Laserfiche WebLink
POWER SYMBOLS ABBREVIATIONS <br />1.2022 BUILDING STANDARDS ADMINISTRATIVE CODE, PART 1, TITLE 24 C.C.R. <br />2.2022 CALIFORNIA BUILDING CODE (CBC),PART 2, TITLE 24 C.C.R. (IBC WITH AMENDMENTS) <br />3.2022 CALIFORNIA ELECTRICAL CODE (CEC), PART 3, TITLE 24 C.C.R. (NEC WITH AMENDMENTS) <br />4.2022 CALIFORNIA MECHANICAL CODE (CMC), PART 4, TITLE 24 C.C.R. (UMC WITH AMENDMENTS) <br />5.2022 CALIFORNIA PLUMBING CODE (CPC), PART 5, TITLE 24 C.C.R. (UPC WITH AMENDMENTS) <br />6.2022 CALIFORNIA FIRE CODE, PART 9, TITLE 24 C.C.R. (IFC WITH AMENDMENTS) <br />7.2022 CALIFORNIA REFERENCED STANDARDS, PART 12, TITLE 24 C.C.R. <br />8.2022 TITLE 19 C.C.R., PUBLIC SAFETY, STATE FIRE MARSHAL REGULATIONS. <br />9.2022 CALIFORNIA ENERGY CODE (PART 6, TITLE 24 C.C.R.) <br />10.2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBSG), PART 11, TITLE 24 C.C.R. <br />SURFACE MOUNTED DOUBLE FACE EXIT SIGN (UNIVERSAL ARROWS INDICATED AS NEEDED) <br />SWITCH, SINGLE POLE 20A. MOUNTED 48" A.F.F. TO TOP OF DEVICE. SUBSCRIPTS INDICATE THE <br />FOLLOWING: <br />M - MOTOR RATED K - KEY OPERATED <br />3 - THREE WAY D - DIMMER SWITCH <br />4 - FOUR WAY T - TIMED SWITCH <br />a, b, c, ETC. - DESIGNATES SWITCH-LEGS CONTROLLED AND QUANTITY OF SWITCHES AT EACH <br />LOCATION. <br />SURFACE MOUNTED SINGLE FACE EXIT SIGN (UNIVERSAL ARROWS INDICATED AS NEEDED) <br />2'X4' RECESSED LUMINAIRE WITH 90MIN. EMERGENCY BATTERY BACKUP <br />2'X4' RECESSED LUMINAIRE. FN INDICATES LUMINAIRE TYPE - REFER TO LUMINAIRE SCHEDULE, <br />TYPICAL. SUBSCRIPT 2ab REFERS TO CIRCUIT AND SWITCH LEG 'a' AND 'b'. SUBSCRIPT N/L <br />REFERS TO UNSWITCHED LEG. <br />OCCUPANCY SENSOR, DUAL-TECHNOLOGY, SURFACE CEILING MOUNTED. PROVIDE WITH POWER <br />PACK(S) AS REQUIRED. <br />DUAL TECHNOLOGY OCCUPANCY SENSOR, SURFACE WALL MOUNTED 180° U.O.N. <br />LOW-VOLTAGE OVERRIDE SWITCH. NUMBER INDICATES OVERRIDE SWITCH. A,B,C, ETC. <br />DESIGNATES ZONE AS SHOWN ON LIGHTING ZONE SCHEDULE. <br />CEILING MOUNTED DIGITAL ROOM CONTROLLER INTERCONNECTED TO NETWORK LIGHTING CONTROLS. <br />LOW-VOLTAGE DIMMER SWITCH. MOUNTED 48" A.F.F. TO TOP OF DEVICE. a, b, c, ETC. - <br />DESIGNATES SWITCH-LEGS CONTROLLED AND QUANTITY OF SWITCHES AT EACH LOCATION. <br />LOW-VOLTAGE OCCUPANCY SENSOR, DUAL-TECHNOLOGY, SURFACE CEILING MOUNTED <br />INTERCONNECTED TO NETWORK LIGHTING CONTROLS. <br />FN <br />AB <br />N/L <br />FNE <br />MAIN SWITCHBOARD, POWER OR LIGHT, FLOOR STANDING ENCLOSURE, (SEE SINGLE LINE <br />DIAGRAM AND LOAD SUMMARY) <br />ELECTRICAL PANEL, RECESSED OR SURFACE MOUNTED <br />BRANCH PANELBOARD OR SWITCHGEAR, REFERENCE SINGLE LINE DIAGRAM FOR ADDITIONAL <br />INFORMATION. <br />CONDUIT CONCEALED IN OR UNDER FLOOR, 3/4" UON, COORDINATE WITH G.C.: OR, BURIAL <br />CONDUIT UNDERGROUND IN SCHEDULE - 40 PVC UNLESS NOTED OTHERWISE. VERIFY DEPTH <br />AND TRENCHING WITH G.C. <br />SPECIALTY OUTLET. VERIFY NEMA CONFIGURATION AS NOTED ON PLANS.L5-30R <br />DISCONNECT SWITCH H.P. RATED 600 VOLTS RATED. "F" INDICATES FUSE TYPE. FUSES PER <br />APPROVED MANUFACTURERS SHOP DRAWINGS. <br />MAGNETIC MOTOR STARTER H.P. RATED (NUMBER INDICATES NEMA SIZE)#2 <br />CONCRETE ELECTRICAL PULL BOX WITH LID APPROPRIATE FOR INSTALLATION LOCATION. LID <br />SHALL BE LABELED "ELECTRICAL" OR "COMM" ACCORDING TO USE. <br />EQUIPMENT <br />ID. No. <br />SHEET No. <br />DETAIL No. <br />EQUIPMENT REFERENCE <br />DETAIL REFERENCE <br />ABOVE CEILING, CONCEALED, JUNCTION BOX, WITH COVER, PER NATIONAL ELECTRICAL CODE <br />(NEC) TABLE 314.16(A)/(B), 4" SQUARE DEEP, WITH PLASTER RING. <br />DOUBLE DUPLEX RECEPTACLE, FLUSH IN FLOOR, WATERTIGHT JUNCTION BOX (20 AMP, 120 <br />VOLT, 2-POLE, 3-WIRE) U.O.N. <br />DUPLEX RECEPTACLE, FLUSH IN FLOOR, WATERTIGHT JUNCTION BOX (HINGED BRASS COVER: <br />20 AMP, 120 VOLT, 2-POLE, 3-WIRE) U.O.N. <br />JUNCTION BOX, FLUSH IN FLOOR, WATERTIGHT (HINGED BRASS COVER: 20 AMP, 120 VOLT, <br />2-POLE, 3-WIRE) U.O.N. <br />RECESSED WALL MOUNTED JUNCTION BOX, WITH COVER, PER NATIONAL ELECTRICAL CODE <br />(NEC) TABLE 314.16(A)/(B), 4" SQUARE DEEP, WITH PLASTER RING. <br />RECESSED CEILING MOUNTED DUPLEX RECEPTACLE OUTLET, CONVENIENCE. (20 AMPS, 125 <br />VOLTS) U.O.N. <br />DUPLEX RECEPTACLE OUTLET, CONVENIENCE. (20 AMPS, 125 VOLTS) WITH MOUNTING HEIGHT <br />HORIZONTALLY ABOVE COUNTER TOP PER ARCHITECTURAL PLANS OR APPROVAL. <br />DUPLEX RECEPTACLE OUTLET, CONVENIENCE. (20 AMPS, 125 VOLTS, GFCI TYPE) WITH <br />MOUNTING HEIGHT HORIZONTALLY ABOVE COUNTER TOP PER ARCHITECTURAL PLANS OR <br />APPROVAL. <br />DUPLEX RECEPTACLE OUTLET, SINGLE SPLIT-CIRCUIT SWITCHED. (20 AMPS, 125 VOLTS) <br />MOUNTED +15" A.F.F. TO BOTTOM OF DEVICE U.O.N. <br />DOUBLE DUPLEX RECEPTACLE, WALL MOUNTED. (20 AMPS, 120 VOLTS) MOUNTED +15" A.F.F. TO <br />BOTTOM OF DEVICE U.O.N. <br />DUPLEX RECEPTACLE OUTLET, CONVENIENCE. (20 AMPS, 125 VOLTS, GFCI TYPE) MOUNTED +15" <br />A.F.F. TO BOTTOM OF DEVICE U.O.N. <br />DUPLEX RECEPTACLE, WALL MOUNTED. (20 AMPS, 120VOLTS) MOUNTED +15" A.F.F. TO BOTTOM <br />OF DEVICE U.O.N. <br />MOLDED CASE CIRCUIT BREAKER <br />SWITCH AND FUSE ASSEMBLY <br />GROUNDING CONNECTION AT SWITCHGEAR/DISTRIBUTION BOARD WITH NEUTRAL BONDING. <br />UTILITY COMPANY PULL SECTION LUGS <br />G <br />N <br />GROUNDING CONNECTION TO MAIN BUILDING GROUND SYSTEM U.O.N. <br />SMOKE FIRE DAMPER <br />DUCT MOUNTED SMOKE DETECTOR. <br />IN-LINE UTILITY COMPANY METER <br />UTILITY METER WITH CIRCUIT TRANSFORMERS (CT'S) METER <br />TRANSFORMER WITH SECONDARY GROUNDOR <br />GROUND FAULT PROTECTION DEVICE CONNECTED TO THE POWER DISTRIBUTION SYSTEM <br />THERMOSTAT SUPPLIED BY MECHANICAL CONTRACTOR, ELECTRICAL CONTRACTOR SHALL STUB 3/4" <br />C.O. 6" ABOVE CEILING SPACE, PROVIDE BUSHING AND PULL WIRE. IF INSTALLED IN AREA WITH <br />EXPOSED STRUCTURE ABOVE OR HARDLID CEILING, PROVIDE 3/4" C.O. BACK TO ASSOCIATED HVAC <br />UNIT. REFER TO MECHANICAL DETAILS FOR T-STAT MOUNTING HEIGHT REQUIREMENTS. VERIFY <br />LOCATIONS WITH HVAC CONTRACTOR PRIOR TO ROUGH IN. <br />CARBON MONOXIDE SENSOR SUPPLIED BY MECHANICAL CONTRACTOR. ELECTRICAL CONTRACTOR <br />SHALL PROVIDE 3/4" GALVANIZED RIGID CONDUIT WITH PULL STRING BACK TO HEAD END CARBON <br />MONOXIDE PANEL. REFER TO MECHANICAL DRAWINGS FOR EXACT EQUIPMENT LOCATIONS AND <br />WIRING DETAILS. <br />CEILING MOUNTED PLUG LOAD CONTROLLER. <br />CA TITLE 24 COMPLIANT DUPLEX RECEPTACLE OUTLET, HALF-CONTROLLED, CONVENIENCE, <br />WITH PERMANENT MARKING. (20 AMPS, 125 VOLTS) MOUNTED +15" A.F.F. TO BOTTOM OF DEVICE <br />U.O.N. <br />CA TITLE 24 COMPLIANT DOUBLE DUPLEX RECEPTACLE OUTLET, HALF-CONTROLLED, <br />CONVENIENCE, WITH PERMANENT MARKING. (20 AMPS, 125 VOLTS) MOUNTED +15" A.F.F. TO <br />BOTTOM OF DEVICE U.O.N. <br />SURFACE MOUNTED DUPLEX RECEPTACLE OUTLET, CONVENIENCE. (20 AMPS, 125 VOLTS) <br />MOUNTED +15" A.F.F. TO BOTTOM OF DEVICE U.O.N. <br />GROUND WELL <br />G ON-SITE GENERATOR SET <br />200-D CONDUIT WIRING DESCRIPTION PER FEEDER SCHEDULE ON OTHER PLAN <br />CONTACT SENSOR FOR HVAC SHUTDOWN. 4S BOX, MOUNTED ABOVE DOOR OR WINDOW, U.O.N. <br />STUB 3/4" C.O. 6" ABOVE CEILING SPACE. PROVIDE BUSHING AND PULL WIRE. IF INSTALLED IN <br />AREA WITH EXPOSED STRUCTURE ABOVE OR HARD LID CEILING, PROVIDE 3/4" C.O. BACK TO <br />LOCATION OF ASSOCIATED HVAC THERMOSTAT. <br />A AMPERE <br />AF AMPERE FRAME RATING (CIRCUIT BREAKER) <br />AFF ABOVE FINISHED FLOOR <br />AFG ABOVE FINISHED GRADE <br />AFU AMPERE FUSE RATING (FUSE) <br />AIC AMPERE INTERRUPTING CAPACITY <br />AS AMPERE SWITCH RATING (FUSE) <br />AT AMPERE TRIP RATING (CIRCUIT BREAKER) <br />AWG AMERICAN WIRE GAUGE <br />BKBD BACKBOARD <br />BLDG BUILDING <br />BKR BREAKER <br />C CONDUIT <br />CB CIRCUIT BREAKER <br />CKT CIRCUIT <br />CFSD COMBINATION FIRE SMOKE DAMPER <br />CO CONDUIT ONLY <br />CONC CONCRETE <br />CT CURRENT TRANSFORMER <br />CU COPPER <br />CL CENTERLINE <br />DISC DISCONNECT <br />DSBN DISTRIBUTION SECTION <br />DN DOWN <br />DWG DRAWING <br />EA EACH <br />EC ELECTRICAL CONTRACTOR <br />EM EMERGENCY <br />EMT ELECTRICAL METALLIC TUBING <br />EXIST, (E)EXISTING <br />EXO EXTERNAL OPERABLE DISCONNECT <br />F FUSE <br />FA FIRE ALARM <br />FACP FIRE ALARM CONTROL PANEL <br />FF FINISHED FLOOR <br />FG FINISHED GRADE <br />FLA FULL LOAD CURRENT <br />FLUOR FLUORESCENT <br />GEC GROUNDING ELECTRODE CONDUCTOR <br />GEN GENERATOR <br />GFCI GROUND FAULT CIRCUIT INTERRUPTER <br />GFP GROUND FAULT PROTECTION <br />GND GROUND <br />HOA HAND-OFF-AUTOMATIC <br />HP HORSE POWER <br />HV HIGH VOLTAGE <br />IDF INTERMEDIATE DISTRIBUTION FRAME <br />IG ISOLATED/INSULATED GROUND <br />INCAND INCANDESCENT <br />ISC SHORT CIRCUIT CURRENT AVAILABLE IN RMS <br />SYMMETRICAL AMPERES <br />J-BOX JUNCTION BOX <br />KCMIL THOUSAND CIRCULAR MILS <br />KW KILOWATT <br />KV KILO VOLT <br />KVA KILO VOLT-AMPERE <br />LDC LOCAL DISTRIBUTION CABINET <br />LDF LOCAL DISTRIBUTION FRAME <br />LCL LONG CONTINUOUS LOAD <br />LTG LIGHTING <br />LV LOW VOLTAGE <br />MFR MANUFACTURER <br />MAX MAXIMUM <br />MCC MOTOR CONTROL CENTER <br />MIN MINIMUM <br />MH MANHOLE / METAL HALIDE <br />M/M METER AND MAIN SECTION <br />MULTI MULTI-METER SECTION <br />MV MEDIUM VOLTAGE <br />NC NORMALLY CLOSED <br />NEC NATIONAL ELECTRICAL CODE <br />NEMA NATIONAL ELECTRICAL MANUFACTURER'S <br />ASSOCIATION <br />NEW (N)NEW, TO BE FURNISHED AND INSTALLED BY <br />CONTRACTOR <br />NF NON-FUSED <br />NIC NOT IN CONTRACT <br />N/L NIGHT LIGHT <br />NO NUMBER, NORMALLY OPEN <br />NTS NOT TO SCALE <br />OC ON CENTER <br />OD OUTSIDE DIAMETER <br />P POLE <br />PB PULL BOX <br />PF POWER FACTOR <br />PNL PANEL <br />POC POINT OF CONNECTION <br />PP POWER POLE <br />PWR POWER <br />PVC POLYVINYL CHLORIDE <br />QUAD QUADRUPLEX <br />QTY QUANTITY <br />REQD REQUIRED <br />REQMT REQUIREMENT <br />RGS RIGID GALVANIZED STEEL <br />RMC RIGID METALLIC CONDUIT <br />RM ROOM <br />RNC RIGID NONMETALLIC CONDUIT <br />SHT SHEET <br />SN SOLID NEUTRAL <br />SPEC SPECIFICATIONS <br />SPDT SINGLE POLE, DOUBLE THROW <br />SPST SINGLE POLE, SINGLE THROW <br />SW SWITCH <br />SWBD SWITCHBOARD <br />TC TIME CLOCK <br />TEL TELEPHONE <br />TERM TERMINAL <br />TP TEMPORARY POLE <br />TYP TYPICAL <br />UGPS UNDERGROUND PULL SECTION <br />UL UNDERWRITERS LABORATORY <br />UPS UNINTERRUPTIBLE POWER SUPPLY <br />UON UNLESS OTHERWISE NOTED <br />V VOLT, VOLTAGE <br />VA VOLT-AMPERE <br />VFC VARIABLE FREQUENCY CONTROLLER <br />VFD VARIABLE FREQUENCY DRIVE <br />W WATT <br />WH WATT-HOUR <br />WP WEATHERPROOF <br />WT WEATHERTIGHT <br />WW WIREWAY <br />XP EXPLOSION PROOF <br />Z IMPEDANCE <br />4W FOUR-WIRE <br />3W THREE-WIRE <br />5S JUNCTION BOX <br />(4 11/16" SQUARED X2 1/8" DEEP) <br />Ø DIAMETER, PHASE <br />#NUMBER <br />°C DEGREE CELSIUS <br />(E)EXISTING DEVICE TO REMAIN <br />(R)REMOVE EXISTING DEVICE AND ASSOCIATED <br />CONDUIT AND WIRE <br />(RL)REMOVE EXISTING DEVICE AND RELOCATE AS <br />SHOWN ON PLAN <br />(NL)NEW LOCATION OF RELOCATED DEVICE <br />1.ALL WORK, MATERIALS AND EQUIPMENT SHALL BE CONSIDERED TO BE NEW UNLESS NOTED OTHERWISE. <br />2.ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE LATEST CODE OF REGULATIONS (CCR), NATIONAL <br />ELECTRICAL CODE EDITION AND ALL APPLICABLE LOCAL CODES AND REGULATIONS. <br />3.ALL PANELS, SWITCHES, ETC. SHALL HAVE SUFFICIENT GUTTER SPACE AND LUGS IN COMPLIANCE TO UL REQUIREMENTS <br />TO ACCOMMODATE CONDUCTORS SHOWN. <br />4.WHERE WIRE SIZES ARE INDICATED ON PLANS, FOR INDIVIDUAL CIRCUITS, THE WIRE SIZE INDICATED SHALL APPLY TO <br />THE COMPLETE CIRCUIT, UNLESS OTHERWISE NOTED. <br />5.CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF MECHANICAL, PLUMBING AND OTHER EQUIPMENT REQUIRING <br />ELECTRICAL CONNECTION PRIOR TO ANY WORK. <br />6.CONTRACTOR SHALL EXTEND WIRING FROM ALL JUNCTION BOXES, SWITCHES, ETC. AND MAKE FINAL CONNECTION AS <br />REQUIRED TO ALL BUILDING EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS. <br />7.DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS AND WORK INCLUDED. FOLLOW <br />DRAWINGS IN LAYING OUT WORK AND CHECK DRAWINGS OR OTHER TRADES RELATING TO WORK TO VERIFY SPACE IN <br />WHICH WORK WILL BE INSTALLED. MAINTAIN HEADROOM AND MINIMUM CODE REQUIRED WORKING CLEARANCES AT ALL <br />TIMES. <br />8.FURNISH APPROVED EXPANSION FITTINGS WHERE RACEWAY CROSSES BUILDING EXPANSION JOINTS. <br />9.FURNISH PULL STRING IN EACH RACEWAY RUN OVER 10' IN LENGTH, IN WHICH PERMANENT WIRING IS NOT INSTALLED. <br />10.PROVIDE PULL BOXES WHEREVER NECESSARY TO FACILITATE PULLING OF CONDUCTORS. COORDINATE LOCATIONS OF <br />BOXES WITH OTHER TRADES TO AVOID CONFLICT. PULL BOXES SHALL BE ACCESSIBLE. THE SIZE OF PULL BOX SHALL <br />COMPLY WITH N.E.C. REQUIREMENTS. <br />11.ALL EXTERIOR ELECTRICAL DEVICES AND EQUIPMENT INCLUDING THOSE THAT ARE EXPOSED TO OUTSIDE <br />ENVIRONMENT (UP TO 16') SHALL BE WEATHERPROOF TYPE, NEMA 3R. <br />12.NO CONDUIT RUNS SHALL BE ALLOWED IN CONCRETE SLABS. ALL CONDUITS WILL BE PLACED ABOVE ACCESSIBLE <br />CEILING SPACES UNLESS SPECIFICALLY INDICATED TO BE UNDERGROUND. <br />13.DISCONNECT SWITCHES SHALL BE MOUNTED ON INDIVIDUAL SUPPORTS, OR OTHERWISE DIRECTLY ON EQUIPMENT, <br />PROVIDED NO MODIFICATION TO EQUIPMENT IS NECESSARY. <br />14.ALL ELECTRICAL POWER LIGHTING, TELEPHONE OR SIGNAL WIRING IN FIRE RATED WALL IS TO BE INSTALLED IN A <br />METALLIC CONDUIT SYSTEM. <br />15.ALL ELECTRIC MATERIAL SHALL BE LISTED BY "UL" FOR THE TYPE OF APPLICATION AND "UL" LABEL SHALL APPEAR ON <br />ALL ELECTRICAL EQUIPMENT. <br />16.ALL DISTRIBUTION AND CONTROL EQUIPMENT (SUCH AS CB's, SWITCHES, CONTACTORS, ETC.), TERMINATIONS SHALL BE <br />FULLY RATED PER UL AS FOLLOWS: <br />a. 125A OR LESS : 60°C OR MORE; <br />b. MORE THAN 125A : 75°C OR MORE. <br />17.ANY ERRORS, OMISSIONS, OR DESIGN DISCREPANCIES ON PLANS OR SPECIFICATIONS SHALL BE BROUGHT TO THE <br />ATTENTION OF THE ELECTRICAL ENGINEER FOR CLARIFICATION OR CORRECTION PRIOR TO CONSTRUCTION AND <br />PREPARATION OF SUBMITTAL PACKAGES. <br />18.CONDUCTORS SHALL HAVE UNDERWRITER'S LABORATORIES, INC.(UL) LISTED, 600 VOLT INSULATION OF TYPE SPECIFIED <br />BELOW OR ELSEWHERE IN THE SPECIFICATIONS. CONDUCTORS SHALL BE COPPER AND LISTED FOR 90 DEGREE <br />APPLICATIONS. <br />1. BRANCH CIRCUITS - LIGHTING AND POWER. <br />a. #10 AWG AND SMALLER, SOLID WIRE TYPE THW OR THHN/THWN-2, THHW(THHN FOR DRY LOCATION ONLY). <br />b. #8 AWG TO #2 AWG, STRANDED TYPE THW OR THHN/THHW. <br />c. #1 AWG AND LARGER, STRANDED TYPE XHHW. <br />2. FEEDERS : TYPE THW OR THHN/THWN-2, OR XHHW. <br />19.PROVIDE GREEN INSULATED GROUNDING CONDUCTOR IN EACH RACEWAY INCLUDING CONDUITS, PLUG STRIPS, <br />WIREMOLD. SIZE OF GROUNDING SHALL BE IN ACCORDANCE WITH NATIONAL ELECTRIC CODE ARTICLE 250. <br />20.WIRING METHOD SHALL BE EMT ABOVE GROUND AND MOUNTED IN CONCEALED SPACES AND SCHEDULE-40 PVC FOR <br />UNDERGROUND INSTALLATION. USE RIGID WHEN ENCASED IN CONCRETE OR SUSCEPTIBLE TO DAMAGE. <br />21.USE 10AWG CONDUCTORS FOR 20 AMPERE, 120V BRANCH CIRCUITS LONGER THAN 75 FEET. <br />USE 10AWG CONDUCTORS FOR 20 AMPERE, 277V BRANCH CIRCUITS LONGER THAN 200 FEET. <br />22.UNLESS OTHERWISE INDICATED, SHARING OF NEUTRAL/GROUNDED CONDUCTORS AMONG SINGLE PHASE BRANCH <br />CIRCUITS OF DIFFERENT PHASES INSTALLED IN THE SAME RACEWAY IS NOT PERMITTED. PROVIDE DEDICATED <br />NEUTRAL/GROUNDED CONDUCTOR FOR EACH INDIVIDUAL BRANCH CIRCUIT. <br />23.ALL ELECTRICAL WORK SHALL BE DESIGNED PER 2020 LOS ANGELES COUNTY ELECTRICAL CODE, 2019 NEC ELECTRICAL <br />CODE, 2017 NATIONAL ELECTRICAL CODE, AND 2019 BUILDING ENERGY EFFICIENCY STANDARDS. <br />24.ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, LISTED, OR CERTIFIED BY A NATIONAL RECOGNIZED TESTING <br />LABORATORY ACCREDITED BY THE UNITED STATES OCCUPATIONAL SAFETY HEALTH ADMINISTRATION. <br />SINGLE LINE DIAGRAM SYMBOLS <br />COMMERCIAL GENERAL NOTES LIGHTING SYMBOLS <br />CODES <br />SURGE PROTECTION DEVICE <br />RECESSED CEILING MOUNTED LED FIXTURE <br />298 TENNESSEE STREET <br />REDLANDS, CA 92373 <br />P: (909) 281-8100 <br />E: svela@velaengineering.biz <br />X <br />SAMUEL VELA <br />PS- <br />X <br />X <br />- <br />X <br />X <br />X <br />X <br />CITY OF SANTA ANA <br />PUBLIC WORKS AGENCY <br />REVISIONS REFERENCES <br />CONSTRUCTION COMPLETED: <br />BENCHMARK NO.: SA-253-70 ELEV.: 176.00 (2010) <br />PREPARED UNDER THE <br />SUPERVISION OF: <br />SHEET OF <br />DRAWN:DESIGNED:CHECKED: <br />UNDERGROUND SERVICE ALERT OF SOUTHERN <br />CALIFORNIA <br />811 <br />ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF <br />UNDERGROUND FACILITIES NOT KNOWN OR IN A LOCATION <br />DIFFERENT FROM THAT WHICH IS SHOWN ON THE PLANS OR IN <br />THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE <br />STEPS TO ASCERTAIN THE EXACT LOCATION OF ALL <br />UNDERGROUND FACILITIES PRIOR TO DOING WORK THAT MAY <br />DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICE <br />BEFORE EXCAVATING. THE CONTRACTOR SHALL VERIFY THE <br />LOCATION OF UNDERGROUND UTILITIES BY CONTRACTING <br />UNDERGROUND SERVICES ALERT. DIAL 811 <br />REVIEWED FOR <br />CONSTRUCTABLITY: <br />RECOMMENDED FOR <br />CONSTRUCTION: <br />ARCHITECT <br />INSTALLED <br />1700 E. SANTA CLARA AVENUE, SANTA ANA, CA 92705 <br />FILE NO: <br />PRINCIPAL CIVIL ENGINEER RCE NO.: <br />PRINCIPAL CIVIL ENGINEER RCE NO.: <br />PORTOLA PARK <br />SPLASH PAD <br />NUMBER DATE INITALS DESCRIPTION APPROVED <br />ELECTRICAL NOTES E0.1 <br />PO <br />R <br />T <br />O <br />L <br />A <br /> <br />P <br />A <br />R <br />K <br /> <br />S <br />P <br />L <br />A <br />S <br />H <br /> <br />P <br />A <br />D <br /> <br />P <br />R <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />O <br />. <br /> <br />2 <br />5 <br />- <br />2 <br />4 <br />0 <br />1 <br />PO <br />R <br />T <br />O <br />L <br />A <br /> <br />P <br />A <br />R <br />K <br /> <br />S <br />P <br />L <br />A <br />S <br />H <br /> <br />P <br />A <br />D <br /> <br />P <br />R <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />O <br />. <br /> <br />2 <br />5 <br />- <br />2 <br />4 <br />0 <br />1 <br />SHEET 47 OF 57