRANCH CIRCUITS. CONTRACTOR MAY SUBSTITUTE <br />ALUMINUM FOR FEEDERS SIZED #1/0 AWG OR LARGER <br />ONLY WITH WRITTEN CONSENT OF ENGINEER. <br />2. SIZE, FOR GENERAL USE (BASED UPON 10A LOAD): <br />A. #12 AWG MINIMUM FOR ALL CIRCUITS 120V OR <br />MORE. <br />B. FOR 20A/1P 120V BRANCH CIRCUITS OVER 70 FEET <br />IN TOTAL LENGTH: #10 AWG THROUGHOUT ENTIRE <br />CIRCUIT. <br />C. FOR 20A/1 P 120V BRANCH CIRCUITS OVER 110 <br />FEET IN TOTAL LENGTH: #8 AWG FOR HOMERUN, #10 <br />AWG THROUGHOUT REMAINDER OF CIRCUIT. <br />D. FOR 20A/1P 277V BRANCH CIRCUIT HOMERUNS <br />OVER 160 FEET IN LENGTH: #10 AWG THROUGHOUT <br />ENTIRE CIRCUIT. <br />E. FOR 20A/1 P 277V BRANCH CIRCUITS OVER 260 <br />FEET IN LENGTH: #8 AWG FOR HOMERUN, #10 AWG <br />THROUGHOUT REMAINDER OF CIRCUIT. <br />3. SIZE, FOR CONTROL AND ALARM: #14 AWG MINIMUM, <br />EXCEPT FOR 120V CIRCUITS OR CIRCUITS OVER 200 FEET IN <br />LENGTH PROVIDE #12 AWG MINIMUM. <br />4. OTHER VOLTAGES AND PHASES: BRANCH CIRCUIT SIZE <br />ADJUSTED AS REQUIRED TO MAINTAIN VOLTAGE DROP <br />BELOW 3% (FEEDERS BELOW 2%). <br />5. WHERE BRANCH CIRCUITS OR FEEDERS HAVE BEEN <br />ADJUSTED FOR VOLTAGE DROP, INCREASE RACEWAY <br />SIZES FOR LARGER WIRE AS REQUIRED. EQUIPMENT <br />GROUNDING CONDUCTOR TO BE RESIZED TO CORRESPOND <br />TO THE NORMAL AMPACITY OF THE NEW FEEDER SIZE. <br />B. INSULATION: <br />1. THWN-2/THHN: FEEDERS AND BRANCH CIRCUITS EXCEPT <br />AS NOTED. <br />2. SFF-2: BRANCH CIRCUITS LOCATED IN WIRING CHANNELS <br />OF CONTINUOUS FLUORESCENT FIXTURES OR WHERE <br />AMBIENT TEMPERATURES EXCEED 90°C. <br />3. TYPE NM ("ROMEX") CABLE NOT ALLOWED. <br />4. COLOR CODING: CONDUCTORS SHALL BE COLOR CODED <br />TO DIFFERENTIATE THE PHASES, THE SAME COLOR CODE <br />BEING ASSIGNED TO THE SAME PHASE THROUGHOUT THE <br />PROJECT. <br />5. RATING: CONDUCTORS FOR CIRCUITS RATED 30A OR <br />LESS HAVE BEEN SIZED BASED UPON 60° C TEMPERATURE <br />RATING [NEC TABLE 310.15 (B)(16)]. CONDUCTORS FOR <br />CIRCUITS RATED OVER 30A HAVE BEEN SIZED BASED UPON <br />75° C TEMPERATURE RATING. 90° C CONDUCTOR TEMP <br />RATING IS USED ONLY FOR CALCULATING DERATING <br />WHERE ALLOWED BY NEC. <br />C. METAL CLAD (MC) CABLE: FOR BRANCH CIRCUITS IN DRY <br />LOCATIONS, WALLS, HUNG CEILINGS, AND FURRED SPACES TO <br />BRANCH DISTRIBUTION BOX ONLY. NOT ALLOWED FOR <br />HOMERUNS. <br />D. TAGS: PROVIDE TAGS IN ACCESSIBLE LOCATIONS FOR ALL <br />FEEDERS, MADE OF FLAMEPROOF LINEN OR FIBER, INDICATING <br />FEEDER SIZE, PHASE, AND POINTS OF ORIGIN AND <br />TERMINATIONS. <br />E. TERMINATIONS, SPLICES AND TAPS UNDER 600V: <br />1. COPPER CONDUCTORS #10 AWG AND SMALLER: WITH <br />COMPRESSION-TYPE OF TWIST-ON SPRING-LOADED <br />CONNECTORS AND NYLON-INSULATED COVERING. <br />2. COPPER CONDUCTORS #8 AWG AND LARGER: <br />MECHANICAL BOLTED PRESSURE OR <br />HYDRAULIC-COMPRESSION TYPE USING MANUFACTURER'S <br />RECOMMENDED TOOLING. <br />3. CABLE LUGS AND CONNECTORS: COMPRESSION TYPE OF <br />SAME METAL AS CONDUCTOR. PROVIDE TO MATCH CABLE, <br />WITH MARKING INDICATING SIZE AND TYPE. <br />2.06 DEVICES <br />A. LOCAL WALL SWITCHES: HEAVY DUTY, TOGGLE, OR ROCKER <br />QUIET TYPE, 20A, 120/277VAC, COORDINATE WITH ARCHITECT <br />FOR FINISH COLOR. <br />B. DIMMER SWITCHES: SLIDER TYPE, SIZED PER TOTAL <br />CONTROLLED LOAD OR AS INDICATED, COORDINATE WITH <br />ARCHITECT FOR FINISH COLOR. <br />C. RECEPTACLES: <br />A. DUPLEX CONVENIENCE: NEMA 5-20R UNLESS OTHERWISE <br />NOTED, GFCI-TYPE WHERE INDICATED OR REQUIRED BY <br />CODE, COORDINATE WITH ARCHITECT FOR FINISH COLOR. <br />B. SINGLE: NEMA 5-20R UNLESS NOTED OTHERWISE, <br />COORDINATE WITH ARCHITECT FOR FINISH COLOR. <br />C. SPECIAL USE: NEMA TYPES AND RATINGS AS INDICATED <br />ON DRAWINGS OR AS REQUIRED TO MATCH CORD CAP OF <br />EQUIPMENT. <br />D. DEVICE PLATES: VERIFY TYPE WITH ARCHITECT. <br />E. WEATHERPROOF DEVICE COVERS: FOR RECEPTACLES <br />INSTALLED OUTDOORS, PROVIDE NEMA 3R, CAST METAL, <br />LOCKABLE, "IN-USE" TYPE COVERS. <br />2.07 LOW VOLTAGE DISTRIBUTION EQUIPMENT <br />A. DISCONNECT SWITCHES: <br />1. FUSED OR NONFUSED AS NOTED. <br />2. VOLTAGE AS REQUIRED FOR APPLICATION. <br />3. AMPACITY AS REQUIRED FOR APPLICATION (MINIMUM <br />SIZE SHALL BE 125% OF FULL-LOAD AMPS OF EQUIPMENT <br />SERVED, UNLESS OTHERWISE NOTED). <br />4. HEAVY DUTY, UNLESS OTHERWISE NOTED. <br />5. HORSEPOWER RATED FOR MOTOR LOADS. <br />6. TOGGLE TYPE: NON-FUSED, MAXIMUM RATING OF 20A AT <br />600V OR 30A AT 250V, USE ONLY WHEN FULL-LOAD AMPS OF <br />LOAD DOES NOT EXCEED 80% OF SWITCH RATING. <br />7. KNIFE-BLADE TYPE: LOAD BREAK, <br />QUICK-MAKE-QUICK-BREAK, UL CLASS R UP TO 600V, <br />MAXIMUM RATING 800A EXCEPT AS NOTED, ARC <br />QUENCHERS, INDIVIDUALLY MOUNTED EXCEPT AS NOTED. <br />B. CIRCUIT BREAKERS: <br />1. GENERAL REQUIREMENTS: THERMAL-MAGNETIC, <br />QUICK-MAKE-QUICK-BREAK, MANUALLY OPERATED WITH <br />INSULATED TRIP-FREE HANDLE, MULTI-POLE TYPES WITH <br />INTERNAL TRIP BAR, TERMINALS UL LISTED FOR 75° C, <br />SUITABLE FOR COPPER OR ALUMINUM, HACR-RATED TO <br />SUIT APPLICATION, MANUFACTURER TO MATCH EXISTING <br />EQUIPMENT, IF ANY. <br />2. SHORT CIRCUIT INTERRUPTING CAPACITY: <br />A. SIZE TO MATCH EQUIPMENT AIC RATING INDICATED <br />ON DIAGRAMS AND SCHEDULES. <br />B. SERIES-RATED COMBINATIONS: AIC RATINGS ON <br />DRAWINGS ARE BASED UPON FULLY-RATED <br />EQUIPMENT. SERIES-RATED EQUIPMENT IS ALLOWED <br />ONLY IF SPECIFICALLY IDENTIFIED ON THESE <br />DRAWINGS. <br />3. GFCI PROTECTION: WHERE THE ELECTRICAL CODE <br />REQUIRES GFCI PROTECTION OF SPECIFIC RECEPTACLES <br />WHICH ARE NOT READILY ACCESSIBLE (SUCH AS BEHIND <br />REFRIGERATORS OR SIMILAR UTILIZATION EQUIPMENT), <br />PROVIDE GFCI-TYPE CIRCUIT BREAKERS IN LIEU OF GFCI <br />RECEPTACLES. <br />C. MOTOR CONTROLLERS/STARTERS: <br />1. MANUAL MOTOR CONTROLLERS: 600VAC HEAVY DUTY <br />RATED, SINGLE- OR MULTI-POLE TO SUIT APPLICATION, MOUNTED <br />IN SUITABLE NEMA ENCLOSURE, HORSEPOWER RATED TO SUIT <br />MOTOR TO BE CONTROLLED, H-O-A OR START-STOP OPERATION <br />AS NEEDED FOR APPLICATION. <br />D. BRANCH CIRCUIT PANELBOARDS: <br />1. GENERAL REQUIREMENTS: <br />A. PROVIDE FACTORY-ASSEMBLED, ENCLOSED <br />PANELBOARDS WITH DOORS, SURFACE-MOUNTED OR <br />RECESSED AS INDICATED. <br />B. PROVIDE FEEDER TERMINAL LUGS FOR BOTH MAIN <br />BREAKERS AND MAIN LUGS, RATED FOR USE WITH <br />COPPER OR ALUMINUM CABLES AS REQUIRED. <br />C. ALL DOOR LOCKS SHALL BE KEYED ALIKE. <br />D. PROVIDE SEPARATE HINGED AND LOCKABLE <br />DOORS FOR MAIN CONTACTOR COMPARTMENTS AS <br />REQUIRED. <br />E. AIC RATING FOR PANEL BUS SHALL BE AS <br />INDICATED ON DRAWINGS. <br />F. PANEL BUS MAY BE COPPER OR ALUMINUM. <br />G. PROVIDE CONTROL TRANSFORMER FOR THE <br />SHUNT TRIP ELEMENT IN THE PANELBOARD <br />ENCLOSURE AS REQUIRED. <br />H. PROVIDE CIRCUIT DIRECTORY CONSISTING OF <br />METAL FRAME WITH TRANSPARENT PLASTIC COVER. <br />PROVIDE TYPEWRITTEN LIST INDICATING CIRCUIT <br />NUMBERS AND LOADS TO MATCH ACTUAL "AS-BUILT" <br />CONDITIONS (TO CORRESPOND WITH PROJECT <br />RECORD DRAWINGS). <br />2. ACCEPTABLE MANUFACTURERS: SQUARE D, SIEMENS, <br />GENERAL ELECTRIC, AND EATON/CUTLER-HAMMER. <br />E. ENCLOSURES: DEAD FRONT, NEMA TYPE 1 (INDOOR) OR NEMA <br />TYPE 3R (OUTDOOR), UNLESS OTHERWISE NOTED. ALL <br />EQUIPMENT SHALL HAVE SUFFICIENT GUTTER SPACE TO <br />ACCOMMODATE THE THE QUANTITY AND SIZE OF CONDUCTORS <br />REQUIRED. CONTRACTOR SHALL PROVIDE LISTED OVERSIZED <br />ENCLOSURES WHERE REQUIRED. <br />F. TEMPERATURE RATING: ALL LOW-VOLTAGE DISTRIBUTION <br />EQUIPMENT SHALL BE RATED FOR 75° C MINIMUM, NO <br />EXCEPTIONS. <br />G. NAMEPLATES: PROVIDE NAMEPLATES FOR ALL DISCONNECT <br />SWITCHES, ENCLOSED CIRCUIT BREAKERS, PANELS, CABINETS, <br />TRANSFORMER ENCLOSURES, MOTOR CONTROLLERS, <br />DISTRIBUTION BOARDS, AND SWITCHBOARDS. NAMEPLATES <br />SHALL BE FASTENED WITH EPOXY CEMENT, ENGRAVED BLACK <br />BACKGROUND WITH 3/4" WHITE LETTERING, INSCRIPTION <br />INDICATING EQUIPMENT AND VOLTAGE. <br />2.08 LUMINAIRES <br />A. PROVIDE LUMINAIRES, COMPONENTS, AND LAMPS AS <br />SPECIFIED IN THE DRAWINGS. <br />B. LUMINAIRE CATALOG NUMBERS USED TO ILLUSTRATE <br />EQUIPMENT TYPE DO NOT NECESSARILY DENOTE REQUIRED <br />MOUNTING EQUIPMENT OR ACCESSORIES. IT IS THE <br />CONTRACTOR'S RESPONSIBILITY TO PROVIDE FIXTURE <br />MOUNTING TYPES TO SUIT APPLICATION AND TO PROVIDE <br />REQUIRED ACCESSORIES TO SUIT. <br />C. LIGHTING CONTROL SYSTEM: <br />1. GENERAL: PROVIDE LIGHTING CONTROL SYSTEM <br />COMPONENTS AS SPECIFIED ON THE DRAWINGS. <br />CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE ALL <br />COMPONENTS FOR A COMPLETE AND OPERABLE SYSTEM <br />PER MANUFACTURER'S REQUIREMENTS, WHETHER ALL <br />COMPONENTS ARE SPECIFIED IN THE DRAWINGS OR NOT. <br />COORDINATE COMMISSIONING REQUIREMENTS WITH <br />LIGHTING DESIGNER AND/OR ENGINEER AS REQUIRED. <br />2. COMPATIBILITY WITH LED DRIVERS: LIGHTING DIMMING <br />CONTROLS SHALL BE COMPATIBLE WITH THE LED <br />LUMINAIRES AND/OR LAMPS SPECIFIC IN THESE DRAWINGS. <br />CONTRACTOR SHALL VERIFY COMPATABILITY WITH LED <br />AND DIMMER MANUFACTURERS SUCH THAT LED <br />LUMINAIRES AND LAMPS DIM TO 20% OR LESS WITHOUT <br />FLICKERING. <br />D. LAMPS: PROVIDE AS SPECIFIED IN THE DRAWINGS AND TO <br />SUIT APPLICATION. <br />PART III - EXECUTION <br />3.01 INSTALLATION <br />A. GENERAL REQUIREMENTS: <br />1. DO NOT SCALE ELECTRICAL DRAWINGS. VERIFY EXACT <br />LOCATIONS OF ALL FIXTURES, DEVICES, BOXES, <br />RACEWAYS, AND OTHER EQUIPMENT WITH THE DRAWINGS <br />OF ARCHITECTS, INTERIOR DESIGNERS, AND ALL OTHER <br />CONSULTANTS. EACH DEVICE AND FIXTURE HEIGHT SHALL <br />BE VERIFIED WITH OTHERS' DIMENSIONED DRAWINGS <br />(INCLUDING MILLWORK SHOP DRAWINGS) TO ENSURE <br />PROPER HEIGHT AND LOCATION. CONTRACTOR SHALL <br />VERIFY THE EXACT LOCATION OF ALL MECHANICAL <br />EQUIPMENT AND ALL OTHER EQUIPMENT REQUIRING <br />ELECTRICAL CONNECTION PRIOR TO ROUGH-IN. <br />2. THE CONTRACT DRAWINGS INDICATE THE GENERAL <br />ARRANGEMENTS FOR THE ELECTRICAL SYSTEMS. PRIOR <br />TO INSTALLATION, CONTRACTOR SHALL REVIEW THE <br />COMPLETE SET OF CONSTRUCTION DOCUMENTS FOR <br />CONFLICTS WITH OTHER TRADES. DRAWINGS ARE <br />DIAGRAMMATIC AND DO NOT INDICATE ALL OBSTRUCTIONS, <br />OFFSETS, MECHANICAL DUCT OR PIPING CONFLICTS, OR <br />STRUCTURAL CONDITIONS THAT MAY AFFECT THE <br />INSTALLATION. DUE TO THESE OR OTHER LEGITIMATE <br />REASONS, THE CONTRACTOR MAY DECIDE TO INSTALL THE <br />WORK INDICATED IN A MANNER DIFFERENT FROM THAT <br />SHOWN. SUCH CHANGES SHALL BE PRESENTED FOR <br />REVIEW AND APPROVAL FROM THE PROJECT MANAGER <br />PRIOR TO PROCEEDING. UPON APPROVAL, THE WORK <br />SHALL BE PERFORMED AND THE RECORD DRAWINGS <br />PREPARED TO ACCURATELY REFLECT THE WORK AS <br />ACTUALLY INSTALLED. <br />3. IN ALL CASES, MANUFACTURER'S DRAWINGS, DETAILS, <br />AND/OR INSTRUCTIONS SHALL BE FOLLOWED FOR ALL <br />EQUIPMENT AND DEVICES INSTALLED. IN CASES OF <br />CONFLICT WITH THESE DRAWINGS AND SPECIFICATIONS, <br />THE MANUFACTURER'S RECOMMENDED INSTALLATION <br />METHODS SHALL TAKE PRECEDENCE. <br />4. THOROUGHLY CLEAN ITEMS BEFORE INSTALLATION. CAP <br />OPENINGS DURING CONSTRUCTION TO PREVENT <br />INFILTRATION OF DIRT AND OTHER FOREIGN OBJECTS <br />UNTIL FINAL CONNECTIONS HAVE BEEN MADE. <br />5. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL <br />ANCHORS, SUPPORTS, AND CONNECTIONS OF ELECTRICAL <br />WORK TO THE BUILDING STRUCTURE AS REQUIRED BY <br />BUILDING CODES AND IN COMPLIANCE WITH THE LISTING <br />OF THE ANCHORS AND SUPPORTS UTILIZED, INCLUDING <br />MANUFACTURED EQUIPMENT AND THE CONNECTION AND <br />INTEGRITY OF SHOP FABRICATED AND FIELD FABRICATED <br />MATERIALS AND EQUIPMENT. ALL SUPPORTS, EQUIPMENT, <br />AND CONNECTIONS SHALL BE DESIGNED TO CONFORM TO <br />REQUIREMENTS OF THE GOVERNING CODES AND <br />AUTHORITY HAVING JURISDICTION. <br />6. ALL EQUIPMENT SHALL BE SECURELY FASTENED TO <br />BUILDING CONSTRUCTION WITH APPROVED SUPPORTS. ALL <br />WORK SHALL BE PROPERLY SUPPORTED FROM BUILDING <br />STRUCTURE AND/OR FRAMING IN AN APPROVED MANNER <br />INDEPENDENT OF THE CEILING SUPPORT SYSTEM. WHERE <br />OVERHEAD CONSTRUCTION DOES NOT PERMIT DIRECT <br />FASTENING OF SUPPORTS, FURNISH ADDITIONAL FRAMING. <br />7. FIELD-VERIFY FEEDER CONDUCTOR LENGTHS AND <br />TRANSFORMER PARAMETERS (INCLUDING UTILITY <br />TRANSFORMERS) VERSUS THE VALUES LISTED IN THESE <br />DOCUMENTS THAT ARE A PART OF THE AVAILABLE <br />FAULT-CURRENT CALCULATIONS. IF ANY FIELD-VERIFIED <br />CONDITION IS DIFFERENT THAN THOSE DEPICTED IN THESE <br />DRAWINGS, NOTIFY ENGINEER IMMEDIATELY FOR <br />RE-CALCULATION OF AVAILABLE FAULT CURRENTS. <br />B. RACEWAYS, WIRE, AND CABLES: <br />1. ROUTING OF RACEWAY SYSTEMS AS SHOWN IS <br />DIAGRAMMATIC. ACTUAL LOCATION AND ROUTING OF ALL <br />RACEWAYS SHALL BE DETERMINED BY CONTRACTOR TO <br />SUIT FIELD CONDITIONS. <br />2. RACEWAYS SHALL BE INSTALLED CONCEALED, EXCEPT IN <br />AREAS OUT OF PUBLIC VIEW, EQUIPMENT ROOMS, AND <br />OTHER SIMILAR AREAS, OR WHERE CONDITIONS RENDER <br />CONCEALMENT IMPRACTICAL. WHERE EXPOSED, INSTALL <br />PARALLEL WITH OR AT RIGHT ANGLES TO WALLS. WHERE <br />INSTALLED IN MASONRY, RUN VERTICALLY ONLY. <br />3. RIGID STEEL AND INTERMEDIATE METALLIC CONDUIT <br />SHALL BE PERMITTED FOR USE WITH FEEDERS AND <br />BRANCH CIRCUITS. IN EXPOSED AREAS WHERE SUBJECT <br />TO PHYSICAL DAMAGE, USE ONLY RIGID GALVANIZED STEEL <br />CONDUIT. RIGID AND INTERMEDIATE STEEL CONDUIT: USE <br />THREADED RIGID STEEL CONDUIT FITTINGS UNLESS <br />OTHERWISE INDICATED. COMPLY WITH NEMA FB 2.10. <br />4. EMT SHALL BE PERMITTED FOR USE WITH FEEDERS AND <br />BRANCH CIRCUITS, AND MAY BE INSTALLED IN WET <br />LOCATIONS (ABOVE GRADE), DRY LOCATIONS, WALLS, <br />HUNG CEILINGS, HOLLOW BLOCK WALLS, AND FURRED <br />SPACES. <br />5. FLEXIBLE STEEL CONDUIT: USE FOR BRANCH CIRCUITS <br />ONLY. <br />A. PERMITTED USES: DRY LOCATIONS (EXCEPT AS <br />NOTED), IN WALLS, HUNG CEILINGS, AND FURRED <br />SPACES, FOR SHORT CONNECTIONS WHERE RIGID <br />CONDUIT IS IMPRACTICABLE, FROM OUTLET BOX TO A <br />RECESSED LIGHTING FIXTURE (MAXIMUM 6 FT. <br />LENGTH). <br />B. REQUIRED USES: FOR FINAL CONNECTION TO <br />MOTOR TERMINAL BOX, TRANSFORMERS AND OTHER <br />VIBRATING EQUIPMENT (WITH POLYVINYL SHEATHING <br />WHERE INSTALLED IN WET LOCATIONS), FOR <br />EXPANSION JOINT CROSSINGS (CROSS AT RIGHT <br />ANGLES AND ANCHOR ENDS, MINIMUM LENGTH 18" <br />WITH SLACK). <br />6. WHERE ALLOWED BY CODE, MC CABLE MAY BE <br />INSTALLED. WHERE MULTIPLE CABLES ARE ROUTED <br />ADJACENT TO EACH OTHER (BUNDLED), A MINIMUM <br />SEPARATION OF ONE (1) CABLE DIAMETER (LARGEST) <br />SHALL BE MAINTAINED THROUGHOUT THE LENGTH OF THE <br />RUN, OTHERWISE CONTRACTOR SHALL BE RESPONSIBLE <br />FOR DERATING CABLES AS REQUIRED BY CODE. PLASTIC <br />CABLE TIES SHALL NOT BE USED AS MEANS OF SUPPORT. <br />7. SUPPORTS: USE CEILING TRAPEZE, STRAP HANGERS OR <br />WALL BRACKETS (MAXIMUM LOADING 75% OF RATING). USE <br />U-BOLTS AT EACH FLOOR LEVEL OF RISER RACEWAYS, <br />CONNECTED TO ACCEPTABLE SUPPORTS. FOR GROUPED <br />LINES AND SERVICES, USE TRAPEZE HANGERS OF BOLTED <br />ANGLES OR CHANNELS. SECURE RACEWAYS TO SUPPORTS <br />WITH PIPE STRAPS OR U-BOLTS, SPACED MINIMUM 10 FEET <br />ON CENTERS FOR METALLIC RACEWAY AND AS REQUIRED <br />FOR NONMETALLIC RACEWAY, OR PER CODE. WHERE <br />BUILDING CONSTRUCTION IS INADEQUATE PROVIDE <br />ADDITIONAL FRAMING. <br />8. MAINTAIN GROUNDING CONTINUITY OF INTERRUPTED <br />METALLIC RACEWAYS WITH GROUND CONDUCTOR, AND IN <br />FLEXIBLE CONDUIT FOR FEEDERS AND MOTOR TERMINAL <br />CONNECTIONS. <br />9. REAM ENDS OF METALLIC CONDUITS PRIOR RACEWAY <br />SYSTEM ASSEMBLY. <br />10.NO RACEWAY SHALL CONTAIN MORE THAN NINE (9) <br />CURRENT-CARRYING CONDUCTORS UNLESS OTHERWISE <br />NOTED. WHERE MULTIPLE CONDUCTORS (IN EXCESS OF <br />THREE) ARE INDICATED ON THESE DRAWINGS, THEY HAVE <br />BEEN DERATED AS REQUIRED BY CODE. UP TO THREE <br />HOMERUNS FOR 20A/1P #12 AWG BRANCH CIRCUITS MAY BE <br />COMBINED INTO A SINGLE CONDUIT HOMERUN (PROVIDE <br />MULTI-POLE BREAKERS OR HANDLE-TIES ON BREAKERS <br />SUPPLYING MULTIWIRE BRANCH CIRCUITS WITH SHARED <br />NEUTRALS). IN ALL OTHER CASES, CONTRACTOR SHALL <br />NOT COMBINE HOME RUN CONDUITS INTO ONE CONDUIT <br />WITHOUT AUTHORIZATION FROM ENGINEER. <br />11.WHERE MORE THAN ONE CONDUIT TERMINATES IN A <br />JUNCTION BOX, CONTRACTOR SHALL IDENTIFY EACH <br />CONDUIT AND JUNCTION BOX IN A MANNER ALLOWING <br />IDENTIFICATION AFTER ALL WALL FINISHES HAVE BEEN <br />APPLIED. <br />12.PROVIDE FISH OR PULL WIRE, GALVANIZED OR NYLON <br />ROPE IN ALL EMPTY RACEWAYS OVER 10 FEET LONG. <br />13.SLEEVES: FURNISH AND SET ALL SLEEVES FOR PASSAGE <br />OF CONDUIT THROUGH WALLS, ROOF, FLOORS, AND <br />ELSEWHERE AS REQUIRED FOR PROPER PROTECTION OF <br />EACH CONDUIT PASSING THROUGH BUILDING SURFACES. <br />14.SEPARATE RACEWAYS FOR CONDUCTORS OF 208Y/120 <br />AND 480Y/277 VOLT SYSTEMS, EXCEPT 480 VOLT MOTOR <br />BRANCH CIRCUIT WIRING AND RELATED 120 VOLT CONTROL <br />WIRING. <br />15.THREADED CONDUIT JOINTS, EXPOSED TO WET, DAMP, <br />CORROSIVE, OR OUTDOOR CONDITIONS: APPLY LISTED <br />COMPOUND TO THREADS OF RACEWAY AND FITTINGS <br />BEFORE MAKING UP JOINTS. FOLLOW COMPOUND <br />MANUFACTURER'S WRITTEN INSTRUCTIONS. <br />C. OUTLET AND PULL BOXES: <br />1. SET BOXES SQUARE AND TRUE WITH BUILDING FINISH. <br />2. SECURE TO BUILDING STRUCTURE BY ADJUSTABLE <br />STRAP IRONS OR GROUT IN WITH MASONRY. <br />3. VERIFY OUTLET LOCATIONS IN FINISHED SPACES WITH <br />ARCHITECTURAL DRAWINGS OF INTERIOR DETAILS AND <br />FINISHES. <br />4. PROVIDE BARRIERS BETWEEN SWITCHES CONNECTED <br />TO DIFFERENT PHASES FOR VOLTAGES EXCEEDING 150 <br />VOLTS TO GROUND. <br />5. CONCEAL JUNCTION AND PULL BOXES IN FINISHED <br />SPACES, ONLY IN ACCESSIBLE LOCATIONS. <br />6. OUTLET BOXES FOR FIXTURES RECESSED IN HUNG <br />CEILINGS: ACCESSIBLE THROUGH OPENING CREATED BY <br />REMOVAL OF FIXTURE. SECURE TO BLACK IRON CEILING <br />SUPPORT. <br />7. OUTDOOR INSTALLATION: WEATHERPROOF EXCEPT AS <br />NOTED; BELOW GRADE, WATERPROOF. <br />8. CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECT <br />SIZE AND INSTALLATION OF ALL OUTLET, PULL, AND <br />JUNCTION BOXES IN ACCORDANCE WITH NEC 314.16. <br />D. SWITCHBOARDS, DISTRIBUTION BOARDS, PANELBOARDS, AND <br />TRANSFORMERS: <br />1. BALANCE THE LOAD OVER PHASES WHEN NEW CIRCUITS <br />ARE ADDED TO NEW OR EXISTING PANELBOARDS (IF ANY). <br />2. UPDATE DIRECTORIES ON EXISTING PANELBOARDS <br />WHERE CIRCUITING IS CHANGED. <br />3. TESTS: OPEN AND CLOSE LOAD BREAK SWITCHING <br />DEVICES UNDER LOAD. <br />4. ALL FLOOR-MOUNTED EQUIPMENT SHALL HAVE A 3" HIGH <br />HOUSEKEEPING PAD, EXTENDING 3" OR LESS OUTSIDE THE <br />EQUIPMENT FOOTPRINT IN ALL DIRECTIONS (EXCEPT FOR <br />REAR OF SWITCHBOARDS AND DISTRIBUTION BOARDS <br />THAT ARE NOT REAR-ACCESSIBLE). <br />5. ALL EQUIPMENT SHALL BE INSTALLED TO MEET NEC <br />110.26 REQUIRED CLEARANCES. <br />6. CONTRACTOR SHALL VERIFY WITH PROJECT <br />STRUCTURAL ENGINEER (OR RETAIN THE SERVICES OF A <br />LICENSED STRUCTURAL ENGINEER) TO PROVIDE ANY <br />MOUNTING DIAGRAMS OR CALCULATIONS REQUIRED TO <br />VERIFY MOUNTING OF ANY WALL- OR TRAPEZE-MOUNTED <br />TRANSFORMER PRIOR TO ROUGH-IN. ANY RELATED COSTS <br />SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. <br />E. ELECTRICAL ROOMS WITH EQUIPMENT OVER 800 AMPS <br />1. EGRESS DOORS FROM ELECTRICAL ROOMS WITH <br />EQUIPMENT OVER 800 AMPS SHALL INCLUDE PANIC <br />HARDWARE LISTED FOR USE WITH THE DOOR INSTALLED <br />(SPECIFIC TO ANY FIRE-RATINGS OF THE DOOR). <br />F. LUMINAIRES: <br />1. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN(S) <br />OR LIGHTING DESIGN DRAWINGS FOR EXACT LOCATION OF <br />ALL CEILING-MOUNTED LIGHTING FIXTURES. <br />ARCHITECTURAL DRAWINGS OR LIGHTING DESIGN <br />DRAWINGS SHALL GOVERN IN CASE OF CONFLICT WITH <br />ELECTRICAL LIGHTING DRAWINGS. <br />2. RECESSED LUMINAIRES IN FIRE-RATED CEILINGS AND <br />SUPPLY AIR PLENUMS SHALL BE APPROVED FOR THE FIRE <br />RATING OF THE CEILING OR SHALL BE FULLY ENCLOSED IN <br />A FIRE-RATED HOUSING ACCEPTABLE TO THE AUTHORITY <br />HAVING JURISDICTION. <br />3. SEAL ALL OPENING TO ELIMINATE AIR LEAKS. <br />4. VERIFY TYPE OF MOUNTING REQUIRED FOR ALL <br />LUMINAIRES AND PROVIDE ALL MOUNTING HARDWARE AS <br />REQUIRED FOR A COMPLETE INSTALLATION. <br />5. ALL ADJUSTABLE LUMINAIRES SHALL BE PROPERLY <br />AIMED AS DIRECTED BY THE ARCHITECT OR LIGHTING <br />DESIGNER. AIMING OF BUILDING FACADE LIGHTING (IF ANY) <br />SHALL BE PERFORMED AT NIGHT IF REQUIRED BY <br />ARCHITECT OR LIGHTING DESIGNER. <br />6. ALL FLUORESCENT LAMPS INSTALLED IN LUMINAIRES <br />WITH DIMMABLE BALLASTS SHALL BE BURNED AT FULL <br />POWER FOR A MINIMUM OF 24 HOURS PRIOR TO ANY <br />SYSTEM DIMMING TESTS OR COMMISSIONING. <br />G. GROUNDING: <br />1. GROUNDING CONNECTIONS SHALL BE MADE WITH <br />APPROVED CONNECTORS ONLY. <br />2. IN INACCESSIBLE LOCATIONS, MAKE CONNECTIONS BY <br />EXOTHERMIC WELD PROCESS. <br />3. PROVIDE #6 AWG GROUND FOR ALL COMMUNICATIONS <br />CIRCUITS (AT TERMINAL BOARDS AND SIMILAR EQUIPMENT <br />LOCATIONS) IN ACCORDANCE WITH NEC 800.40. <br />4. PROVIDE GROUNDING FOR ALL SEPARATELY DERIVED <br />SYSTEMS PER NEC 250.30 REQUIREMENTS. <br />H. MOTORS: <br />1. WHERE MOTORS ARE INSTALLED IN HUNG CEILINGS, <br />CONTRACTOR SHALL PROVIDE DISCONNECTING MEANS IN <br />HUNG CEILING WITHIN REACH FROM ACCESS POINT. <br />2. SIZING OF MOTOR-RELATED ELECTRICAL COMPONENTS, <br />INCLUDING FEEDER AND/OR BRANCH CIRCUITS (WIRE AND <br />CONDUIT) AND OVERCURRENT PROTECTION (BREAKER <br />AND/OR FUSES) IS BASED UPON RATINGS INDICATED IN THE <br />CONTRACTOR DOCUMENTS AS WELL AS NEC <br />APPROXIMATED LOADS FOR A GIVEN MOTOR <br />HORSEPOWER, VOLTAGE, AND PHASE. IT IS THE <br />CONTRACTOR'S RESPONSIBILITY TO VERIFY ACTUAL <br />MOTOR AND APPLIANCE RATING AND LOADS AND TO <br />PROVIDE CORRECTLY-SIZED MOTOR-RELATED ELECTRICAL <br />COMPONENTS. WHERE EQUIPMENT OVERCURRENT <br />PROTECTION IS RATED ONLY FOR FUSES, THE <br />CONTRACTOR SHALL PROVIDE A FUSED DISCONNECT WITH <br />FUSES SIZED PER MANUFACTURER'S RECOMMENDATIONS, <br />WHETHER SPECIFICALLY INDICATED ON THE DRAWINGS OR <br />NOT. REFLECT ALL CHANGES IN THE RECORD DRAWINGS. <br />I. PENETRATIONS: <br />1. ALL PENETRATIONS OF FIRE-RESISTIVE FLOORS, WALLS, <br />OR OTHER FIRE LISTED ASSEMBLIES SHALL BE PROTECTED <br />BY MATERIALS AND INSTALLATION DETAILS THAT CONFORM <br />TO U.L. LISTING FOR "MEMBRANE-PENETRATION FIRE STOP <br />SYSTEMS" OR "THROUGH-PENETRATION FIRE STOP <br />SYSTEMS" AS APPLICABLE. <br />2. ALL PENETRATIONS OF EXTERIOR ASSEMBLIES SHALL BE <br />PROPERLY SEALED AND WATERPROOFED. <br />J. FIRE/SMOKE DAMPERS: VERIFY EXACT LOCATIONS WITH <br />MECHANICAL DRAWINGS. PROVIDE LINE VOLTAGE MOTOR <br />CONNECTIONS AND LOCAL DISCONNECT SWITCHES AS <br />REQUIRED. PROVIDE DUCT AND/OR AREA SMOKE DETECTORS AS <br />REQUIRED FOR ACTUATION OF DAMPER MOTORS. <br />K. SIGNAGE: <br />1. PROVIDE ALL WARNING SIGNAGE AND LABELLING AS <br />REQUIRED BY CODES AND AUTHORITIES HAVING <br />JURISDICTION. <br />2. PROVIDE SIGNAGE INDICATING AVAILABLE FAULT <br />CURRENT AT SERVICE MAIN DISCONNECT(S) AS INDICATED <br />ON THESE DRAWINGS, INCLUDING (EXISTING CONDITIONS <br />ONLY) IF ANY SUCH EQUIPMENT IS NOT ALREADY LABELLED <br />WITH THIS INFORMATION. <br />L. ACCESS DOORS/PANELS: PROVIDE CONCEALED OUTLET <br />BOXES, JUNCTION/PULL BOXES, AND EQUIPMENT REQUIRING <br />ACCESS WITH ADEQUATELY SIZED ACCESS DOORS/PANELS. IN <br />REMOVABLE TYPE CEILING, PROVIDE ACCESS-TILE <br />IDENTIFICATION ONLY. WHERE ACCESS LOCATIONS ARE NOT <br />DEFINED IN THESE OR OTHER DOCUMENTS, COORDINATE <br />ACCESS POINTS WITH THE GENERAL CONTRACTOR AND/OR <br />ARCHITECT. <br />3.02 PROJECT CLOSE-OUT <br />A. ALL ELECTRICAL SYSTEMS SHALL BE TESTED FOR PROPER <br />OPERATION. IF TESTS SHOW THAT WORK IS DEFECTIVE, <br />CONTRACTOR SHALL MAKE ALL NECESSARY CORRECTIONS AT <br />NO COST TO OWNER. <br />B. UPON COMPLETION OF THE FIRE ALARM SYSTEM'S <br />INSTALLATION, THE SYSTEM INSTALLER SHALL CONDUCT A <br />THOROUGH TEST OF THE SYSTEM TO THE SATISFACTION OF THE <br />AUTHORITY HAVING JURISDICTION AND SUBMIT A WRITTEN <br />REPORT OF THE FINDING TO THE PROJECT MANAGER. <br />C. AFTER FINAL OPERATION FOR INSPECTION AND ACCEPTANCE, <br />DELIVER ALL COPIES OF OPERATION INSTRUCTIONS, <br />MAINTENANCE MANUALS AND PARTS DESCRIPTIONS TO THE <br />ARCHITECT. <br />D. ALL TOOLS SUPPLIED WITH THE EQUIPMENT FOR <br />MAINTENANCE SHALL BE TAGGED AND TEMPORARILY SECURED <br />TO THE UNIT, OR TURNED OVER TO THE OWNER. <br />AS NOTED <br />DRAWN CHECKEDDATE <br />SCALE <br />PROJECT NUMBER <br />SHEETSHEET NAME <br />PROJECT TITLE <br />LOCATION: <br />1 2 3 4 5 <br />B <br />A <br />C <br />D <br />15551 Eden Street <br />Westminster, CA 92683 <br />Copyright. Hu Architecture Inc. 2018. All rights reserved. <br />This drawing and its contents is copyright by Hu Architecture. <br />Reproducing, modifying, and distributing this material without the <br />written permission of Hu Architecture is prohibited.ST <br />A <br />M <br />P <br />CLIENT INFORMATION <br />duchuy@huarchitecture.com <br />(714) 476-4751 <br />NO.DATE DESCRIPTION <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />S <br />CONSULTANT INFORMATION <br />B <br />A <br />C <br />D <br />duchuy@huarchitecture.com <br />(714) 476-4751 <br />?????? <br />2025.103 <br />Laundromat 2710 W Edinger Ave | Equipment Electrical Replacement <br />Unit A, Laundromat 2710 W Edinger Ave <br />Santa Ana, CA 92704 <br />Owner <br />Laundromat 2710 W Edinger Ave <br />Santa Ana, CA 92704 <br />20 <br />2 <br />5 <br />. <br />1 <br />0 <br />3 <br />_ <br /> <br />L <br />a <br />u <br />n <br />d <br />r <br />o <br />m <br />a <br />t <br /> <br />2 <br />7 <br />1 <br />0 <br /> <br />W <br /> <br />E <br />d <br />i <br />n <br />g <br />e <br />r <br /> <br />A <br />v <br />e <br /> <br />| <br /> <br />E <br />q <br />u <br />i <br />p <br />m <br />e <br />n <br />t <br /> <br />E <br />l <br />e <br />c <br />t <br />r <br />i <br />c <br />a <br />l <br /> <br />R <br />e <br />p <br />l <br />a <br />c <br />e <br />m <br />e <br />n <br />t <br />NO DATE DESCRIPTION <br />Phone: (619) 736-3422 <br />Email: hello@s3da-design.com <br />May 250102-10-26 PC COMMENT 01 <br />E 0.1SPECIFICATIONS - ELECTRICAL