My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1610 E St Andrew Place Unit# 240 - Plan
PBA
>
Building
>
ProjectDox
>
S
>
St Andrew Pl
>
1610 E St Andrew Pl Unit# 240
>
1610 E St Andrew Place Unit# 240 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/8/2026 5:00:09 AM
Creation date
5/8/2026 5:00:04 AM
Metadata
Fields
Template:
Plan
Permit Number
101126519
Full Address
1610 E St Andrew Pl Unit# 240
Street Number
1610
Street Direction
E
Street Name
St Andrew
Street Suffix
Pl
Unit Number
240
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
FE <br />C <br />FE <br />C <br />FEC <br />FE <br />C <br />FEC <br />FEC <br />FE <br />C <br />FEC <br />FE <br />C <br />FEC <br />FEC FE <br />C <br />FEC <br />FEC <br />FE <br />C <br />FEC <br />FE <br />C <br />FEC <br />FE <br />C <br />A A <br />2 <br />2 <br />4 <br />4 <br />5 <br />5 <br />A.9 A.9 <br />C C <br />D D <br />3 <br />3 <br />1 <br />1 <br />E E <br />F F <br />G G <br />E.2 E.2 <br />B.2 B.2 <br />A4.21 - MC <br />2 <br />4' - 2" <br />13 <br />' <br /> <br />- <br /> <br />7 <br />" <br />5 <br />" <br />EL <br />0 <br />1 <br />MTL <br />CONVEYOR <br />115 <br />7' - 9" <br />W30A <br />W30A <br />W30AW30A <br />W30A <br />LOADING / <br />STORAGE <br />147 <br />(E) ELEC <br />190 <br />(E) STORAGE <br />149 <br />HALLWAY <br />150 <br />HALLWAY <br />1120 <br />VESTIBULE <br />146 <br />A114 <br />A A <br />2 <br />2 <br />4 <br />4 <br />5 <br />5 <br />A.9 A.9 <br />C C <br />D D <br />3 <br />3 <br />1 <br />1 <br />E E <br />F F <br />G G <br />E.2 E.2 <br />B.2 B.2 <br />OPEN OFFICE <br />200 <br />(E) ELEC <br />201 <br />CONFERENCE <br />202 <br />OFFICE <br />203 <br />OFFICE <br />204 <br />OFFICE <br />205 <br />STORAGE <br />206 <br />STORAGE <br />207 <br />STORAGE <br />208 <br />STORAGE <br />209 <br />MTRL <br />CONVEYOR <br />215 <br />CONFERENCE <br />210 <br />MDF <br />211 <br />OFFICE <br />212 <br />(E) ELEC <br />214 <br />OFFICE GROWTH <br />213 <br />(E) STAIRS <br />ALIGN <br />A4.21 - MC <br />1 <br />9' <br /> <br />- <br /> <br />4 <br />" <br /> <br />1 <br />3 <br />' <br /> <br />- <br /> <br />7 <br />" <br />7' - 9" 4' - 1" <br />EL <br />0 <br />2 <br />W30A <br />W30A <br />W30A <br />W30A <br />W30A <br />1. REFER TO G0.01 FOR SYMBOL LEGEND. <br />2. REFER TO G0.03 FOR GENERAL NOTES. <br />3. SEE A7.00 AND A7.01 FOR TYPICAL INTERIOR FRAMING DETAILS. <br />4. LOCATE NEW PARTITIONS ON CENTER LINE OF MULLION OR ALIGNED WITH COLUMN OR <br />WALL, UON. SEE TYPICAL PARTITION DETAILS ON SHEET A7.02. <br />5. ALL PARTITIONS SHALL BE TYPE W01A, UON. <br />6. ALL GLAZING SHALL BE TYPE G01, UON. PROVIDE GLAZING SEALANT COLOR SAMPLE FOR <br />ARCHITECT’S REVIEW. GLAZING STOP COLOR TO MATCH FRAME. <br />7. REPAIR OR REPLACE DAMAGED OR MISSING GYPSUM BOARD ON EXISTING PARTITIONS AND <br />COLUMNS TO REMAIN. MATCH EXISTING PARTITION TYPE AND FINISHES. <br />8. PROVIDE BACKING AS NEEDED TO SUPPORT WALL HUNG ITEMS INCLUDING, BUT NOT <br />LIMITED TO, SIGNAGE, RESTROOM ACCESSORIES, GRAB BARS, EQUIPMENT, AND FURNITURE. <br />9. GC SHALL FIELD CUT MILLWORK AS NECESSARY TO ALLOW ACCESS TO WALL POWER AND <br />SIGNAL LOCATIONS. FIELD VERIFY CONDITIONS. <br />10. ALL SIGNAGE IS BY TENANT’S VENDOR. <br />11. PER CBC 703.7: FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS AND <br />SMOKE PARTITIONS OR ANY OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS OR <br />PENETRATIONS SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR <br />STENCILING. SUCH IDENTIFICATION SHALL: <br />A. BE LOCATED IN ACCESSIBLE CONCEALED FLOOR, FLOOR-CEILING OR ATTIC <br />SPACES. <br />B. BE LOCATED WITHIN 15 FEET OF THE END OF EACH WALL AND AT INTERVALS NOT <br />EXCEEDING 30 FEET (914 MM) MEASURED HORIZONTALLY ALONG THE WALL OR <br />PARTITION; AND <br />C. INCLUDE LETTERING NOT LESS THAN 3 INCH IN HEIGHT WITH A MINIMUM 3/8-INCH <br />STROKE IN CONTRASTING COLOR INCORPORATING THE SUGGESTED WORDING: “FIRE <br />AND/OR SMOKE BARRIER--PROTECT ALL. <br />12. NO HAZARDOUS MATERIALS ARE TO BE STORED IN THE BUILDING. <br />13. WINDOW COVERINGS: PROVIDE ALLOWANCE TO CLEAN, REPAIR AND REPLACE AS NEEDED. <br />DOOR TAG <br />WALL TAG <br />STOREFRONT / CURTAIN WALL TAG <br />XX <br />CHANGE IN ELEVATION LEVEL <br />101 <br />APPLIANCE, PLUMBING, AND EQUIPMENT TAGS <br />1i <br />1i <br />EXISTING CONSTRUCTION <br />1 HR RATED PARTITION <br />NEW CONSTRUCTION <br />N <br />ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND <br />UNPUBLISHED WORK OF THE ARCHITECT AND MAY NOT BE DUPLICATED, USED, OR DISCLOSED <br />WITHOUT WRITTEN CONSENT OF ARCHITECT. COPYRIGHTED. <br />PROJECT NO.CHECKED BY <br />SHEET NO. <br />SCALE @ ARCH E1 <br />SHEET NAME <br />CLIENT NAME <br />ARCHITECT'S STAMP <br />PROJECT TEAM <br />KEY PLAN <br />4/ <br />1 <br />5 <br />/ <br />2 <br />0 <br />2 <br />6 <br /> <br />2 <br />: <br />3 <br />1 <br />: <br />1 <br />0 <br /> <br />P <br />M <br />Au <br />t <br />o <br />d <br />e <br />s <br />k <br /> <br />D <br />o <br />c <br />s <br />: <br />/ <br />/ <br />C <br />o <br />l <br />l <br />e <br />c <br />t <br />o <br />r <br />s <br /> <br />- <br /> <br />S <br />N <br />A <br /> <br />4 <br />. <br />0 <br />/ <br />s <br />n <br />a <br />1 <br />6 <br />1 <br />0 <br />p <br />h <br />4 <br />_ <br />R <br />V <br />T <br />26 <br />. <br />r <br />v <br />t <br />As indicated23008.00 <br />A2.21 -MC <br />sna1610ph4 -PHASE 4 <br />1610 E ST ANDREW PL, SUITE 240 <br />SANTA ANA, CA 92705 <br />LEVELS 01 & 02 -OVERALL <br />PLANS <br />COLLECTORS <br />- <br />ISSUE RECORD <br />∆ DATE REASON FOR ISSUE BY <br />2026-0130 ISSUE FOR PERMIT <br />B 2026-0317 REVISION 1 <br />1/16" = 1'-0"1LEVEL 01 - PLAN, MATERIAL CONVEYOR PLAN <br />1/16" = 1'-0"2LEVEL 02 - PLAN, MATERIAL CONVEYOR PLAN <br />MARK DESCRIPTION DETAIL # <br />W30A 6" C-H STUD SHAFT WALL: ACOUSTICAL; 1 HR RATED (UL145,U469) 1/A6.00 <br />SHEET NOTES LEGEND <br />WALL SCHEDULE <br />KEYNOTES <br />A114 ACCESSIBLE ROUTE TO AREA OF ALTERATION. REFER TO SHEET G0.20 FOR ACCESSIBLE <br />ROUTE OF EXISTING SITE PLAN
The URL can be used to link to this page
Your browser does not support the video tag.