Laserfiche WebLink
13:12 <br />SLOPE <br />13:12 <br />SLOPE <br />13:12 <br />SLOPE <br />13:12 <br />SLOPE <br />13:12 <br />SLOPE <br />13:12 <br />SLOPE <br />6:12 <br />SLOPE <br />13:12 <br />SLOPE <br />13:12 <br />SLOPE <br />6:12 <br />SLOPE <br />6:12 <br />SLOPE <br />6:12 <br />SLOPE <br />13:12 <br />SLOPE <br />13:12 <br />SLOPE <br />13:12 <br />SLOPE <br />13:12 <br />SLOPE <br />13:12 <br />SLOPE <br />13:12 <br />SLOPE <br />6:12 <br />SLOPE <br />13:12 <br />SLOPE <br />13:12 <br />SLOPE <br />6:12 <br />SLOPE <br />6:12 <br />SLOPE <br />6:12 <br />SLOPE <br />NO ROOF OVERHANG ON THIS SIDE <br />NO <br /> <br />R <br />O <br />O <br />F <br /> <br />O <br />V <br />E <br />R <br />H <br />A <br />N <br />G <br /> <br />O <br />N <br /> <br />T <br />H <br />I <br />S <br /> <br />S <br />I <br />D <br />E <br />NO ROOF OVERHANG ON THIS SIDE <br />ATTIC AREA: 360 SQ.FT. <br /> 360x(1150)= 2.40 SQ. FT. <br />VENTILATION NEEDED: 2.40 SQ.FT. <br /> <br />VENTILATION PROVIDED: <br />O'HAGIN ATTIC VENTILATION COBRA RIGID VENT 3 - 4'X9" <br />LOW PROFILE TAPERED 24"x 24" (INSTALLATION DETAILS ON SHEET N5) RECTANGULAR LOUVERS 14"X12" <br /> (1)x 0.50 = 0.00 SQ.FT. (3)x 0.50= 1.50 SQ.FT. (2)x 0.37= 0.74 SQ.FT. <br /> TOTAL VENTILATION PROVIDED: 2.74 SQ.FT. <br />(N) COBRA RIGID VENT 3 - 4'X9" <br />(N) RECTANGULAR LOUVERS 14"X12" <br />(N) O'HAGIN VENT LOW PROFILE <br />TAPERED 24"X24" <br /> 1.) INSTALL VENTS SO AS TO PROVIDE PROPER CROSS VENTILATION. <br /> 2.)VENTS SHALL BE COVERED WITH CORROSION-RESISTANT METAL <br />MESH WITH MESH OPENINGS OF 1 4 ". 3.) 50% OF OPENINGS TO BE LOCATED 3' ABOVE OTHER ATTIC <br />VENTILATIONS OPENINGS. <br /> 4.) A MINIMUM OF 1" AIR SPACE SHALL BE PROVIDED BETWEEN THE <br />INSULATION AND THE ROOF SHEATHING AT THE VENT LOCATION PER <br />CRC R806.3 <br />UNDER FTG. AREA: 1,690 SQ.FT. <br /> 1,690 X (1150)= 11.27 SQ. FT. <br /> VENTILATION NEEDED: 11.27 SQ.FT. <br /> VENTILATION PROVIDED: <br /> UNDER FTG. VENT - 14"X6" RECTANGULAR ACCESS 24"X18" <br /> (14)x 0.49= 6.86 SQ.FT) (3)x 1.52= 4.56 SQ. FT. <br /> TOTAL VENTILATION PROVIDED: 11.42 SQ.FT. <br />A2.3 <br />EXISTING & PROPOSED <br />MAIN DWELLING ROOF <br />PLAN <br />NO. <br />1/4" = 1' - 0" <br />REVISION DATE <br />JOB NO <br />02/03/2026 <br />I. BUENO <br />28362 VINCENT MORAGA DR. STE A1 <br />TEMECULA, CA 92590 <br />626.807.4712 <br />RESTRICTIVE NOTICE:ALL DESIGN, IDEAS, DETAILS, PLANS ANDSPECIFICATIONS INDICATED BY THE DRAWINGS ARE <br />THE EXCLUSIVE PROPERTY OF FS DESIGN GROUP, THEPLANS WERE CREATED AND DEVELOPED FOR USE ONAND IN CONJUNCTION WITH THE SPECIFIC PROJECTDESCRIBED HEREIN. NOT PART THEREOF SHALL BEREPRODUCED, COPIED, ADAPTED, MODIFIED ORDISTRIBUTE TO OTHERS WITHOUT PRIOR WRITTENAND SPECIFIC CONSENT OF FS DESIGN GROUP <br />14-24 <br />MA <br />R <br />I <br />N <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />12 <br />1 <br />3 <br /> <br />& <br /> <br />1 <br />2 <br />1 <br />5 <br /> <br />S <br /> <br />B <br />I <br />R <br />C <br />H <br /> <br />S <br />T <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />. <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />SC <br />O <br />P <br />E <br /> <br />O <br />F <br /> <br />W <br />O <br />R <br />K <br />: <br />NE <br />W <br /> <br />3 <br />6 <br />0 <br /> <br />S <br />Q <br />. <br /> <br />F <br />T <br />. <br /> <br />A <br />D <br />D <br />I <br />T <br />I <br />O <br />N <br /> <br />T <br />O <br /> <br />M <br />A <br />I <br />N <br /> <br />D <br />W <br />E <br />L <br />L <br />I <br />N <br />G <br /> <br />& <br /> <br />N <br />E <br />W <br />84 <br />8 <br /> <br />S <br />Q <br />. <br /> <br />F <br />T <br />. <br /> <br />D <br />E <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br />FERNANDO SOLIS - DESIGNER <br />PROPOSED MAIN DWELLING ROOF PLAN SCALE: 1/4" = 1' - 0" <br />DATE <br />SCALE <br />DRAWN BY <br />NORTH <br />EXISTING MAIN DWELLING ROOF PLAN SCALE: 1/4" = 1' - 0"NORTH <br />SYMBOL LEGEND VENT CALCULATIONS <br />CRAWL SPACE VENT CALCULATIONS VENT NOTES