My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1610 E St Andrew Place Unit# 240 - Plan
PBA
>
Building
>
ProjectDox
>
S
>
St Andrew Pl
>
1610 E St Andrew Pl Unit# 240
>
1610 E St Andrew Place Unit# 240 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/8/2026 5:00:09 AM
Creation date
5/8/2026 5:00:04 AM
Metadata
Fields
Template:
Plan
Permit Number
101126519
Full Address
1610 E St Andrew Pl Unit# 240
Street Number
1610
Street Direction
E
Street Name
St Andrew
Street Suffix
Pl
Unit Number
240
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
FB <br />1 <br />(E) <br />(E <br />) <br />(E)(E) <br />(E <br />) <br />(E <br />) <br />(E <br />) <br />(E <br />) <br />(E <br />) <br />(E <br />) <br />(E <br />) <br />(E <br />) <br />(E <br />) <br />(E) <br />(E) <br />(E <br />) <br />(E <br />) <br />(E <br />) <br />(E <br />) <br />(E <br />) <br />(E <br />) <br />(E <br />) <br />(E <br />) <br />(E <br />) <br />(E <br />) <br />(E) <br />(E) <br />(E) <br />(E <br />) <br />(E) <br />(E) <br />(E <br />) <br />(E <br />) <br />(E <br />) <br />(E <br />) <br />(E <br />) <br />(E <br />) <br />(E)(E) <br />(E)(E) <br />(E <br />) <br />(E <br />) <br />(E <br />) <br />(E <br />) <br />(E <br />) <br />(E <br />) <br />(E)(E) <br />FE <br />C <br />FEC <br />(E <br />) <br />(E <br />) <br />(E <br />) <br />(E <br />) <br />(E) <br />(E <br />) <br />(E <br />) <br />(E <br />) <br />(E) <br />(E <br />) <br />J <br />J <br />(E) <br />(E)(E) <br />(E <br />) <br />J <br />J <br />(E <br />) <br />(E)(E) <br />(E <br />) <br />(E)(E <br />) <br />(E)(E <br />) <br />(E)(E <br />) <br />JJJJJJ <br />J (E)(E)(E <br />) <br />(E <br />) <br />FE <br />C <br />J <br />J <br />J <br />J <br /> <br />J <br />J <br /> <br />J <br /> <br />J <br />1. REFER TO G0.01 FOR SYMBOL LEGEND. <br />2. REFER TO G0.03 FOR GENERAL NOTES. <br />3. ALL DIMENSIONS ARE FROM FACE OF FINISH TO FACE OF FINISH, UON. <br />4. REMOVE ALL ABANDONED POWER AND SIGNAL CABLING BACK TO SOURCE AND SAFE OFF. <br />5. REMOVE FLOORING FINISHES AND WALL FINISHES THROUGHOUT AREA OF WORK, UON. <br />A. EXISTING WALL PROTECTION AND CORNER GUARDS TO REMAIN UNLESS OTHERWISE NOTED. <br />6. PROVIDE PROTECTION FOR EXISTING FINISHES TO REMAIN. <br />7. GC SHALL PATCH AND REPAIR AREAS WHERE DEMOLITION OR DAMAGE OCCURRED. REFINISH DISTURBED AREAS TO <br />MATCH ADJACENT CONDITION. EXTEND PATCH TO NEAREST NATURAL BREAK POINT. <br />8. GC TO PATCH AND REPAIR DAMAGED FIRE PROOFING ON STRUCTURAL AND FIRE RATED ASSEMBLIES. MATCH <br />EXISTING FIRE RATING. <br />9. REMOVE OR COVER ALL EXISTING PERIMETER WINDOW BLINDS PRIOR TO COMMENCEMENT OF DEMOLITION. CLEAN <br />AND UNCOVER OR REINSTALL AT COMPLETION OF CONSTRUCTION. <br />10. CONSULT WITH LANDLORD REGARDING SALVAGE AND REUSE OF BUILDING STANDARD ELEMENTS NOT REQUIRED <br />FOR NEW CONSTRUCTION. <br />11. ANY DEMOLITION DRAWINGS AND NOTES ARE PROVIDED FOR CONVENIENCE AND INFORMATION ONLY AND ARE NOT <br />INTENDED TO REPRESENT THE COMPREHENSIVE STATE OF THE BUILDING(S). VERIFY THE EXISTING STATE OF THE <br />BUILDING(S) FINISHES AND BUILDING SYSTEMS. <br />12. CONTRACTOR TO COORDINATE AND VERIFY ALL DEMOLITION WITH ALL ALTERATION PLANS. <br />13. FOLLOWING DEMOLITION, ALL EXISTING DIMENSIONS AND CONDITIONS ARE TO BE CHECKED BY THE CONTRACTOR <br />FOR CONFORMANCE WITH THE REQUIREMENTS OF THE NEW CONSTRUCTION. ANY INCONSISTENCIES OR <br />UNFORESEEN CONDITIONS ARE TO BE SUBMITTED TO THE ARCHITECT FOR REVIEW PRIOR TO THE COMMENCEMENT <br />OF WORK. <br />14. CONTRACTOR TO REMOVE ALL DEMOLISHED MATERIALS AND ITEMS FROM THE SITE IN ACCORDANCE WITH ALL <br />APPLICABLE AGENCY CODES AND REGULATIONS. <br />15. CONTRACTOR SHALL TAKE SPECIAL CARE TO PRESERVE THOSE ELEMENTS THAT ARE TO REMAIN. ANY ITEMS THAT <br />ARE TO BE RE-USED MUST BE STORED AND PROTECTED AS REQUIRED FOR RE-USE. <br />16. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE EXISTING STRUCTURE. <br />17. CONTRACTOR SHALL PROVIDE, ERECT AND MAINTAIN ALL TEMPORARY BARRIERS AND GUARDS, AND ALL <br />TEMPORARY SHORING AND BRACING AS REQUIRED BY ALL CITY AND STATE REGULATIONS. <br />18. WHERE SCHEDULED TO BE DEMOLISHED, EXISTING FLOOR BOXES TO BE SAFED OFF AND CAPPED WITH A FLUSH TO <br />FLOOR PLATE OR MANUFACTURER RECOMMENDED CAP AND COVERED WITH SCHEDULED FLOOR FINISH. WHERE <br />BOXES OCCUR AT EXPOSED CONCRETE, BOX TO BE REMOVED AND PATCHED BACK WITH CONCRETE. <br />19. WHERE EXISTING POWER/DATA WALL OUTLETS ARE TO BE DEMOLISHED, WALL IS TO BE PATCHED, REPAIRED, AND <br />PREPPED ACCORDINGLY. <br />DEMOLISHED CONSTRUCTION <br />EXISTING CONSTRUCTION <br />A A <br />2 <br />2 <br />4 <br />4 <br />5 <br />5 <br />A.9 A.9 <br />C C <br />D D <br />3 <br />3 <br />1 <br />1 <br />E E <br />F F <br />G G <br />E.2 E.2 <br />B.2 B.2 <br />OPEN OFFICE <br />200 <br />STORAGE <br />213 <br />5' - 0"6' - 6" <br />12 <br />' <br /> <br />- <br /> <br />4 <br />" <br /> <br />6 <br />' <br /> <br />- <br /> <br />1 <br />0 <br />" <br />1/16" = 1'-0"1LEVEL 02 - PLAN, DEMO - MATERIAL CONVEYOR <br />N <br />ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND <br />UNPUBLISHED WORK OF THE ARCHITECT AND MAY NOT BE DUPLICATED, USED, OR DISCLOSED <br />WITHOUT WRITTEN CONSENT OF ARCHITECT. COPYRIGHTED. <br />PROJECT NO. CHECKED BY <br />SHEET NO. <br />SCALE @ ARCH E1 <br />SHEET NAME <br />CLIENT NAME <br />ARCHITECT'S STAMP <br />PROJECT TEAM <br />KEY PLAN <br />4/ <br />1 <br />5 <br />/ <br />2 <br />0 <br />2 <br />6 <br /> <br />2 <br />: <br />3 <br />1 <br />: <br />1 <br />9 <br /> <br />P <br />M <br />Au <br />t <br />o <br />d <br />e <br />s <br />k <br /> <br />D <br />o <br />c <br />s <br />: <br />/ <br />/ <br />C <br />o <br />l <br />l <br />e <br />c <br />t <br />o <br />r <br />s <br /> <br />- <br /> <br />S <br />N <br />A <br /> <br />4 <br />. <br />0 <br />/ <br />s <br />n <br />a <br />1 <br />6 <br />1 <br />0 <br />p <br />h <br />4 <br />_ <br />R <br />V <br />T <br />26 <br />. <br />r <br />v <br />t <br />As indicated23008.00 <br />AD2.22 -MC <br />sna1610ph4 -PHASE 4 <br />1610 E ST ANDREW PL, SUITE 240 <br />SANTA ANA, CA 92705 <br />LEVEL 02 -DEMOLITIAN PLANS <br />COLLECTORS <br />- <br />KEYNOTES <br />12" = 1'-0" <br />SHEET NOTES LEGEND <br />ISSUE RECORD <br />∆ DATE REASON FOR ISSUE BY <br />2026-0130 ISSUE FOR PERMIT <br />B 2026-0317 REVISION 1
The URL can be used to link to this page
Your browser does not support the video tag.