Laserfiche WebLink
FD <br />FD <br />EXISTING WOOD STUD WALLS TO REMAIN. <br />PATCH AND REPAIR TO MATCH EXISTING <br />FINISHES WHERE DAMAGED BY DEMOLITION. <br />NEW 8X8X16 CMU WALL <br />EXISTING CMU WALLS TO REMAIN. PATCH <br />AND REPAIR TO MATCH EXISTING FINISHES <br />WHERE DAMAGED BY DEMOLITION. <br />DEMOLISH EXISTING CMU WALL <br />DEMOLISH <br />NEW 4" SHOTCRETE WALL <br />MEN'S <br />RESTROOM <br />WOMEN'S <br />RESTROOM <br />STORAGE/ <br />MAINTENANCE <br />22 A <br />22 A <br />22 A <br />22 A <br />22 A <br />22 A <br />10 L <br />10 L <br />10 L <br />10 I <br />10 L <br />22 D <br />22 D <br />10 A (E) ELECTRICAL <br />EDGE OF (E) ROOF <br />TYP. <br />10 A <br />09 J <br />09 J <br />32 B <br />EDGE OF (E) ROOF <br />(E) ELECTRICAL MAIN SERVICE <br />EDGE OF (N) ROOF <br />WOMEN'S <br />144 <br />MEN'S <br />145 <br />STORAGE/ <br />MAINTENANCE <br />146 <br />SPLASH PAD <br />MAINTENANCE <br />EXPANSION <br />147 <br />8' <br /> <br />- <br /> <br />4 <br />" <br />13 <br />' <br /> <br />- <br /> <br />4 <br />" <br />12' - 9"7' - 11" <br />10 <br />' <br /> <br />- <br /> <br />0 <br />" <br /> <br />3 <br />' <br /> <br />- <br /> <br />4 <br />" <br />10 <br />' <br /> <br />- <br /> <br />0 <br />" <br />8' - 9"11' - 11" <br />20' - 4" <br />22-22 <br />22-22 <br />22-26 <br />22-25 <br />22-25 <br />22-23 <br />22-23 <br />09-54 <br />09-54 <br />03-06 <br />03-06 <br />5' <br /> <br />- <br /> <br />0 <br />" <br />2' <br /> <br />- <br /> <br />8 <br />" <br />2' <br /> <br />- <br /> <br />8 <br />" <br />44" MIN. <br />4' - 5" <br />1' <br /> <br />- <br /> <br />6 <br />" <br />1' <br /> <br />- <br /> <br />6 <br />" <br />8' - 1" <br />4" <br />8' - 0" <br />4" <br />1' <br /> <br />- <br /> <br />6 <br />" <br />EQ <br />EQ <br />1' <br /> <br />- <br /> <br />6 <br />" <br />EQ <br />EQ <br />09-54 <br />P-1 <br />EPX-1A2.08 6 <br />5 <br />7 <br />A2.0 <br />3 <br />2 <br />1 <br />4 <br />A2.0 <br />12 <br />11 <br />10 <br />9 <br />1 <br />2 3 <br />4ED <br />G <br />E <br /> <br />O <br />F <br /> <br />( <br />N <br />) <br /> <br />R <br />O <br />O <br />F <br />ED <br />G <br />E <br /> <br />O <br />F <br /> <br />( <br />E <br />) <br /> <br />R <br />O <br />O <br />F <br />EDGE OF (E) ROOF <br />ED <br />G <br />E <br /> <br />O <br />F <br /> <br />( <br />E <br />) <br /> <br />R <br />O <br />O <br />F <br />A4.0 <br />3 <br />A4.04 <br />A4.0 <br />5 <br />A4.0 1 <br />2 <br />A4.0 <br />3' <br /> <br />- <br /> <br />0 <br />" <br />5' <br /> <br />- <br /> <br />0 <br />" <br />6 <br />A4.0 <br />EPX-1 <br />FD-1 <br />FD-1 <br />09-10 <br />09-10 <br />09-10 <br />A5.1 <br />1 <br />A5.1 <br />1 <br />8' - 1" <br />1' - 4" <br />1' - 4" <br />4' - 0" <br />1' - 4" <br />1' <br /> <br />- <br /> <br />4 <br />" <br />1' <br /> <br />- <br /> <br />4 <br />" <br />(E) ELECTRICAL <br />PANELS TO REMAIN 26-05 <br />09-10 <br />CONC. <br />10-21 <br />10-22 <br />A5.1 <br />4 <br />A5.1 <br />7 <br />10-21 <br />10-22 A5.1 <br />7 <br />A5.1 <br />4 <br />A5.1 <br />13 <br />A5.1 <br />13 <br />10-79 <br />A5.1 <br />14 <br />DOOR TO BE IN THE LOCKED AND <br />OPEN POSITION DURING HOURS <br />OF USE <br />DOOR TO BE IN THE LOCKED AND <br />OPEN POSITION DURING HOURS <br />OF USE <br />32-2 <br />1' - 10" <br />TYP. <br />22" <br />1. CAP ALL EXISTING UTILITIES & PREPARE FOR NEW WORK AS REQUIRED. <br />2. PROVIDE ALL LABOR, MATERIAL, AND EQUIPMENT NECESSARY TO <br />COMPLETE DEMOLITION WORK AS INDICATED ON DRAWINGS AND <br />SPECIFICATIONS AND AS REQUIRED TO ACCOMMODATE NEW <br />CONSTRUCTION. <br />3. PATCH, REPAIR, AND RESTORE ALL AREAS DAMAGED BY THE <br />CONSTRUCTION WORK AND DEMOLITION TO MATCH CONDITION OF <br />ADJACENT UNDISTURBED SURFACES. <br />4. REMOVE FROM THE SITE ALL MATERIAL RESULTING FROM THE <br />DEMOLITION WORK IN SUCH A MANNER AS TO AVOID CREATING A <br />NUISANCE. DISPOSE OF ALL MATERIALS FROM THE SITE ON A DAILY BASIS <br />AT NO ADDITIONAL COST TO THE OWNER. <br />5. DISPOSE OF ALL MATERIAL RESULTING FROM THE DEMOLITION WORK IN <br />ACCORDANCE WITH ALL APPLICABLE LAWS AND REGULATIONS, INCLUDING <br />THOSE GOVERNING NOISE, DUST, AND DIRT CONTROL; DISPOSAL OF <br />HAZARDOUS MATERIALS; AND REQUIREMENTS OF THE LOCAL AIR QUALITY <br />MANAGEMENT DISTRICT. <br />6. WALL TILE DEMOLITON WORK SHALL BE COORDINATED WITH THE LIMITED <br />ASBESTOS CONTAINING MATERIALS & LEAD-BASED PAINTG SURVEY <br />REPORT CLARK SEIF CLARK INC., DATED SEPTEMBER 15, 2023. SEE VI <br />CONCLUSION & RECOMMENDATON ITEM A & B. <br />7. POWER AND IRRIGATION CONTROLLER SHALL BE MAINTAINED DURING <br />CONSTRUCTION <br />C.WHERE EXISTING PLUMBING VENT PIPES ARE REMOVED FROM THE ROOF <br />AND NEW ONES ARE INSTALLED THE CONTRACTOR SHALL PATCH AND <br />REPAIR THE ROOF. THE PATCHING AND REPAIR SHALL BE DONE USING A <br />SUB-CONTRACTOR EXPERIENCED WITH ROOFING AND ROOFING REPAIRS. <br />A.ELECTRICAL / MECHANICAL EQUIPMENT AND DEVICES: REINSTALL AND <br />PROPERLY RECONNECT EXISTING DUCTWORK; SWITCHES; THERMOSTATS; <br />AND OTHER EXISTING ELEC./MECH., EQUIPMENT AND DEVICES REMOVED <br />DURING THE WORK BUT NOT INDICATED TO BE REMOVED. REINSTALL <br />ONLY EQUIPMENT AND DEVICES THAT ARE IN GOOD CONDITION STATE <br />APPROVAL IS NEEDED FOR MATERIALS THAT ARE TO BE REUSED. DISCARD <br />EQUIPMENT AND DEVICES THAT ARE NOT IN CONDITION AT LEAST AS <br />GOOD AS EXISTED BEFORE REMOVAL, AND PROVIDE NEW EQUIVALENT <br />EQUIPMENT AND DEVICES. NEW EQUIPMENT AND DEVICES SHALL EXACTLY <br />MATCH THOSE REMOVED IN TYPE, SIZE, FINISH, CONFIGURATION , AND <br />OPERATING CHARACTERISTICS, UNLESS NOTED OTHERWISE. ALL <br />INSTALLATION SHALL MEET CURRENT BUILDING CODE. <br />B.PROVIDE NEW MATERIALS TO MATCH EXISTING UNDISTURBED WORK FOR <br />CLOSING OF OPENINGS, REPAIRS, AND RENOVATION. NEW FINISH <br />MATERIALS AND SUBSTRATES TO MATCH EXISTING SHALL BE THE SAME <br />TYPES, SIZES, QUALITIES, AND COLORS AS EXISTING ADJACENT MATERIAL. <br />REPAIR ALL DAMAGED OR DEFACED FLOOR, WALL, AND CEILING FINISHES <br />ASSOCIATED WITH THESE ALTERATIONS. <br />D.FLOOR COVERING MATERIALS SHALL COMPLY WITH ASTM STANDARD E <br />648, AND HAVING A SPECIFIC OPTICAL DENSITY SMOKE RATING NOT TO <br />EXCEED 450 PER ASTM E 662. CBC 804.4 <br />NEW CONCRETE SLAB <br />NEW EPOXY FLOORING <br />PS-25-2401 <br />CITY OF SANTA ANA <br />PUBLIC WORKS AGENCY <br />REVISIONS REFERENCES <br />CONSTRUCTION COMPLETED: <br />BENCHMARK NO.: SA-253-70 ELEV.: 176.00 (2010) <br />PREPARED UNDER THE <br />SUPERVISION OF: <br />SHEET OF <br />1511 Cota Ave. Long Beach, <br />CA 90813 Tel. 562-912-7900 <br />Architecture <br />Government Services <br />Edward <br />Lok Ng <br />C-16840 <br />REN.11/30/25 <br />LICENSED A RCHITECT <br />STATE OF C ALIFORNIA <br />DRAWNDESIGNED:CHECKED: <br />UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA <br />811 <br />ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF <br />UNDERGROUND FACILITIES NOT KNOWN OR IN A LOCATION <br />DIFFERENT FROM THAT WHICH IS SHOWN ON THE PLANS OR IN <br />THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE <br />STEPS TO ASCERTAIN THE EXACT LOCATION OF ALL <br />UNDERGROUND FACILITIES PRIOR TO DOING WORK THAT MAY <br />DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICE <br />BEFORE EXCAVATING. THE CONTRACTOR SHALL VERIFY THE <br />LOCATION OF UNDERGROUND UTILITIES BY CONTRACTING <br />UNDERGROUND SERVICES ALERT. DIAL 811 <br />LOK NG: <br />REVIEWED FOR <br />CONSTRUCTABLITY: <br />RECOMMENDED FOR <br />CONSTRUCTION: <br />ARCHITECT <br />INSTALLED <br />1700 E. SANTA CLARA AVENUE, SANTA ANA, CA 92705 <br />FILE NO: <br />PRINCIPAL CIVIL ENGINEER RCE NO.: <br />PRINCIPAL CIVIL ENGINEER RCE NO.:G: <br />\ <br />P <br />r <br />o <br />j <br />e <br />c <br />t <br /> <br />F <br />i <br />l <br />e <br />s <br />\ <br />3 <br />1 <br />3 <br />9 <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br /> <br />P <br />o <br />r <br />t <br />o <br />l <br />a <br /> <br />P <br />a <br />r <br />k <br /> <br />R <br />e <br />s <br />t <br />o <br />o <br />m <br />R <br />e <br />n <br />o <br />v <br /> <br />& <br /> <br />A <br />d <br />d <br /> <br />f <br />o <br />r <br /> <br />D <br />V <br />D <br />\ <br />0 <br />1 <br />- <br />D <br />r <br />a <br />w <br />i <br />n <br />g <br />s <br />\ <br />0 <br />1 <br />- <br />R <br />e <br />v <br />i <br />t <br />\ <br />3 <br />- <br />C <br />D <br />\ <br />3 <br />1 <br />3 <br />9 <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br /> <br />P <br />o <br />r <br />t <br />o <br />l <br />a <br /> <br />P <br />a <br />r <br />k <br /> <br />R <br />e <br />s <br />t <br />r <br />o <br />o <br />m <br /> <br />R <br />e <br />n <br />o <br /> <br />& <br /> <br />A <br />d <br />d <br /> <br />C <br />D <br />. <br />r <br />v <br />t <br />A1.0 <br />PORTOLA PARK <br />SPLASH PAD <br />DEMOLITION & RENOVATION FLOOR PLAN <br />JSAF LN <br />PO <br />R <br />T <br />O <br />L <br />A <br /> <br />P <br />A <br />R <br />K <br /> <br />S <br />P <br />L <br />A <br />S <br />H <br /> <br />P <br />A <br />D <br /> <br />P <br />R <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />O <br />. <br /> <br />2 <br />5 <br />-24 <br />0 <br />1 <br />WALL LEGEND <br />SCALE: 1/4" = 1'-0"1 DEMOLITION FLOOR PLAN <br />DEMOLITION KEYNOTES <br />09 J REMOVE EXISTING EXPOXY FLOOR FINISH AND PREPARE <br />CONCRETE SURFACE FOR NEW WORK. <br />10 A REMOVE EXISTING TOILET PARTITIONS AND ATTACHED TOILET <br />ACCESSORIES. <br />10 I REMOVE EXISTING WALL MOUNTED SIGNAGE AND PREPARE FOR <br />NEW WORK. <br />10 L DEMOLISH EXISTING PLUMBING ACCESSORIES TYP. <br />22 A REMOVE EXISTING PLUMBING FIXTURE AND ASSOCIATED FITTINGS. <br />CAP UTILITY LINES BELOW WALL/FLOOR SURFACES AS REQUIRED. <br />RECONNECT PIPING TO NEW FIXTURES SHOWN ON RENOVATION <br />PLAN. PATCH AND REPAIR IMPACTED WALL/FLOOR SURFACES. <br />22 D REMOVE EXISTING HOSE BIB. <br />32 B REMOVE EXISTING IRRIGATION CONTROLS. PREPARE AREA FOR <br />NEW WORK. <br />SCALE: 1/4" = 1'-0"2 RENOVATION FLOOR PLAN <br />RENOVATION KEYNOTES <br />03-06 NEW 2,500 PSI CONCRETE SLAB, 4" THICK MIN. TO MATCH <br />EXISTING CONCRETE SLAB OVER 2" SAND, PROVIDE #4 <br />REBARS @ 16" O.C. AND 6" EMBEDMENT INTO EXISTING <br />SLAB. NEW CONCRETE SLAB TO BE FLUSH WITH EXISTING <br />SLAB. <br />09-10 NEW 4" HIGH RUBBER BASE. SEE FINISH MATERIAL <br />SCHEDULE. <br />09-54 NEW 2-PART EPOXY FLOOR FINISH. PROVIDE TEXTURED <br />FINISH AT WET LOCATION. SEE FINISH SCHEDULE. <br />10-21 NEW RESTROOM DOOR SIGNAGE - PROVIDE NEW <br />ACCESSIBLE COMPLYING ROOM SIGNAGE. PATCH AND <br />REPAIR DOOR/WALL FINISHES AND SUBSTRATES MATERIALS <br />DAMAGED BY RETROFIT WORK TO MATCH THE CONDITION <br />OF ADJACENT UNDISTURBED SURFACES. <br />10-22 NEW WALL MOUNTED SIGN. <br />10-79 NEW DOOR MOUNTED NO ACCESS SIGNAGE. <br />22-22 NEW WALL MOUNTED LAVATORY WITH ADA COMPLIANT <br />FAUCET AND PIPE INSULATION TO FULLY COVER <br />DRAIN/WATER PIPES AND EXPOSED SHARP/ABRASIVE <br />SURFACES UNDER THE LAVATORY. SEE PLUMBING FIXTURE <br />SCHEDULE. <br />22-23 NEW WALL MOUNTED URINAL. SEE PLUMBING DRAWINGS <br />FOR MORE INFORMATION. <br />22-25 NEW ADA COMPLIANT WALL MOUNTED WATERCLOSET. SEE <br />PLUMBING DRAWINGS FOR MORE INFORMATION. <br />22-26 NEW WALL MOUNTED WATERCLOSET. SEE PLUMBING <br />DRAWINGS FOR MORE INFORMATION. <br />26-05 NEW ELECTRICAL PANELS. SEE ELECTRICAL DRAWINGS FOR <br />MORE INFORMATION. <br />32-2 PROVIDE NEW IRRIGATION CONTROLS CALSENSE 3000 <br />CONNECT TO EXISTING IRRIGATION SYSTEM, MODIFY AS <br />NEEDED. <br />DEMOLITION NOTES <br />RENOVATION NOTES <br />N <br />FLOOR LEGEND <br />NUMBER DATE INITALS DESCRIPTION APPROVED <br />N <br />"NO ROOMS CLASSIFIED AS INCIDENTAL USE PER TABLE 509.1" <br />SHEET 29 OF 57