My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1213 & 1215 S Birch St - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Birch St
>
1213 S Birch St
>
1213 & 1215 S Birch St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/6/2026 5:00:33 AM
Creation date
5/6/2026 5:00:06 AM
Metadata
Fields
Template:
Plan
Permit Number
101124815
101124816
101126547
Full Address
1213 S Birch St
1215 S Birch St
Street Number
1215
Street Direction
S
Street Name
Birch
Street Suffix
St
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
328
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
4' <br />- <br />0 <br />" <br />4' <br />- <br />0 <br />" <br />3' <br />- <br />9 <br />" <br />1' <br />- <br />7 <br />" <br />4' <br />- <br />9 <br />" <br />4' <br />- <br />0 <br />" <br />5' <br />- <br />0 <br />" <br />11 <br />' <br />- <br />9 <br />" <br />13 <br />' <br />- <br />9 <br />" <br />33 <br />' <br />- <br />1 <br />0 <br />" <br />3 <br />C <br />C <br />2' <br />- <br />5 <br />" <br />1 <br />3' <br />- <br />0 <br />" <br />6' <br />- <br />0 <br />" <br />15'-4"12'-9" <br />28'-0" <br />A <br />3 <br />3 <br />2 <br />1' <br />- <br />6 <br />" <br />A <br />4 <br />6'-3"3'-3"6'-0"3'-6"8"3'-5" <br />12'-9"6'-3" <br />2' <br />- <br />5 <br />" <br />7'-1" <br />26'-0" <br />2'-0" <br />2'-0" <br />2'-0" <br />28'-0" <br />3' <br />- <br />5 <br />" <br />2' <br />- <br />0 <br />" <br />3' <br />- <br />3 <br />" <br />2' <br />- <br />1 <br />0 <br />" <br />5' <br />- <br />0 <br />" <br />2' <br />- <br />1 <br />0 <br />" <br />1' <br />- <br />2 <br />" <br />3' <br />- <br />0 <br />" <br />1' <br />- <br />9 <br />" <br />5' <br />- <br />0 <br />" <br />3' <br />- <br />7 <br />" <br />8' <br />- <br />8 <br />" <br />10 <br />' <br />- <br />8 <br />" <br />14 <br />' <br />- <br />6 <br />" <br />33 <br />' <br />- <br />1 <br />0 <br />" <br />(N) BEDROOM <br />(N) BEDROOM <br />TV <br /> W/D FRIDGE <br />(N) KITCHEN <br />(N) LIVING ROOM <br />D <br />E <br />6'-11"4'-0"4'-5"12'-9" <br />28'-0" <br />B <br />3'-0" <br />1 <br />DOWN <br />DOWN <br />DOWN <br />(P) WINDOW SCHEDULE <br />SYM. <br />5'-0" x 4'-0" <br />SIZE FUNCTION NOTES <br />SIZE <br />6'-0" x 6'-8" <br />FUNCTION <br />ENTRY <br />ENTRY <br />NOTESGLAZINGTYPEMATERIAL <br />MATERIAL <br />VINYL <br />GLAZING <br />4'-0" x 4'-0"SLIDER VINYL (LOW E) DUAL <br />(LOW E) DUAL <br />3'-0" x 6'-8" <br />SLIDER <br />3'-0" x 6'-8"SOLID <br />4'-0" x 4'-0"VINYL (LOW E) DUALSLIDER <br />PASSAGE <br />(P) DOOR SCHEDULE <br />HOLLOW CORE <br />SLIDING <br />WOOD <br />VINYL <br />B <br />C <br />A <br />WOOD <br />2'-8" x 6'-8"PASSAGEHOLLOW CORE WOOD <br />SYM. <br />1 <br />2 <br />3 <br />4 <br />4'-0" x 3'-0" <br />D <br />SLIDER VINYL (LOW E) DUALE <br />2'-0" x 3'-0"VINYL (LOW E) DUALSINGLE HUNG <br />13:12 <br />SLOPE <br />13:12 <br />SLOPE <br />10:12 <br />SLOPE <br />10:12 <br />SLOPE <br />10:12 <br />SLOPE <br />13:12 <br />SLOPE 10:12 <br />SLOPE <br />13:12 <br />SLOPE <br />10:12 <br />SLOPE <br />NO ROOF OVERHANG ON THIS SIDE <br />NO <br /> <br />R <br />O <br />O <br />F <br /> <br />O <br />V <br />E <br />R <br />H <br />A <br />N <br />G <br /> <br />O <br />N <br /> <br />T <br />H <br />I <br />S <br /> <br />S <br />I <br />D <br />E <br />NO ROOF OVERHANG ON THIS SIDE <br />NO <br /> <br />R <br />O <br />O <br />F <br /> <br />O <br />V <br />E <br />R <br />H <br />A <br />N <br />G <br /> <br />O <br />N <br /> <br />T <br />H <br />I <br />S <br /> <br />S <br />I <br />D <br />E <br />NO <br /> <br />R <br />O <br />O <br />F <br /> <br />O <br />V <br />E <br />R <br />H <br />A <br />N <br />G <br /> <br />O <br />N <br /> <br />T <br />H <br />I <br />S <br /> <br />S <br />I <br />D <br />E <br />NO <br /> <br />R <br />O <br />O <br />F <br /> <br />O <br />V <br />E <br />R <br />H <br />A <br />N <br />G <br />ON <br /> <br />T <br />H <br />I <br />S <br /> <br />S <br />I <br />D <br />E <br />NO <br /> <br />R <br />O <br />O <br />F <br /> <br />O <br />V <br />E <br />R <br />H <br />A <br />N <br />G <br />ON <br /> <br />T <br />H <br />I <br />S <br /> <br />S <br />I <br />D <br />E <br />ATTIC AREA: 848 SQ.FT. <br /> 848x(1150)= 5.65 SQ. FT. <br />VENTILATION NEEDED: 5.65 SQ.FT. <br /> <br />VENTILATION PROVIDED: <br />O'HAGIN ATTIC VENTILATION COBRA RIGID VENT 3 - 4'X9" <br /> LOW PROFILE TAPERED 24"x 24" (INSTALLATION DETAILS ON SHEET N5) RECTANGULAR LOUVERS14"X12" <br /> (3)x 0.50 = 1.50 SQ.FT. (5)x 0.50= 2.50 SQ. FT (5)x 0.37= 1.85 SQ.FT. <br /> TOTAL VENTILATION PROVIDED: 5.85 SQ.FT. <br />(N) O'HAGIN VENT LOW PROFILE <br />TAPERED 24"X24" <br />(N) COBRA RIGID VENT 3 - 4'X9" <br />(N) RECTANGULAR LOUVERS 14"X12" <br /> 1.) INSTALL VENTS SO AS TO PROVIDE PROPER CROSS VENTILATION. <br /> 2.)VENTS SHALL BE COVERED WITH CORROSION-RESISTANT METAL <br />MESH WITH MESH OPENINGS OF 1 4 ". 3.) 50% OF OPENINGS TO BE LOCATED 3' ABOVE OTHER ATTIC VENTILATIONS <br />OPENINGS. <br /> 4.) A MINIMUM OF 1" AIR SPACE SHALL BE PROVIDED BETWEEN THE INSULATION <br />AND THE ROOF SHEATHING AT THE VENT LOCATION PER CRC R806.3 <br />UNDER FTG. AREA: 848 SQ.FT. <br /> 848 X (1150)= 5.65 SQ. FT. <br /> VENTILATION NEEDED: 5.65 SQ.FT. <br /> VENTILATION PROVIDED: <br /> UNDER FTG. VENT - 14"X6" RECTANGULAR ACCESS 24"X18" <br /> (6)x 0.49= 2.94 SQ.FT) (2)x 1.52= 3.04 SQ. FT. <br /> TOTAL VENTILATION PROVIDED: 5.98 SQ.FT.32 <br />" <br />39 <br />- <br />1 <br />/ <br />4 <br />" <br />54" MIN <br />(SUGGESTED) <br />36" MIN <br />(SUGGESTED) <br />SIDE WALL BACK WALL <br />15 <br />" <br />MI <br />N <br />48 <br />" <br /> <br />M <br />A <br />X <br />TO <br /> <br />T <br />O <br />P <br /> <br />O <br />F <br /> <br />O <br />U <br />T <br />L <br />E <br />T <br />48 <br />" <br /> <br />M <br />A <br />X <br />HEIGHTS ARE TO <br />FINISH FLOOR <br />INTERIOR: DOORBELL HEIGHT <br />IS FROM FLOOR OR LANDING <br />EXTERIOR: <br />TO TOP OF DOORBELL <br />ASSEMBLY <br />W. <br />C <br />. <br />SHOWER <br />LA <br />V <br />. <br />OF 2X8 REINFORCEMENT <br />FOR FUTURE GRAB BARS <br />EXAMPLE LOCATION <br />W. <br />C <br />. <br />WATER CLOSET ADJACENT TO ONE SIDE WALL <br />AND A BACK WALL. <br />39 <br />- <br />1 <br />/ <br />4 <br />" <br />32 <br />" <br />OF 2X8 REINFORCEMENT <br />FOR FUTURE GRAB BARS <br />EXAMPLE LOCATION <br />WATER CLOSET ADJACENT <br />TO TWO SIDE WALLS <br />HEIGHTS FOR ELECTRICAL RECEPTACLE OUTLETS, <br />SWITCHES, DOORBELL BUTTONS, INCLUDING HVAC CONTROLS <br />SEE EXCEPTION 4 <br />SEE NOTE #6 <br />NOTES: <br />1. REINFORCEMENT MUST BE LOCATED BETWEEN THE DIMENSIONS SPECIFIED. <br />2. REINFORCEMENT MUST BE CONTINUOUS IN BATHTUB, BATHTUB COMBO & SHOWER WALL <br />ENCLOSURES, WHERE WALL FRAMING IS PROVIDED. <br />3. REINFORCEMENT MAY BE SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS THAT <br />PROVIDE EQUAL HEIGHT AND LOAD CAPACITY. <br />4. THE LOCATION OF THE REINFORCEMENT MUST BE INCORPORATED IN THE OPERATION AND <br />MAINTENANCE MANUAL (E.G. FLOOR PLAN AND ELEVATION DETAILS) REQUIRED BY CAL GREEN <br />SECTION 4.410.1 <br />5. ADDITIONAL BACK WALL REINFORCEMENT MUST BE INSTALLED WITH THE BOTTOM EDGE NO <br />MORE THAN 6-INCHES ABOVE THE BATHTUB RIM. <br />6. THE SUGGESTED DIMENSIONS ARE TO ACCOMMODATE THE MINIMUM REQUIRED 36-INCHES <br />CLEARANCE, CENTER TO CENTER, AT A WATER CLOSET; AND MINIMUM 24-INCHES CLEAR <br />SPACE IN FRONT OF WATER CLOSET (CPC 402.5). AT THIS TIME CRC R327 DOES NOT SPECIFY <br />THE MINUM LENGHTS AT THE THESE LOCATIONS. HOWEVER, PLEASE CONSULT WITH THE <br />LOCAL JURISDICTION. <br />EXCEPTIONS: <br />1. REINFORCEMENT FOR FUTURE FLOOR-MOUNTED, FOLDAWAY OR SIMILAR ALTERNATE <br />GRABBAR MAY BE INSTALLED WITH PRIOR APPROVALS FROM THE ENFORCING AGENCY. <br />2. WALL REINFORCEMENT IS NOT REQUIRED WHERE PRE-FABRICATED SHOWER & BATHTUB <br />PANELS THAT HAVE INTEGRAL FACTORY-INSTALLED GRAB BARS, OR WHEN <br />FACTORY-INSTALLED REINFORCEMENT FOR GRAB BARS IS PROVIDED. <br />3. REINFORCEMENT OF FLOOR IS NOT REQUIRED FOR BATHTUBS AND WATER CLOSETS <br />INSTALLED ON CONCRETE FLOORS. <br />4. DEDICATED RECEPTACLE OUTLETS; FLOOR RECEPTACLE OUTLETS; CONTROL MOUNTED ON <br />CEILING FANS AND CEILING LIGHTS AND CONTROLS LOCATED ON APPLIANCES; AND REQUIRED <br />RECEPTACLES ON A WALL SPACE THAT HAS A BUILT-IN FEATURE ABOVE FINISH FLOOR LESS <br />THAN 15-INCHES. <br />KITCHEN <br />WASHERS AND DRYERS SHALL BE INSTALLED AT LEAST 18 IN. ABOVE THE <br />FLOOR UNLESS A FLAMMABLE VAPOR IGNITION RESISTANT IS STALLED, PER <br />MC 305.1 <br />1. CONDENSERS SHALL BE INSTALLED, PER MFG. REQUIREMENTS AND CMC <br />903.2.4 <br />1. FURNACE INSTALLATION MUST BE PER MFG. INSTALLATION INSTRUCTIONS, <br />PER CMC 904.3. <br />1. ALL LIGHTING SHALL BE HIGH EFFICACY. <br />2. ALL OUTDOOR LIGHTING SHALL BE CONTROLLED BY A MANUAL ON AND OFF SWITCH <br />THAT DOES NOT OVERRIDE TO ON AND ON OF THE FOLLOWING: CONTROLLED BY A <br />PHOTOCELL AND MOTION SENSOR, PHOTO CONTROL AND AUTOMATIC SWITCH <br />CONTROL, ASTRONOMICAL TIME CLOCK, OR ENERGY MANAGEMENT CONTROL SYSTEM. <br />3. PROVIDE TAMPER RESISTANT RECEPTACLES FOR ALL NEW RECEPTACLES, PER CEC 406.12 (A) <br />1. PROVIDE EXHAUST HOOD ABOVE THE RANGE TOP A MINIMUM OF 30" ABOVE THE <br />COOKING SURFACES. <br />1. BATHTUB AND SHOWER FLOORS, WALLS ABOVE BATHTUBS WITH A <br />SHOWERHEAD, AND SHOWER COMPARTMENTS SHALL BE FINISHED WITH A <br />NONABSORBENT SURFACE EXTENDING TO A HEIGHT OF NOT LESS THAN 6 <br />FEET ABOVE THE FLOOR, PER R307.2 <br />2. WATER CLOSET SHALL HAVE 15 INCHES TO ANY WALL OR OBSTRUCTION ON <br />EACH SIDE OF ITS CENTERLINE AND 24INCH CLEAR SPACE IN FRONT, PER CPC <br />402.5. <br />3. A CERAMIC WALL TITLE FINISH SHALL BE INSTALLED IN TUB AND SHOWER <br />AREA AS WELL AS WALL PANELS IN SHOWER AREAS PER CRC R702.4.2. <br />GREEN BOARD SHALL NOT BE USED. <br />BATHROOM <br />PLUMBING <br />1. WATER PIPING MATERIALS WITHIN A BUILDING SHALL BE IN <br />ACCORDANCE WITH SEC. 604.1 OF THE CALIFORNIA PLUMBING <br />CODE. PEX, CPVC AND OTHER PLASTIC WATER PIPING SYSTEMS <br />SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS <br />OF SEC. 604 OF THE CPC, INSTALLATION STANDARDS OF APPENDIX <br />I OF THE CPC AND MANUFACTURERS RECOMMENDATION <br />STANDARDS. CPVC WATER PIPING REQUIRES A CERTIFICATION OF <br />COMPLIANCE AS SPECIFIED IN SEC 604.1.(D) OF THE CPC PRIOR TO <br />PERMIT ISSUANCE. <br />2. ALL HOSE BIBS MUST HAVE AN APPROVED ANI-SIPHON DEVICE. <br />(CPC 603.5.7)ELECTRICAL <br />CONDENSER <br />FURNACE <br />1. NEW DOORS SHALL BE "COLONIST" 6 PANEL REFINISHED AND PREHUNG UNLESS <br />DIRECTED OTHERWISE BY THE OWNER. <br />2. GLASS IN INGRESS AND EGRESS DOORS SHALL BE TEMPERED. <br />3. ALL EXTERIOR DOORS SHALL BE FULLY WEATHER STRIPPED <br />4. PROVIDE SINGLE CYLINDER DEADBOLT ON EXTERIOR DOORS. <br />5. INTERIOR DOORS SHALL HAVE ONE PAIR 3 1/2" STANLEY HINGES WITH BRASS FINISH. <br />VERIFY W/ OWNER. <br />6. EXTERIOR DOORS SHALL HAVE 1 1/2 PAIR 4" STANLEY RD-741 HINGES WITH BRASS <br />FINISH. VERIFY W/ OWNER. <br />7. INTERIOR DOOR LATCHES SETS AND TRIM SHALL BE SELECTED BY OWNER. <br />8. ALL HARDWARE SHALL BE INSTALLED COMPLETE WITH ALL ACCESSORIES I.E. SCREWS, <br />STRIKES ETC. AND DOORS SET TRUE AND SQUARE TO ITS JAMB. <br />9. ATTIC ACCESS DOOR SHALL HAVE PERMANENTLY ATTACHED INSULATION USING <br />ADHESIVE OR MECHANICAL FASTENERS AND SHALL BE GASKETED TO PREVENT AIR <br />LEAKAGE, PER CEC 150.0(a) 2 <br />10. PROVIDE FIRE SEPARATION BETWEEN THE GARAGE AND THE RESIDENCE, PER CRC <br />R302.5.1 FOR DOOR INTO HOUSE. PROVIDE SELF-CLOSING, SELF LATCHING DOOR. <br />WATER CLOSETS <br />SHOWERHEADS <br />WATER EFFICIENCY AND CONSERVATION <br />LAVATORY FAUCETS <br />KITCHEN FAUCETS <br />1.28 GPF <br />1.8 GPM @ 80 PSI <br />1.2 GPM @ 60 PSI * <br />1.8 GPM @ 60 PSI <br />METERING FAUCETS 0.20 GALLONS PER CYCLE <br />FIXTURE TYPE MAXIMUM FLOW RATE <br />* LAVATORY FAUCETS SHALL NOT HAVE A FLOW RATE LESS <br />THAN 0.8 GPM AT 20 PSI <br />A2.4 <br />PROPOSED 848 SQ. FT. <br />DETACHED ADU FLOOR <br />PLAN & ROOF PLAN <br />NO. <br />1/4" = 1' - 0" <br />REVISION DATE <br />DATE <br />SCALE <br />DRAWN BY <br />JOB NO <br />02/03/2026 <br />I. BUENO <br />28362 VINCENT MORAGA DR. STE A1 <br />TEMECULA, CA 92590 <br />626.807.4712 <br />RESTRICTIVE NOTICE:ALL DESIGN, IDEAS, DETAILS, PLANS ANDSPECIFICATIONS INDICATED BY THE DRAWINGS ARE <br />THE EXCLUSIVE PROPERTY OF FS DESIGN GROUP, THEPLANS WERE CREATED AND DEVELOPED FOR USE ONAND IN CONJUNCTION WITH THE SPECIFIC PROJECTDESCRIBED HEREIN. NOT PART THEREOF SHALL BEREPRODUCED, COPIED, ADAPTED, MODIFIED ORDISTRIBUTE TO OTHERS WITHOUT PRIOR WRITTENAND SPECIFIC CONSENT OF FS DESIGN GROUP <br />14-24 <br />MA <br />R <br />I <br />N <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />12 <br />1 <br />3 <br /> <br />& <br /> <br />1 <br />2 <br />1 <br />5 <br /> <br />S <br /> <br />B <br />I <br />R <br />C <br />H <br /> <br />S <br />T <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />. <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />SC <br />O <br />P <br />E <br /> <br />O <br />F <br /> <br />W <br />O <br />R <br />K <br />: <br />NE <br />W <br /> <br />3 <br />6 <br />0 <br /> <br />S <br />Q <br />. <br /> <br />F <br />T <br />. <br /> <br />A <br />D <br />D <br />I <br />T <br />I <br />O <br />N <br /> <br />T <br />O <br /> <br />M <br />A <br />I <br />N <br /> <br />D <br />W <br />E <br />L <br />L <br />I <br />N <br />G <br /> <br />& <br /> <br />N <br />E <br />W <br />84 <br />8 <br /> <br />S <br />Q <br />. <br /> <br />F <br />T <br />. <br /> <br />D <br />E <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br />FERNANDO SOLIS - DESIGNER <br />PROPOSED DETACHED ADU FLOOR PLAN SCALE: 1/4" = 1' - 0" <br />NOTES <br />EXISTING WALL <br />NEW FRAME WALLS W/ STUDS @ 16" O.C. 5/8" DRYWALL @ <br />INTERIOR & 7/8" STUCCO @ EXTERIOR <br />TO BE DEMO <br />SYMBOL LEGEND <br />DOOR NOTES <br />WASHER/DRYER <br />NORTHNORTHPROPOSED DETACHED ADU ROOF PLAN SCALE: 1/4" = 1' - 0" <br />SYMBOL LEGEND VENT CALCULATIONS <br />CRAWL SPACE VENT CALCULATIONS <br />01 <br />A2.1 <br />GRAB BAR REINFORCEMENT <br />1. GRAB BAR REINFORCEMENT FOR THE BATHROOM IDENTIFIED ON THE FLOOR PLANS FOR <br />2. “AGING-IN-PLACE AND FALL PREVENTION” COMPLIANCE SHALL BE INSTALLED AT THE WATER <br />3. CLOSET, SHOWER, BATHTUB AND BATHTUB/SHOWER AS STATED BELOW. <br />4. WATER CLOSET REINFORCEMENT: <br />a. REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE FIXTURE, OR ONE SIDE WALL AND THE BACK WALL. <br />b. FOR WATER CLOSET NOT PLACED ADJACENT TO A SIDE WALL CAPABLE OF ACCOMMODATING A GRAB BAR, REINFORCEMENT <br />SHALL BE INSTALLED FOR FLOOR-MOUNTED, FOLDAWAY OR SIMILAR ALTERNATE GRAB BARS ADJACENT TO THE WATER CLOSET APPROVED <br />BY THE ENFORCING AGENCY. <br />c. REINFORCEMENT OF FLOORS SHALL NOT BE REQUIRED FOR WATER CLOSETS INSTALLED ON CONCRETE SLAB FLOORS. <br />3. SHOWER REINFORCEMENT: <br />a. REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED. <br />b. FOR SHOWER ENCLOSURES THAT DO NOT PERMIT INSTALLATION OF REINFORCEMENT AND/OR GRAB BARS, REINFORCEMENT <br />SHALL BE INSTALLED FOR FLOOR-MOUNTED GRAB BARS OR AN ALTERNATE METHOD IS APPROVED BY THE ENFORCING AGENCY. <br />c. WHERE FACTORY-INSTALLED GRAB BARS OR FACTORY-INSTALLED REINFORCEMENT IS PROVIDED IN PRE-FABRICATED SHOWER <br />ENCLOSURES AND BATHTUB WALL PANELS, REINFORCEMENT SHALL NOT BE REQUIRED IN WALL FRAMING. <br />4. BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT: <br />a. REINFORCEMENT SHALL BE CONTINUOUS ON EACH END OF THE BATHTUB AND THE BACK WALL. <br />b. ADDITIONALLY, BACK WALL REINFORCEMENT FOR A LOWER GRAB BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE OF THE <br />REINFORCEMENT LOCATED NO MORE THAN 6 INCHES ABOVE THE BATHTUB RIM. <br />c. FOR BATHTUBS WITH NO SURROUNDING WALLS, OR WHERE WALL PANELS DO NOT PERMIT THE INSTALLATION OF REINFORCEMENT. <br />d. REINFORCEMENT SHALL BE INSTALLED FOR FLOOR-MOUNTED GRAB BARS ADJACENT TO THE BATHTUB OR AN ALTERNATE METHOD IS <br />APPROVED BY THE ENFORCING AGENCY. <br />e. REINFORCEMENT OF FLOORS SHALL NOT BE REQUIRED FOR BATHTUBS INSTALLED ON CONCRETE SLAB FLOORS. <br />AGING-IN-PLACE DESIGN AND FALL PREVENTION NOTES <br />VENT NOTES <br />01 <br />A2.1
The URL can be used to link to this page
Your browser does not support the video tag.