Laserfiche WebLink
2 Hazard Mitigation Analysis <br />Methodology <br />The purpose of this HMA is to provide a record of the decision-making process in <br />determining the fire prevention,fire protection,and explosion prevention requirement for <br />an Ericsson Energy Storage System 6160 installation. <br />This HMA is a living document that continues to evolve.As new information is gathered <br />from new installation environments,operating experience,and equipment evolution,it is <br />expected that this document will be revised and reissued. <br />Inputs to the HMA Process <br />General Inputs <br />Inputs to the HMA process include: <br />State and local building codes and fire codes <br />Industry standards,including fire protection,safety and telecommunications <br />standards <br />Insurance requirements <br />Listing standards and test reports <br />Regulations,including environmental and OSHA regulations <br />Product design documents. <br />Project-Specific Inputs <br />Each facility or installation site may have its own special conditions that impact the <br />nature and extent of the necessary fire protection measured utilized.Many of the <br />specific criteria herein might need modification,due to the consideration of all project- <br />specific factors involved.The project-specific facility,installation,or site inputs utilized <br />in the HMA process include those in the table below: <br />Confidentiality Class External Confidentiality Label Document Type Page <br />Ericsson Internal Analysis 5 (27) <br />Prepared By (Subject Responsible)Approved By (Document Responsible)Checked <br />ERATLEN Thomas Lennholm <br />Document Number Revision Date Reference <br />1785-BFM 107 220/1 Uen PA2 2025-06-03