Laserfiche WebLink
IRRIGATION DETAILS <br />NUMBER DATE INITIALS DESCRIPTION <br />PREPARED UNDER THE <br />SUPERVISION OF: <br />CITY OF SANTA ANA <br />FILE NO.: <br />INSTALLEDAPPROVED <br />CONSTRUCTION COMPLETED: <br />BENCHMARK NO.: SA-253-70 <br />RECOMMENDED FOR <br />CONSTRUCTION: <br />REFERENCES <br />PUBLIC WORKS AGENCY <br />XRCE NO.: <br />ELEV.: 176.00 (2010) <br />REVISIONS <br />SHEET OF <br />BENCHMARK DESCRIPTION: <br />OCS BM SA-253-70 <br />FD 3 3/4" OCS ALUMINUM BENCH MARK DISK STAMPED "SA-253-70", SET IN NW'LY CORNER OF A 3.5FT X 16FT <br />CONCRETE CATCH BASIN. MONUMENT IS LOCATED IN THE NE'LY CORNER OF THE INTERSECTION OF GRAND AVE <br />AND SANTA CLARA AVE, 87FT N'LY OF THE CENTERLINE OF SANTA CLARA AVE AND 39FT E'LY OF THE CENTERLINE <br />OF GRAND AVE. MONUMENT IS SET LEVEL WITH THE SIDEWALK <br />PORTOLA PARK <br />SPLASH PADREVIEWED FOR <br />CONSTRUCTABLITY: <br />PRINCIPAL CIVIL ENGINEER <br />DESIGNED: <br />PRINCIPAL CIVIL ENGINEER RCE NO.: <br />ES MM ES <br />LANDSCAPE ARCHITECT <br />DRAWN:CHECKED: <br />PS- <br />2 <br />5 <br />- <br />2 <br />4 <br />0 <br />1 <br />GARY VASQUEZ <br />1700 E. SANTA CLARA AVENUE, SANTA ANA, CA 92705 <br />811 <br />UNDERGROUND SERVICE ALERT. DIAL 811 <br />LOCATION OF UNDERGROUND UTILITIES BY CONTRACTING <br />BEFORE EXCAVATING, THE CONTRACTOR SHALL VERIFY THE <br />DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICE. <br />UNDERGROUND FACILITIES PRIOR TO DOING WORK THAT MAY <br />STEPS TO ASCERTAIN THE EXACT LOCATION OF ALL <br />THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE <br />DIFFERENT FROM THAT WHICH IS SHOWN ON THE PLANS OR IN <br />UNDERGROUND FACILITIES NOT KNOWN OR IN A LOCATION <br />ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF <br />UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA <br />11/26/25 <br />LICENSED LANDSCAPE ARCHITECT <br />SIGNATUREGARY M. VASQUEZ #3883 <br />DATE <br />RENEWAL DATE <br />02/2027 <br />AINROFILACFOETATS <br />DVDCreative <br />151 Kalmus Drive, Suite M8 <br />Costa Mesa, CA 92626 <br />714.641.1300 <br />dvdcreative.com <br />PO <br />R <br />T <br />O <br />L <br />A <br /> <br />P <br />A <br />R <br />K <br /> <br />S <br />P <br />L <br />A <br />S <br />H <br /> <br />P <br />A <br />D <br /> <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />O <br />. <br /> <br />2 <br />5 <br />- <br />2 <br />4 <br />0 <br />1 <br />L-750 <br />GATE VALVE 1" = 1'-0" <br />2" MIN CLR. <br />COMMON BRICK <br />SUPPORTS - 3 REQUIRED <br />3/4" CRUSHED GRAVEL - 6" DEEP <br />BELOW VALVE AND LEVEL WITH <br />CONTROL NUT <br />LANDSCAPE FABRIC - WRAP SIDES AND <br />BOX BOTTOM - COVER ALL OPENINGS <br />PVC MAIN LINE PIPING <br />PVC PIPE EXTENSION <br />SLEEVE - 6-INCH DIA. - <br />CLASS 200 OR SCHEDULE <br />40 PVC <br />GATE VALVE - PUSH-ON <br />MECHANICAL JOINT <br />CONNECTIONS <br />1" IN TURF AND <br />3" IN PLANTING AREA <br />FINISH GRADE <br />NOTE: <br />1.INSTALL VALVE BOX AND EXTENSION AS REQUIRED TO POSITION VALVE AT MAIN LINE PIPE DEPTH. <br />BOLT-DOWN ROUND VALVE BOX WITH STAINLESS <br />STEEL HARDWARE - GREEN IN COLOR - HEAT BRAND <br />THE LETTERS 'BV' WITH 2" TALL CHARACTERS <br />1 <br />P-SA-24.036-21 <br />ELECTRIC CONTROL VALVE N.T.S. <br />SECTION <br />1" IN TURF AND <br />3" IN PLANTING AREA <br />FINISH GRADE <br />CONTROL/ COMMON WIRES - <br />COIL 36" MINIMUM LENGTH <br />OF WIRES IN BOX <br />COMMON BRICK <br />SUPPORTS - 4 REQUIRED <br />PVC PIPE TO SPRINKLERS - <br />ANGLE PIPE WITH SPECIFIED <br />DEPTH W/ 45 DEGREE ELBOWS <br />AS REQUIRED <br />LANDSCAPE FABRIC BELOW GRAVEL - <br />WRAP SIDES BOX BOTTOM <br />AND COVER ALL OPENINGS <br />3/4" CRUSHED GRAVEL <br />BASE - 8" DEPTH <br />SCHEDULE 80 PVC <br />SLIP FITTING - LINE SIZE <br />SCHEDULE 80 PVC T.O.E. (THREADED ONE END) <br />AND SLIP FIT ELL - LINE SIZE <br />SCHEDULE 80 PVC NIPPLE - VALVE SIZE <br />2" <br /> <br />M <br />I <br />N <br />. <br />CL <br />R <br />. <br />PVC MAIN LINE <br />PIPING <br />SCHEDULE 80 PVC <br />SLIP FITTING - LINE SIZE <br />SCHEDULE 80 PVC <br />SLIP FITTING - LINE SIZE <br />CHRISTY'S I.D. TAG - SEQUENCED <br />TO MATCH DRAWINGS <br />WATERPROOF WIRE CONNECTOR - <br />2 REQUIRED <br />ELECTRIC CONTROL VALVE <br />RECTANGULAR VALVE BOX - BOLT DOWN LOCKING <br />COVER - GREEN IN COLOR - HEAT BRAND VALVE <br />STATION NUMBER ON COVER IN 2" HIGH CHARACTERS <br />2 <br />P-SA-24.036-22 <br />NOTE: <br />THE ENDS OF THE CONDUIT <br />SHALL REMAIN CAPPED UNTIL <br />THE INSTALLATION OF CABLE <br />SIGNAL CABLE PULL BOX N.T.S. <br />SECTION <br />CURB, WALK OR OTHER <br />HARDSCAPE <br />12" MIN. <br />FINISH GRADE <br />2" <br />MI <br />N <br />. <br />30 <br />" <br />1" IN TURF AND <br />3" IN PLANTING AREA <br />SxS COUPLING - UL LISTED <br />SCHEDULE 40 PVC - 4 REQUIRED CABLE CONDUIT - UL LISTED <br />SCHEDULE 40 PVC <br />SWEEP ELL 90 - UL LISTED <br />SCHEDULE 40 PVC <br />3/4" CRUSHED GRAVEL <br />BASE - 8" DEPTH <br />COMMON BRICK <br />SUPPORTS - 4 REQUIRED <br />LANDSCAPE FABRIC BELOW GRAVEL - <br />WRAP SIDES BOX BOTTOM <br />AND COVER ALL OPENINGS <br />CONDUIT BUSHING - SEAL ENDS <br />W/ SPRAY FOAM <br />BOLT DOWN ROUND VALVE BOX - GREEN IN COLOR - <br />HEAT BRAND THE LETTERS 'PB' ON COVER IN 2" <br />HIGH CHARACTERS PER SPECIFICATIONS <br />PERMANENT IDENTIFICATION BAND <br />SIGNAL CABLE - WITH 24" EXPANSION LOOP <br />3 <br />P-SA-24.036-23 <br />VALVE BOX LAYOUT N.T.S. <br />PLAN VIEW <br />ROUND VALVE BOX <br />STANDARD RECTANGULAR <br />VALVE BOX, TYP. <br />JUMBO RECTANGULAR <br />VALVE BOX, TYP. <br />TURF <br />EDGE OF CURB, PAVEMENT, <br />FENCE, ETC. <br />NOTES: <br />1.CENTER VALVE BOX OVER VALVE <br />TO FACILITATE SERVICE OF VALVE. <br />2.VALVE BOXES INSTALLED ONLY <br />WHERE PERMITTED. <br />3.SET VALVE BOXES PARALLEL TO <br />ONE ANOTHER AND <br />PERPENDICULAR TO THE EDGE. <br />4.AVOID HEAVY COMPACTION OF <br />SOIL AROUND VALVE BOXES TO <br />PREVENT DEFORMATION/ <br />COLLAPSE OF VALVE BOX BASES. <br />24 <br />" <br />24 <br />" <br />24 <br />" <br />24 <br />" <br />18" <br />4 <br />P-SA-24.036-24 <br />3M "DBR/Y-6" WIRE CONNECTOR N.T.S. <br />STRIP WIRE INSULATION <br />FROM ENDS <br />PER <br />MFR. <br />INSERT WIRE ENDS INTO THE CONNECTOR <br />AND TWIST IN A CLOCKWISE DIRECTION <br />UNTIL SECURE <br />INSERT CONNECTOR INTO INSULATOR TUBE <br />AND PUSH UNTIL IT SNAPS IN PLACE AT THE BASE <br />POSITION WIRES IN WIRE CHANNEL <br />SNAP INSULATOR TUBE <br />COVER CLOSED <br />5 <br />P-SA-24.036-25 <br />POP-UP SPRINKLER N.T.S. <br />SECTION <br />PLAN VIEW <br />POP-UP SPRAY HEAD <br />OR ROTOR <br />1/2" IN TURF <br />2" IN PLANTING AREA <br />FINISH GRADE <br />24" IN TURF AND PLANTING AREA <br />12" FROM VERTICAL SURFACES <br />ADJACENT PAVING EDGE OR CURB <br />POP-UP SPRAY HEAD <br />OR ROTOR <br />SCHEDULE 40 PVC <br />STREET ELL - TYPICAL <br />SCHEDULE 40 PVC TxT ELL <br />LATERAL LINE PIPING AND FITTING <br />LATERAL LINE PIPING AND FITTING <br />SCHEDULE 40 PVC <br />STREET ELL - TYPICAL <br />SCHEDULE 80 PVC NIPPLE - <br />6" MINIMUM AND 12" MAXIMUM LENGTH <br />LATERAL LINE PIPING AND FITTING <br />SCHEDULE 40 PVC TxT ELL <br />SCHEDULE 80 PVC SHORT NIPPLE <br />NOTE: <br />1.USE TEFLON TAPE ON ALL THREADED FITTINGS. <br />6 <br />P-SA-24.036-26 <br />PIPE INSTALLATION N.T.S. <br />SECTION <br />6" <br />CLR. <br />6"6"6" <br />12 <br />" <br /> <br />M <br />I <br />N <br />. <br />CURB, PAVING <br />OR WALL - TYPICALFINISH GRADE <br />CLEAN COMPACTED BACKFILL - SEE SPECIFICATIONS <br />FOR BACKFILL AND COMPACTION REQUIREMENTS <br />UNDISTURBED SOIL <br />PRESSURE MAIN <br />LINE PIPING <br />CONTROL WIRES - BUNDLE AND <br />TAPE EVERY 10 LINEAR-FEET - <br />INSTALL ADJACENT TO PRESSURE <br />MAINLINE PIPING <br />FLOW SENSOR SIGNAL <br />CABLE CONDUIT <br />PROVIDE 2" DEPTH OF CLEAN <br />BACKFILL BELOW PIPING - TYPICAL <br />18" MIN. FOR PIPE <br />SIZE 2-1/2" AND <br />SMALLER <br />24" MIN. FOR PIPE <br />SIZE 3" AND LARGER <br />NON-PRESSURE LATERAL LINE PIPING <br />PROVIDE 2" DEPTH OF CLEAN <br />BACKFILL BELOW PIPING - TYPICAL <br />7 <br />P-SA-24.036-27 <br />23 57