POWER LEGEND AND SYMBOLS <br />SYMBOL DESCRIPTION <br />POWER LEGEND AND SYMBOLS <br />SYMBOL DESCRIPTION <br />NOTE TO CONTRACTOR <br />CONTRACTOR SHALL VERIFY PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL <br />IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE <br />RESPONSIBLE FOR THE SAME. <br />DO NOT SCALE DRAWINGS <br />1.ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE LATEST CODE OF FEDERAL REGULATIONS (CFR), NATIONAL ELECTRICAL CODE EDITION AND ALL APPLICABLE LOCAL CODES AND <br />REGULATIONS. <br />2.ALL WORK IS NEW UNLESS NOTED OTHERWISE. <br />3.ALL PANELS, SWITCHES, ETC. SHALL HAVE SUFFICIENT GUTTER SPACE AND LUGS IN COMPLIANCE TO UL REQUIREMENTS TO ACCOMMODATE CONDUCTORS SHOWN. <br />4.WHERE WIRE SIZES ARE INDICATED ON PLANS, FOR INDIVIDUAL CIRCUITS, THE WIRE SIZE INDICATED SHALL APPLY TO THE COMPLETE CIRCUIT, UNLESS OTHERWISE NOTED. <br />5.WHERE EXISTING CIRCUITS OR DEVICES ARE DEMOLISHED, MODIFIED, OR REUSED, ENSURE ALL EXISTING ELECTRICAL UTILIZATION DEVICES TO REMAIN ARE ENERGIZED UPON COMPLETION OF WORK. <br />6.CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF MECHANICAL, PLUMBING AND OTHER EQUIPMENT REQUIRING ELECTRICAL CONNECTION PRIOR TO ANY WORK. <br />7.CONTRACTOR SHALL EXTEND WIRING FROM ALL JUNCTION BOXES, SWITCHES, ETC. AND MAKE FINAL CONNECTION AS REQUIRED TO ALL BUILDING EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS. <br />8.DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS AND WORK INCLUDED. FOLLOW DRAWINGS IN LAYING OUT WORK AND CHECK DRAWINGS OR OTHER TRADES <br />RELATING TO WORK TO VERIFY SPACE IN WHICH WORK WILL BE INSTALLED. MAINTAIN HEADROOM AND MINIMUM CODE REQUIRED WORKING CLEARANCES AT ALL TIMES. <br />9.CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL WALL OUTLET BOXES FOR SWITCHES, BELL/STROBES, FIRE ALARM PULL STATIONS. RECEPTACLES ETC. WITH CABINETS, FURNITURE, EQUIPMENT <br />ETC., TO AVOID CONFLICT. <br />10.FURNISH PULL STRING IN EACH RACEWAY RUN OVER 10' IN LENGTH, IN WHICH PERMANENT WIRING IS NOT INSTALLED. <br />11.NOT MORE THAN THREE LIGHTING OR CONVENIENCE OUTLET CIRCUITS ARE PERMITTED IN ONE CONDUIT, PROVIDE SEPARATE CONDUIT FOR EACH HOMERUN INDICATED ON THE DRAWING, UNLESS <br />INDICATED OTHERWISE. <br />12.PROVIDE PULL BOXES WHEREVER NECESSARY TO FACILITATE PULLING OF CONDUCTORS. COORDINATE LOCATIONS OF BOXES WITH OTHER TRADES TO AVOID CONFLICT. PULL BOXES SHALL BE <br />ACCESSIBLE. THE SIZE OF PULL BOX SHALL COMPLY WITH N.E.C. REQUIREMENTS. <br />13.ALL EXTERIOR ELECTRICAL DEVICES AND EQUIPMENT INCLUDING THOSE THAT ARE EXPOSED TO OUTSIDE ENVIRONMENT SHALL BE WEATHERPROOF TYPE, NEMA 3R AND ELECTRICAL DEVICES AND <br />EQUIPMENT INCLUDING THOSE THAT ARE EXPOSED TO DIRECT WATER SPRAY OR IN CORROSIVE LOCATIONS SHALL BE NEMA 4X, REGARDLESS OF ALTERNATE NEMA RATING INDICATED IN NOTES OR <br />SCHEDULES. <br />14.NO CONDUIT RUNS SHALL BE ALLOWED IN CONCRETE SLABS. ALL CONDUITS WILL BE PLACED ABOVE ACCESSIBLE CEILING SPACES UNLESS SPECIFICALLY INDICATED TO BE UNDERGROUND. <br />15.LIGHTING, POWER, TELEPHONE AND COMMUNICATIONS OUTLETS SHALL NOT BE PLACED BACK-TO-BACK. <br />16.DISCONNECT SWITCHES SHALL BE MOUNTED ON INDIVIDUAL SUPPORTS, OR OTHERWISE DIRECTLY ON EQUIPMENT, PROVIDED NO MODIFICATION TO EQUIPMENT IS NECESSARY. <br />17.ALL ELECTRICAL POWER, LIGHTING, TELEPHONE OR SIGNAL WIRING IN FIRE RATED WALL IS TO BE INSTALLED IN A METALLIC CONDUIT SYSTEM. <br />18.ALL ELECTRIC MATERIAL SHALL BE LISTED BY "UL" FOR THE TYPE OF APPLICATION AND "UL" LABEL SHALL APPEAR ON ALL ELECTRICAL EQUIPMENT. <br />19.ALL DISTRIBUTION AND CONTROL EQUIPMENT (SUCH AS CB's, SWITCHES, CONTACTORS, ETC.), TERMINATIONS SHALL BE FULLY RATED PER UL AS FOLLOWS: <br />a. 100A OR LESS : 60°C OR MORE; <br />b. MORE THAN 100A : 75°C OR MORE. <br />20.ANY ERRORS, OMISSIONS, OR DESIGN DISCREPANCIES ON PLANS OR SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ELECTRICAL ENGINEER FOR CLARIFICATION OR CORRECTION PRIOR <br />TO CONSTRUCTION AND PREPARATION OF SUBMITTAL PACKAGES. <br />21.CONDUCTORS SHALL HAVE UNDERWRITER'S LABORATORIES, INC.(UL) LISTED, 600 VOLT INSULATION OF TYPE SPECIFIED BELOW OR ELSEWHERE IN THE SPECIFICATIONS. CONDUCTORS SHALL BE <br />COPPER AND LISTED FOR 90 DEGREE APPLICATIONS. <br />1. BRANCH CIRCUITS - LIGHTING AND POWER. <br />a. #10 AWG AND SMALLER, SOLID WIRE TYPE THW OR THHN/THWN-2, THHW(THHN FOR DRY LOCATION ONLY). <br />b. #8 AWG TO #2 AWG, STRANDED TYPE THW OR THHN/THHW. <br />c. #1 AWG AND LARGER, STRANDED TYPE XHHW-2. <br />2. FEEDERS : TYPE THW OR THHN/THWN-2, OR XHHW-2. <br />22.PROVIDE GREEN INSULATED GROUNDING CONDUCTOR IN EACH RACEWAY INCLUDING CONDUITS, PLUG STRIPS, WIREMOLD. SIZE OF GROUNDING SHALL BE IN ACCORDANCE WITH NATIONAL ELECTRIC <br />CODE ARTICLE 250. <br />23.WIRING METHOD SHALL BE EMT ABOVE GROUND AND MOUNTED IN CONCEALED SPACES AND SCHEDULE-40 PVC FOR UNDERGROUND INSTALLATION. USE RIGID WHEN ENCASED IN CONCRETE OR <br />SUSCEPTIBLE TO DAMAGE. <br />24.UNLESS OTHERWISE INDICATED, SHARING OF NEUTRAL/GROUNDED CONDUCTORS AMONG SINGLE PHASE BRANCH CIRCUITS OF DIFFERENT PHASES INSTALLED IN THE SAME RACEWAY IS NOT PERMITTED. <br />PROVIDE DEDICATED NEUTRAL/GROUNDED CONDUCTOR FOR EACH INDIVIDUAL BRANCH CIRCUIT. <br />25.UNLESS OTHERWISE INDICATED, PROVIDE A SEPARATE SWITCHED AND UNSWITCHED PHASE CONDUCTOR TO ALL CONTROLLED RECEPTACLES REGARDLESS OF RECEPTACLE CONFIGURATION. <br />26.BASIS OF ELECTRICAL DESIGN LIMITS VOLTAGE DROP TO 2% FOR FEEDERS AND 3% FOR BRANCH CIRCUITS. ANY CHANGES MADE IN THE FIELD SHALL LIMIT VOLTAGE DROP TO THESE PERCENTAGES. <br />27.BRANCH CIRCUIT CONDUITS SHALL BE CONCEALED IN WALL OR CEILING SPACES. EXPOSED CONDUITS ARE NOT ALLOWED WHERE CONCEALED METHODS ARE AVAILABLE. <br />28.CONTRACTOR SHALL PROVIDE CONDUCTORS AND CONDUITS REQUIRED FOR ALL BRANCH CIRCUITS AND FEEDERS. FOR CIRCUIT SIZES NOT SHOWN, REFER TO PANEL SCHEDULES FOR CONDUCTOR AND <br />CONDUIT SIZES. <br />29.THE CONTRACTOR SHALL COORDINATE THE WORK WITH OTHER TRADES. ANY COSTS TO INSTALL WORK TO ACCOMPLISH SAID COORDINATION, WHICH DIFFERS FROM THE WORK AS SHOWN ON THE <br />CONTRACT DOCUMENTS, SHALL BE INCURRED BY THE CONTRACTOR. ANY DISCREPANCIES, AMBIGUITIES OR CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE <br />DURING BID TIME FOR CLARIFICATION. ANY SUCH CONFLICTS NOT CLARIFIED PRIOR TO BID SHALL BE SUBJECT TO THE INTERRUPTION OF THE OWNER'S REPRESENTATIVE AT NO ADDITIONAL COST TO THE <br />OWNER. <br />30.ALL 125 AND 250-VOLT, 15- AND 20-AMPERE NONLOCKING TYPE RECEPTACLES SHALL BE LISTED TAMPER RESISTANT RECEPTACLES IN AREAS SPECIFIED IN NEC 406.12. <br />31.ALL 125-VOLT THROUGH 250-VOLT RECEPTACLES SUPPLIED BY SINGLE-PHASE BRANCH CIRCUITS RATED 150 VOLTS OR LESS TO GROUND, 50 AMPERES OR LESS, AND ALL RECEPTACLES SUPPLIED BY <br />THREE-PHASE BRANCH CIRCUITS RATED 150 VOLTS OR LESS TO GROUND, 100 AMPERES OR LESS, INSTALLED IN THE LOCATIONS SPECIFIED BELOW SHALL HAVE GROUND-FAULT CIRCUIT-INTERRUPTER <br />PROTECTION FOR PERSONNEL AND ANY OTHER AREAS SPECIFIED IN NEC 210.8 <br />a.OUTDOORS <br />APPLICABLE CODES <br />ABBREVIATIONSGENERAL NOTES <br />1.2022 BUILDING STANDARDS ADMINISTRATIVE CODE, PART 1, TITLE 24 C.C.R. <br />2.2022 CALIFORNIA BUILDING CODE (CBC),PART 2, TITLE 24 C.C.R. (IBC WITH AMENDMENTS) <br />3.2022 CALIFORNIA ELECTRICAL CODE (CEC), PART 3, TITLE 24 C.C.R. (NEC WITH AMENDMENTS) <br />4.2022 CALIFORNIA MECHANICAL CODE (CMC), PART 4, TITLE 24 C.C.R. (UMC WITH AMENDMENTS) <br />5.2022 CALIFORNIA PLUMBING CODE (CPC), PART 5, TITLE 24 C.C.R. (UPC WITH AMENDMENTS) <br />6.2022 CALIFORNIA FIRE CODE, PART 9, TITLE 24 C.C.R. (IFC WITH AMENDMENTS) <br />7.2022 CALIFORNIA REFERENCED STANDARDS, PART 12, TITLE 24 C.C.R. <br />8.TITLE 19 C.C.R., PUBLIC SAFETY, STATE FIRE MARSHAL REGULATIONS. <br />9.2022 CALIFORNIA ENERGY CODE (PART 6, TITLE 24 C.C.R.) <br />10.2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBSG), PART 11, TITLE 24 C.C.R. <br />+96" OR 7'-6" AFF <br />MOUNTING HEIGHT FROM FINISHED FLOOR TO BOTTOM LINE OF OUTLET OR EQUIPMENT. FOR <br />LIGHT FIXTURES, IT IS TO BOTTOM OF FIXTURE. <br />MAIN SWITCHBOARD, POWER OR LIGHT, FLOOR STANDING ENCLOSURE, (SEE SINGLE LINE <br />DIAGRAM AND LOAD SUMMARY) <br />BRANCH PANELBOARD, WALL MOUNTED, SEE PLANS AND SCHEDULE. (RECESSED MOUNTED) <br />BRANCH PANELBOARD, WALL MOUNTED, SEE PLANS AND SCHEDULE. (SURFACE MOUNTED) <br />CONDUIT STUBBED AND CAPPED, SIZE AND QUANTITIES PER PLANS. <br />CONDUIT CONCEALED IN OR UNDER FLOOR, 3/4" UON, COORDINATE WITH G.C.: OR, BURIAL <br />CONDUIT UNDERGROUND. REFER TO PLANS, DETAILS AND SPECIFICATIONS. <br />SPECIALTY OUTLET. VERIFY NEMA CONFIGURATION AS NOTED ON PLANS.L5-30R <br />HEAVY DUTY SAFETY SWITCH H.P. AND 600 VOLTS RATED. "F" INDICATES FUSE TYPE. FUSES <br />PER APPROVED EQUIPMENT MANUFACTURERS SHOP DRAWINGS. SUBSCRIPT INDICATES <br />SWITCH AMPERE RATING. # OF POLES TO MATCH SUPPLY CIRCUIT. <br />MAGNETIC MOTOR STARTER H.P. RATED (NUMBER INDICATES NEMA SIZE)#2 <br />OR <br />200-Y CONDUIT WIRING DESCRIPTION PER FEEDER SCHEDULE ON OTHER PLAN <br />ELECTRICAL UTILITY PRIMARY <br />ELECTRICAL UTILITY SECONDARY <br />CONCRETE ELECTRICAL PULL BOX WITH LID APPROPRIATE FOR INSTALLATION LOCATION. LID <br />SHALL BE LABELED "ELECTRICAL" OR "COMM" ACCORDING TO USE. <br />EQUIPMENT <br />ID. No. <br />SHEET No. <br />DETAIL No. <br />EQUIPMENT REFERENCE <br />DETAIL REFERENCE <br />ABOVE CEILING, CONCEALED, JUNCTION BOX, WITH COVER, PER NATIONAL ELECTRICAL CODE <br />(NEC) TABLE 314.16(A)/(B), 4" SQUARE DEEP, WITH PLASTER RING. <br />RECESSED WALL MOUNTED JUNCTION BOX, WITH COVER, PER NATIONAL ELECTRICAL CODE <br />(NEC) TABLE 314.16(A)/(B), 4" SQUARE DEEP, WITH PLASTER RING. <br />DUPLEX RECEPTACLE OUTLET, CONVENIENCE. (20 AMPS, 125 VOLTS, GFCI TYPE) WITH <br />MOUNTING HEIGHT HORIZONTALLY ABOVE COUNTER TOP PER ARCHITECTURAL PLANS OR <br />APPROVAL. <br />DOUBLE DUPLEX RECEPTACLE OUTLET, CONVENIENCE. (20 AMPS, 125 VOLTS) MOUNTED +15" <br />A.F.F. TO BOTTOM OF DEVICE U.O.N. <br />DUPLEX RECEPTACLE OUTLET, CONVENIENCE. (20 AMPS, 125 VOLTS, GFCI TYPE) MOUNTED +15" <br />A.F.F. TO BOTTOM OF DEVICE U.O.N. <br />DUPLEX RECEPTACLE OUTLET, CONVENIENCE. (20 AMPS, 125 VOLTS) MOUNTED +15" A.F.F. TO <br />BOTTOM OF DEVICE U.O.N. <br />WEATHERPROOF DUPLEX RECEPTACLE OUTLET, CONVENIENCE. (20 AMPS, 125 VOLTS) <br />MOUNTED +15" A.F.F. TO BOTTOM OF DEVICE U.O.N. <br />MOLDED CASE CIRCUIT BREAKER <br />SWITCH AND FUSE ASSEMBLY <br />GROUNDING CONNECTION AT SWITCHGEAR/DISTRIBUTION BOARD WITH NEUTRAL BONDING. <br />UTILITY COMPANY PULL SECTION LUGS <br />G <br />N <br />GROUNDING CONNECTION TO MAIN BUILDING GROUND SYSTEM U.O.N. <br />EXISTING (DASH INDICATES) ELECTRICAL EQUIPMENT <br />TELEPHONE BACKBOARD 2'X4'X3/4" PLYWOOD. PROVIDE 2" CONDUIT TO TELEPHONE POC. <br />HOMERUN TO CIRCUITS #1 AND #3 IN PANEL "A". REFER TO PANEL SCHEDULE <br />FOR CONDUIT AND CONDUCTOR SIZES. QTY AS REQUIRED. <br />A-1,3 <br />SMOKE FIRE DAMPER <br />IN-LINE UTILITY COMPANY METER <br />UTILITY METER WITH CIRCUIT TRANSFORMERS (CT'S) METER <br />WP <br />GROUND WELL <br />A AMPERE <br />AF AMPERE FRAME RATING (CIRCUIT BREAKER) <br />AFC AVAILABLE FAULT CURRENT <br />AFF ABOVE FINISHED FLOOR <br />AFG ABOVE FINISHED GRADE <br />AFU AMPERE FUSE RATING (FUSE) <br />AIC AMPERE INTERRUPTING CAPACITY <br />AS AMPERE SWITCH RATING (FUSE) <br />AT AMPERE TRIP RATING (CIRCUIT BREAKER) <br />AWG AMERICAN WIRE GAUGE <br />BCG BARE COPPER GROUND <br />BKBD BACKBOARD <br />BLDG BUILDING <br />BKR BREAKER <br />C CONDUIT <br />CB CIRCUIT BREAKER <br />CKT CIRCUIT <br />CFSD COMBINATION FIRE SMOKE DAMPER <br />CO CONDUIT ONLY <br />CT CURRENT TRANSFORMER <br />CU COPPER <br />CL CENTERLINE <br />DISC DISCONNECT <br />DSBN DISTRIBUTION SECTION <br />DN DOWN <br />DWG DRAWING <br />EA EACH <br />EC ELECTRICAL CONTRACTOR <br />EGC EQUIPMENT GROUNDING CONDUCTOR <br />EM EMERGENCY <br />EMT ELECTRICAL METALLIC TUBING <br />EPO EMERGENCY POWER OFF <br />EXIST, (E)EXISTING <br />EXO EXTERNAL OPERABLE DISCONNECT <br />F FUSE <br />FA FIRE ALARM <br />FACP FIRE ALARM CONTROL PANEL <br />FF FINISHED FLOOR <br />FG FINISHED GRADE <br />FLA FULL LOAD CURRENT <br />GEC GROUNDING ELECTRODE CONDUCTOR <br />GEN GENERATOR <br />GFCI GROUND FAULT CIRCUIT INTERRUPTER <br />GFP GROUND FAULT PROTECTION <br />GND GROUND <br />GRC GALVANIZED RIGID CONDUIT <br />HD HEAVY DUTY <br />HOA HAND-OFF-AUTOMATIC <br />HP HORSE POWER <br />HV HIGH VOLTAGE <br />IDF INTERMEDIATE DISTRIBUTION FRAME <br />IG ISOLATED/INSULATED GROUND <br />ISC SHORT CIRCUIT CURRENT AVAILABLE IN RMS <br />SYMMETRICAL AMPERES <br />J-BOX JUNCTION BOX <br />KCMIL THOUSAND CIRCULAR MILS <br />KW KILOWATT <br />KV KILO VOLT <br />KVA KILO VOLT-AMPERE <br />LDC LOCAL DISTRIBUTION CABINET <br />LDF LOCAL DISTRIBUTION FRAME <br />LCL LONG CONTINUOUS LOAD <br />LFMC LIQUID TIGHT FLEXIBLE METAL CONDUIT <br />LSIG LONG, SHORT, INSTANTANEOUS, GROUND <br />LTG LIGHTING <br />LV LOW VOLTAGE <br />MFR MANUFACTURER <br />MAX MAXIMUM <br />MCC MOTOR CONTROL CENTER <br />MIN MINIMUM <br />MH MANHOLE / METAL HALIDE <br />MLO MAIN LUGS ONLY <br />M/M METER AND MAIN SECTION <br />MV MEDIUM VOLTAGE <br />NC NORMALLY CLOSED <br />NEC NATIONAL ELECTRICAL CODE <br />NEMA NATIONAL ELECTRICAL MANUFACTURER'S <br />ASSOCIATION <br />NEW (N)NEW, TO BE FURNISHED AND INSTALLED BY <br />CONTRACTOR <br />NF NON-FUSED <br />NIC NOT IN CONTRACT <br />N/L NIGHT LIGHT <br />NO NUMBER, NORMALLY OPEN <br />NTS NOT TO SCALE <br />OC ON CENTER <br />OD OUTSIDE DIAMETER <br />P POLE <br />PB PULL BOX <br />PF POWER FACTOR <br />PH PHASE <br />PNL PANEL <br />POC POINT OF CONNECTION <br />PP POWER POLE <br />PWR POWER <br />PVC POLYVINYL CHLORIDE <br />QUAD QUADRUPLEX <br />QTY QUANTITY <br />RGS RIGID GALVANIZED STEEL <br />RMC RIGID METALLIC CONDUIT <br />RM ROOM <br />RNC RIGID NONMETALLIC CONDUIT <br />SHT SHEET <br />SN SOLID NEUTRAL <br />SPEC SPECIFICATIONS <br />SW SWITCH <br />SWBD SWITCHBOARD <br />TC TIME CLOCK <br />TEL TELEPHONE <br />TERM TERMINAL <br />TP TEMPORARY POLE <br />TYP TYPICAL <br />UGPS UNDERGROUND PULL SECTION <br />UL UNDERWRITERS LABORATORY <br />UPS UNINTERRUPTIBLE POWER SUPPLY <br />UON UNLESS OTHERWISE NOTED <br />V VOLT, VOLTAGE <br />VA VOLT-AMPERE <br />VD VOLTAGE DROP <br />VFC VARIABLE FREQUENCY CONTROLLER <br />VFD VARIABLE FREQUENCY DRIVE <br />W WATT <br />WH WATT-HOUR <br />WP WEATHERPROOF <br />WW WIREWAY <br />XP EXPLOSION PROOF <br />Z IMPEDANCE <br />4W FOUR-WIRE <br />3W THREE-WIRE <br />5S JUNCTION BOX <br />(4 11/16" SQUARED X2 1/8" DEEP) <br />Ø DIAMETER, PHASE <br />#NUMBER <br />°C DEGREE CELSIUS <br />(E)EXISTING DEVICE TO REMAIN <br />(R)REMOVE EXISTING DEVICE AND ASSOCIATED <br />CONDUIT AND WIRE <br />(RL)REMOVE EXISTING DEVICE AND RELOCATE AS <br />SHOWN ON PLAN <br />(NL)NEW LOCATION OF RELOCATED DEVICE <br />SUBSCRIPT "A-1" REFERS TO PANEL DESIGNATION WITH CIRCUIT NUMBER. TYPICAL OF ALL <br />RECEPTACLE OUTLETS.A-1 <br />100AS <br />NUMBER DATE INITIALS DESCRIPTION <br />PREPARED UNDER THE <br />SUPERVISION OF: <br />CITY OF SANTA ANA <br />FILE NO.: <br />INSTALLEDAPPROVED <br />CONSTRUCTION COMPLETED: <br />BENCHMARK NO.: SA-253-70 <br />RECOMMENDED FOR <br />CONSTRUCTION: <br />REFERENCES <br />PUBLIC WORKS AGENCY <br />RCE NO.: <br />ELEV.: 176.00 (2010) <br />REVISIONS <br />SHEET OF <br />BENCHMARK DESCRIPTION: <br />OCS BM SA-253-70 <br />FD 3 3/4" OCS ALUMINUM BENCH MARK DISK STAMPED "SA-253-70", SET IN NW'LY CORNER OF A 3.5FT X 16FT <br />CONCRETE CATCH BASIN. MONUMENT IS LOCATED IN THE NE'LY CORNER OF THE INTERSECTION OF GRAND AVE <br />AND SANTA CLARA AVE, 87FT N'LY OF THE CENTERLINE OF SANTA CLARA AVE AND 39FT E'LY OF THE CENTERLINE <br />OF GRAND AVE. MONUMENT IS SET LEVEL WITH THE SIDEWALK <br />PORTOLA PARK <br />SPLASH PADREVIEWED FOR <br />CONSTRUCTABLITY: <br />PRINCIPAL CIVIL ENGINEER <br />DESIGNED: <br />PRINCIPAL CIVIL ENGINEER RCE NO.: <br />LM MR BK <br />ELECTRICAL ENGINEER <br />DRAWN:CHECKED: <br />PS- <br />2 <br />5 <br />- <br />2 <br />4 <br />0 <br />1 <br />BRADEN KEMPTON <br />1700 E. SANTA CLARA AVENUE, SANTA ANA, CA 92705 <br />811 <br />UNDERGROUND SERVICE ALERT. DIAL 811 <br />LOCATION OF UNDERGROUND UTILITIES BY CONTRACTING <br />BEFORE EXCAVATING, THE CONTRACTOR SHALL VERIFY THE <br />DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICE. <br />UNDERGROUND FACILITIES PRIOR TO DOING WORK THAT MAY <br />STEPS TO ASCERTAIN THE EXACT LOCATION OF ALL <br />THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE <br />DIFFERENT FROM THAT WHICH IS SHOWN ON THE PLANS OR IN <br />UNDERGROUND FACILITIES NOT KNOWN OR IN A LOCATION <br />ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF <br />UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA <br />\\ <br />E <br />G <br />N <br />Y <br />T <br />E <br />D <br />R <br />I <br />V <br />E <br />\ <br />D <br />W <br />E <br />\ <br />_ <br />P <br />R <br />O <br />J <br />E <br />C <br />T <br />\ <br />2 <br />0 <br />2 <br />4 <br />\ <br />2 <br />4 <br />- <br />3 <br />0 <br />5 <br /> <br />P <br />O <br />R <br />T <br />O <br />L <br />A <br /> <br />P <br />A <br />R <br />K <br />\ <br />_ <br />C <br />A <br />D <br />\ <br />2 <br />4 <br />- <br />3 <br />0 <br />5 <br /> <br />E <br />- <br />F <br />R <br />O <br />N <br />T <br /> - <br /> <br />20 <br />2 <br />5 <br />- <br />1 <br />1 <br />- <br />2 <br />4 <br /> - <br /> <br />LU <br />I <br />S <br /> <br />M <br />U <br />N <br />G <br />U <br />I <br />A <br />24-305 <br />DESIGN WEST ENGINEERING <br />MECHANICAL ELECTRICAL ENERGY CONSULTANTS <br />San Bernardino, CA 92408 <br />412 E. Vanderbilt Way <br />Phone: 909.890.3700 <br />Fax: 909.890.3770 <br />Email: cadd@designwesteng.com <br />PO <br />R <br />T <br />O <br />L <br />A <br /> <br />P <br />A <br />R <br />K <br /> <br />S <br />P <br />L <br />A <br />S <br />H <br /> <br />P <br />A <br />D <br /> <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />O <br />. <br /> <br />2 <br />5 <br />- <br />2 <br />4 <br />0 <br />1 <br />E-0.1 <br />SHEET INDEX <br />Sheet Number Sheet Title <br />E-0.1 ELECTRICAL LEGEND & NOTES <br />E-0.3 SINGLE LINE DIAGRAM <br />E-1.1 ELECTRICAL SITE PLAN <br />E-2.1 ELECTRICAL DETAILS <br />E-0.1ELECTRICAL LEGEND & NOTES <br />24 57 <br />SIGNED:11/24/2025 <br />24 57