ELECTRICAL SYMBOL LIST <br />SYMBOL DESCRIPTION <br />SECTION 1. SYMBOLS FOR CONDUITS <br />HOMERUN TO PANEL OR EQUIPMENT AS NOTED <br />CONDUIT RUN CONCEALED IN WALL OR ABOVE FINISHED CEILING OR AS NOTED <br />3/4"C.-3 #12 <br />3/4"C.-4#12 <br />3/4"C.-5#12 3/4"C.-8#12 <br />3/4"C.-6 #12 <br />3/4"C.-7 #12 <br />BRANCH CIRCUIT, 2#12 IN 1/2" CONDUIT OR AS NOTED OR SYMBOLIZED AS: <br />CONDUIT IN OR UNDER SURFACE AS NOTED, 3/4" MINIMUM SIZE. <br />CIRCUIT CONDUCTORS, OR AS NOTED. <br />CONDUIT RUN WITH EQUIPMENT GROUNDING CONDUCTOR, SAME SIZE AS <br />IG CIRCUIT CONDUCTORS, OR AS NOTED. <br />CONDUIT RUN WITH ISOLATED GROUNDING CONDUCTOR, SAME SIZE AS <br />EM CONDUIT WITH EMERGENCY CIRCUIT <br />X EXISTING CONDUIT TO REMAIN. <br />R EXISTING CONDUIT TO BE REMOVED. <br />SECTION 2. EQUIPMENTS <br />A ELECTRICAL PANELBOARD, FLUSH OR SURFACE MOUNTED AS INDICATED <br />LETTERED BALLOON INDICATES DESIGNATION <br />J JUNCTION BOX, ABOVE CEILING, OR AS REQUIRED TO SUIT THE APPLICATION <br />APPROXIMATE LOCATION OF EXISTING J-BOX IN ACCESSIBLE CEILING SPACEJ <br />WITH 3/4" CONDUIT AND PULL WIRE TO ACCESSIBLE CEILING SPACE. <br />DATA OUTLET IN WALL +18" OR AS NOTED. SINGLE GANG OUTLET BOX <br />COMBINATION TELE/DATA OUTLET BOX, +18" OR AS NOTED. SINGLE GANG <br />OUTLET WITH 3/4" CONDUIT AND PULL WIRE TO ACCESSIBLE CEILING SPACE. <br />WALL MOUNTED 2 HOUR BY PASS TIMER (TORK #A500 SERIES) <br />EXH EXHAUST FAN SWITCH, +48" OR AS NOTED ON MECHANICAL DRAWINGS <br />EXHAUST FAN, F.B.M., WIRED BY ELECTRICAL <br />FUSED DISCONNECT SWITCH, SIZE AND FUSED AS NOTED ON PLAN <br />SINGLE POLE SWITCH, +42" OR AS NOTED <br />D WALL MOUNTED DIMMER, 1000 WATT RATING OR AS NOTED. <br />HEIGHTMOUNTING +42" A.F.F. OR AS NOTED. <br />SECTION 3. RECEPTACLES <br />DUPLEX RECEPTACLE FLUSH IN FLOOR BOX WITH DUPLEX HINGE COVERS <br />DUPLEX RECEPTACLE IN WALL 120V, 20AMPS, +18" A.F.F, 3'' ABOVE COUNTER <br />TWO-GANG DUPLEX RECEPTACLE (QUADPLEX) IN WALL, +18" A.F.F OR AS NOTED <br />GFI GFI DUPLEX RECEPTACLE IN WALL, +42" A.F.F OR AS NOTED <br />DUPLEX RECEPTACLE (20 AMP) +18" OR AS NOTED (ON A SEPARATE CIRCUIT) <br />SPECIAL RECEPTACLE NEMA TYPE AS DESIGNATED, +18" OR AS NOTED <br />FLUSH POKE THRU COMBINATION TELE/DATA AND DUPLEX <br />SECTION 4. SENSORS <br />SECTION 5. MISCELLANEOUS <br />REFERENCE TO PLAN NOTES <br />CONDUIT STUBBED UPUP <br />CONDUIT STUBBED DOWNDN <br />(E)DENOTES EXISTING TO REMAIN <br />(N)DENOTES NEW TO MATCH EXISTING <br />(R)DENOTES EXISTING RELOCATED DEVICE AT NEW LOCATION <br />DEMOLITION NOTES <br />THE DRAWINGS SHOW THE WORK TO BE IN PLACE AT THE COMPLETION OF <br />INSTALLATION. MAKE NECESSARY ALTERNATIONS TO COORDINATE AND <br />CONNECT THE EXISTING ELECTRICAL WORK WITH THE NEW SUCH THAT, WHEN <br />THE WORK IS DONE, THE ENTIRE ELECTRICAL INSTALLATION, EXISTING AND NEW, <br />IS IN COMPLETE OPERATING CONDITION. <br />a) <br />EXISTING MATERIAL TO REMAIN UPON COMPLETION IS INDICATED ON DRAWINGS <br />AS EXISTING. FEEDERS (CONDUIT AND WIRES) ARE EXISTING TO THEIR <br />RESPECTIVE SOURCE. ALTHOUGH NOT INDICATED ON THE DRAWINGS, <br />TEMPORARY REMOVAL OR RE-ROUTE CONDUITS AND REPLACE EXISTING WIRES <br />WITH NEW DURING CONSTRUCTION WORK MAYBE REQUIRED. <br />C) <br />PROVIDE AND INSTALL NEW COVER PLATES FOR ALL REMOVED OUTLETS, <br />SWITCHES, LIGHT FIXTURES, AND OTHER ELECTRICAL DEVICES WHEN THE <br />OUTLET BOX IS TO REMAIN. <br />d) <br />REMOVE ALL EXISTING ABANDONED FEEDERS (CONDUITS AND WIRES) BACK TO <br />PANEL BOARDS. LABEL NEW PANEL DIRECTORY AS "SPARE". <br />e) <br />MAINTAIN CONTINUITY OF ALL ELECTRICAL SYSTEMS, EQUIPMENT, ETC., FED BY <br />ABANDONED OUTLET. THEY SHOULD BE IN OPERATION AFTER THE WORK IS <br />DONE. MAINTAINING CONTINUITY SHALL CONSIST OF RE-ROUTING OF CONDUIT <br />AND WIRING, AS REQUIRED TO SUIT THE EXISTING CONDITIONS. <br />f) <br />DASHED J-BOX DENOTES APPROXIMATE LOCATION OF EXISTING BOXES IN <br />ACCESSIBLE CEILING SPACE. ALL CONDUIT SHOWN FROM J-BOX IS NEW UNLESS <br />SHOWN OTHERWISE AS DASHED. REFER TO ELECTRICAL SYMBOL LIST. <br />g) <br />EXISTING LOADS SHOWN ON PANEL SCHEDULES ARE BASED ON ASSUMPTIONS <br />MADE BY FIELD VISIT, ELECTRICAL BILLS OR PUBLIC RESOURCES. NOTIFY <br />ENGINEER IMMEDIATELY IF LOADS EXCEED 16 AMPS ON ANY 20A/1P CIRCUIT. <br />NO EXCEPTION. <br />h) <br />CAREFULLY REVIEW ARCHITECT'S DEMO DRAWINGS FOR LOCATION OF WALLS <br />BEING REMOVED UNDER THIS SCOPE OF THIS WORK AND REMOVE ALL FEEDERS <br />(CONDUITS AND WIRES) BACK TO LAST DEVICE LEFT IN SERVICE. DO NOT LEAVE <br />ABANDONED. <br />i) <br />CAREFULLY REVIEW ARCHITECT'S DEMO DRAWINGS FOR EXISTING FLOOR <br />BOXES BEING REMOVED UNDER THIS SCOPE OF WORK. REMOVE FLOOR BOXES <br />AND ALL FEEDERS (CONDUITS AND WIRES) BACK TO LAST DEVICE LEFT IN <br />SERVICE. DO NOT LEAVE ABANDONED. <br />j) <br />UNLESS SPECIFICALLY NOTED ON THE CONTRARY, ALL EXISTING LIGHTING <br />FIXTURES, SWITCHES, CONTROLS AND OTHER MATERIALS OR EQUIPMENTS <br />WHICH ARE REPLACED BY NEW AND ARE NOT INDICATED TO BE REUSED SHALL <br />BE RETURNED TO THE OWNER OR BE DISPOSED AS DIRECTED BY THE OWNER. <br />b) <br />GENERAL ELECTRICAL NOTES <br />VERIFY IN FIELD. ADJUST THE LOCATIONS OF HOMERUNS AND CIRCUIT NUMBERS <br />ACCORDING TO EXISTING CONDITIONS IF NEEDED. COMMUNICATE WITH <br />ENGINEER IF DESIGN SHOULD BE ALTERNATED. NO EXCEPTION. <br />a) <br />IF THERE IS ANY DEVIATION FROM THE CIRCUITRY SHOWN, PROVIDE AS-BUILT <br />DRAWINGS INDICATING SUCH. <br />C) <br />AT THE COMPLETION OF CONSTRUCTION WORK, AND PRIOR TO THE FINAL <br />REVIEW BY THE ARCHITECT, PROVIDE PANEL DIRECTORIES IN PANELBOARD <br />FRONTS REFLECTING ALL CHANGES MADE DURING CONSTRUCTION. <br />d) <br />IDENTIFY ANY OBVIOUS EXISTING CODE VIOLATIONS THAT OCCURS AS AN <br />EXISTING CONDITION AND PROVIDE SEPARATE PRICING TO CORRECT THE <br />CONDITION SO THAT IN THE END, THE ENTIRE ELECTRICAL INSTALLATION <br />COMPLIES WITH THE NATIONAL ELECTRICAL CODE AND ALL OTHER LOCAL <br />CODES. <br />b) <br />OR AS NOTED. <br />DUPLEX PLUG RECEPTACLE, 120V, 20A, SHADED SIDE INDICATES "ISOLATED <br />GROUND" TYPE DUPLEX ECEPTACLE. 18''A.F.F, 3'' ABOVE COUNTER OR AS <br />NOTED, DEVICE TO BE "ORANGE" IN COLOR. <br />D WALL MOUNTED DIMMER W/ OCCUPANCY SENSOR, LUTRON MAESTRO OR <br />APPROVED EQUAL, HEIGHTMOUNTING +42" A.F.F. OR AS NOTED. <br />O.S. <br />WALL MOUNTED MOTION SENSOR (THE WATT STOPPER "WA-300"). <br />OR EQUIVALENT. <br />THIS DOCUMENT IS NOT FOR BID OR CONSTRUCTION UNTIL THE PLAN HAS BEEN <br />REVIEWED AND APPROVED BY ALL AUTHORITIES HAVING JURISDICTION AND THE <br />PERMIT IS OBTAINED. NO COMPENSATION WILL BE MADE FOR ADDITIONAL WORK <br />DUE TO THE VIOLATION OF THIS REQUIREMENT. <br />e) <br />JOB NUMBER: <br />DATE: <br />The plans and specifications prepared by JONATHAN WANG DESIGN are protected from <br />unauthorized modification, reuse and/or release under California Business & Professions Code <br />section 5536.4, Health & Safety Code Section 19851(a), and Education Code Section 17316. <br />12621 WASHINGTON PL <br />LOS ANGELES, CA, 90066 <br />(626) 684-6651 <br />jwang@jonathanwangdesign.com <br />www.jonathanwangdesign.com <br />JONATHAN <br />WANG <br />DESIGN <br />Lynnko Bakery <br />2 Hutton Center Dr, <br />#200, Santa Ana, CA <br />92707. <br />25-799 <br />04/02/2026 <br />REVISIONS <br />CAUTION <br />GMEP ENGINEERS SHALL NOT BE RESPONSIBLE FOR ANY ELECTRICAL CHANGE <br />ORDERS THAT MAY OCCUR SHOULD FINAL BIDS AND/OR CONSTRUCTION BASED ON <br />THESE DOCUMENTS BE STARTED PRIOR TO ELECTRICAL PLAN CHECK APPROVAL. <br />ALL EQUIPMENTS SHALL BE U.L. LISTED AND INSTALLED ACCORDING TO THE <br />LISTING. <br />ALL CONDUCTORS SHALL BE COPPER AS FOLLOWS: <br />#12 AWG AND SMALLER - SOLID, TW <br />#10 AWG AND LARGER - STRANDED, THWN, THHN OR XHHW <br />CONDUCTORS: <br />IMPORTANT BID NOTES: <br />DUE TO THE SMALL SCALE OF DRAWINGS, IT IS NOT ALWAYS POSSIBLE TO SHOW <br />ALL DEVICES WHICH MAYBE REQUIRED. CONTRACTOR SHALL BE RESPONSIBLE <br />TO VERIFY ALL EXISTING CONDITIONS BEFORE SUBMITTING HIS BID. NO <br />ADDITIONAL COMPENSATION WILL BE MADE FOR EXTRA DUE TO CONTRACTOR'S <br />FALIURE TO VISIT THE JOB SITE AND/OR FAILURE TO DETERMINE ALL EXISTING <br />CONDITIONS BEFORE SUBMITTING HIS BID. <br />a) <br />b)REFER TO COMPLETE ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND <br />PLUMBING DRAWINGS FOR ADDITIONAL NOTES, SPECIFICATIONS, DETAILS, <br />CONTROLS, ETC. REPORT TO ARCHITECTURE IMMEDIATELY IF ANY CONFLICTS <br />OCCUR BETWEEN THE DRAWINGS AND INCLUDE ALL COST PER ARCHITECTURE'S <br />CLARIFICATION IN BASE BID. THIS REQUIREMENT WILL BE STRICTLY ENFORCED. <br />NO CHANGE ORDERS WILL BE ALLOWED IF THE CONTRACTOR FAILS TO PERFORM <br />THIS FUNCTION. <br />MOUNTING HEIGHT FOR RECEPTACLES AND CONTROL DEVICES: <br />THE TOP OF SWITCHES SHALL BE INSTALLED NOT LESS THAN 36'' NOR MORE <br />THAN 46'' ABOVE THE FINISH FLOOR. <br />c) <br />THE BOTTOM OF ELECTRICAL AND COMMUNICATION RECEPTACLES INTENDED TO <br />BE USED BY THE OCCUPANT SHALL BE LOCATED NO LESS THAN 15". [ADA <br />ACCESSIBITY GUIDELINES 4.27.3] <br />a) <br />RECEPTACLE OUTLETS SHALL BE LOCATED ABOVE, BUT NOT MORE THAN 20 IN. <br />ABOVE, THE COUNTERTOP. SUGGESTION HEIGHT IS 6'' [NEC 210.52.C(5)] <br />b) <br />d)THERMOSTAT CONTROLS SHALL BE LOCATED NOT LESS THAN 36" NOR MORE <br />THAN 46" ABOVE FINISH FLOOR LINE. <br />ALL WORK TO COMPLY WITH THE 2025 CBC, CPC AND CMC AND THE 2025 CEC (2023 <br />NEC) WITH STATE AND LOCAL AMENDMENTS. <br />ALL CONDUCTORS SIZES ARE BASED ON 75C TEMPERATURE RATING <br />(CEC. 2025 TABLE 310.16) <br />ELECTRICAL GENERAL NOTES <br />E-1.0ALL 15 AND 20 AMPERE, 125 AND 250 VOLT NON-LOCKING TYPE RECEPTACLES IN <br />THE AREAS SPECIFIED PER CODE 406.12 SHALL BE LISTED TAMPER-RESISTANT <br />RECEPTACLES. <br />f) <br />SCALE: <br />KEY PLAN <br />NONE <br />E MACARTHUR BLVD <br />MA <br />C <br />A <br />R <br />T <br />H <br />U <br />R <br /> <br />P <br />L <br />AREA OF WORK <br />2 HUTTON CENTRE DR <br />(E)SWITCHGEAR <br />1200A 120/208V-3 -4W