FD <br />FD <br />Q <br />Q <br />Q Q <br />Q <br />Q <br />Q <br />C <br />FD <br />FD <br />KEY MAP <br />N.T.S.PORTOLA AVEN <br />EXISTING PARKING LOT <br />L-701 <br />0 10'5'20' <br />Scale: 1" = 10'-0" <br />N <br />IRRIGATION MODIFICATION PLAN <br />NUMBER DATE INITIALS DESCRIPTION <br />PREPARED UNDER THE <br />SUPERVISION OF: <br />CITY OF SANTA ANA <br />FILE NO.: <br />INSTALLEDAPPROVED <br />CONSTRUCTION COMPLETED: <br />BENCHMARK NO.: SA-253-70 <br />RECOMMENDED FOR <br />CONSTRUCTION: <br />REFERENCES <br />PUBLIC WORKS AGENCY <br />XRCE NO.: <br />ELEV.: 176.00 (2010) <br />REVISIONS <br />SHEET OF <br />BENCHMARK DESCRIPTION: <br />OCS BM SA-253-70 <br />FD 3 3/4" OCS ALUMINUM BENCH MARK DISK STAMPED "SA-253-70", SET IN NW'LY CORNER OF A 3.5FT X 16FT <br />CONCRETE CATCH BASIN. MONUMENT IS LOCATED IN THE NE'LY CORNER OF THE INTERSECTION OF GRAND AVE <br />AND SANTA CLARA AVE, 87FT N'LY OF THE CENTERLINE OF SANTA CLARA AVE AND 39FT E'LY OF THE CENTERLINE <br />OF GRAND AVE. MONUMENT IS SET LEVEL WITH THE SIDEWALK <br />PORTOLA PARK <br />SPLASH PADREVIEWED FOR <br />CONSTRUCTABLITY: <br />PRINCIPAL CIVIL ENGINEER <br />DESIGNED: <br />PRINCIPAL CIVIL ENGINEER RCE NO.: <br />ES MM ES <br />LANDSCAPE ARCHITECT <br />DRAWN:CHECKED: <br />PS- <br />2 <br />5 <br />- <br />2 <br />4 <br />0 <br />1 <br />GARY VASQUEZ <br />1700 E. SANTA CLARA AVENUE, SANTA ANA, CA 92705 <br />811 <br />UNDERGROUND SERVICE ALERT. DIAL 811 <br />LOCATION OF UNDERGROUND UTILITIES BY CONTRACTING <br />BEFORE EXCAVATING, THE CONTRACTOR SHALL VERIFY THE <br />DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICE. <br />UNDERGROUND FACILITIES PRIOR TO DOING WORK THAT MAY <br />STEPS TO ASCERTAIN THE EXACT LOCATION OF ALL <br />THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE <br />DIFFERENT FROM THAT WHICH IS SHOWN ON THE PLANS OR IN <br />UNDERGROUND FACILITIES NOT KNOWN OR IN A LOCATION <br />ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF <br />UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA <br />11/26/25 <br />LICENSED LANDSCAPE ARCHITECT <br />SIGNATUREGARY M. VASQUEZ #3883 <br />DATE <br />RENEWAL DATE <br />02/2027 <br />AINROFILACFOETATS <br />DVDCreative <br />151 Kalmus Drive, Suite M8 <br />Costa Mesa, CA 92626 <br />714.641.1300 <br />dvdcreative.com <br />PO <br />R <br />T <br />O <br />L <br />A <br /> <br />P <br />A <br />R <br />K <br /> <br />S <br />P <br />L <br />A <br />S <br />H <br /> <br />P <br />A <br />D <br /> <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />O <br />. <br /> <br />2 <br />5 <br />- <br />2 <br />4 <br />0 <br />1 <br />LIMIT <br /> <br />O <br />F <br /> <br />W <br />O <br />R <br />K <br />EX. TREE <br />PROTECT-IN-PLACE <br />TYP. <br />EX. TREE <br />PROTECT-IN-PLACE <br />TYP. <br />EX. TREE <br />PROTECT-IN-PLACE <br />TYP. <br />EX. TREE <br />PROTECT-IN-PLACE <br />TYP. <br />EX. TREE <br />PROTECT-IN-PLACE <br />TYP. <br />EX. TREE <br />PROTECT-IN-PLACE <br />TYP. <br />EX. TREE <br />PROTECT-IN-PLACE <br />TYP. <br />EXISTING <br />RESIDENTIAL <br />LIM <br />I <br />T <br /> <br />O <br />F <br /> <br />W <br />O <br />R <br />K <br />IRRIGATION CONSTRUCTION NOTES <br />1.THE CONTRACTOR SHALL ENSURE THE FUNCTIONALITY/ OPERABILITY OF THE EXISTING IRRIGATION SYSTEM PRIOR TO ANY <br />CONSTRUCTION. WHERE THE NEW IMPROVEMENTS IMPACT THE PERFORMANCE OF THE EXISTING IRRIGATION SYSTEM THE <br />CONTRACTOR SHALL BE RESPONSIBLE TO REPAIR/ RELOCATE EXISTING NON-PRESSURE LATERAL LINES AND POP-UP SPRAY/ <br />OVERHEAD IRRIGATION. THE MODIFICATION OF THE EXISTING IRRIGATION SYSTEM SHALL BE INSTALLED TO PROVIDE HEAD TO <br />HEAD 100% COVERAGE WITH MINIMAL OVERSPRAY ONTO WALKS, SIGNS, AND HARDSCAPE. WHERE EXISTING VALVES SERVING <br />TURF IRRIGATION ARE TO REMAIN, THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING NEW IRRIGATION HEADS/ ROTORS, <br />NOZZLES, PRESSURE MAINLINE AND NON-PRESSURE LATERAL LINE PIPE TO ENSURE FUNCTIONALITY OF THE SYSTEM. <br />2.SECURE PERMISSION FROM THE OWNER AND PARK MAINTENANCE STAFF TO SHUT OFF THE IRRIGATION WATER SUPPLY TO <br />PORTIONS OF THE SITE. IN THE EVENT THAT IT IS NECESSARY CONTRACTOR TO PROVIDE HAND WATERING OR ALTERNATIVE <br />METHODS TO IRRIGATE EXISTING PLANTING AREAS SERVED BY THE AFFECTED PORTION OF THE IRRIGATION SYSTEM. <br />3.CONTRACTOR TO LOCATE AND FIELD VERIFY EXISTING POTABLE WATER BACKFLOW PREVENTER ASSEMBLY FOR EXISTING <br />IRRIGATION SYSTEM AND IRRIGATION SYSTEM IMPROVEMENTS, NOT SHOWN ON PLANS. CONTRACTOR TO VERIFY EXISTING <br />BACKFLOW PREVENTER ASSEMBLIES ARE INSTALLED PER CODE AND REQUIRE NO SERVICE OR REPAIR THAT WOULD PREVENT <br />INSTALLATION OR CONNECTION PER PLAN. ALL IRRIGATION WORK TO BE COORDINATED AND APPROVED BY CITY. <br />4.CONTRACTOR TO LOCATE AND INTERCEPT EXISTING LATERAL LINE PIPING AND CONNECT NEW LATERAL LINE PIPING TO ENSURE <br />100% IRRIGATION COVERAGE AT EXISTING TURF AREAS. <br />5.REPAIR DAMAGE TO EXISTING PLANTING AREA FINISH GRADES CAUSED BY LANDSCAPE CONSTRUCTION OPERATIONS. PROVIDE <br />ADDITIONAL SOIL COMPACTION AS REQUIRED TO REPAIR THE SETTLING OF GRADES TO THE SATISFACTION OF THE LANDSCAPE <br />ARCHITECT AND OWNER. <br />6.REPLACE AND / OR REPAIR DAMAGE TO EXISTING IRRIGATION SYSTEM CAUSED BY INSTALLATION OF NEW IRRIGATION SYSTEM. <br />7.CONTRACTOR TO VERIFY AND PROVIDE WRITTEN REPORT TO OWNER THAT EXISTING SYSTEM IS IN PROPER WORKING ORDER <br />REQUIRING NO REPAIRS PRIOR TO CONNECTION OF NEW IMPROVEMENTS. <br />8.ANY DAMAGE TO LANDSCAPE OR IRRIGATION OUTSIDE THE LIMITS OF WORK SHALL BE REPAIRED AT THE CONTRACTOR'S <br />EXPENSE. <br />IRRIGATION CONSTRUCTION MODIFICATION NOTES <br />1 LOCATE AND INTERCEPT EXISTING MAIN LINE PIPING AND CONNECT NEW <br />MAIN LINE PIPING - ADAPT NEW PIPING AS REQUIRED FOR PERMANENT <br />CONNECTION - PROTECT IN PLACE EXISTING CONTROLLER WIRES <br />LOCATED WITH MAIN LINE <br />2 VERIFY EXISTING IRRIGATION VALVE ASSIGNMENTS AND CONNECT <br />NEW ECV TO NEXT AVAILABLE STATION AT EXISTING IRRIGATION <br />CONTROLLER 'C' - INSTALL ADD-A-ZONE MODEL NO. RCO860009 SERIES <br />STATION MULTIPLIER AT NEW VALVE, LOCATE WITHIN VALVE BOX 'C-20' <br />1.REFER TO SHEET L-700A AND L-700B FOR COMPLETE <br />IRRIGATION LEGEND, NOTES, AND PRESSURE LOSS <br />CALCULATIONS. <br />2.REFER TO SHEET L-750 FOR IRRIGATION DETAILS. <br />3.AUTOMATIC LANDSCAPE IRRIGATION EQUIPMENT <br />SHALL BE INSTALLED IN SUCH A WAY THAT IT DOES <br />NOT SPRAY ON THE HARDSCAPE. <br />SYMBOL DESCRIPTION <br />ELECTRIC CONTROL VALVE <br />PRESSURE MAIN LINE - SIZE NOTED <br />NON-PRESSURE LATERAL LINE PIPING - <br />SIZE NOTED <br />L INDICATES PLANT WATER USE CATEGORY <br />(L= LOW, M=MODERATE, H=HIGH, WATER USE). <br />INDICATES PRECIPITATION RATE <br />INDICATES ELECTRIC CONTROL VALVE SIZE <br />INDICATES IRRIGATION SPRINKLER CONTROLLER <br />STATION NUMBER <br />INDICATES FLOW IN GPM FOR ELECTRIC <br />CONTROL VALVE <br />1"0.6 <br />5.0 <br />VALVE CALLOUT LEGEND <br />EQUIPMENT LEGEND NOTES <br />C-1 <br />EXISTING PRESSURE MAIN LINE PIPING <br />GATE VALVE <br />IRRIGATION PROTECTION LEGEND <br />DESCRIPTION <br />PROTECT IN PLACE IRRIGATION <br />LATERAL LINE AND OVERHEAD SPRAY <br />SPRINKLERS WHERE TRENCHING <br />OCCURS. CONTRACTOR TO REPAIR <br />ANY DAMAGE TO THE IRRIGATION <br />SYSTEM AT NO EXPENSE TO THE CITY. <br />SYMBOL <br />EXISTING CALSENSE <br />CONTROLLER 'C'C <br />Q OVERHEAD SPRAY NOZZLES - SEE <br />"SPRAY SPRINKLER LEGEND" SHEET L-700A <br />PROVIDE FOUR SPARE WIRES AND TWO SPARE COMMON WIRES <br />CONTINUOUSLY FROM AUTOMATIC CONTROLLER TO LAST ELECTRIC <br />CONTROL VALVE BOX, FOLLOWING MAIN LINE ROUTE. ALLOW 30-INCH <br />EXPANSION LOOP AT EACH CONTROL VALVE ALONG MAIN LINE ROUTING. <br />THE LOCATIONS FOR SPARE WIRES ARE IDENTIFIED ON DRAWING WITH <br />THE WORDS "PROVIDE SPARE WIRES AT ECV". <br />SPARE WIRE NOTE <br />EXISTING OVERHEAD SPRAY BODIES - <br />PROTECT-IN-PLACE <br />EXISTING NON-PRESSURE LATERAL LINE - <br />PROTECT-IN-PLACE <br />OVERHEAD SPRAY NOZZLE REPLACEMENT <br />ON EXISTING ROTORS - SEE "SPRAY <br />SPRINKLER LEGEND" SHEET L-700A <br />SYMBOL DESCRIPTION <br />BELOW GRADE STORAGE TANK <br />PROTECT-IN-PLACE , TYP. <br />1 1 <br />RAIN DIVERTER <br />PROTECT-IN-PLACE , TYP. <br />RESTROOM <br />AND SPLASH <br />PAD <br />BUILDING <br />LIMIT O <br />F <br /> <br />W <br />O <br />R <br />K <br />EXISTING <br />BALLFIELD <br />LIM <br />I <br />T <br /> <br />O <br />F <br /> <br />W <br />O <br />R <br />K <br />0.5 <br />13.5 C-20+ <br />2"M <br />EXISTING IRRIGATION <br />CONTROLLER 'C' <br />EXISTING IRRIGATION MAIN LINE LOCATION - <br />LOCATION IS DIAGRAMMATIC, <br />SEE "EQUIPMENT LEGEND" THIS SHEET <br />EXISTING VALVE BOX 'C-20' - FIELD VERIFY <br />LOCATION AND INSTALL "ADD-A-ZONE" STATION <br />MULTIPLIER - SEE "IRRIGATION CONSTRUCTION <br />NOTES" #2, THIS SHEET <br />REPLACE NOZZLES AT EXISTING ROTORS TO <br />FACILITATE NEW SPLASH PAD LAYOUT, TYP. <br />ENSURE 100% IRRIGATION COVERAGE <br />AT EXISTING TURF AREAS <br />2 <br />REPLACE NOZZLES AT EXISTING ROTORS TO <br />FACILITATE NEW SPLASH PAD LAYOUT, TYP. <br />ENSURE 100% IRRIGATION COVERAGE <br />AT EXISTING TURF AREAS <br />EX. IRRIGATION ECV. <br />22 57