Laserfiche WebLink
LICENSED A RCHITECT <br />STATEOF CALIFORNIA <br />No. C 31423 <br />TH <br />I <br />S <br /> <br />D <br />R <br />A <br />W <br />I <br />N <br />G <br /> <br />I <br />S <br /> <br />M <br />E <br />A <br />N <br />T <br /> <br />T <br />O <br /> <br />B <br />E <br /> <br />P <br />R <br />I <br />N <br />T <br />E <br />D <br /> <br />3 <br />0 <br />" <br />X <br />4 <br />2 <br />" <br />. <br /> <br /> <br />A <br />T <br /> <br />A <br />N <br />Y <br /> <br />O <br />T <br />H <br />E <br />R <br /> <br />S <br />I <br />Z <br />E <br />, <br /> <br />D <br />I <br />S <br />R <br />E <br />G <br />A <br />R <br />D <br /> <br />R <br />E <br />F <br />E <br />R <br />E <br />N <br />C <br />E <br />S <br /> <br />T <br />O <br /> <br />S <br />C <br />A <br />L <br />E <br />. <br />© ASPEN STREET 2026 <br />KEY PLAN <br />N <br />B C D E F G H I J <br />8 <br />K L <br />10 <br />IS <br />S <br />U <br />E <br />D <br />SCALE: <br />JOB: <br />SHEET NO. <br />AGENCY NO. <br />AGENCY APPROVALS <br />ON <br />FO <br />R <br />DRAWING TITLE <br />DR. BY: <br />215021.51 <br />AS SHOWN <br />Modesto, CA 95351 <br />w w w . n e x u s e n g i n e e r i n g . n e t <br />Tel: 209.572.7399 Fax: 209.236.1579 <br />1400 Lone Palm Ave, Suite A <br />Consulting Mechanical Engineers <br />HVAC . Plumbing/Piping . Fire Sprinklers <br />Process/Plant Engineering . Refrigeration <br />PH <br />O <br />E <br />N <br />I <br />X <br /> <br />H <br />O <br />U <br />S <br />E <br />OR <br />A <br />N <br />G <br />E <br /> <br />C <br />O <br />U <br />N <br />T <br />Y <br />IN <br />T <br />E <br />R <br />I <br />O <br />R <br /> <br />A <br />N <br />D <br /> <br />E <br />X <br />T <br />E <br />R <br />I <br />O <br />R <br />TE <br />N <br />A <br />N <br />T <br /> <br />I <br />M <br />P <br />R <br />O <br />V <br />E <br />M <br />E <br />N <br />T <br />S <br />BU <br />I <br />L <br />D <br />I <br />N <br />G <br />S <br /> <br />C <br /> <br />& <br /> <br />D <br />12 <br />0 <br />7 <br /> <br />E <br /> <br />F <br />R <br />U <br />I <br />T <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />CITY RESUBMITTAL 01 <br />2/6/2026 <br />MECHANICAL <br />DETAILS <br />12" <br />PROVIDE 3/8"ø x 2" LONG <br />LAG BOLT & WASHER. <br />ONE AT EACH CORNER OF <br />ATTACH TO (E) ROOF <br />WITH 3/8"DIA HILTI KB-TZ2, <br />2-1/2" MIN. EMBEDMENT, <br />MIN. (2) EXPANSION ANCHOR <br />THY TEMS-3 (18 GA) <br />MOUNTING SUPPORT <br />NOTE: UNIT SHALL BE INSTALLED LEVEL. PROVIDE <br />SLEEPERS AS NECESSARY TO MATCH ROOF PITCH. <br />(E) CONCRETE SLAB <br />23-5/8" <br />251 LBS UNIT AT INSTALLATION FEET <br />16 13/32" <br />52-11/16" <br />8-27/32" <br />PROVIDE CANT STRIPS <br />AND FLASHING. REROOF <br />FOR WATER TIGHT FIT <br />CURB (2 PLACES) <br />8-27/32" <br />23-5/8" <br />8-27/32"8-27/32" <br />LAG BOLT <br />CONDENSER <br />CURB <br />13" <br />SIDE VIEW <br />TOP VIEW <br />REFRIGERANT CONNECTIONS <br />SCALE: <br /> CONDENSING UNIT MOUNTING DETAIL <br />M300 N/A <br />1 <br />BOLTS AT EA. END OF CURB, (4) <br />A.B. AT EACH CURB, MIN. (8) <br />EXPANSION ANCHOR BOLTS <br />FOR EQUIPMENT ANCHORAGE. <br />DUCT PERIMETER <br />P/2 = 30" <br />SPECIAL ANALYSIS REQUIRED <br />- <br />STRAP <br />1"x0.030" (22 GA) <br />1"x0.058" (16 GA) <br />1-1/2"x0.058" (16 GA) <br />1"x0.047" (18 GA) <br />MAXIMUM HALF OF PAIR @ 10'-0" SPACING <br />P/2 = 72" <br />P/2 = 96" <br />P/2 = 120" <br />P/2 = 168" <br />P/2 = 192" <br />P/2 > 193" <br />WIRE/ROD <br />10 GA <br />3/8" <br />1/2" <br />10 GA1"x0.030" (22 GA) <br />1-1/2"x0.058" (16 GA) <br />1"x0.058" (16 GA) <br />1"x0.047" (18 GA) <br />1"x0.036" (20 GA) <br />1-1/2"x0.058" (16 GA) <br />1/4" <br />PAIR @ 8'-0" SPACING <br />STRAP WIRE/ROD <br />1"x0.058" (16 GA) <br />1"x0.058" (16 GA) <br />1"x0.047" (18 GA) <br />1"x0.036" (20 GA) <br />1"x0.030" (22 GA) <br />1"x0.030" (22 GA)12 GA <br />PAIR @ 5'-0" SPACING <br />STRAP WIRE/ROD <br />12 GA1"x0.030" (22 GA) <br />1"x0.058" (16 GA) <br />1"x0.047" (18 GA) <br />1"x0.036" (20 GA) <br />1"x0.030" (22 GA) <br />1"x0.030" (22 GA) <br />PAIR @ 4'-0" SPACING <br />STRAP WIRE/ROD <br />WHENSTRAPS ARE LAP-JOINED, USE THESE MINIMUM FASTENERS: <br />1"x0.047", 0.036" 0.030" - TWO NO. 10 OR ONE 1/4" BOLT <br />1"x0.058" - TWO 1/4" BOLT <br />1-1/2"x0.058" - TWO 3/8" BOLT <br />PLACE FASTENERS IN SERIES, NOT SIDE-BY-SIDE. <br />MAX LOAD SCHEDULE <br />STRAP WIRE OR ROD (DIA.) <br />1"x0.030" - 260 LBS <br />1"x0.036" - 320 LBS <br />1"x0.047" - 420 LBS <br />1"x0.058" - 700 LBS <br />1-1/2"x0.030" - 1100 LBS 3/8" - 680 LBS <br />1/4" - 270 LBS <br />0.162" - 160 LBS <br />0.135" - 120 LBS <br />0.106" - 80 LBS <br />1/2" - 1250 LBS <br />5/8" - 2000 LBS <br />3/4" - 3000 LBS <br />NOTES: <br />1. <br />2. <br />EXTERNAL LOADS. <br />TABLES ALLOW FOR DUCT WEIGHT 1 LB./SF INSULATION WEIGHT NORMAL REINFORCEMENT AND TRAPEZE WEIGHT BUT NO <br />DIMENSIONS OTHER THAN GAUGE ARE IN INCHES. <br />STRAPS ARE GALVANIZED STEEL; OTHER MATERIALS ARE UNCOATED STEEL.3. <br />ALLOWABLE LOADS FOR P/2 ASSUME THAT DUCTS ARE 0.058" (16 GA) MAXIMUM, EXCEPT THAT WHEN MAXIMUM DUCT DIMENSION (W) IS4. <br />OVER 60", THEN P/2 MAXIMUM IS 1.25W. <br />5. FOR TRAPEZE SIZES SEE TITLE 24, PART 4, 2001 CALIFORNIA MECHANICAL CODE, APPENDIX A, UMC STANDARD 6-2, TABLE <br />NUMBER 6-2-B. <br />6. 12 GA, 10 GA OR 8 GA WIRE IS STEEL OF BLACK-ANNEALED, BRIGHT BASIC OR GALVANIZED TYPE. <br />DUCT SUPPORT STRAP, <br />SEE TABLE BELOW FOR DETAILS <br />GALVANIZED SHEET METAL DUCT <br />WITH ACOUSTIC LINING, SHEET <br />METAL DUCT WITH EXTERNAL <br />INSULATION OR VENT, <br />SEE PLANS FOR SIZE <br />#10 x 3/4" SELF-TAPPING S.M. SCREWS <br />TO ANCHOR STRAPS TO DUCT. ALL <br />STRAPS TO BE TIGHT AGAINST DUCT. <br />ACOUSTICAL LINING OR INTERNALLY LINED INSULATION. <br />SUPPLY & RETURN AIR DUCTS SERVING A HOSPITAL <br />OR OTHER MEDICAL BUILDING SHALL NOT HAVE <br />OR GREATER THAN 6 SQUARE FEET REQUIRE <br />HANGING DUCTS WITH A CROSS-SECTIONAL AREA EQUAL TO <br />DUCTWORK SHALL CONFORM WITH APPENDIX A, <br />NOTES: <br />3. <br />1. <br />2. <br />HANGER MUST BE POSITIVELY ATTACHED TO <br />THE DUCT WITHIN 2" OF THE TOP OF THE DUCT <br />4. <br />1-1/2"x0.058" (16 GA) <br />3/8" <br />1/2" <br />1/2" <br />3/8" <br />3/8" <br />1/2" <br />1/2" <br />1/4" <br />3/8" <br />3/8" <br />3/8" <br />3/8" <br />3/8" <br />3/8" <br />1/4" <br />1/4" <br />1/4" <br />STANDARD 6-2 OF THE CMC. <br />SEISMIC BRACING IN ACCORDANCE WITH MASON OPM 0043-13 <br />WITH A MINIMUM OF TWO #10 SHEET METAL SCREWS <br />SCALE: <br /> ROUND DUCT HANGER DETAIL <br />M300 NONE <br />4 <br />SCALE: <br /> RECTANGULAR DUCT HANGER DETAIL <br />M300 NONE <br />5 <br />LINED INSULATION. <br />81" TO 94" <br />51" TO 80" <br />37" TO 50" <br />25" TOI 36" <br />19" TO 24" <br />11" TO 18" <br />DUCT DIAMETER <br />12' <br />12' <br />12' <br />MAXIMUM SPACING <br />< 10" <br />12' <br />12' <br />12' <br />12'1" x 0.030" (22 GA.) <br />2 @ 1" x 0.058" (16 GA.) <br />2 @ 1" x 0.037" (18 GA.) <br />2 @ 1" x 0.036" (20 GA.) <br />1" x 0.036" (20 GA.) <br />1" x 0.030" (22 GA.) <br />1" x 0.030" (22 GA.) <br />2 @ 3/8" <br />2 @ 3/8" <br />2 @ 3/8" <br />ROD DIAMETER <br />1/4" <br />1/4" <br />3/8" <br />1/4" <br />STRAP <br />SUPPLY & RETURN AIR DUCTS SERVING A HOSPITAL OR OTHER <br />MEDICAL BUILDING SHALL NOT HAVE ACOUSTICAL LINING OR INTERNALLY <br />SQUARE FEET REQUIRE SEISMIC BRACING IN ACCORDANCE WITH MASON OPM 0043-13. <br />HANGING DUCTS WITH A CROSS-SECTIONAL AREA EQUAL TO OR GREATER THAN 6 <br />DUCTWORK SHALL CONFORM WITH APPENDIX A, STANDARD 6-2 OF THE CMC. <br />NOTES: <br />3. <br />1. <br />2. <br />DUCT SUPPORT STRAP, <br />SEE TABLE BELOW FOR DETAILS <br />GALVANIZED SHEET METAL DUCT <br />WITH ACOUSTIC LINING, SHEET <br />METAL DUCT WITH EXTERNAL <br />INSULATION OR VENT, <br />SEE PLANS FOR SIZE <br />#10 x 3/4" SELF-TAPPING S.M. SCREWS <br />TO ANCHOR STRAPS TO DUCT. ALL <br />STRAPS TO BE TIGHT AGAINST DUCT. <br />EACH OF THREE SIDES AS SHOWN. <br />SCALE: <br /> TYPICAL REGISTER DETAIL <br />M300 NONE <br />6 <br />T-BAR CEILING <br />FRAME TO MATCH CEILING TYPE <br />DAMPER (WHEN SPECIFIED) <br />OPERABLE FROM FACE <br />TRANSITION AS NEEDED <br />24 GA SHEET METAL TAB WITH <br />#12 SM SCREW (TYP. 4 PLACES) <br />DRAWBAND - ENTIRE FLEX DUCT ASSEMBLY. <br /> LEAVE NO EXPOSED INSULATION <br /> INSIDE OR OUT. <br />DRAWBAND - INNER LINER AND HELIX ONLY <br />MANUAL BALANCE DAMPER <br />FLEXIBLE FIBERGLASS <br />DUCT (5' MAX. LENGTH) <br />2"MIN 26 GA <br />HANGER SADDLE <br />INSULATED SHEET <br />METAL DUCT <br />HARD CEILING <br />FLEXIBLE DUCT NOTES: <br /> FIVE (5) FEET. <br /> RADIUS TURNS OR OFFSETS. THE MAXIMUM LENGTH SHALL BE <br />2. INSTALLATION OF FLEXIBLE DUCTS SHALL MINIMIZE SHARP <br /> WIRE HELIX AND IMPERVIOUS, SMOOTH, NON-PERFORATED INTERIOR <br /> VINYL LINER. <br /> (PER CEC STANDARDS), ENCAPSULATED SPRING STEEL <br /> LAMINATED VAPOR BARRIER, FIBER GLASS INSULATION <br />1. CONNECT TO EXISTING FLEXIBLE DUCT WHERE INDICATED. ANY <br />CONICAL OR 45° LEAD IN, <br />AVOID STRAIGHT TAP <br />DUCT MAIN <br />EXAMPLE <br />POSITIVELY ATTACH REGISTER <br />TO CEILING WITH CLIP OR SIMILAR <br /> NEW FLEXIBLE DUCTS SHALL CONSIST OF AN EXTERIOR REINFORCED <br />TO UPPER ATTACHMENT - SEE HVAC DUCT <br />CONSTRUCTION STANDARDS - METAL AND <br />FLEXIBLE, THIRD EDITION, SMACNA - 2006, <br />FIGURES 5-2, 5-3 AND 5-4. PROVIDE FRAMING, <br />BLOCKING OR STRUCTURAL MEMBER AS MAY <br />BE REQUIRED. <br />TO UPPER ATTACHMENT - SEE HVAC DUCT <br />CONSTRUCTION STANDARDS - METAL AND <br />FLEXIBLE, THIRD EDITION, SMACNA - 2006, <br />FIGURES 5-2, 5-3 AND 5-4. PROVIDE FRAMING, <br />BLOCKING OR STRUCTURAL MEMBER AS MAY <br />BE REQUIRED. <br />SCALE: <br />2 <br />M300 N/A <br /> AC UNIT MOUNTING DETAIL (AC-1) <br />24 GAGE GALV. SM <br />MOUNTING CHANNEL ON UNIT <br />COUNTER FLASHING <br />3/8"ø x 3" LONG LAG BOLT & <br />WASHER, MIN. 2 PER SIDE, <br />ROOFING UP UNDER FLASHING BY OTHERS <br />NEOPRENE SPONGE GASKET <br />797 LBS <br />1/2"ø HILTI KB-TZ2 EXPANSION ANCHORS @ MAX 2'-0" O.C. <br />PRESLOPED FACTORY CURB <br />HVAC UNIT TO BE LEVEL. <br />ASSEMBLY FOR HVAC UNIT. <br />24 GAGE GALV. SHEET METAL <br />FIBERGLASS INSULATING BOARD <br />WITH 2" OF 3-1/2lb DENSITY <br />LINE TOP OF ROOF INSIDE CURB <br />24" OC MAX. <br />WOOD NAILER <br />FULL CURB CAP, <br />RIGID INSULATION <br />2" WIDE x 1/4" THK. CONTINUOUS <br />AC-1 <br />SCALE: <br />3 <br />M300 N/A <br /> AC UNIT MOUNTING DETAIL (AC-2) <br />24 GAGE GALV. SM <br />MOUNTING CHANNEL ON UNIT <br />COUNTER FLASHING <br />3/8"ø x 3" LONG LAG BOLT & <br />WASHER, MIN. 2 PER SIDE, <br />EXTEND ROOFING UP <br />(N) ROOF <br />& UNDER COUNTER FLASHING <br />NEOPRENE SPONGE GASKET <br />359 LBS <br />3" MIN EMBED, MAX. 3" FROM EACH CURB EDGE. <br />1/2"ø LAG BOLTS @ 2'-0" O.C., <br />PRESLOPED FACTORY CURB <br />HVAC UNIT TO BE LEVEL. <br />ASSEMBLY FOR HVAC UNIT. <br />24 GAGE GALV. SHEET METAL <br />FIBERGLASS INSULATING BOARD <br />WITH 2" OF 3-1/2lb DENSITY <br />LINE TOP OF ROOF INSIDE CURB <br />FACTORY-SLOPED CURB SHALL BEAR DIRECTLY ON ROOF. <br />24" OC MAX. <br />WOOD NAILER <br />FULL CURB CAP, <br />RIGID INSULATION <br />2" WIDE x 1/4" THK. CONTINUOUS <br />SEE STRUCTURAL FOR BLOCKING <br />AC-2 <br />FACTORY-SLOPED CURB SHALL BEAR DIRECTLY ON ROOF. <br />CONTINUOUS FIBER CANT STRIP <br />BY ROOFER AS NECESSARY.CONTINUOUS FIBER CANT STRIP <br />BY ROOFER AS NECESSARY. <br />(E) CONCRETE SLAB <br />NEW ROOFING & INSULATION BY OTHERS