My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4012 & 4042 W Garry Ave - Plan
PBA
>
Building
>
ProjectDox
>
G
>
Garry Ave
>
4012 W Garry Ave
>
4012 & 4042 W Garry Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/21/2026 5:00:11 AM
Creation date
4/21/2026 5:00:06 AM
Metadata
Fields
Template:
Plan
Permit Number
101125972
101125973
Full Address
4012 W Garry Ave
4042 W Garry Ave
Street Number
4042
Street Direction
W
Street Name
Garry
Street Suffix
Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
MINOR GRADING PLAN <br />LN CIVIL ENGINEERS, INC. <br />O <br />Exp. 6-30-2025 <br />TTAE <br />S NROFACLIF <br />AI <br />No. 46771 <br />R <br />E <br />ET <br />GN <br />G <br />SI LOR <br />PDE <br />R E <br />FO <br />M NGYU <br />NE I <br />EN <br />LAOINSSE <br />NG E <br />R <br />. <br />VIC IL <br />UTILITY COMPANIES <br />Underground Service Alert <br />Section 4216/4216.9 of the Government Code <br />requires a DIG ALERT Identification Number be <br />issued before a "Permit to Excavate" will be valid. <br />For your Dig Alert I.D. Number Call Underground <br />Service Alert 811 two working days before you dig <br />OWNER: <br />811 <br />VICINITY MAP <br />N <br />N <br /> 3' "V" GUTTER DETAIL CONCRETE CURB DETAIL <br />A A <br />SECTION A-A <br />GASKET ASSEMBLY <br />SUPPORT BRACKET D <br />C <br />B <br />A A <br />B <br />C <br />D <br />8 7 6 5 4 3 2 1 <br />8 7 6 5 4 3 2 1 <br />E <br />F <br />E <br />F <br />RE <br />V <br />D <br />To <br />p <br />H <br />a <br />t <br />01-004 <br />SHEET 3 OF 3 <br />A.C.2/6/14 <br />SCALE: 1:6WEIGHT: <br />DWG. NO.REVDSIZE <br />TITLE: <br />NAME DATE <br />COMMENTS: <br />Q.A. <br />MFG APPR. <br />ENG APPR. <br />CHECKED <br />DRAWN <br />A <br />A <br />TOP HAT FILTER <br />1. All dimensions are in inches, unless otherwise noted.2. The TRITON - TH (Top Hat) Series Filters may be customized in the field to fit catch basins with irregular dimensions or unusual frame and grate types. REM also designs custom filters for unique storm water infrastructures and applicaKons.3. Base plates are constructed using non-reacKve high density polyethylene plasKc (HDPE) with added U.V. inhibitors.4. Filter cartridge housings are constructed uKlizing Type 304 Stainless Steel, with 2" welded square openings. <br />5. Removable cartridge tops are constructed uKlizing over 40% recycled Non-reacKve High Density Polystyrene PlasKc with added U.V. <br /> inhibitors.6. REM TRITON replacement Filter Media Packs are charged with REM FOG media an expanded volcanic ash medium treated to be highly hydrophobic housed in a durable geo-texKle perforated polypropylene woven fabric. REM FOG media effecKvely encapsulates liquefied <br /> petroleum hydrocarbons (Fats, Oils & Grease including animal fats). The media’s hydrophobic characterisKc allows for greater polishing of flow resulKng in the reducKon of Total Suspended Solids (TSS). Suspended solid reducKon includes but is not limited to debris, trash, silt sediment and agglomerated heavy metals. (AddiKonal media opKons are available including mixed blends of granulated carbon [AC] and Zeolite [ZEO]). For trash/debris capturing only, Bioflex Media (BFTG) should be chosen.7. The Top Hat filter design requires water flows to filter through media, prevenKng low flow bypass.8. REM TRITON filter cartridges are removable for ease of cleaning and maintenance. <br />9. Filter designs include a high flow overflow bypass to eliminate pooling or flooding during heavy rain events.10. See our Specifier Sheet for sizes, models and flow rate informaKon.11. Maintenance informaKon and replacement REM Media Packs are available upon request by contacKng REM at sales@remfilters.com or (888) 526-4736. <br />12. U.S. Patent Number: 6,217,757 B1 <br />13. Made in the USA. <br />1 <br />1 <br />2 <br />3 <br />4 <br />5 <br />ITEM NO.DESCRIPTION QTY. <br />1 FILTER COVER 2 <br />2 FILTER MEDIA PACK 1 <br />3 FILTER CAGE 1 <br />4 FILTER ASSY BASE 1 <br />5 SUPPORT STRUCTURE 1 <br />D <br />C <br />B <br />A A <br />B <br />C <br />D <br />8 7 6 5 4 3 2 1 <br />8 7 6 5 4 3 2 1 <br />E <br />F <br />E <br />F <br />RE <br />V <br />D <br />To <br />p <br />H <br />a <br />t <br />01-004 <br />SHEET 1 OF 3 <br />A.C.2/24/14 <br />UNLESS OTHERWISE SPECIFIED: <br />SCALE: 1:3WEIGHT: <br />DWG. NO.REVDSIZE <br />TITLE: <br />NAME DATE <br />COMMENTS: <br />Q.A. <br />MFG APPR. <br />ENG APPR. <br />CHECKED <br />DRAWN <br />FINISH <br />MATERIAL <br />INTERPRET ALL GEOMETRICTOLERANCING PER: 0.05 <br />DIMENSIONS ARE IN INCHES <br />TOLERANCES:FRACTIONAL <br />ANGULAR: MACH BEND <br />ONE PLACE DECIMAL 0.2 <br />TWO PLACE DECIMAL 0.1 <br />APPLICATION <br />NEXT ASSY USED ON <br />PROPRIETARY AND CONFIDENTIAL <br />THE INFORMATION CONTAINED IN THIS <br />DRAWING IS THE SOLE PROPERTY OF<INSERT COMPANY NAME HERE>. ANY <br />REPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OF <br /><INSERT COMPANY NAME HERE> ISPROHIBITED. <br />A <br />A <br />TOP HAT FILTER <br />HYDRAULIC DATALEGEND
The URL can be used to link to this page
Your browser does not support the video tag.