Ø
<br />TP
<br />S
<br />UNLESS NOTED OTHERWISE
<br />DIA
<br />TP
<br />U.N.O.
<br />DIAMETER
<br />TRAP PRIMER
<br />SV
<br />TH
<br />STR
<br />SOLENOID VALVE
<br />STRAINER
<br />THERMOMETER
<br />VENT PIPINGV
<br />OR
<br />CO
<br />FLEXIBLE CONNECTOR
<br />ECCENTRIC REDUCER
<br />GAS PRESSURE REGULATOR
<br />GAS COCK, PLUG COCK
<br />PRESSURE GAUGE
<br />PRESSURE REDUCING VALVE
<br />RELIEF VALVE OR TEMPERATURE & PRESSURE RELIEF VALVE
<br />GPR
<br />RV or T&P
<br />PRV
<br />PG
<br />PG
<br />HB
<br />GL. V.
<br />AN
<br />PIPE GUIDE
<br />PIPE ANCHOR
<br />GLOBE VALVE
<br />HOSE BIBB
<br />SOV
<br />GCK
<br />GSCK, PC
<br />FS
<br />FC
<br />FS
<br />FD
<br />ER
<br />GAGE COCK
<br />SHUT OFF VALVE
<br />FLOOR DRAIN
<br />FLOW SWITCH
<br />BUTTERFLY VALVE
<br />BRANCH - SIDE CONNECTION
<br />BRANCH - BOTTOM CONNECTION
<br />BRANCH - TOP CONNECTION
<br />GRADE CLEANOUT
<br />CATCH BASIN, ROOF DRAIN
<br />CALIBRATED BALANCE VALVE
<br />CAP ON END OF PIPE
<br />POINT OF CONNECTION
<br />CONCENTRIC REDUCER
<br />CIRCULATING PUMP
<br />CHECK VALVECKV
<br />WCO
<br />CP
<br />POC
<br />CR
<br />CO
<br />CO
<br />FCO
<br />GCO
<br />WALL CLEANOUT
<br />FLOOR CLEANOUT
<br />CLEANOUT PLUG
<br />CBV
<br />CB, RD
<br />COP
<br />BFV
<br />XXXXX
<br />OR
<br />CD
<br />D
<br />X X X EXISTING TO BE REMOVED
<br />CONDENSATE DRAIN
<br />DRAIN OR INDIRECT WASTE
<br />RAINWATER OVERFLOW LEADER (STORM)
<br />ACCESS DOOR, ACCESS PANEL
<br />STORM DRAIN, RAINWATER LEADER
<br />AUTOMATIC AIR VENT
<br />AQ
<br />AD
<br />AAV
<br />BV
<br />AC
<br />ANV
<br />AD, AP
<br />AQUASTAT
<br />BALL VALVE
<br />AREA DRAIN
<br />ANGLE VALVE
<br />AIR CHAMBER
<br />OFL
<br />SD, RWL
<br />IW
<br />CD
<br />D OR IW
<br />HOT WATER RETURN
<br />NATURAL GAS - LOW PRESSURE
<br />HOT WATER SUPPLY
<br />G
<br />HW (110°, 140°)
<br />HWR
<br />CW COLD WATER
<br />SYMBOL DESCRIPTION
<br />PLUMBING LEGEND
<br />SOIL, WASTE OR SANITARY SEWER BELOW FLOOR
<br />ABBREVIATION
<br />SS
<br />X
<br />OVERFLOW CONDENSATE DRAINOCD
<br /> PIPE: SERVICE WEIGHT CAST IRON SOIL PIPE PER ASTM A-74
<br /> A. DWV
<br />PLUMBING MATERIAL SPECIFICATIONS
<br /> C. CONDENSATE DRAIN
<br /> B. DOMESTIC WATER
<br /> FITTINGS: WROUGHT COPPER PER ANSI 16.22
<br /> PIPE: COPPER TYPE L PER ASTM B-88
<br /> PIPE: COPPER TYPE L PER ASTM B-88
<br /> FITTINGS: WROUGHT COPPER PER ANSI 16.22
<br /> FITTINGS: CAST IRON "NO-HUB" PER CISPI 310
<br /> INSULATION AND ALL-SERVICE-JACKET
<br /> INSULATION (3/4" DIA. PIPE AND SMALLER): INSULATE HW & HWR WITH 1" FIBERGLASS
<br />OCD
<br />SOIL, WASTE OR SANITARY SEWER OVERHEADSS
<br /> INSULATION AND ALL-SERVICE-JACKET
<br /> INSULATION (1" - 1-1/2" DIA. PIPE): INSULATE HW & HWR WITH 1-1/2" FIBERGLASS
<br />PLUMBING GENERAL NOTES
<br />1.SCOPE:
<br />MODIFICATIONS TO THE EXISTING PLUMBING SYSTEM AS GENERALLY DELINEATED ON THE
<br />PLUMBING DRAWINGS, INCLUDING SERVICE PIPING AND FINAL CONNECTIONS TO EQUIPMENT
<br />FURNISHED AND INSTALLED BY OTHER TRADES AS MAY BE SHOWN ON THE ARCHITECTURAL,
<br />ELECTRICAL OR OTHER DRAWINGS OF THE CONTRACT DOCUMENTS.
<br />2.CALIFORNIA CODE OF REGULATIONS:
<br />ALL HOT WATER DISTRIBUTION AND CIRCULATION LINES SHALL BE INSULATED IN ACCORDANCE
<br />WITH SECTION 120.3 OF THE CALIFORNIA CODE OF REGULATIONS, TITLE 24, PART 6,
<br />SUBCHAPTER 3.
<br />3.ALL PLUMBING FIXTURES & EQUIPMENT USED (E.G. SHOWERHEADS, LAVATORY FAUCETS, SINK
<br />FAUCET AND WATER HEATERS) SHALL HAVE BEEN CERTIFIED TO THE CALIFORNIA ENERGY
<br />COMMISSION BY ITS MANUFACTURER TO COMPLY WITH THE EFFICIENCY STANDARDS FOR SUCH
<br />APPLIANCES.
<br />4.CODES:
<br />ALL WORK, MATERIAL, AND EQUIPMENT SHALL BE FURNISHED AND INSTALLED IN COMPLIANCE
<br />WITH THE FOLLOWING CODES AS ADOPTED AND AMENDED BY THE INSPECTING AUTHORITY
<br />HAVING JURISDICTION. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT THE
<br />INSTALLATION OF WORK, MATERIAL OR EQUIPMENT NOT CONFORMING TO THESE OR OTHER
<br />CODES APPLICABLE TO THIS PROJECT.
<br />A.2022 CALIFORNIA ADMINISTRATIVE CODE (CAC) PART 1, TITLE 24, CALIFORNIA CODE OF
<br />REGULATIONS (CCR)
<br />B.2022 CALIFORNIA BUILDING CODE (CBC) PART 2, TITLE 24, CCR BASED ON THE 2021
<br />INTERNATIONAL BUILDING CODE (IBC)
<br />C.2022 CALIFORNIA ELECTRICAL CODE (CEC) PART 3, TITLE 24, CCR BASED ON THE 2020
<br />NATIONAL ELECTRICAL CODE (NEC)
<br />D.2022 CALIFORNIA MECHANICAL CODE (CMC) PART 4, TITLE 24, CCR BASED ON THE 2021
<br />UNIFORM MECHANICAL CODE (UMC)
<br />E.2022 CALIFORNIA PLUMBING CODE (CPC) PART 5, TITLE 24, CCR BASED ON THE 2021
<br />UNIFORM PLUMBING CODE (UPC)
<br />F.2022 CALIFORNIA ENERGY CODE (CEC) PART 6, TITLE 24 CCR.
<br />G.2022 CALIFORNIA FIRE CODE (CFC) PART 9, TITLE 24, CCR BASED ON THE 2021
<br />INTERNATIONAL FIRE CODE (IFC)
<br />H.2022 CALIFORNIA GREEN BUILDING STANDARDS (CGBSC) PART 11, TITLE 24, CCR
<br />5.WORKMANSHIP:
<br />ALL WORK SHALL BE DONE IN A NEAT AND WORKMANLIKE MANNER ACCORDING TO THE BEST
<br />TRADE PRACTICE BY THOSE SKILLED IN THE PARTICULAR TRADE. EQUIPMENT, FIXTURES,
<br />PIPING, ETC., SHALL BE PLUMB, LEVEL, SQUARE AND/OR CENTERED, ETC. EQUIPMENT TO BE
<br />INSTALLED IN STRICT COMPLIANCE WITH MANUFACTURER'S RECOMMENDATIONS.
<br />6.EXISTING INFORMATION:
<br />LOCATION, SIZE, ELEVATION, MATERIAL, ETC., OF EXISTING UTILITIES IS PROVIDED FROM
<br />SOURCES DEEMED RELIABLE BUT IS NOT GUARANTEED. THE CONTRACTOR SHALL FIELD VERIFY
<br />ALL DATA BEFORE PROCEEDING WITH ANY WORK. NO EXTRA COST WILL BE ALLOWED FOR
<br />SERVICES NOT AS SHOWN.
<br />7.PERMITS AND UTILITY SERVICE FEES:
<br />THE PLUMBING CONTRACTOR SHALL ARRANGE AND PAY FOR ALL PERMITS, INSPECTIONS, AND
<br />SERVICE CHARGES REQUIRED FOR THE INSTALLATION OF THE WORK.
<br />8.ACCURACY:
<br />PLANS ARE DIAGRAMMATIC. THE CONTRACTOR SHALL CONFIRM ALL DIMENSIONS AND
<br />LOCATION OF WALLS, PARTITIONS, FIXTURES, ETC., AGAINST DESIGN PLANS FOR CONSISTENCY
<br />AND ACCURACY PRIOR TO COMMENCING WORK.
<br />9.PROVIDE AND INSTALL CONDENSATE DRAIN WITH TRAP AT EACH A/C UNIT PER THE UPC, AT
<br />LOCATIONS SHOWN ON DRAWINGS. COORDINATE WITH MECHANICAL CONTRACTOR.
<br />10.PROVIDE AND INSTALL ACCESS PANELS FOR ALL SHUT-OFF, ISOLATION, OR BRANCH VALVES
<br />NOT READILY ACCESSIBLE. ACCESS PANELS SHALL BE PROVIDED AND INSTALLED AT ALL
<br />TRAP PRIMER VALVES AND WATER HAMMER ARRESTORS.
<br />11.ALL PIPING PASSING THROUGH CONCRETE FLOORS SHALL BE SLEEVED TO PROTECT PIPING
<br />AGAINST BREAKAGE.
<br />12.HORIZONTAL DRAINAGE PIPING LESS THAN 4" IN DIAMETER SHALL BE SLOPED AT A MINIMUM OF
<br />1/4" PER FOOT (2%) DRAINAGE PIPING 4" AND LARGER SHALL BE SLOPED AT A MINIMUM OF 1/4"
<br />PER FOOT (2%) UNLESS OTHERWISE APPROVED BY THE AHJ.
<br />13.ALL PLUMBING FIXTURES AND PIPING SHALL BE LISTED BY AN APPROVED LISTING AND TESTING
<br />AGENCY AND PROPERLY LABELED.
<br />14.ALL PIPES SHALL BE LABELED WITH CLASSIFICATION, COLOR SCHEME, AND SIZING PER ANSI
<br />STANDARD A13.1.
<br />15.DISINFECT NEW, REPAIRED, OR ALTERED POTABLE WATER SYSTEMS PER 2022 CPC 609.10.
<br />BACTERIOLOGICAL TESTING PROCEDURE SHALL BE BY A THIRD PARTY TESTING LABORATORY.
<br />DEMOLITION NOTES
<br />1.THE CONTRACTOR SHALL VISIT THE PROJECT SITE AND MAKE HIMSELF AWARE OF ALL EXISTING
<br />CONDITIONS WHICH CAN BE OBSERVED. ADDITIONAL COSTS WILL NOT BE ALLOWED FOR
<br />CORRECTION OF ITEMS WHICH CAN BE OBSERVED AND THEREFORE SHOULD BE INCLUDED IN
<br />HIS BID. THE CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION WORK REQUIRED TO
<br />COMPLETE THIS PROPOSED PROJECT.
<br />2.THE NOTES AND DRAWINGS CONTAINED ON THIS SHEET DESCRIBE IN A GENERAL SENSE THE
<br />EXTENT OF ITEMS TO BE MODIFIED, REMOVED OR INSTALLED. THIS DESCRIPTION DOES NOT
<br />NECESSARILY INCLUDE A DESCRIPTION OF ITEMS TO BE REPAIRED OR REFINISHED AS A RESULT
<br />OF THIS REMOVAL OR MODIFICATION. IN THE ABSENCE OF ANY SPECIFIC DIRECTION, THE
<br />CONTRACTOR SHALL REPAIR THE AFFECTED AREA(S) TO A CONDITION EQUAL TO THE ADJACENT
<br />AREA(S) AND/OR SIMILAR EXISTING CONDITIONS ON PROJECT.
<br />3.THE CONTRACTOR SHALL PROVIDE DUST AND DEBRIS CONTROL THROUGHOUT THE PROJECT'S
<br />CONSTRUCTION. THE CONTRACTOR SHALL COORDINATE HIS WORK WITH THE BUILDING OWNER
<br />TO PROVIDE THE LEAST INTERRUPTION OF EXISTING BUILDING OPERATIONS. COORDINATE WITH
<br />THE OWNER THE LOCATION OF ON-SITE STORAGE AND STAGING.
<br />4.NOT ALL REQUIRED PATCHING AND/OR REPAIRS ARE SPECIFICALLY NOTED ON THIS PLAN.
<br />5.COORDINATE DEMOLITION WORK WITH NEW PROPOSED FLOOR PLANS.
<br />6.CONTRACTOR SHALL DISCARD AND DISPOSE OF ALL DEMOLISHED ITEMS.
<br />7.EXISTING PIPING AND ELECTRICAL OR COMMUNICATION CONDUITS WHICH INTERFERE WITH THE
<br />WORK SHALL BE RE-ROUTED BY THE CONTRACTOR.
<br />HOT WATER
<br />FIXTURE CONNECTION SCHEDULE
<br />WASTEFIXTURESYM
<br />BRANCH
<br />COLD WATERTRAPVENT
<br />ROUGH
<br />LLAVATORY
<br />SSINK
<br />WCWATER CLOSET (F.T.)
<br />MSUTILITY SINK
<br />DFDRINKING FOUNTAIN
<br />TPTRAP PRIMER
<br />SHSHOWER
<br />BRANCH ROUGH BRANCH ROUGH
<br />2"
<br />2"
<br />4"
<br />2"
<br />2"
<br />--
<br />2"
<br />1-1/2"
<br />3"
<br />2"
<br />1-1/4"
<br />--
<br />2"
<br />1-1/2"
<br />--
<br />2"
<br />--
<br />2"
<br />1-1/2"
<br />--
<br />1/2"
<br />1/2"
<br />1-1/4"
<br />3/4"
<br />1/2"
<br />1/2"
<br />3/4"
<br />1-1/2"1-1/2"
<br />1-1/4"1-1/4"
<br />1-1/2"
<br />1-1/2"
<br />1-1/2"1-1/2"
<br />1/2"
<br />1/2"
<br />1"
<br />3/4"
<br />1/2"
<br />1/2"
<br />1/2"
<br />1/2"
<br />1/2"
<br />--
<br />3/4"
<br />--
<br />--
<br />3/4"
<br />1/2"
<br />1/2"
<br />--
<br />3/4"
<br />--
<br />--
<br />1/2"
<br /> INSULATION AND ALL-SERVICE-JACKET
<br /> INSULATION (2" DIA. PIPE AND LARGER): INSULATE HW & HWR WITH 2" FIBERGLASS
<br />TDL TOTAL DEVELOPED LENGTH
<br />LICENSED A RCHITECT
<br />STATEOF CALIFORNIA
<br />No. C 31423
<br />TH
<br />I
<br />S
<br />
<br />D
<br />R
<br />A
<br />W
<br />I
<br />N
<br />G
<br />
<br />I
<br />S
<br />
<br />M
<br />E
<br />A
<br />N
<br />T
<br />
<br />T
<br />O
<br />
<br />B
<br />E
<br />
<br />P
<br />R
<br />I
<br />N
<br />T
<br />E
<br />D
<br />
<br />3
<br />0
<br />"
<br />X
<br />4
<br />2
<br />"
<br />.
<br />
<br />
<br />A
<br />T
<br />
<br />A
<br />N
<br />Y
<br />
<br />O
<br />T
<br />H
<br />E
<br />R
<br />
<br />S
<br />I
<br />Z
<br />E
<br />,
<br />
<br />D
<br />I
<br />S
<br />R
<br />E
<br />G
<br />A
<br />R
<br />D
<br />
<br />R
<br />E
<br />F
<br />E
<br />R
<br />E
<br />N
<br />C
<br />E
<br />S
<br />
<br />T
<br />O
<br />
<br />S
<br />C
<br />A
<br />L
<br />E
<br />.
<br />© ASPEN STREET 2026
<br />KEY PLAN
<br />N
<br />B C D E F G H I J
<br />8
<br />K L
<br />10
<br />IS
<br />S
<br />U
<br />E
<br />D
<br />SCALE:
<br />JOB:
<br />SHEET NO.
<br />AGENCY NO.
<br />AGENCY APPROVALS
<br />ON
<br />FO
<br />R
<br />DRAWING TITLE
<br />DR. BY:
<br />215021.51
<br />AS SHOWN
<br />Modesto, CA 95351
<br />w w w . n e x u s e n g i n e e r i n g . n e t
<br />Tel: 209.572.7399 Fax: 209.236.1579
<br />1400 Lone Palm Ave, Suite A
<br />Consulting Mechanical Engineers
<br />HVAC . Plumbing/Piping . Fire Sprinklers
<br />Process/Plant Engineering . Refrigeration
<br />PH
<br />O
<br />E
<br />N
<br />I
<br />X
<br />
<br />H
<br />O
<br />U
<br />S
<br />E
<br />OR
<br />A
<br />N
<br />G
<br />E
<br />
<br />C
<br />O
<br />U
<br />N
<br />T
<br />Y
<br />IN
<br />T
<br />E
<br />R
<br />I
<br />O
<br />R
<br />
<br />A
<br />N
<br />D
<br />
<br />E
<br />X
<br />T
<br />E
<br />R
<br />I
<br />O
<br />R
<br />TE
<br />N
<br />A
<br />N
<br />T
<br />
<br />I
<br />M
<br />P
<br />R
<br />O
<br />V
<br />E
<br />M
<br />E
<br />N
<br />T
<br />S
<br />BU
<br />I
<br />L
<br />D
<br />I
<br />N
<br />G
<br />S
<br />
<br />C
<br />
<br />&
<br />
<br />D
<br />12
<br />0
<br />7
<br />
<br />E
<br />
<br />F
<br />R
<br />U
<br />I
<br />T
<br />
<br />S
<br />T
<br />R
<br />E
<br />E
<br />T
<br />SA
<br />N
<br />T
<br />A
<br />
<br />A
<br />N
<br />A
<br />,
<br />
<br />C
<br />A
<br />
<br />9
<br />2
<br />7
<br />0
<br />1
<br />CITY RESUBMITTAL 01
<br />2/6/2026
<br />P000
<br />PLUMBING LEGEND,
<br />SCHEDULES, & NOTES
<br />PLUMBING FIXTURE SCHEDULE
<br />MARK DESCRIPTION
<br />L-1
<br />WC-1
<br />SH-1
<br />LAVATORY: WALL MOUNT, VITREOUS CHINA, WHITE, 21-1/4" x 18-1/8", FRONT OVERFLOW, SINGLE HOLE, DRILLED FOR
<br />CONCEALED ARM CARRIER, KOHLER "KINGSTON" #K-2007.
<br />FAUCET: INTEGRAL SPOUT, CHROME PLATED, SINGLE HOLE, DECK MOUNTED, MANUAL SINGLE LEVER CONTROL, 0.5
<br />GPM OUTLET, LEAD FREE, CHICAGO #2200-E2805ABCP
<br />THERMOSTATIC MIXING VALVE: CHICAGO #131-ABNF
<br />CARRIER: ZURN Z1231, EXCEPT WHERE INSTALLATION AT EXISTING WALL IS IMPRACTICAL, USE WALL BRACKETS.
<br />INSTALL PER ACCESSIBILITY REQUIREMENTS & PROVIDE GRID STRAINER, P-TRAP, SUPPLIES & STOPS
<br />SHOWER: SURROUND BY OTHERS, SEE ARCHITECTURAL PLANS.
<br />SHOWER/HAND SHOWER SYSTEM WITH PRESSURE-BALANCING MIXING VALVE WITH LEVER HANDLE, INTEGRAL SERVICE
<br />STOPS, ADJUSTABLE STOP SCREW TO LIMIT HANDLE TURN, NON-SHARED DIVERTER VALVE, SHOWER HEAD WITH ARM &
<br />FLANGE, WALL/HAND SHOWER WITH IN-LINE VACUUM BREAKER, FLEXIBLE 5' METAL HOSE, WALL CONNECTION AND FLANGE,
<br />TWO WALL HOOKS FOR HAND SHOWER MOUNTING (INSTALL ONLY ONE).
<br />PROVIDE WITH OPTIONAL 1.5 GPM FLOW RATE RESTRICTOR, SYMMONS "TEMPTROL" #96-500-V-X-1.5-NS
<br />INSTALL PER ACCESSIBILITY REQUIREMENTS. DO NOT PROVIDE OR INSTALL VERTICAL SLIDER BAR.
<br />WATER CLOSET: FLOOR MOUNT, VITREOUS CHINA, ELONGATED BOWL, TWO-PIECE TANK TYPE, WHITE, 1.28 GPF, INTEGRAL
<br />TRAP, 12" ROUGH IN, WITH SOFT CLOSE SEAT AND COVER, 16.5" RIM HEIGHT, AMERICAN STANDARD "CADET 3" #3378128ST
<br />PLUMBING EQUIPMENT SCHEDULE
<br />MARK DESCRIPTION
<br />TMV-1
<br />ET-1
<br />CP-1 CIRCULATION PUMP: STAINLESS BODY, LEAD FREE, MAX 70W, 10 GPM @ 18 FT HEAD, MANUAL SPEED CONTROLS, 120V
<br />DISCONNECT BY ELECTRICAL, NSF 61, BELL & GOSSETT "ECOCIRC" #20-18 SS
<br />EXPANSION TANK: 2.0 GALLON TANK VOLUME, 0.9 MAX ACCEPTANCE VOLUME, BUTYL DIAPHRAGM BLADDER, MAX
<br />OPERATING TEMP = 200°F, MAX WORKING PRESSURE = 150 PSI, FACTORY PRE-CHARGED TO 55 PSI, 27 LBS OP.
<br />WEIGHT, WELDED STEEL CONSTRUCTION, AMTROL "THERM-X-TROL" #ST-5C-DD.
<br />THERMOSTATIC MIXING VALVE: 3/4" MPT INLETS/OUTLET, LEAD FREE BRONZE BODY, INTEGRAL CHECK VALVES, 1.0 GPM
<br />MIN, 10 PSI DROP AT 10 GPM, ASSE 1017, NSF 61, MAX 200°F INLET, SET TO 120°F, WITH SHIPPED LOOSE MOUNTING
<br />BRACKET, SHUTOFF VALVE & DIAL THERMOMETER, LEONARD #TM-26-BDT-LF
<br />S-1
<br />SINK: COUNTER MOUNTED, SINGLE BOWL, 18 GA. TYPE 304 SS, 25" x 21", 6" DEPTH, (1) CENTER FAUCET HOLE, (1) SIDE FAUCET
<br />HOLE, WITH #J35GS BASKET STRAINERS, JUST #SLADA-2133A60-J
<br />FAUCET: CHROME PLATED, 10" SWING SPOUT, SINGLE LEVER HOT/COLD MIXING, PROVIDE 1.8 GPM AERATING OUTLET, WITH
<br />SIDE SPRAY, CHICAGO #2301ABCP
<br />PROVIDE SUPPLIES AND ANGLE STOPS.
<br />INSTALL PER ACCESSIBILITY REQUIREMENTS. PROVIDE WALL CLEANOUT.
<br />L-2
<br />LAVATORY: DROP IN, VITREOUS CHINA, WHITE, 20-1/4" x 17-1/2", FRONT OVERFLOW, SINGLE FAUCET HOLE,
<br />KOHLER "PENNINGTON" #K-2196-0
<br />FAUCET: INTEGRAL SPOUT, CHROME PLATED, SINGLE HOLE, DECK MOUNTED, MANUAL SINGLE LEVER CONTROL, 0.5 GPM
<br />OUTLET, LEAD FREE, CHICAGO #2200-E2805ABCP
<br />MIXING VALVE: ASSE 1070 CERTIFIED, CHICAGO #131-ABNF
<br />PROVIDE P-TRAP, GRID STRAINER, SUPPLIES, AND ANGLE STOPS. INSTALLED PER ACCESSIBILITY REQUIREMENTS.
<br />WH-1
<br />WATER HEATER: NATURAL GAS, 100 GAL ASME TANK, 199 MBH INPUT, MODULATING BURNER, ULTRA LOW NOX
<br />(SCAQMD RULE 1146.2 COMPLIANT), 0" INSTALL CLEARANCE TO SIDES AND REAR, DIRECT VENT CONDENSING TYPE
<br />WITH NEUTRALIZER KIT, 120V RECEPTACLE POWER, SET TO 140°F, STATE #SUF100 199NE(A)
<br />WATER CLOSET: FLOOR MOUNT, VITREOUS CHINA, ELONGATED BOWL, TWO-PIECE TANK TYPE, WHITE, 1.28 GPF, INTEGRAL
<br />TRAP, 12" ROUGH IN, WITH SOFT CLOSE SEAT AND COVER, 16.5" RIM HEIGHT, AMERICAN STANDARD "CADET 3" #3378128ST
<br />INSTALL PER ACCESSIBILITY REQUIREMENTS.
<br />WC-2
<br />UTILITY SINK: CAST IRON, WALL MOUNT WITH FLOOR SUPPORT, 2" TRAP WITH FRONT INTEGRAL CLEANOUT, 22"x18"x11"
<br />DEEP BASIN, RIM MOUNTS AT 26-1/4" ABOVE FLOOR, BACK SPLASH WITH NO FAUCET HOLES, S.S. RIM GUARD. AMERICAN
<br />STANDARD "LAKEWELL" #7692.000 WITH #7798.020 TRAP
<br />FAUCET: WALL MOUNT, ADJUSTABLE 8" CENTERS, MHT OUTLET, VACUUM BREAKER, BUCKET HOOK, UPPER WALL BRACE,
<br />INTEGRAL SUPPLY STOPS WITH SPRING CHECK VALVES, WING HANDLES, NSF 61, T&S BRASS #B-0665-BSTP
<br />US-1
<br />WH-2
<br />WATER HEATER: NATURAL GAS, 60 GAL ASME TANK, 120 MBH INPUT, MODULATING BURNER, ULTRA LOW NOX (SCAQMD
<br />RULE 1146.2 COMPLIANT), 0" INSTALL CLEARANCE TO SIDES AND REAR, DIRECT VENT CONDENSING TYPE WITH
<br />NEUTRALIZER KIT, 120V RECEPTACLE POWER, SET TO 140°F, STATE #SUF60 120NE(A)
<br />TMV-2
<br />THERMOSTATIC MIXING VALVE: 3/4" MPT INLETS/OUTLET, LEAD FREE BRONZE BODY, INTEGRAL CHECK VALVES, 0.5 GPM
<br />MIN, 10 PSI DROP AT 6 GPM, ASSE 1017 AND 1070, NSF 61, MAX 200°F INLET, SET TO 120°F, WITH SHIPPED LOOSE
<br />MOUNTING BRACKET & DIAL THERMOMETER, LEONARD #370-LF-BRKT-DT
<br />DRINKING FOUNTAIN: DUAL HEIGHT, BOTTLE FILLER, REFRIGERATED, FILTER, 370W, 115V/60HZ, ELKAY #LZSTL8WSSP-PFDF-1
<br />ALTERNATE WHERE APPROVED BY OWNER: ABS DWV, SOLVENT WELDED, PER ASTM D2661
<br />FLOOR SINK: CAST IRON BODY, ACID RESISTANT, 8" x 8" x 6" DEEP, 2" NO-HUB OUTLET, 1/2 GRATE, ZURN #Z1910FS-1
<br />FLOOR DRAIN: C.I. BODY WITH CLAMPING COLLAR, ADJUSTABLE 5" SQUARE NICKEL/BRONZE GRATE, 2" OUTLET, ZURN #FD-2321-STFD-1
<br />SH-2
<br />SHOWER: SURROUND TO BE PREFABRICATED KNOCKDOWN TYPE, FIBERGLASS FAUX TILE FINISH, WITH SOAP LEDGE,
<br />2-1/2" SEMI-PERMANENT THRESHOLD ADAPTER, WITH NO-CAULK BRASS DRAIN (MODIFY EXISTING SANITARY SEWER
<br />BELOW FLOOR AS NECESSARY), BEST BATH #5LRS6030B75B
<br />PROVIDE VALVE & HARDWARE KIT: HAND SHOWER ON 1-1/4" GRAB BAR SLIDER, VACUUM BREAKER, 60" HOSE, SUPPLY
<br />ELBOW, & MIXING VALVE WITH SHUTOFF POSITION, SYMMONS #KGB30QSS9600
<br />ACCESSIBILITY NOT REQUIRED.
|