Laserfiche WebLink
A <br />DESIGN BASIS: <br />B C <br />Is] <br />STRUCTURAL NOTES <br />E <br />CITY OF SANTA ANA <br />tanning a�cn Buifidingency <br />2 <br />3 <br />A. APPLICABLE CODES: <br />2022 CBC <br />B. GRAVITY LOADS: <br />UNIFORM <br />1. LIVE LOAD: <br />A. ROOF LIVE LOAD <br />20 psf <br />2. DEAD LOAD: <br />A. ROOF DEAD LOAD <br />15 psf <br />C. LATERAL LOADS: <br />1. WIND LOADS (STRENGTH LEVEL FORCES): <br />METHOD OF ANALYSIS <br />DIRECTIONAL PROCEDURE <br />BASIC WIND SPEED <br />95 mph <br />EXPOSURE CATEGORY <br />C <br />RISK CATEGORY <br />II <br />WIND IMPORTANCE FACTOR <br />Iw= 1.0 <br />INTERNAL PRESSURE COEFFICIENT <br />GCpi = ±0.18 <br />2. EARTHQUAKE LOADS (STRENGTH LEVEL FORCES): <br />METHOD OF ANALYSIS <br />EQUIVALENT LATERAL FORCE PROCEDURE <br />SEISMIC FORCE RESISTING SYSTEM: <br />STRUCTURAL WOOD PANEL <br />RESPONSE MODIFICATION FACTOR <br />R = 6.5 <br />RISK CATEGORY <br />II <br />SEISMIC IMPORTANCE FACTOR <br />IE= 1.0 <br />SITE CLASS <br />D, DEFAULT <br />SEISMIC DESIGN CATEGORY <br />D <br />SITE COORDINATE: <br />A. LATITUDE: <br />33.720290 <br />B. LONGITUDE: <br />-117.8626960 <br />SS 1.278g (MAPPED MCE* SPECTRAL RESPONSE ACCELERATION @ SHORT PERIODS) <br />S1= 0.457g (MAPPED MCE* SPECTRAL RESPONSE <br />ACCELERATION @ 1.0 SEC.) <br />Fa=1.6 <br />Fv= 1.84 <br />V=CSW=0.0210W <br />* MCE = MAX. CONSIDERED EARTHQUAKE RESPONSE (MCER) GROUND MOTION <br />ABBREVIATIONS: <br />A/C <br />Air Conditioning <br />F.O. <br />Face Of <br />P.C.F. <br />A.B. <br />Anchor Bolt <br />F.O.C. <br />Face of Concrete <br />PENT. <br />A.C.I. <br />American Concrete Institute <br />F.O.M. <br />Face of Masonry <br />PL. <br />ADJ. <br />Adjacent <br />F.O.S. <br />Face of Steel (Studs) <br />It <br />A.F.F. <br />Above Finished Floor <br />F.S. <br />Far Side <br />PLY. <br />AL. <br />Aluminum <br />FT. <br />Feet <br />PNL. <br />ALT. <br />Alternate <br />FTG <br />Footing <br />P.S.F. <br />A.P.A. <br />American Plywood Institute <br />FUT. <br />Future <br />P.S.I. <br />ARCH. <br />Architect, Architectural <br />GA <br />Gauge <br />P.T. <br />A.S.T.M. <br />American Society for <br />GAL <br />Galvanized <br />R.,RAD. <br />Testing Materials <br />GD <br />Grade, Grading <br />REF. <br />BLW. <br />Below <br />GLB <br />Glued Laminated Beam <br />REINF. <br />BETWN. <br />Between <br />G.T. <br />Girder Truss <br />REQ. <br />BLK. <br />Block <br />GUSS. <br />Gusset <br />RET. <br />BLKG <br />Blocking <br />HD <br />Hold Down <br />REV. <br />BM <br />Beam <br />HDR <br />Header <br />RF. <br />B.N. <br />Boundry Nail <br />HGR <br />Hanger <br />RFT. <br />B.O.F. <br />Bottom of Footing <br />HORIZ <br />Horizontal <br />RM. <br />BOTT <br />Bottom <br />H.P. <br />High Point <br />R.O. <br />C <br />Channel <br />HT <br />Height <br />R.S. <br />CBC <br />California Building Code <br />H.V.A.0 <br />Heating/Ventilation/ <br />R.T. <br />C.I.P. <br />Cast -in -Place <br />Air Conditioning <br />S. <br />C.J. <br />Control Joint / Ceiling Joist <br />IBC <br />International Building Code <br />SCHED. <br />CLG. <br />Ceiling <br />I.D. <br />Inside Diameter <br />SEC. <br />CLR. <br />Clear <br />IN <br />Inch <br />SEP. <br />CMU <br />Concrete Masonry Unit <br />INCL <br />Include <br />SHT. <br />COL. <br />Column <br />INFO <br />Information <br />SIM. <br />CONC. <br />Concrete <br />INS <br />Insulated <br />SLRS <br />CONN. <br />Connection <br />INT. <br />Interior <br />S.M.S. <br />CONST. <br />Construction <br />JST <br />Joist <br />SPEC. <br />CONT. <br />Continuous <br />JT. <br />Joint <br />SQ. <br />CSK <br />Counter Sink <br />L <br />Length, Angle <br />S.S. <br />CTR'D <br />Centered <br />LAM <br />Laminated <br />STD. <br />DBL <br />Double <br />LB <br />Pound <br />STIFF. <br />DEG <br />Degree <br />LG <br />Long <br />STL. <br />DEM <br />Demolish, Demolition <br />L.L. <br />Live Load <br />STRUCT <br />DEP <br />Depressed <br />L.L.H. <br />Long Leg Horizontal <br />SUSP. <br />DIA <br />Diameter <br />L.L.V. <br />Long Leg Vertical <br />SYM <br />DIAG <br />Diagonal <br />L.P. <br />Low Point <br />T&B <br />DIM <br />Dimension <br />LVR <br />Louver <br />T&G <br />DO <br />Ditto <br />MAS <br />Masonry <br />T.C. <br />D.T. <br />Drag Truss <br />MAX <br />Maximum <br />THK <br />DTL. <br />Detail <br />M.B. <br />Machine Bolt <br />T.N. <br />DWG <br />Drawing <br />MECH <br />Mechanical <br />T.O.B. <br />DWL <br />Dowel <br />IVIED <br />Medium <br />T.O.C. <br />(E) <br />Existing <br />MEZZ <br />Mezzanine <br />T.O.F. <br />EA. <br />Each <br />MFR <br />Manufacturer <br />T.O.P. <br />E.F. <br />Each Face <br />MIN <br />Minimum <br />T.O.S. <br />E.J. <br />Expansion Joint <br />MISC <br />Miscellaneous <br />T.O.W <br />ELEC <br />Electric, Electrical <br />M.O. <br />Masonry Opening <br />T.S. <br />EL. <br />Elevation <br />MT. <br />Mount, Mounted, Mounting <br />TYP. <br />E.N. <br />Edge Nail <br />MTL <br />Metal <br />U.N.O. <br />EQ. <br />Equal <br />N. <br />North <br />U.O.N. <br />EQPT. <br />Equipment <br />N.I.C. <br />Not In Contract <br />V.B. <br />E.S. <br />Each Side <br />NO. <br />Number <br />VERT. <br />E.W. <br />Each Way <br />NOM <br />Nominal <br />W/ <br />EXP. <br />Expansion <br />N.S. <br />Near Side <br />W. <br />EXT. <br />Exterior <br />N.T.S. <br />Not To Scale <br />WD. <br />F.F. <br />Finished Floor <br />O.C. <br />On Center <br />W/0 <br />F.G. <br />Finish Grade <br />O.D. <br />Outside Diameter <br />W.P. <br />FIN <br />Finish, Finished <br />O.H. <br />Opposite Hand, Overhead <br />W.PT. <br />F.J. <br />Floor Joist <br />OPNG <br />Opening <br />WT. <br />FLR <br />Floor <br />PAR. <br />Parallel <br />W.W.F. <br />F.N. <br />Field Nail <br />P.C.C. <br />Precast Concrete <br />W.W.M. <br />FND <br />Foundation <br />If this sheet is smaller than 24" high by 36" wide then it has been <br />reduced. <br />Pounds per Cubic Foot <br />Penetration <br />Plate, Property Line <br />Plate <br />Plywood <br />Panel <br />Pounds per Square Foot <br />Pounds per Square Inch <br />Pressure Treated <br />Radius <br />Reference <br />Reinforcement <br />Required <br />Return <br />Revision, Revised <br />Roof <br />Rafters <br />Room <br />Rough Opening <br />Rough Sawn <br />Roof Truss <br />South <br />Schedule <br />Section <br />Separation <br />Sheet <br />Similar <br />Seismic Lateral Resisting System <br />Sheet Metal Screw <br />Specification(s) <br />Square <br />Stainless Steel <br />Standard <br />Stiffener <br />Steel <br />Structural <br />Suspended <br />Symmetrical <br />Top & Bottom <br />Tongue & Groove <br />Top of Curb <br />Thick, Thickness <br />Toe Nail <br />Top of Beam <br />Top of Concrete <br />Top of Footing <br />Top of Parapet <br />Top of Steel <br />Top of Wall <br />Tube Steel <br />Typical <br />Unless Noted Otherwise <br />Unless Otherwise Noted <br />Vapor Barrier <br />Vertical <br />With <br />West <br />Wood <br />Without <br />Water Proof <br />Working Point <br />Weight <br />Welded Wire Fabric <br />Welded Wire Mesh <br />1.0 GENERAL NOTES: <br />1.0.1 EXAMINE THE STRUCTURAL DRAWINGS AND NOTIFY THE ENGINEER ANY DISCREPANCIES IN <br />ELEVATIONS, DIMENSIONS, AND SITE CONDITIONS INCLUDING ERRORS BEFORE PROCEEDING WITH <br />ANY WORK. OMISSIONS AND CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE DRAWINGS <br />(AND SPECIFICATIONS) SHALL BE RESOLVED IN WRITING WITH THE ENGINEER/ARCHITECT PRIOR TO <br />START OF WORK. <br />1.0.2 THE DRAWINGS REPRESENT THE COMPLETED STRUCTURE. THEY DO NOT INDICATE THE METHOD <br />OF CONSTRUCTION. PROVIDE ALL MEASURES AND MEANS NECESSARY TO PROTECT PERSONS AND <br />THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED <br />TO BRACING, SHORING, ETC. BSERVATION VISITS BY THE ARCHITECT OR ENGINEER DOES NOT <br />INCLUDE REVIEW OF THESE MEASURES. <br />1.0.3 TYPICAL DETAILS SHALL BE USED WHENEVER APPLICABLE WHETHER SPECIFICALLY REFERENCED <br />OR NOT. <br />1.0.4 DRAWINGS SHALL NOT BE SCALED FOR CONSTRUCTION PURPOSES. <br />1.0.5 NO PIPES OR DUCTS SHALL BE PLACED IN STRUCTURAL MEMBERS UNLESS SPECIFICALLY DETAILED <br />OR APPROVED BY THE ENGINEER. <br />1.0.6 REFER TO ARCHITECTURAL DRAWINGS FOR THE FOLLOWING: <br />a. SIZE AND LOCATION OF ALL DOOR AND WINDOW OPENINGS, UNLESS OTHERWISE NOTED. <br />b. SIZE AND LOCATION OF INTERIOR AND EXTERIOR NON -BEARING PARTITIONS. <br />c. SIZE AND LOCATION OF CURBS, FLOOR DRAINS, SLOPES, DEPRESSED AREAS, CHANGES IN LEVEL, <br />RAMPS, CHAMFERS, GROOVES, INSERTS, ETC., EXCEPT AS SHOWN. <br />d. SIZE AND LOCATION OF FLOOR AND ROOF OPENINGS, EXCEPT AS SHOWN. <br />e. FLOOR AND ROOF FINISHES. <br />f. STAIR FRAMING AND DETAILS, EXCEPT AS SHOW <br />g. DIMENSIONS NOT SHOWN ON STRUCTURAL DRAWINGS. <br />1.0.7 REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR THE FOLLOWING: <br />a. PIPE RUNS, SLEEVES, HANGERS, TRENCHES, SLAB OPENINGS, ETC., EXCEPT AS SHOWN OR <br />NOTED. <br />b. ELECTRICAL CONDUITS, BOXES, OUTLETS. <br />c. CONCRETE INSERTS FOR ELECTRICAL, MECHANICAL AND PLUMBING FIXTURES. <br />d. SIZE AND LOCATION OF MACHINE AND EQUIPMENT BASES, ANCHOR BOLTS, ETC. <br />1.0.8 ASTM REFERENCES ARE FROM THE LATEST ISSUE AND LATEST REVISION, UNLESS OTHERWISE <br />NOTED. <br />1.0.9 INVESTIGATE THE SITE DURING CLEARING AND EXCAVATION FOR UNSUITABLE CONDITIONS, <br />UNCONSOLIDATED AND UNDOCUMENTEDLLS, BURIED STRUCTURES, UTILITIES, ETC., AND <br />IMMEDIATELY NOTIFY THE ARCHITECT/ENGINEER OF ANY SITE CONDITIONS NOT REFLECTED ON <br />THE DRAWINGS OR DIFFERENT FROM MAXIMUM OR INIMUM DIMENSIONS INDICATED, INCLUDING <br />CONFLICT IN GRADES, ADVERSE SOIL CONDITION GROUNDWATER PRESENT, DEEPENED FOOTINGS, <br />UNCOVERED AND NEXPECTED UTILITY LINES, ETC. <br />1.0.10 CONSTRUCTION MATERIALS, IF PLACED ON STRUCTURAL MEMBERS, HALL BE SPREAD OUT SUCH <br />THAT THE LOADING DOES NOT EXCEED THE DESIGN LIVE LOADS. PROVIDE SHORING AND BRACING <br />WHER CONSTRUCTION LOADING EXCEEDS THE DESIGN STRENGTH OF THE STRUCTURAL MEMBERS <br />OR THE STRUCTURAL STRENGTH HAS NOT BEEN ATTAINED OR THE STRUCTURE IS NOT COMPLETE. <br />1.0.11 DETERMINE THE LOCATION OF UTILITY SERVICES IN AREAS TO BE EXCAVATED BEFOR BEGINNING <br />EXCAVATION. EXERCISE EXTREME CAUTION IN EXCAVATING AND TRENCHING. DAMAGE CAUSED AS <br />A SULT OF FAILING TO EXACTLY LOCATE AND PRESERVE ALL EXISTING UNDERGROUND UTILITIES IS <br />THE RESPONSIBILITY OF THE CONTRACTOR. <br />1.0.12 THE CAD DRAWING FILES ARE THE PROPERTY OF THE STRUCTURAL ENGINEER AND WILL NOT BE <br />RELEASED TO THE CONTRACTOR OR SUBCONTRACTOR FOR THEIR USE. <br />1.013 STRUCTURAL DRAWINGS TO BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS BY: <br />2.0 FOUNDATION: <br />2.0.1 FOUNDATION DESIGN IS BASED ON A CODE MINIMUM <br />2.0.2 FOOTING DEPTHS SHOWN ARE A MINIMUM AND MAY REQUIRE DEEPENIN PER DIRECTION OF THE <br />BUILDING INSPECTOR <br />2.0.3 THE MAXIMUM ALLOWABLE SOIL BEARING PRESSURE SHALL BE AS FOLLOWS: <br />CONTINUOUS AND PAD FOOTINGS <br />TYPE OF <br />SHORT <br />SOIL FILL/ <br />D+LL <br />TERM <br />BEDROCK <br />CONT. FOOTING <br />NATIVE <br />1500 psf <br />2000 psf <br />PAD FOOTING <br />NATIVE <br />1500 psf <br />2000 psf <br />2.0.4 FOOTINGS SHALL BEAR ON FIRM UNDISTURBED OR COMPACTED SOIL. <br />MINIMUM FOOTING DIMENSIONS AND EMBEDMENTS SHALL BE AS FOLLOWS: <br />MIN. FOOTING SIZES <br />MIN. FTG. WIDTH <br />MIN. FTG. THICKNESS <br />MIN. EMBEDMENT <br />CONT. EXT. FTG. <br />12 INCHES <br />12 INCHES <br />24 INCHES <br />CONT. INT. FTG. <br />12 INCHES <br />12 INCHES <br />24 INCHES <br />PAD FTG. <br />24 INCHES <br />12 INCHES <br />24 INCHES <br />2.0.5 THE FOOTING EXCAVATIONS SHALL BE KEPT FREE FROM LOOSE MATERIAL AND STANDING WATER <br />AND SHALL BE NEAT AND TRUE TO LINE BEFORE ANY CONCRETE IS PLACED. <br />2.0.6 UTILITY TRENCH BACKFILL SHALL BE MECHANICALLY COMPACTED IN LAYERS TO THE APPROVAL OF <br />THE GEOTECHNICAL ENGINEER. <br />2.0.7 ALL ABANDONED FOOTINGS, UTILITIES, ETC. THAT INTERFERE WITH NEW CONSTRUCTION SHALL BE <br />REMOVED. <br />2.0.8 WALL FOOTINGS CAST AGAINST EARTH ARE CONTINUOUS POURED CONCRETE WITH CONTINUOUS <br />REINFORCING PLACED 3" CLEAR OF BOTTOM AND SIDES. <br />2.0.9 UNLESS OTHERWISE NOTED, WALL FOOTINGS ARE CENTERED UNDER WALLS AND COLUMN <br />FOOTINGS UNDER COLUMNS. <br />3.0 CONCRETE: <br />3.0.1 CEMENT SHALL CONFORM TO ASTM C150, TYPE II/V. <br />3.0.2 AGGREGATES FOR NORMAL WEIGHT CONCRETE SHALL CONFORM TO ASTM C33, 1 1/21, <br />MAXIMUM SIZE. AGGREGATES FOR LIGHTWEIGHT CONCRETE SHALL CONFORM TO ASTM C330, <br />1" MAXIMUM SIZE. <br />3.0.3 THE MAXIMUM CONCRETE SLUMP SHALL BE PER SCHEDULE BELOW PRIOR TO THE ADDITION <br />OF ANY PLASTICIZING ADMIXTURES. <br />3.0.4 ADMIXTURES MAY NOT BE USED WITHOUT PRIOR APPROVAL OF THE ENGINEER. ADMIXTURES <br />USED TO INCREASE THE WORKABILITY OF THE CONCRETE SHALL NOT REDUCE THE STRENGTH <br />OF CONCRETE. FLY ASH (POZZOLAN) IF PERMITTED BY SPECIFICATIONS SHALL NOT EXCEED <br />25% FOR SLAB ON GRADE AND 25% FOR ALL OTHER CONCRETE. <br />3.0.5 READY -MIX CONCRETE SHALL BE MIXED AND DELIVERED IN ACCORDANCE WITH ASTM C94. <br />3.0.6 ALL REINFORCING BARS AND INSERTS SHALL BE SECURED IN PLACE PRIOR TO PLACING <br />CONCRETE. <br />3.0.7 CONDUITS EMBEDDED HORIZONTALLY IN THE SLAB SHALL HAVE AN OUTSIDE DIAMETER NO <br />GREATER THAN 1/3 THE THICKNESS OF THE SLAB. CONDUIT SHALL NOT BE EMBEDDED IN A <br />SLAB THAT IS LESS THAN 31/2" THICK. EXCEPT FOR LOCAL OFFSETS, MIN. CLEAR DISTANCE <br />BETWEEN CONDUITS SHALL BE 6". <br />3.0.8 NON-STRUCTURAL STEEL MEMBERS EMBEDDED IN CONCRETE SHALL BE GALVANIZED OR <br />PAINTED. ALL DAMAGED GALVANIZED AREAS SHALL BE REPAIRED PRIOR TO EMBEDMENT. <br />3.0.9 MINIMUM CONCRETE COMPRESSIVE STRENGTHS AT 28 DAYS, AND MAXIMUM SLUMPS SHALL BE <br />AS FOLLOWS: <br />MIN. fc <br />MAX. SLUMP <br />WIC <br />SLAB ON GRADE <br />FOOTINGS <br />3,000 psi <br />3,000 psi <br />4" +A" <br />4" +/-1" <br />0.45 <br />0.45 <br />NOTE: 2500 psi CONCRETE ASSUMED IN THE DESIGN. NO SPECIAL INSPECTION REQUIRED. <br />3.0.10 PROVIDE CONSTRUCTION OR CONTROL JOINTS IN SLAB ON GRADE. <br />3.1 REINFORCING STEEL: <br />3.1.1 DETAILING, FABRICATION AND ERECTION OF REINFORCING BARS SHALL BE IN ACCORDANCE WITH <br />ACI MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES, ACI <br />315-LATEST ADOPTED EDITION. <br />3.1.2 ALL REINFORCING SHALL BE ADEQUATELY SUPPORTED TO PREVENT DISPLACEMENT BY CONCRETE <br />PLACEMENT OR WORKERS. <br />3.1.3 ALL REINFORCING BARS EXCEPT BARS TO BE WELDED SHALL CONFORM TO THE "STANDARD <br />SPECIFICATION FOR DEFORMED BILLET STEEL BARS FOR CONCRETE REINFORCEMENT", ASTM A615 <br />GRADE 60. <br />3.1.4 WELDED PLAIN WIRE REINFORCEMENT SHALL CONFORM TO "STANDARD SPECIFICATION FOR STEEL <br />WELDED WIRE REINFORCEMENT, PLAIN, FOR CONCRETE", ASTM A185. <br />3.1.5 WELDING OF REINFORCING BARS TO BE IN ACCORDANCE WITH "STRUCTURAL WELDING <br />CODE -REINFORCING STEEL", AWS D1.4. REINFORCING STEEL TO BE WELDED SHALL HAVE A MAXIMUM <br />CARBON EQUIVALENT (CE) OF 0.75. AND SHALL CONFORM TO ASTM A706. SPECIAL INSPECTION IS <br />REQUIRED. TESTING IS REQUIRED FOR ALL WELDS THICKER THAN 5/16" <br />3.1.6 WHERE REINF. BARS ARE CALLED OUT TO BE CONTINUOUS (CONT.) PROVIDE CONTINUOUS BARS OR <br />FULL SPLICES PER SPLICE TABLE SCHEDULE. IT IS CONTRACTOR'S OPTION TO PROVIDE CONTINUOUS <br />BARS WHERE SPLICES ARE SHOWN. <br />3.1.7 MESH SPLICES SHALL BE A MINIMUM OF TYPICAL GRID SPACING PLUS 2" (8" MINIMUM) MEASURED <br />BETWEEN CROSS WIRES. <br />3.1.8 ALL REINFORCING BAR BENDS SHALL BE MADE COLD. <br />3.1.9 UNLESS OTHERWISE SHOWN, WALL VERTICAL REINFORCING SHALL BE POSITIONED AT THE CENTER <br />OF THE WALL. <br />3.1.10 DOWELS BETWEEN FOOTINGS AND WALLS SHALL BE THE SAME GRADE, SIZE, AND SPACING AS <br />VERTICAL REINFORCING. <br />3.1.11 ALL REINFORCING BARS SHALL BE PROVIDED WITH THE FOLLOWING CONCRETE COVER: <br />CONCRETE CAST AGAINST AND PERMANENTY <br />EXPOSED TO EARTH: <br />CONCRETE EXPOSED TO EARTH OR WEATHER: 3" <br />NO.6 THROUGH NO.18 BAR <br />NO.5 BAR, W31 OR D31 WIRE, AND SMALLER 2" <br />CONCRETE NOT EXPOSED TO WEATHER OR IN <br />CONTACT WITH GROUND: <br />SLAB, WALL, JOIST: <br />NO.14 AND NO.18 BAR 1 1/2" <br />NO.11 BAR AND SMALLER 3/4" <br />BEAM, COLUNNS: <br />PRIMARY REINFORCEMENT, TIES, STIRRUPS, SPIRALS 1 1/2" <br />3.1.12 SLAB ON GRADE REINFORCEMENT SHALL BE POSITIONED AT MID -DEPTH. U.O.N. <br />0 <br />FOR <br />I <br />taster ID: <br />ate: <br />GARCIA RESIDENCE <br />ADU CONVERSION <br />N E <br />oQPpFESS/ONE <br />q <br />yQ J�NC HG�� Fyn <br />MARIA GARCIA z S4907LU <br />z m <br />2058 S OAK ST Exp. 09-30-27mT � <br />SANTA ANA, CA 92707 <br />�P <br />T 714.305.8928 'TF 0 <br />/2026 <br />Project Address <br />2058 S OAK ST <br />SANTA ANA, CA 92707 <br />Project Status <br />BKW STUDIO <br />13733 FRANCISCO DR <br />LA M I RADA, CA. 90638 <br />626.272.8479 <br />binhkwong@yahoo.com <br />Copyright @ 2025 <br />The ideas and designs represented herein and this drawing, all <br />prepared by BKW STUDIO, are for the use solely with respect to <br />this project and BKW STUDIO shall retain all common law, <br />statutory and other reserved rights including copyright and they <br />shall not be used by others for any other purpose without written <br />permission of BKW STUDIO. <br />client approval <br />principal in charge <br />issues / revisions <br />drawing title <br />STRUCTURAL NOTES <br />scale <br />project number <br />2025-038 <br />date <br />S001 <br />Plot Date: 01/27/2026 <br />File Path: <br />