Laserfiche WebLink
JOB NUMBER: <br />DATE: <br />The plans and specifications prepared by JONATHAN WANG DESIGN are protected from <br />unauthorized modification, reuse and/or release under California Business & Professions Code <br />section 5536.4, Health & Safety Code Section 19851(a), and Education Code Section 17316. <br />12621 WASHINGTON PL <br />LOS ANGELES, CA, 90066 <br />(626) 684-6651 <br />jwang@jonathanwangdesign.com <br />www.jonathanwangdesign.com <br />JONATHAN <br />WANG <br />DESIGN <br />Lynnko Bakery <br />2 Hutton Center Dr, <br />#200, Santa Ana, CA <br />92707. <br />25-799 <br />04/02/2026 <br />REVISIONS <br />SINGLE LINE DIAGRAM <br />E-1.1 <br />SINGLE-LINE DIAGRAM KEYED NOTES <br />THE EQUIPMENT SHOWN IS EXISTING UNDER A PREVIOUS APPROVED <br />CONSTRUCTION PERMIT, NOT A PART OF THIS SUBMITTAL, UNLESS NOTED AS NEW.1 <br />ALL NEW CIRCUIT BREAKERS, FUSIBLE SWITCHES IN MAINSWITCHBOARD OR <br />PANEL BOARDS SHALL BE SERIES RATED TO MATCH EXISTING AIC RATING OR <br />APPROVED EQUAL OR 65KAIC, UNLESS NOTED OTHERWISE. <br />b) <br />FUSES SHALL BE PROVIDED WITH REJECTION TYPE FUSE HOLDERS.f) <br />NO PIPING, DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL <br />BE PERMITTED TO BE LOCATED WITHIN THE DEDICATED SPACE ABOVE THE <br />ELECTRICAL EQUIPMENT. <br />h) <br />MAIN SERVICE WILL NOT ENERGIZED PRIOR TO THE BUILDING INSPECTOR'S <br />RECEIPT OF A THIRD PARTY "NRTL" TESTING LABORATORY PERFORMANCE TEST <br />CERTIFICATION FOR THE SERVICE GROUND FAULT PROTECTION. 2023 NEC 230.95 <br />i) <br />ALL CONDUCTORS SHALL BE COPPER AS FOLLOWS:a) <br />#12 AWG AND SMALLER - SOLID, TW <br />#10 AWG AND LARGER - STRANDED, THWN, THHN OR XHHW <br />ALL CONDUCTORS SIZES ARE BASED ON 75C TEMPERATURE RATING <br />(CEC. 2025 TABLE 310.16) <br />SERIES COMBINATION AIC RATING SHALL NOT BE USED WHEN THE SECONDARY <br />EQUIPMENT IN THE SERIES IS SUBJECTED TO A TOTAL CONNECTED FULL LOAD <br />MOTOR CURRENT OF MORE THAN 1% OF ITS AIC RATING. <br />d) <br />MOTOR CIRCUIT PROTECTORS SHALL NOT BE A PART OF A SERIES COMBINATION <br />INTERRUPTING RATING. <br />c) <br />EQUIPMENT ENCLOSURES SHALL BE CLEARLY MARKED "CAUTION-SERIES RATED <br />SYSTEM - 65KAMPS AVAILABLE, IDENTIFIED REPLACEMENT COMPONENTS <br />REQUIRED", IN COMPLIANCE WITH 2025 CEC (2023 NEC) SECTION 110-22. END <br />USE EQUIPMENT SHALL ALSO BE MARKED WITH THE HIGHER SERIES <br />COMBINATION INTERRUPTING RATING AS PER 2025 CEC SECTION 240-83(C). NO <br />EXCEPTION. <br />e) <br />ELECTRICAL EQUIPMENT SHALL BE LISTED BY THE CITY, WHERE THE PROJECT IS <br />LOCATED, RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY <br />THE DEPARTMENT. <br />g) <br />SINGLE-LINE DIAGRAM GENERAL NOTES <br />ELECTRICAL SINGLE LINE <br />SCALE: NONE <br />CT'S <br />GND BUS <br />(E) GROUND <br />(E) GROUND 1 <br />(E)1200A BUS <br />1 <br />1 <br />M <br />1 <br />1 <br />(E) <br />1 <br />1 <br />EXISTING <br />SERVICE <br />FEEDER <br />(E)DISTRIBUTION SECTION <br />1200A 120/208V-3 -4W <br />65 KAIC OR MATCH FAULT CURRENT ON SITE <br />(E)METER&MAIN <br />BREAKER <br />SECTION <br />(E)1200A <br />UNDERGROUND <br />PULL SECTION <br />(E) <br />1200A <br />3P <br />1 1 1 <br />NO WORK <br />1 <br />CT'S M <br />(E) <br />1 <br />1 <br />(E) <br />400A <br />3P <br />CT'S M <br />(E) <br />1 <br />(N) <br />250A <br />3P <br />PANEL <br />`A' <br />(E) <br />1 <br />(E <br />) <br />[ <br />2 <br />] <br />1 <br />- <br />1 <br />/ <br />2 <br />" <br />C <br />. <br />, <br /> <br />4 <br /># <br />1 <br />/ <br />0 <br /> <br />C <br />U <br />. <br />PL <br />U <br />S <br /> <br />1 <br /># <br />4 <br /> <br />C <br />U <br />. <br /> <br />G <br />N <br />D <br />. <br />~1 <br />6 <br />5 <br />' <br />; <br /> <br />V <br />D <br /> <br />< <br />= <br /> <br />2 <br />% <br />ELECTRICAL WIRING METHODS <br />FOR UNDERGROUND AND EXPOSED UP TO +5'-0'', OR DAMP LOCATION, THE <br />CONDUIT SHALL BE RIGID STEEL GALVANIZED IMC. NO RUNNING THREADS ARE <br />PERMITTED. <br />a) <br />GALVANIZED EMT SHALL BE USED IN DRY CONCEALED LOCATIONS AND EXPOSED <br />ABOVE +5'-0". EMT CONNECTORS SHALL BE WATERTIGHT COMPRESSION TYPE. <br />b) <br />GALVANIZED FLEXIBLE CONDUIT SHALL BE USED ONLY FOR MOTOR AND FIXTURE <br />CONNECTIONS IN LENGTHS NOT TO EXCEED 6'. <br />c) <br />CONDUITS PENETRATING THE ROOF SHALL BE FLASHED AND COUNTER FLASHED.d) <br />PVC SCHEDULE 40 MAY BE USED UNDER FLOOR SLABS OR UNDERGROUND WITH <br />GROUND WIRE. PVC UNDERGROUND TO HAVE 24 INCH COVER. <br />e) <br />SERVICE CONDUITS SHALL BE PVC SCHEDULE 40 OR AS SPECIFIED BY UTILITY <br />COMPANIES. <br />f) <br />INSTALL FITTINGS, SPECIAL DEVICES AND MATERIAL, WHICH MAY BE REQUIRED <br />FOR THE PROPER INSTALLATION OF THE CONDUIT SYSTEM. <br />g) <br />REFER TO NEC 300.5 FOR UNDERGROUND INSTALLATION REQUIREMENTS AND <br />DETAILS; NEC 300.6 FOR CORROSION AND DETERIORATION AREAS. <br />h) <br />PANEL <br />'B' <br />(E) <br />(E)125A/3P <br />(E <br />) <br />2 <br />" <br />C <br />. <br />, <br /> <br />4 <br /># <br />1 <br />/ <br />0 <br /> <br />C <br />U <br />. <br />PL <br />U <br />S <br /> <br />1 <br /># <br />6 <br /> <br />C <br />U <br />. <br /> <br />G <br />N <br />D <br />. <br />~5 <br />' <br />; <br /> <br />V <br />D <br /> <br />< <br />= <br /> <br />2 <br />% <br />1 <br />1 <br />PANEL <br />DESCRIPTION <br />W <br />VOLT AMPS L <br />T <br />G <br />R <br />E <br />C <br />M <br />I <br />S <br />BKR CKT <br /> NO <br />BUS CKT <br /> NO BKR <br />M <br />I <br />S <br />R <br />E <br />C <br />L <br />T <br />G <br />VOLT AMPS DESCRIPTION <br />LOCATION <br />MAIN (AMP) <br />BUS RATING <br />FED FROM MOUNTING: <br />V Φ <br />ΦA ΦB ΦC ΦA ΦB ΦC ΦA ΦB ΦC <br />'A'ELECTRIC ROOM <br />M.L.O. <br />250A <br />'' <br />120/208 <br />RECESSED <br />3 4 <br />(E)WALK-IN COOLER CONDENSER 1675 30 1 <br />---1675 2 3 <br />(E)WALK-IN COOLER EVAP 270 20-1 5 <br />(E)COOLER/LIGHTS FAN 300 20-1 7 <br />KITCHEN OUTLETS 900 20-1 9 <br />KITCHEN OUTLETS 900 20-1 11 <br />EF-R 50 20-1 13 <br />DINING AREA OUTLETS 540 20-1 15 <br />DINING AREA OUTLETS 1080 20-1 17 <br />#14 VENTLESS COUNTERTOP OVEN 2080 25 19 <br />---2080 2 21 <br />(E)BAG-IN-BOX 300 20-1 23 <br />#29 2 DOOR REACH IN FREEZER 1040 20-1 25 <br />(E)HEAT LAMP 300 20-1 27 <br />#26 AND #27 OUTLETS 360 20-1 29 <br />#25 COMBI OVEN 960 20-1 31 <br />(E)HEAT LAMP 300 20-1 33 <br />#30 RETARDER PROOFER 2750 30 35 <br />---2750 2 37 <br />#30 RETARDER PROOFER 2750 30 39 <br />---2750 2 41 <br />#06 HOT WATER DISPENSER 1850 20-1 <br />(E)HP-72A2430402 <br />---24304 <br />---243036 <br />(E)HP-72B2566508 <br />---256610 <br />---2566312 <br />(E)SUPPLY FAN (HOOD)50020-114 <br />(E)EXHAUST FAN (HOOD)40020-116 <br />(E)EXHAUST FAN (HOOD)40020-118 <br />#31 REVERSIBLE DOUGH SHEETER5402020 <br />---54022 <br />---540324 <br />(E)ROOF OUTLET18020-126 <br />SPARE20-128 <br />(E) #43 AIR CURTAIN59020-130 <br />(E)ROOF OUTLET18020-132 <br />#15 60" DISPLAY FRIDGE87020-134 <br />#28 2 DOOR REACH IN FRIDGE52020-136 <br />#24 DECK OVEN57556038 <br />---575540 <br />---5755342 <br />PANEL 'B'937012544 <br />---932046 <br />---7730348 <br />1 <br />1 <br />1 <br />2 <br />2 <br />2 <br />4 <br />1 <br />1 <br />1 <br />1 <br />2 <br />3 <br />SUB-TOTAL ΦA ΦB ΦC27539VA26722VA 25003VA=== <br />(EXISTING PANEL) <br />NOTES: <br />1 DENOTES EXISTING CIRCUIT BREAKER TO REMAIN; ALL OTHERS ARE NEW TO <br />MATCH EXISTING. <br />2 THE KITCHEN DEMAND FACTOR IS BEING APPLIED TO THE KITCHEN <br />EQUIPMENT (NEC 220.56). <br />3 THE BREAKER IS THE LARGEST MOTOR LOAD (LML) TAKEN AT 125% OF ITS <br />FULL-LOAD CURRENT RATING (NEC 430.24(1)). <br />4 THE BREAKER IS A LONG CONTINUOUS LOAD (LCL) TAKEN AT 125% OF ITS <br />CURRENT DRAW (NEC 210.19(A)(1)). <br />81.3 KVA <br />235.5 A <br />TOTAL CONNECTED VA 79264= <br />LCL @ 125 % 3350 =4188 <br />LML @ 125 %4445 =5556 <br />PANEL LOAD = <br />FEEDER AMPS = <br />PANEL <br />DESCRIPTION <br />W <br />VOLT AMPS L <br />T <br />G <br />R <br />E <br />C <br />M <br />I <br />S <br />BKR CKT <br /> NO <br />BUS CKT <br /> NO BKR <br />M <br />I <br />S <br />R <br />E <br />C <br />L <br />T <br />G <br />VOLT AMPS DESCRIPTION <br />LOCATION <br />MAIN (AMP) <br />BUS RATING <br />FED FROM MOUNTING: <br />V Φ <br />ΦA ΦB ΦC ΦA ΦB ΦC ΦA ΦB ΦC <br />'B'ELECTRIC ROOM <br />M.L.O. <br />200A <br />PANEL 'A' <br />120/208 <br />RECESSED <br />3 4 <br />(E)EXIT/NIGHT LIGHT 400 20-1 1 <br />(E)DINING ROOM LIGHTS 300 20-1 3 <br />(E)DINING ROOM LIGHTS 400 20-1 5 <br />(E)PADDLE FANS 500 20-1 7 <br />(E)TRACK LIGHTS 300 20-1 9 <br />(E)COUNTER LIGHTS 300 20-1 11 <br />(E)KITCHEN LIGHTS 500 20-1 13 <br />(E)RESTROOM LIGHTS 400 20-1 15 <br />(E)HOOD LIGHTS/CONTROLE 300 20-1 17 <br />(E)CASH REGISTER 360 20-1 19 <br />(E)DISHWASHER 1200 20-1 21 <br />COUNTER LTS 150 20-1 23 <br />220V OUTLET 180 20-1 25 <br />(E)OUTLET/AQUARIUM/TIMECLOCK 540 20-1 27 <br />(E)ALARM POWER 100 20-1 29 <br />(E)OFFICE OUTLETS 540 20-1 31 <br />(E)MANAGERS COMPUTER 360 20-1 33 <br />#17 72" UNDERCOUNTER FRIDGE 690 20-1 35 <br />#32 BUN DIVDER 220 20 37 <br />---220 39 <br />---220 3 41 <br />#01 46" UNDERCOVER FRIDGE35020-12 <br />#02 SMOOTHIE BLENDER120020-14 <br />#03 BLENDER138020-16 <br />#04 JUICER96020-18 <br />#05 TEA BREWER173020-110 <br />#46 BUBBLE TEA MACHINE69020-112 <br />#17 72" UNDERCOUNTER FRIDGE69020-114 <br />#08 SYRUP MACHINE30020-116 <br />SPARE20-118 <br />#23 PLANETARY MIXER 20QT165020-120 <br />(E) #33 ICE MACHINE12002022 <br />---1200224 <br />#09 COFFEE BREWER180020-126 <br />#12 60" UNDERCOUNTER FRIDGE35020-128 <br />#10 COFFEE GRINDER108020-130 <br />#21 SPIRAL DOUGH MIXER 50QT7302032 <br />---73034 <br />---730336 <br />#22 SPIRAL DOUGH MIXER 25QT4902038 <br />---49040 <br />---490342 <br />1 <br />2 <br />2 <br />2 <br />1 <br />1 <br />SUB-TOTAL ΦA ΦB ΦC9370VA9320VA 7730VA=== <br />(EXISTING PANEL) <br />NOTES: <br />1 DENOTES EXISTING CIRCUIT BREAKER TO REMAIN; ALL OTHERS ARE NEW TO <br />MATCH EXISTING. <br />2 THE BREAKER IS A LONG CONTINUOUS LOAD (LCL) TAKEN AT 125% OF ITS <br />CURRENT DRAW (NEC 210.19(A)(1)). <br />27.2 KVA <br />80.0 A <br />TOTAL CONNECTED VA 26420= <br />LCL @ 125 % 3050 =3812 <br />LML @ 125 %0 =0 <br />PANEL LOAD = <br />FEEDER AMPS = <br />81.3 KVA <br />235.5 A <br />27.2 KVA <br />80.0 A <br />2 <br />2 <br />2 <br />2