My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2501 S Pullman St Ste 200 & 201 - Plan
PBA
>
Building
>
ProjectDox
>
P
>
Pullman St
>
2501 S Pullman St Unit# 201
>
2501 S Pullman St Ste 200 & 201 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/6/2026 5:00:22 AM
Creation date
5/6/2026 5:00:04 AM
Metadata
Fields
Template:
Plan
Permit Number
20187228
30149480
40140893
101125490
101125491
Full Address
2501 S Pullman St Unit# 201
2501 S Pullman St Unit# 200
Street Number
2501
Street Direction
S
Street Name
Pullman
Street Suffix
St
Unit Number
201
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
81
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
10 <br /> <br /> <br />E <br />d <br />e <br />l <br />m <br />a <br />n <br />Ir <br />v <br />i <br />n <br />e <br />, <br /> <br />C <br />A <br />, <br /> <br />9 <br />2 <br />6 <br />1 <br />8 <br />P <br />9 <br />4 <br />9 <br />. <br />6 <br />6 <br />0 <br />. <br />9 <br />1 <br />2 <br />8 <br /> <br /> <br /> <br />JOB NO.: <br />DRAWN BY.: <br />PA/PM: <br />SHEET <br />TH <br />E <br />S <br />E <br /> <br />D <br />R <br />A <br />W <br />I <br />N <br />G <br />S <br /> <br />A <br />N <br />D <br /> <br />S <br />P <br />E <br />C <br />I <br />F <br />I <br />C <br />A <br />T <br />I <br />O <br />N <br />S <br /> <br />A <br />R <br />E <br /> <br />T <br />H <br />E <br /> <br />P <br />R <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />AN <br />D <br /> <br />C <br />O <br />P <br />Y <br />R <br />I <br />G <br />H <br />T <br /> <br />O <br />F <br /> <br />W <br />A <br />R <br />E <br /> <br />M <br />A <br />L <br />C <br />O <br />M <br />B <br /> <br />A <br />N <br />D <br /> <br />S <br />H <br />A <br />L <br />L <br /> <br />N <br />O <br />T <br /> <br />B <br />E <br /> <br />U <br />S <br />E <br />D <br /> O <br />N <br /> <br />A <br />N <br />Y <br /> <br />O <br />T <br />H <br />E <br />R <br /> <br />W <br />O <br />R <br />K <br /> <br />E <br />X <br />C <br />E <br />PT <br /> <br />B <br />Y <br /> <br />A <br />G <br />R <br />E <br />E <br />M <br />E <br />N <br />T <br /> <br />W <br />I <br />T <br />H <br /> <br />W <br />A <br />R <br />E <br /> <br />M <br />A <br />L <br />C <br />O <br />M <br />B <br />. <br /> <br />W <br />R <br />I <br />T <br />T <br />E <br />N <br /> <br />D <br />I <br />M <br />E <br />N <br />S <br />I <br />O <br />NS <br /> <br />S <br />H <br />A <br />L <br />L <br /> <br />T <br />A <br />K <br />E <br /> <br />P <br />R <br />E <br />C <br />E <br />D <br />E <br />N <br />C <br />E <br /> <br />O <br />V <br />E <br />R <br /> <br />S <br />C <br />A <br />L <br />E <br />D <br /> <br />D <br />I <br />M <br />E <br />N <br />S <br />I <br />O <br />N <br />S <br /> <br />A <br />N <br />D <br /> S <br />H <br />A <br />L <br />L <br /> <br />B <br />E <br /> <br />V <br />E <br />R <br />I <br />F <br />I <br />E <br />D <br /> <br />O <br />N <br /> <br />T <br />HE <br /> <br />J <br />O <br />B <br />S <br />I <br />T <br />E <br />. <br /> <br />A <br />N <br />Y <br /> <br />D <br />I <br />S <br />C <br />R <br />E <br />P <br />A <br />N <br />C <br />Y <br /> <br />S <br />H <br />A <br />L <br />L <br /> <br />B <br />E <br /> <br />B <br />R <br />O <br />U <br />G <br />H <br />T <br /> <br />T <br />O <br /> <br />T <br />H <br />E <br /> <br />N <br />O <br />T <br />IC <br />E <br /> <br />O <br />F <br /> <br />W <br />A <br />R <br />E <br /> <br />M <br />A <br />L <br />C <br />O <br />M <br />B <br /> <br />P <br />R <br />I <br />O <br />R <br /> <br />T <br />O <br /> <br />T <br />H <br />E <br /> <br />C <br />O <br />M <br />M <br />E <br />N <br />C <br />E <br />M <br />E <br />N <br />T <br /> <br />O <br />F <br /> <br />A <br />N <br />Y <br />W <br />O <br />R <br />K <br />CAUTION:IF THIS SHEET IS NOT 30"x42" IT IS A REDUCED PRINT <br />Au <br />t <br />o <br />d <br />e <br />s <br />k <br /> <br />D <br />o <br />c <br />s <br />: <br />/ <br />/ <br />I <br />R <br />V <br />2 <br />5 <br />- <br />6 <br />0 <br />1 <br />7 <br />- <br />0 <br />0 <br />_ <br />F <br />u <br />j <br />i <br /> <br />F <br />i <br />s <br />i <br /> <br />- <br />I <br />r <br />v <br />i <br />n <br />e <br /> <br />S <br />c <br />i <br /> <br />2 <br />5 <br />0 <br />1 <br /> <br />P <br />u <br />l <br />l <br />m <br />a <br />n <br />/ <br />6 <br />0 <br />1 <br />7 <br />_ <br />A <br />R <br />C <br />H <br />- <br />T <br />I <br />. <br />r <br />v <br />t <br />3/ <br />5 <br />/ <br />2 <br />0 <br />2 <br />6 <br /> <br />1 <br />1 <br />: <br />5 <br />1 <br />: <br />0 <br />6 <br /> <br />A <br />M <br />Approver <br />Author <br />IRV25-6017 <br />CA <br />L <br />G <br />R <br />E <br />E <br />N <br /> <br />N <br />O <br />T <br />E <br />S <br />I033 <br />FU <br />J <br />I <br />F <br />I <br />L <br />M <br /> <br />- <br />FI <br />S <br />I <br />25 <br />0 <br />1 <br /> <br />P <br />U <br />L <br />L <br />M <br />A <br />N <br /> <br />S <br />T <br /> <br />S <br />U <br />I <br />T <br />E <br /> <br />2 <br />0 <br />1 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />5.507.4.3 INTERIOR SOUND TRANSMISSION <br />WALL AND FLOOR-CEILING ASSEMBLIES SEPARATING TENANT SPACES AND TENANT <br />SPACES AND PUBLIC PLACES SHALL HAVE AN STC OF AT LEAST 40. <br />NOTE: EXAMPLES OF ASSEMBLIES AND THEIR VARIOUS STC RATINGS MAY BE FOUND <br />AT THE CALIFORNIA OFFICE OF NOISE CONTROL: <br />HTTP://WWW.TOOLBASE.ORG/PDF/CASESTUDIES/STC_ICC_RATINGS.PDF. <br />N/A <br />5.508.1 OZONE DEPLETION AND GREENHOUSE GAS REDUCTIONS. <br />INSTALLATIONS OF HVAC, REFRIGERATION AND FIRE SUPPRESSION EQUIPMENT <br />SHALL COMPLY WITH SECTIONS 5.508.1.1 AND 5.508.1.2. <br />N/A <br />5.508.1.1 CHLOROFLUOROCARBONS (CFCs). <br />INSTALL HVAC, REFRIGERATION AND FIRE SUPPRESSION EQUIPMENT THAT DO <br />NOT CONTAIN CFCS. <br />N/A <br />5.508.1.2 HALONS. <br />N/A <br />INSTALL HVAC,REFRIGERATION AND FIRE SUPPRESSION EQUIPMENT THAT DO <br />NOT CONTAIN HALONS. <br />5.508.2 SUPERMARKET REFRIGERANT LEAK REDUCTION. <br />NEW COMMERCIAL REFRIGERATION SYSTEMS SHALL COMPLY WITH THE PROVISIONS <br />OF THIS SECTION WHEN INSTALLED IN RETAIL FOOD STORES 8,000 SQUARE FEET OR <br />MORE CONDITIONED AREA, AND THAT UTILIZE EITHER REFRIGERATED DISPLAY CASES, <br />OR WALK-IN COOLERS OR FREEZERS CONNECTED TO REMOTE COMPRESSOR UNITS <br />OR CONDENSING UNITS. THE LEAK REDUCTION MEASURES APPLY TO REFRIGERATION <br />SYSTEMS CONTAINING HIGH-GLOBAL-WARMING POTENTIAL (HIGH-GWP) REFRIGERANTS <br />WITH A GWP OF 150 OR GREATER. NEW REFRIGERATION SYSTEMS INCLUDE BOTH NEW <br />FACILITIES AND THE REPLACEMENT OF EXISTING REFRIGERATION SYSTEMS IN <br />EXISTING FACILITIES. <br />EXCEPTION: REFRIGERATION SYSTEMS CONTAINING LOW-GLOBAL WARMING POTENTIAL <br />(LOW-GWP) REFRIGERANT WITH A GWP VALUE LESS THAN 150 ARE NOT SUBJECT TO THIS <br />SECTION. LOW-GWP REFRIGERANTS ARE NONOZONE-DEPLETING REFRIGERANTS THAT <br />INCLUDE AMMONIA, CARBON DIOXIDE (CO2), AND POTENTIALLY OTHER REFRIGERANTS. <br />5.507.4.1.1 NOISE EXPOSURE WHERE NOISE CONTOURS ARE <br />NOT READILY AVAILABLE <br />BUILDINGS EXPOSED TO A NOISE LEVEL OF 65 DB LEQ-1-HR DURING ANY HOUR OF <br />OPERATION SHALL HAVE BUILDING, ADDITION OR ALTERATION EXTERIOR W ALL <br />AND ROOF-CEILING ASSEMBLIES EXPOSED TO THE NOISE SOURCE MEETING A <br />COMPOSITE STC RATING OF AT LEAST 45 (OR OITC 35), WITH EXTERIOR WINDOWS <br />OF A MINIMUM STC OF 40 (OR OITC 30). <br />N/A <br />5.507.4.2 PERFORMANCE METHOD <br />FOR BUILDINGS LOCATED AS DEFINED IN SECTION 5.507.4.1 OR 5.507.4.1.1, WALL AND <br />ROOF-CEILING ASSEMBLIES EXPOSED TO THE NOISE SOURCE MAKING UP THE <br />BUILDING OR ADDITION ENVELOPE OR ALTERED ENVELOPE SHALL BE CONSTRUCTED <br />TO PROVIDE AN INTERIOR NOISE ENVIRONMENT ATTRIBUTABLE TO EXTERIOR <br />SOURCES THAT DOES NOT EXCEED AN HOURLY EQUIVALENT NOISE LEVEL (L eq - <br />1-Hr) OF 50 DBA IN OCCUPIED AREAS DURING ANY HOUR OF OPERATION. <br />5.507.4.2.1 SITE FEATURES <br />EXTERIOR FEATURES SUCH AS SOUND WALLS OR EARTH BERMS MAY BE UTILIZED <br />AS APPROPRIATE TO THE BUILDING, ADDITION OR ALTERATION PROJECT TO <br />MITIGATE SOUND MIGRATION TO THE NTERIOR. <br />N/A <br />5.507.4.2.2 DOCUMENTATION OF COMPLIANCE <br />AN ACOUSTICAL ANALYSIS DOCUMENTING COMPLYING INTERIOR SOUND LEVELS <br />SHALL BE PREPARED BY PERSONNEL APPROVED BY THE ARCHITECT OR <br />ENGINEER OF RECORD. <br />N/A <br />N/A <br />5.508.2.1 REFRIGERANT PIPING. <br />PIPING COMPLIANT WITH THE CALIFORNIA MECHANICAL CODE SHALL BE <br />INSTALLED TO BE ACCESSIBLE FOR LEAK PROTECTION AND REPAIRS. PIPING <br />RUNS USING THREADED PIPE, COPPER TUBING WITH AN OUTSIDE DIAMETER (OD) <br />LESS THAN 1/4 INCH, FLARED TUBING CONNECTIONS AND SHORT RADIUS ELBOWS <br />SHALL NOT BE USED IN REFRIGERANT SYSTEMS EXCEPT AS NOTED BELOW. <br />5.508.2.1.1 THREADED PIPE. <br />THREADED CONNECTIONS ARE PERMITTED AT THE COMPRESSOR RACK. <br />5.508.2.1.2 COPPER PIPE. <br />COPPER TUBING WITH AN OD LESS THAN 1/4 INCH MAY BE USED IN SYSTEMS <br />WITH A REFRIGERANT CHARGE OF 5 POUNDS OR LESS. <br />5.508.2.1.2.1 ANCHORAGE. <br />ONE-FOURTH-INCH OD TUBING SHALL BE SECURELY CLAMPED TO A RIGID <br />BASE TO KEEP VIBRATION LEVELS BELOW 8 MILS. <br />5.508.2.1.3 FLARED TUBING CONNECTIONS. <br />DOUBLE-FLARED TUBING CONNECTIONS MAY BE USED FOR PRESSURE <br />CONTROLS, VALVE PILOT LINES AND OIL. <br />EXCEPTION:SINGLE-FLARED TUBING CONNECTIONS MAY BE USED WITH A <br /> MULTIRING SEAL COATED WITH INDUSTRIAL SEALANT <br /> SUITABLE FOR USE WITH REFRIGERANTS AND TIGHTENED IN <br /> ACCORDANCE WITH MANUFACTURER’S RECOMMENDATIONS. <br />5.508.2.1.4 ELBOWS. <br />SHORT RADIUS ELBOWS ARE ONLY PERMITTED WHERE SPACE LIMITATIONS <br />PROHIBIT USE OF LONG RADIUS ELBOWS. <br />5.508.2.2 VALVES. <br />VALVES AND FITTINGS SHALL COMPLY WITH THE CALIFORNIA MECHANICAL CODE <br />AND AS FOLLOWS. <br />5.508.2.2.1 PRESSURE RELIEF VALVES. <br />FOR VESSELS CONTAINING HIGH-GWP REFRIGERANT, A RUPTURE DISC SHALL BE <br />INSTALLED BETWEEN THE OUTLET OF THE VESSEL AND THE INLET OF THE <br />PRESSURE RELIEF VALVE. <br />5.508.2.2.1.1 PRESSURE DETECTION. <br />A PRESSURE GAUGE, PRESSURE TRANSDUCER OR OTHER DEVICE SHALL <br />BE INSTALLED IN THE SPACE BETWEEN THE RUPTURE DISC AND THE <br />RELIEF VALVE INLET TO INDICATE A DISC RUPTURE OR DISCHARGE OF THE <br />RELIEF VALVE. <br />5.508.2.2.2 ACCESS VALVES. <br />ONLY SCHRADER ACCESS VALVES WITH A BRASS OR STEEL BODY ARE PERMITTED <br />FOR USE. <br />5.508.2.2.2.1 VALVE CAPS. <br />FOR SYSTEMS WITH A REFRIGERANT CHARGE OF 5 POUNDS OR MORE, VALVE <br />CAPS SHALL BE BRASS OR STEEL AND NOT PLASTIC. <br />5.508.2.2.2.2 SEAL CAPS. <br />IF DESIGNED FOR IT, THE CAP SHALL HAVE A NEOPRENE O-RING IN PLACE. <br />5.508.2.2.2.2.1 CHAIN TETHERS. <br />CHAIN TETHERS TO FIT OVER THE STEM ARE REQUIRED FOR VALVES <br />DESIGNED TO HAVE SEAL CAPS. <br />EXCEPTION: VALVES WITH SEAL CAPS THAT ARE NOT REMOVED FROM <br />THE VALVE DURING STEM OPERATION. <br />5.508.2.3 REFRIGERATED SERVICE CASES. <br />REFRIGERATED SERVICE CASES HOLDING FOOD PRODUCTS CONTAINING VINEGAR <br />AND SALT SHALL HAVE EVAPORATOR COILS OF CORROSION-RESISTANT MATERIAL, <br />SUCH AS STAINLESS STEEL; OR BE COATED TO PREVENT CORROSION FROM THESE <br />SUBSTANCES. <br />5.508.2.3.1 COIL COATING. <br />CONSIDERATION SHALL BE GIVEN TO THE HEAT TRANSFER EFFICIENCY OF COIL <br />COATING TO MAXIMIZE ENERGY EFFICIENCY. <br />5.508.2.4 REFRIGERANT RECEIVERS. <br />REFRIGERANT RECEIVERS WITH CAPACITIES GREATER THAN 200 POUNDS SHALL BE <br />FITTED WITH A DEVICE THAT INDICATES THE LEVEL OF REFRIGERANT IN THE <br />RECEIVER. <br />5.508.2.5 PRESSURE TESTING. <br />THE SYSTEM SHALL BE PRESSURE TESTED DURING INSTALLATION PRIOR TO <br />EVACUATION AND CHARGING. <br />5.508.2.5.1 MINIMUM PRESSURE. <br />THE SYSTEM SHALL BE CHARGED WITH REGULATED DRY NITROGEN AND <br />APPROPRIATE TRACER GAS TO BRING SYSTEM PRESSURE UP TO 300 PSIG <br />MINIMUM. <br />5.508.2.5.2 LEAKS. <br />CHECK THE SYSTEM FOR LEAKS, REPAIR ANY LEAKS AND RETEST FOR PRESSURE <br />USING THE SAME GAUGE. <br />5.508.2.5.3 ALLOWABLE PRESSURE CHANGE. <br />THE SYSTEM SHALL STAND, UNALTERED, FOR 24 HOURS WITH NO MORE THAN A <br />+/-ONE POUND PRESSURE CHANGE FROM 300 PSIG, MEASURED WITH THE SAME <br />GAUGE. <br />5.508.2.6 EVACUATION. <br />THE SYSTEM SHALL BE EVACUATED AFTER PRESSURE TESTING AND PRIOR TO <br />CHARGING. <br />5.508.2.6.1 FIRST VACUUM. <br />PULL A SYSTEM VACUUM DOWN TO AT LEAST 1000 MICRONS (+/-50 MICRONS), AND <br />HOLD FOR 30 MINUTES. <br />5.508.2.6.2 SECOND VACUUM. <br />PULL A SECOND SYSTEM VACUUM TO A MINIMUM OF 500 MICRONS AND HOLD FOR <br />30 MINUTES. <br />5.508.2.6.3 THIRD VACUUM. <br />PULL A THIRD VACUUM DOWN TO A MINIMUM OF 300 MICRONS, AND HOLD FOR <br />24 HOURS WITH A MAXIMUM DRIFT OF 100 MICRONS OVER A 24-HOUR PERIOD. <br />SECTION 5.508 OUTDOOR AIR QUALITY <br />CHAPTER 7 <br />INSTALLER & SPECIAL INSPECTOR <br />QUALIFICATIONS <br />SECTION 702 QUALIFICATIONS <br />702.1 INSTALLER TRAINING. <br />702.2 SPECIAL INSPECTION [HCD]. <br />SECTION 703 VERIFICATIONS <br />703.1 DOCUMENTATION. <br />HVAC SYSTEM INSTALLERS SHALL BE TRAINED AND CERTIFIED IN THE PROPER INSTALLATION <br />OF HVAC SYSTEMS INCLUDING DUCTS AND EQUIPMENT BY A NATIONALLY OR REGIONALLY <br />RECOGNIZED TRAINING OR CERTIFICATION PROGRAM. UNCERTIFIED PERSONS MAY PERFORM <br />HVAC INSTALLATIONS WHEN UNDER THE DIRECT SUPERVISION AND RESPONSIBILITY OF A <br />PERSON TRAINED AND CERTIFIED TO INSTALL HVAC SYSTEMS OR CONTRACTOR LICENSED TO <br />INSTALL HVAC SYSTEMS. EXAMPLES OF ACCEPTABLE HVAC TRAINING AND CERTIFICATION <br />PROGRAMS INCLUDE BUT ARE NOT LIMITED TO THE FOLLOWING: <br />1. STATE CERTIFIED APPRENTICESHIP PROGRAMS. <br />2. PUBLIC UTILITY TRAINING PROGRAMS. <br />3. TRAINING PROGRAMS SPONSORED BY TRADE, LABOR OR STATEWIDE ENERGY <br /> CONSULTING OR VERIFICATION ORGANIZATIONS. <br />4. PROGRAMS SPONSORED BY MANUFACTURING ORGANIZATIONS. <br />5. OTHER PROGRAMS ACCEPTABLE TO THE ENFORCING AGENCY. <br />[HCD] WHEN REQUIRED BY THE ENFORCING AGENCY, THE OW NER OR THE RESPONSIBLE <br />ENTITY ACTING AS THE OWNER’S AGENT SHALL EMPLOY ONE OR MORE SPECIAL INSPECTORS <br />TO PROVIDE INSPECTION OR OTHER DUTIES NECESSARY TO SUBSTANTIATE COMPLIANCE <br />WITH THIS CODE. SPECIAL INSPECTORS SHALL DEMONSTRATE COMPETENCE TO THE <br />SATISFACTION OF THE ENFORCING AGENCY FOR THE PARTICULAR TYPE OF INSPECTION OR <br />TASK TO BE PERFORMED. IN ADDITION TO OTHER CERTIFICATIONS OR QUALIFICATIONS <br />ACCEPTABLE TO THE ENFORCING AGENCY, THE FOLLOWING CERTIFICATIONS OR EDUCATION <br />MAY BE CONSIDERED BY THE ENFORCING AGENCY WHEN EVALUATING THE QUALIFICATIONS <br />OF A SPECIAL INSPECTOR: <br />1. CERTIFICATION BY A NATIONAL OR REGIONAL GREEN BUILDING PROGRAM OR STANDARD <br /> PUBLISHER. <br />2. CERTIFICATION BY A STATEWIDE ENERGY CONSULTING OR VERIFICATION <br /> ORGANIZATION, SUCH AS HERS RATERS, BUILDING PERFORMANCE CONTRACTORS AND <br /> HOME ENERGY AUDITORS. <br />3. SUCCESSFUL COMPLETION OF A THIRD PARTY APPRENTICE TRAINING PROGRAM IN THE <br /> APPROPRIATE TRADE. <br />4. OTHER PROGRAMS ACCEPTABLE TO THE ENFORCING AGENCY. <br />NOTES: <br />1. SPECIAL INSPECTORS SHALL BE INDEPENDENT ENTITIES WITH NO FINANCIAL INTEREST <br /> IN THE MATERIALS OR THE PROJECT THEY ARE INSPECTING FOR COMPLIANCE WITH THIS <br /> CODE. <br />2. HERS RATERS ARE SPECIAL INSPECTORS CERTIFIED BY THE CALIFORNIA ENERGY <br /> COMMISSION (CEC) TO RATE HOMES IN CALIFORNIA ACCORDING TO THE HOME ENERGY <br /> RATING SYSTEM (HERS). <br />[BSC-CG] WHEN REQUIRED BY THE ENFORCING AGENCY, THE OWNER OR THE RESPONSIBLE <br />ENTITY ACTING AS THE OWNER’S AGENT SHALL EMPLOY ONE OR MORE SPECIAL INSPECTORS <br />TO PROVIDE INSPECTION OR OTHER DUTIES NECESSARY TO SUBSTANTIATE COMPLIANCE <br />WITH THIS CODE. SPECIAL INSPECTORS SHALL DEMONSTRATE COMPETENCE TO THE <br />SATISFACTION OF THE ENFORCING AGENCY FOR THE PARTICULAR TYPE OF INSPECTION OR <br />TASK TO BE PERFORMED. IN ADDITION, THE SPECIAL INSPECTOR SHALL HAVE A CERTIFICATION <br />FROM A RECOGNIZED STATE, NATIONAL OR INTERNATIONAL ASSOCIATION, AS DETERMINED BY <br />THE LOCAL AGENCY. THE AREA OF CERTIFICATION SHALL BE CLOSELY RELATED TO THE <br />PRIMARY JOB FUNCTION, AS DETERMINED BY THE LOCAL AGENCY. <br />NOTE:SPECIAL INSPECTORS SHALL BE INDEPENDENT ENTITIES WITH NO FINANCIAL <br /> INTEREST IN THE MATERIALS OR THE PROJECT THEY ARE INSPECTING FOR <br /> COMPLIANCE WITH THIS CODE. <br />DOCUMENTATION USED TO SHOW COMPLIANCE WITH THIS CODE SHALL INCLUDE BUT IS NOT <br />LIMITED TO, CONSTRUCTION DOCUMENTS, PLANS, SPECIFICATIONS, BUILDER OR INSTALLER <br />CERTIFICATION, INSPECTION REPORTS OR OTHER METHODS ACCEPTABLE TO THE ENFORCING <br />AGENCY WHICH DEMONSTRATE SUBSTANTIAL CONFORMANCE. W HEN SPECIFIC <br />DOCUMENTATION OR SPECIAL INSPECTION IS NECESSARY TO VERIFY COMPLIANCE, THAT <br />METHOD OF COMPLIANCE WILL BE SPECIFIED IN THE APPROPRIATE SECTION OR IDENTIFIED IN <br />THE APPLICATION CHECKLIST. <br />2022 CALIFORNIA GREEN BUILDING STANDARDS CODE - NONRESIDENTIAL MANDATORY MEASURES <br />DIVISION 5.5 – ENVIRONMENTAL QUALITY <br />(CONTINUED) <br />5.507 ENVIRONMENTAL COMFORT (CONTINUED) <br />DA <br />T <br />E <br /> <br />R <br />E <br />M <br />A <br />R <br />K <br />S <br />08 <br />/ <br />2 <br />5 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />I <br />S <br />S <br />U <br />E <br />D <br /> <br />F <br />O <br />R <br /> <br />P <br />E <br />R <br />M <br />I <br />T <br />11 <br />/ <br />3 <br />0 <br />/ <br />2 <br />0 <br />2 <br />5 <br />11 <br />/ <br />3 <br />0 <br />/ <br />2 <br />0 <br />2 <br />7 <br />03 <br />/ <br />0 <br />5 <br />/ <br />2 <br />0 <br />2 <br />6 <br /> <br /> <br />- <br /> <br /> <br />P <br />L <br />A <br />N <br /> <br />C <br />H <br />E <br />C <br />K <br /> <br />R <br />E <br />S <br />U <br />B <br />M <br />I <br />T <br />T <br />A <br />L
The URL can be used to link to this page
Your browser does not support the video tag.