My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2120 3%4 S Bristol St WCC02 - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Bristol St
>
2120 3/4 S Bristol St Unit# WCC02
>
2120 3%4 S Bristol St WCC02 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2026 5:00:12 AM
Creation date
4/17/2026 5:00:06 AM
Metadata
Fields
Template:
Plan
Permit Number
20188147
Full Address
2120 3/4 S Bristol St Unit# WCC02
Street Number
2120
Partial
3/4
Street Direction
S
Street Name
Bristol
Street Suffix
St
Unit Number
WCC02
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
197
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br /> <br /> Page 27 of 111 <br /> <br />Report No.: 2410B0143SHA-001 <br /> <br />TRF No. ANSI/CAN/UL 9540A_Unit <br /> <br />ANSI/CAN/UL 9540A <br />Clause Requirement – Test Result - Remark Verdict <br />9.2.19 <br />Heat flux shall be measured with the sensing element of at least two water-cooled <br />Schmidt-Boelter gauges at the surface of each adjacent target BESS unit that faces the <br />initiating BESS unit: <br />Pass <br /> <br />a) One is positioned at the elevation estimated to <br />receive the greatest heat flux due to the thermal <br />runaway of the initiating module within the initiating <br />BESS; and <br />See attachment 7 Pass <br /> <br />b) One is positioned at the elevation estimated to <br />receive the greatest surface heat flux due to the <br />thermal runaway of the initiating BESS. <br />See attachment 7 Pass <br />9.2.19.1 <br />Heat flux measurements on target units may be waived <br />for residential units that are tested with the cheesecloth <br />indicator of 9.2.22. <br />Non-residential units N/A <br />9.2.19.2 <br />With reference to 9.2.19, if a) and b) are deemed to be <br />at the same location, only one gauge may be installed <br />on the target unit for the measurement. <br />Non-residential units N/A <br />9.2.20 <br />For non-residential use BESS and outdoor ground <br />mounted residential use BESS, heat flux shall be <br />measured with the sensing element of at least one <br />water-cooled Schmidt-Boelter or Gardon gauge <br />positioned at the mid height of the initiating unit or the <br />point where the majority of off-gas venting is expected <br />from the initiating unit in the center of the accessible <br />means of egress. <br />Compiled <br />See attachment 7 Pass <br />9.2.21 Measure the temperature of: #24-gauge, type-K exposed TC Pass <br /> the surface proximate to the cells and between the <br />cells and exposed face of the initiating module; See temperature data attached Pass <br /> Each non-initiating module enclosure within the <br />initiating BESS unit; See attachment 6 Pass <br /> convoluted enclosure interior geometries. See attachment 6 Pass <br /> <br />(added by UL CRD-2022.07.21) Temperatures shall be <br />measured continuously, and all temperatures but the <br />cell temperatures are to be averaged over every 60 <br />second interval. The maximum of these averages shall <br />be documented for each thermocouple location. <br />See attachment 6 Pass <br />9.2.22 For residential use BESS, the DUT shall be covered <br />with a single layer of cheese cloth ignition indicator. Non-residential use BESS N/A <br />9.2.23 An internal fire condition in accordance with the module level test shall be created within a <br />single module in the initiating BESS unit: Pass <br /> <br />a) The position of the module shall be selected to <br />present the greatest thermal exposure to adjacent <br />modules, based on the results from the module <br />level test; and <br />Refer to TÜV SÜD Report No.: <br />5061724026506 Pass
The URL can be used to link to this page
Your browser does not support the video tag.