1 <br />E <br />3 <br />NO <br />6.0 STRUCTURAL WOOD: <br />6.0.1 LUMBER SHALL BE GRADED IN ACCORDANCE WITH THE STANDARD GRADING RULES PPROVED BY THE BOARD OF <br />REVIEW OF THE AMERICAN LUMBER STANDARDS COMMITTEE & ERTIFIED FOR CONFORMANCE WITH U.S. <br />DEPARTMENT OF COMMERCE VOLUNTARY RODUCT. <br />6.0.2 ALL WOOD MEMBERS SHALL BE DOUGLAS FIR (DF) OR LARCH GRADE -MARKED BY A ECOGNIZED GRADING AGENCY <br />(WCLIB OR WWPA). LUMBER GRADES SHALL BE AS FOLLOWS: <br />LUMBER GRADES: <br />HORIZONTAL MEMBERS: <br />JOISTS AND RAFTERS: GRADE # 2 <br />BEAM: <br />WIDTH 4X GRADE # 2 <br />WIDTH 6X OR LARGER GRADE # 1 <br />HEADERS: GRADE # 2 <br />TOP PLATES: MATCH VERT. EMBERS <br />VERTICAL MEMBERS <br />2x4 STUDS: GRADE # 2 <br />POST: GRADE # 2 <br />6.0.3 ALL WOOD PRODUCT STRUCTURAL PANELS (PLYWOOD COMPOSITE, WAFER BOARD, ORIENTED STRAND BOARD, <br />STRUCTURAL PARTICLE BOARD) SHALL COMPLY WITH U.S. PRODUCT STANDARD DOC PS1 OR DOC PS2 (ANSI <br />A-199.1) OR SHALL COMPLY WITH THE AMERICAN PLYWOOD ASSOCIATION STANDARDS FOR APA STRUCTURAL. <br />PANELS WHICH MAY HAVE ANY EDGE OR SURFACE PERMANENTLY EXPOSED TO THE WEATHER OR TO MOISTURE <br />SHALL BE CLASSIFIED AS EXTERIOR. THE SPACING IN INCHES OF ROOF AND FLOOR SUPPORTS OVER WHICH <br />PANELS ARE APPLIED SHALL NOT EXCEED THE SPAN RATING STAMPED ON THE PANEL. PANEL THICKNESS AND <br />INDEX SHALL COMPLY WITH AND BE IDENTIFIED WITH THE APPROPRIATE GRADE MARK AS FOLLOWS: <br />WOOD PANEL SCHEDULE: <br />USE GRADE & GRADE MARKS <br />ROOF SHEATHING APA RATED SHEATHING ESPOSURE 1 <br />WALL SHEATHING APA RATED SHEATHING ESPOSURE 1 <br />CONFORMING WITH PS-1 <br />6.0.4 ROOF SHEATHING THICKNESS, GRADE, AND NAILING SHALL BE PER STRUCTURAL PLANS, CONFORMING TO <br />PRODUCT STANDARD PS-1, LATEST ADOPTED EDITION, INTERIOR TYPE WITH EXTERIOR GLUE. <br />6.0.5 FLOOR SHEATHING THICKNESS, GRADE, AND NAILING SHALL BE PER STRUCTURAL PLANS, CONFORMING TO <br />PRODUCT STANDARD PS-1, LATEST ADOPTED EDITION, TONGUE AND GROOVE, INTERIOR TYPE WITH EXTERIOR <br />GLUE. 2x BLOCKING MAY BE USED AT ALL UNSUPPORTED EDGES IN LIEU OF TONGUE AND GROOVE EDGES. <br />6.0.6 PLYWOOD SHEATHING SHALL BE LAID PERPENDICULAR TO FRAMING MEMBERS WITH 4'-0" JOINTS <br />STAGGERED AND CENTERED ON FRAMING MEMBERS. <br />6.0.7 PLYWOOD FLOOR SHEATHING SHALL BE GLUED TO ALL FRAMING MEMBERS WITH AN ADHESIVE <br />MEETING APA SPECIFICATION AFG-01, APPLIED IN ACCORDANCE WITH MANUFACTURER'S <br />RECOMMENDATIONS. <br />6.0.8 PLYWOOD NAILS SHALL BE SAME GAGE OR LARGER AS COMMON NAILS WITH LENGTHS AT LEAST EQUAL TO <br />LENGTH OF COMMON NAIL REQUIRED PLUS SHEATHING THICKNESS, UNLESS NOTED OTHERWISE. <br />6.0.9 ALL WOOD IN CONTACT WITH CONCRETE SHALL BE TREATED DOUGLAS FIR OR FOUNDATION REDWOOD. <br />EXTERIOR WALL SILL PLATES SHALL BE SECURED TO CONCRETE WITH 5/8"x10" LONG ANCHOR BOLTS WITH 7" <br />MINIMUM EMBEDMENT INTO CONCRETE AT A MAXIMUM SPACING OF 4'-0" O.C. AND 1'-0" FROM EACH END. FOR <br />SPECIAL CONDITIONS AT SHEAR WALL ANCHORAGE, SEE SHEAR WALL SCHEDULE. ALL HARDWARE INCLUDING <br />NAILS IN CONTACT W/ PRESSURE TREATED LUMBER SHALL BE HOT DIPPED GALVANIZED. <br />6.0.10 BOLT HOLES SHALL BE THE SAME SIZE AS THE NOMINAL SIZE OF BOLT USED PLUS 1/32"-1/16". IF BOLT HOLE IS <br />OVERSIZED, FILL HOLE WITH EPDXY. RE -TIGHTEN ALL NUTS PRIOR TO CLOSING IN WALL. <br />6.0.11 DO NOT BORE OR NOTCH JOISTS, RAFTERS, OR BEAMS, EXCEPT WHERE SHOWN IN DETAILS. OBTAIN ENGINEER'S <br />APPROVAL FOR ANY HOLES OR NOTCHES NOT DETAILED. HOLES THROUGH SILL PLATES, STUDS, AND DOUBLE <br />PLATES IN INTERIOR BEARING AND SHEAR WALLS SHALL NOT EXCEED 1/3 THE PLATE OR STUD WIDTH. USE BORED <br />HOLES LOCATED IN THE CENTER OF THE STUD OR PLATE. <br />6.0.12 NAILING SHALL COMPLY WITH NAILING SCHEDULE. NAILS EXPOSED TO WEATHER SHALL BE HOT -DIP GALVANIZED, <br />UNLESS OTHERWISE NOTED. <br />6.0.13 STANDARD CUT WASHERS SHALL BE USED UNDER BOLT HEADS AND NUTS AGAINST WOOD. 3"x3"xl/4" WASHER <br />SHALL BE USED UNDER BOLT HEADS OF ALL ANCHOR BOLTS. <br />6.0.14 ALL STUD PARTITIONS, OR WALLS OVER 10'-0" HIGH SHALL HAVE 2x BLOCKING, SAME WIDTH AS THE STUD, <br />PREFERABLY AT MID -HEIGHT BUT NOT TO EXCEED INTERVALS OF F-0". THIS BLOCKING MAY BE USED AS FIRE <br />BLOCKING. <br />6.0.15 PROVIDE SOLID BLOCKING AT ENDS AND AT SUPPORTS OF ALL FLOOR JOISTS AND ROOF RAFTERS AS WELL AS <br />UNDER PARTITIONS AND AT RIDGE LINE. PROVIDE DOUBLE FLOOR JOISTS UNDER PARALLEL PARTITIONS AND <br />SOLID BLOCKING AT PERPENDICULAR PARTITIONS. <br />6.0.16 TOP PLATES OF ALL BEARING WOOD STUD WALLS SHALL BE TWO PIECES, SAME SIZE AS STUDS AND LAPPED 4'-0" <br />MINIMUM WITH NOT LESS THAN 12-16d NAILS AT EACH SIDE OF TOP PLATE BREAK POINT WITH A MAXIMUM <br />SPACING OF 4" O.C. UNLESS OTHERWISE NOTED. <br />6.0.17 PROVIDE TWO (2) 2x STUDS AT SUPPORT LOCATIONS FOR ALL 48 OR LARGER BEAMS, UNLESS OTHERWISE <br />NOTED. <br />6.0.18 ALL STUDS SHALL HAVE FULL BEARING ON BOTTOM PLATE. ALL JOISTS, HEADERS, BEAMS, AND RAFTERS SHALL <br />HAVE A MINIMUM SOLID LEVEL BEARING OF 1 1/2" AT EACH END. <br />6.0.19 NOT LESS THAN THREE (3) STUDS SHALL BE INSTALLED AT EVERY CORNER OF AN EXTERIOR OR INTERIOR <br />BEARING WALL. <br />6.0.20 ALL BEAMS, JOISTS, RAFTERS, ETC. SHALL BE INSTALLED WITH THE CROWN SIDE UP. <br />6.0.21 BOLTS SHALL HAVE 7 DIAMETER MINIMUM END DISTANCE AND 4 DIAMETER MINIMUM EDGE DISTANCE UNLESS <br />OTHERWISE NOTED. <br />6.0.22 ALL FRAMING ANCHORS, POST CAPS, COLUMN BASES, HANGERS, ETC. SHALL BE MANUFACTURED BY SIMPSON <br />STRONG -TIE, OR APPROVED EQUAL. <br />6.0.23 PRESERVATIVE -TREATED DOUGLAS FIR SHALL BE NO.2 MINIMUM AND BEAR'AWPS' QUALITY MARK AND THE WCLIB <br />OR WWPA GRADE STAMP. CERTIFICATES ARE NOT ACCEPTABLE. <br />6.0.24 CUTS AND HOLES IN PRESSURE TREATED LUMBER SHALL BE TREATED PER AWPA 84. <br />6.0.24 CUTS AND HOLES IN PRESSURE TREATED LUMBER SHALL BE TREATED PER AWPA 84. <br />6.0.25 UNTREATED LUMBER SHALL BE DRY AND WELL SEASONED, AND THE MOISTURE CONTENT SHALL NOT EXCEED <br />19%. ALL LUMBER SHALL BE AIR SEASONED NOT LESS THAN 30 DAYS BEFORE BEING COVERED WITH FINISHING <br />MATERIAL. <br />6.0.26 FOUNDATIONS SUPPORTING WOOD SHALL EXTEND 6" MINIMUM ABOVE ADJACENT FINISH GRADE. <br />If this sheet is smaller than 24" high by 36" wide then it has been reduced. <br />B <br />IN <br />STRUCTURAL NOTES <br />6.4 LAG SCREW LEAD HOLES AND INSERTION: 6.7 FASTENING SCHEDULE: <br />6.4.1 PRE -BORED HOLES FOR LAG SCREWS SHALL HAVE THE SAME DIAMETER AS THE SHANK FOR THE <br />LENGTH OF THE SHANK AND FROM 60%%% TO 75%%% OF THE SHANK DIAMETER FOR THE <br />THREADED PORTION. THE HIGHER PERCENTAGE APPLIES TO LAG SCREWS OF LARGER <br />DIAMETERS. EXTRA LONG LAG SCREWS MAY REQUIRE SLIGHTLY LARGER LEAD HOLES TO <br />PREVENT SPLITTING AND TO FACILITATE TURNING. <br />6.4.2 LAG SCREWS SHALL BE INSERTED BY TURNING WITH A WRENCH. DRIVING WITH A HAMMER TEARS <br />THE WOOD FIBERS AND DAMAGES THE SCREW THREAD, SIGNIFICANTLY REDUCING THE LOAD <br />CARRYING CAPACITY OF THE SCREW AND THEREFORE IS NOT PERMITTED. SOAP OR OTHER <br />LUBRICANTS MAY BE USED TO FACILITATE INSERTION OF LAG SCREWS. <br />6.5 MACHINE APPLIED NAILING: <br />6.5.1 THE USE OF MACHINE NAILING FOR PLYWOOD IS SUBJECT TO A SATISFACTORY JOB SITE <br />DEMONSTRATION FOR EACH PROJECT AND THE APPROVAL OF THE PROJECT ENGINEER AND <br />THE QUALITY CONTROL SUPERVISOR. THE APPROVAL IS SUBJECT TO CONTINUED <br />SATISFACTORY PERFORMANCE. <br />6.5.2 NAIL HEADS SHALL NOT PENETRATE THE OUTER PLY MORE THAN WOULD BE NORMAL FOR A <br />HAND HAMMER. <br />6.5.3 EDGE DISTANCES SHALL BE MAINTAINED. SHINERS SHALL BE REPLACED. IF NAIL HEADS <br />PENETRATE THE OUTER PLY MORE THAN WOULD BE NORMAL FOR A HAND HAMMER OR IF <br />MINIMUM ALLOWABLE EDGE DISTANCES ARE NOT MAINTAINED THE PERFORMANCE WILL BE <br />DEEMED UNSATISFACTORY. <br />6.5.4 MACHINE NAILING WILL NOT BE APPROVED FOR PLYWOOD 5/16" OR LESS IN THICKNESS. <br />In] <br />DESCRIPTION OF BUILDING ELEMENTS <br />NUMBER AND TYPE OF FASTENER <br />SPACING AND <br />LOCATION <br />ROOF <br />1. BLOCKING BETWEEN CEILING JOISTS, <br />4-8d BOX (21/2" X 0.113"); OR 3-8d COMMON <br />RAFTERS OR TRUSSES TO TOP PLATE <br />(21/2" x 0.131"); OR 3-10d BOX (3" x 0.128"); <br />EACH END,TOENAIL <br />OR OTHER FRAMING BELOW <br />OR 3-3" x 0.131" NAILS; OR 3-3" 14 GAGE <br />STAPLES, 7/16" CROWN <br />2-8d COMMON (2 1/2"x0.131") 2-3" x 0.131" <br />BLOCKING BETWEEN RAFTERS OR <br />NAILS 2-3" 14 GAGE STAPLES <br />EACH END,TOENAIL <br />TRUSSES NOT AT THE WALL TOP <br />2-16d COMMON (3 1/2"0.162") 3-3" x 0.131" <br />PLATE, TO RAFTER OR TRUSS <br />NAILS 3-3" 14 GAGE STAPLES <br />END NAIL <br />FLAT BLOCKING TO TRUSS AND WEB <br />16d COMMON (3 1/2"0.162") @ 6" O.C. <br />FILLER <br />3" x 0.131" NAILS @ 6" O.C. 3" 14 <br />FACE NAIL <br />GAGE STAPLES @ 6" O.C. <br />4-8d BOX (21/2" X 0.113"); OR 3-8d COMMON <br />2. CEILING JOISTS TO TOP PLATE <br />(21/2" x 0.131"); OR 3-10d BOX (3" x 0.128"); <br />EACH JOIST, <br />OR 34' x 0.131" NAILS; OR 34' 14 GAGE <br />TOENAIL <br />STAPLES, 7/16" CROWN <br />3. CEILING JOIST NOT ATTACHED TO <br />3-16d COMMON (3 1/2"0.162"); OR 4-10d <br />PARALLEL RAFTER, LAPS OVER <br />BOX (3"0.128"); OR 4-3" x 0.131" NAILS; <br />FACE NAIL <br />PARTITIONS (NOT THRUST) (SEE <br />OR 4-3" 14 GAGE STAPLES, 7/16" CROWN <br />SECTION 2308.7.3.1, TABLE 2308,7,3,1) <br />4. CEILING JOIST ATTACHED TO <br />PARALLEL RAFTER (HEEL JOINT) (SEE PER TABLE 2308,7,3,1 FACE NAIL <br />SECTION 2308.7.3.1, TABLE 2308,7,3,1) <br />3-10d COMMON (3"0.148"); OR 4-10d BOX <br />5. COLLAR TIE TO RAFTER (3"x0.128"); OR 4-3" x 0.131" NAILS; OR 4-3" FACE NAIL <br />14 GAGE STAPLES, 7/16" CROWN <br />6. RAFTER OR ROOF TRUSS TO TOP 3-10d COMMON (3"0.148"); OR 3-16d BOX 2 TOENAILS ON ONE <br />PLATE (SEE SECTION 2308.7.5, (3 1/2"x0.135") OR 4-10d BOX (3"x0.128"); OR SIDE AND 1 TOENAIL <br />TABLE 2308.7.5) 4-3 x 0.131 NAILS; OR 4-3 14 GAGE ON OPPOSITE SIDE <br />STAPLES, 7/16" CROWN OF RAFTER OR <br />TRUSS <br />7. ROOF RAFTER TO RIDGE OR HIP <br />RAFTER; OR ROOD RAFTER TO 2-INCH <br />RIDGE BEAM <br />8. STUD TO STUD (NOT AT BRACED WALL <br />PANELS) <br />9. STUD TO STUD AND ABUTTING STUDS <br />AT INTERSECTING WALL CORNERS (AT <br />BRACE WALL PANELS) <br />10. BUILT-UP HEADER (2" TO 2" HEADER) <br />11. CONTINUOUS HEADER TO STUD <br />12. TOP PLATE TO TOP PLATE <br />13. TOP PLATE TO TOP PLATE, AT <br />END JOINTS <br />14. BOTTOM PLATE TO JOIST, RIM JOIST, <br />BAND JOIST OR BLOCKING (NOT AT <br />BRACED WALL PANEL) <br />15. BOTTOM PLATE TO JOIST, RIM JOIST, <br />BAND JOIST OR BLOCKING AT <br />BRACED WALL PANEL <br />16. STUD TO TOP OR BOTTOM PLATE <br />2-16d COMMON (3 1/2"0.162"); OR <br />3-16d BOX (31/2"0.128"); OR 3-3" x <br />0.131" NAILS; OR 3-3" 14 GAGE <br />STAPLES, 7/16" CROWN <br />3-10d COMMON (3 1/2"0.148"); OR <br />4-16d BOX (3 1/2"x0.135") OR 4-10d <br />BOX (3"0.128"); OR 4-3" x 0.131" <br />NAILS; OR 4-3" 14 GAGE STAPLES, <br />7/16" CROWN <br />WALL <br />16d COMMON (3 1/2"x0.162") <br />10d BOX (3"x0.128"); OR 3" x 0.131" <br />NAILS; OR 3-3" 14 GAGE STAPLES, <br />7/16" CROWN <br />16d COMMON (3 1/2"0.162"); OR <br />16d BOX (3 1 /2"x0.135"); OR <br />3" x 0.131" NAILS; OR <br />3-3" 14 GAGE STAPLES, 7/16" CROWN <br />16d COMMON (3 1/2"x0.162"); OR <br />16d BOX (3 1 /2"x0.135") <br />4-8d COMMON (21/2" x 0.131"); OR <br />4-10d BOX (3" x 0.128"); OR 5-8d BOX <br />(21/2" X 0.113") <br />16d COMMON (3 1/2"0.162") <br />10d BOX (3"x0.128"); OR 3" x 0.131" <br />NAILS; OR 3" 14 GAGE STAPLES, <br />7/16" CROWN <br />8-16D COMMON (31/2" x 0.162"); OR <br />12-16D BOX (31/2" X 0.135"); OR <br />12-10D BOX (3" x 0.128"); OR <br />12-3" x 0.131" NAILS; OR 12-3" <br />14 GAGE STAPLES, 7/16" CROWN <br />16d COMMON (3 1/2"0.162") <br />16d BOX (31/2"x0.135"); OR 3" x <br />0.131" NAILS; OR 3" 14 GAGE <br />STAPLES,7/16" CROWN <br />2-16d COMMON (3 1/2"0.162"); OR <br />3-16d BOX (3 1/2"x0.135"); OR 4-3" x <br />0.131" NAILS; OR 4-3" 14 GAGE <br />STAPLES,7/16" CROWN <br />3-16d BOX (31/2" X 0.135"); OR <br />4-8d COMMON (21/2" x 0.131"); OR <br />4-10d BOX (3" x 0.128"); OR 4-3" x <br />0.131" NAILS; OR 4-8d BOX (21/2" X <br />0.113"); OR 4-3" 14 GAGE STAPLES, <br />7/16" CROWN <br />2-16d COMMON (31/2" x 0.162"); OR <br />3-16d BOX (31/2" X 0.135"); OR <br />3-10d BOX (3" x 0.128"); OR 3-3" x <br />0.131" NAILS; OR 3-3" 14 GAGE <br />STAPLES, 7/16" CROWN <br />END NAIL <br />TOENAIL <br />24" O.C. FACE NAIL <br />16" O.C. FACE NAIL <br />16" O.C. FACE NAIL <br />12" O.C. FACE NAIL <br />16" O.C. EACH EDGE <br />FACE NAIL <br />12" O.C. EACH EDGE <br />FACE NAIL <br />TOENAIL <br />16" O.C. FACE NAIL <br />12" O.C. FACE NAIL <br />E <br />2-16d COMMON (3 1/2"0.162") OR <br />17. TOP PLATES, LAPS AT CORNERS <br />3-10d BOX (3"4.128"); OR <br />FACE NAIL <br />AND INTERSECTIONS <br />3-3" x 0.131" NAILS; OR <br />3-3" 14 GAGE STAPLES, 7/16" CROWN <br />3-8d BOX (21/2" X 0.113"); OR <br />18. 1" BRACE TO EACH STUD AND PLATE <br />2-8d COMMON (21/2" x 0.131"); OR <br />2-10d BOX (3" x 0.128"); OR <br />FACE NAIL <br />2-3" x 0.131" NAILS; OR <br />2-3" 14 GAGE STAPLES, 7/16" CROWN <br />3-8d BOX (21/2" X 0.113"); OR <br />19. 1"x6" SHEATHING TO EACH BEARING <br />2-8d COMMON (21/2" x 0.131"); OR <br />FACE NAIL <br />2-10d BOX (3" x 0.128"); OR <br />2-1 3/4" 16 GAGE STAPLES, 1" CROWN <br />3-8d COMMON (21/2" x 0.131"); OR <br />3-8d BOX (21/2" X 0.113"); OR <br />20. 1" x 8" AND WIDER SHEATHING <br />3-10d BOX (3" x 0.128"); OR <br />TO EACH BEARING <br />3-1 3/4" 16 GAGE STAPLES, 1" CROWN <br />FACE NAIL <br />WIDER THAN 1" x 8" 3-8d COMMON <br />(21/2" X 0.131 "); OR 4-8d BOX (21/2" x <br />0.113"); OR 3-10d BOX (3" x 0.128"); OR <br />4-13/4" 16 GAGE STAPLES, 1" CROWN <br />FLOOR <br />4-8d BOX (21/2" x 0.113"); OR 3-8d <br />21. JOIST TO SILL, TOP PLATE, OR GIRDER <br />COMMON (21/2" x 0.131"); OR FLOOR <br />3-10d BOX (3" x 0.128"); OR 3-3" x <br />TOENAIL <br />0.131" NAILS; OR 3-3" 14 GAGE <br />STAPLES, 7/16" CROWN <br />22. RIM JOIST, BAND JOIST, OR BLOCKING <br />8d COMMON (2 1/2"x0.113") <br />4" O.C.,TOENAIL <br />8d COMMON (21/2" x 0.131"); OR <br />TO TOP PLATE SILL OR OTHER <br />FRAMING BELOW <br />10d BOX (3" x 0.128"); OR 3" x 0.131" <br />6" O.C.,TOENAIL <br />NAILS; OR 3" 14 GAGE STAPLES, 7/16" <br />CROWN <br />23. 1"x6" SUB FLOOR OR LESS TO EACH <br />3-8d BOX (21/2" x 0.113"); OR <br />JOIST <br />2-8d COMMON (21/2" x 0.131"); OR <br />3-10d BOX (3" x 0.128"); OR <br />FACE NAIL <br />2-13/4" 16 GAGE STAPLES, 1" CROWN <br />24.2" SUB FLOOR TO JOIST OR GIRDER <br />3-16d BOX (31/2" x 0.135"); OR <br />BLIND AND FACE NAIL <br />2-16d COMMON (31/2" x 0.162") <br />25.2" PLANKS (PLANK & BEAM - FLOOR & <br />3-16d BOX (31/2" x 0.135"); OR <br />EACH BEARING, FACE NAIL <br />ROOF) <br />2-16d COMMON (31/2" x 0.162") <br />32" O.C., FACE NAIL AT TOP <br />20d COMMON (4"0.192"); <br />AND BOTTOM STAGGERED <br />ON OPPOSITE SIDES <br />26. BUILT-UP GIRDER AND BEAMS, 2" <br />10d BOX (3"0.128"); OR <br />24" O.C., FACE NAIL AT TOP <br />LUMBER LAYERS <br />3" x 0.131" NAILS; OR <br />AND BOTTOM STAGGERED <br />3" 14 GAGE STAPLES, 7/16" CROWN <br />ON OPPOSITE SIDES <br />AND: <br />2-20d COMMON (4"0.192"); OR <br />3-10d BOX (3"x0.128"); OR <br />END AND AT EACH SPLICE, <br />3-3" x 0.131" NAILS; OR <br />FACE NAIL <br />3-3" 14 GAGE STAPLES, 7/16" CROWN <br />3-16d COMMON (3 1/2"0.162"); OR <br />27. LEDGER STRIP SUPPORTING JOISTS <br />4-10d BOX (3"0.128"); OR <br />EACH JOIST OR RAFTER, <br />OR RAFTERS <br />4-3" x 0.131" NAILS; OR <br />FACE NAIL <br />4-3" 14 GAGE STAPLES, 7/16" CROWN <br />3-16d COMMON (31/2" x 0.162"); OR <br />28. JOIST TO BAND JOIST OR RIM JOIST <br />4-10d BOX (3" x 0.128"); OR <br />END NAIL <br />4-3" x 0.131" NAILS; OR <br />4-3" 14 GAGE STAPLES, 7/16" CROWN <br />2-8d COMMON (2 1/2"x0.131"); OR <br />29. BRIDGING OR BLOCKING TO JOISTS, <br />2-10d BOX (3"0.128"); OR <br />EACH END, TOENAIL <br />RAFTER OR TRUSS <br />2-3" x 0.131" NAILS; OR <br />2-3" 14 GAGE STAPLES, 7/16" CROWN <br />EACH SIDE OF END NOTES: <br />JOINT, FACE NAIL a. NAILS SPACED AT 6 INCHES AT INTERMEDIATE SUPPORTS WHERE SPANS ARE 48 INCHES OR MORE. FOR NAILING OF <br />(MINIMUM 24" LAP <br />WOOD STRUCTURAL PANEL AND PARTICLEBOARD DIAPHRAGMS AND SHEAR WALLS, REFER TO SECTION 2305. NAILS <br />SPLICE LENGTH <br />FOR WALL SHEATHING ARE PERMITTED TO BE COMMON, BOX OR CASING. <br />EACH SIDE OF END <br />b. SPACING SHALL BE 6 INCHES ON CENTER ON THE EDGES AND 12 INCHES ON CENTER AT INTERMEDIATE SUPPORTS <br />JOINT) <br />FOR NONSTRUCTURAL APPLICATIONS. PANEL SUPPORTS AT 16 INCHES (20 INCHES IF STRENGTH AXIS IN THE LONG <br />DIRECTION OF THE PANEL, UNLESS OTHERWISE MARKED). <br />16" O.C. FACE NAIL <br />c. WHERE A RAFTER IS FASTENED TO AN ADJACENT PARALLEL CEILING JOIST IN ACCORDANCE WITH THIS SCHEDULE <br />AND THE CEILING JOIST IS FASTENED TO THE TOP PLATE IN ACCORDANCE WITH THIS SCHEDULE, THE NUMBER OF <br />12" O.C. FACE NAIL <br />TOENAILS IN THE RAFTER SHALL BE PERMITTED TO BE REDUCED BY ONE NAIL. <br />d. RSRS-01 IS A ROOF SHEATHING RING SHANK NAIL MEETING THE SPECIFICATIONS IN ASTM F1667. <br />e. TABULATED FASTENER REQUIREMENTS APPLY WHERE THE ULTIMATE DESIGN WIND SPEED IS LESS THAN 140 MPH. <br />FOR WOOD STRUCTURAL PANEL ROOF SHEATHING ATTACHED TO GABLE -END ROOF FRAMING AND TO INTERMEDIATE <br />16" O.C. FACE NAIL <br />SUPPORTS WITHIN 48 INCHES OF ROOF EDGES AND RIDGES, NAILS SHALL BE SPACED AT 4 INCHES ON CENTER <br />WHERE THE ULTIMATE DESIGN WIND SPEED IS GREATER THAN 130 MPH IN EXPOSURE B OR GREATER THAN 110 MPH IN <br />EXPOSURE C. SPACING EXCEEDING 6 INCHES ON CENTER AT INTERMEDIATE SUPPORTS SHALL BE PERMITTED WHERE <br />THE FASTENING IS DESIGNED PER THE AWC NDS. <br />TOENAIL <br />f. FASTENING IS ONLY PERMITTED WHERE THE ULTIMATE DESIGN WIND SPEED IS LESS THAN OR EQUAL TO 110 MPH. <br />g. NAILS AND STAPLES ARE CARBON STEEL MEETING THE SPECIFICATIONS OF ASTM F1667. CONNECTIONS USING NAILS <br />AND STAPLES OF OTHER MATERIALS, SUCH AS STAINLESS STEEL, SHALL BE DESIGNED BY ACCEPTABLE ENGINEERING <br />PRACTICE OR APPROVED UNDER SECTION 104.11. <br />END NAIL <br />CITY OF SANTA ANA <br />Manming a�cn Buifiding�ge n cy <br />A d I <br />i:np <br />laster <br />ate: <br />GARCIA RESIDENCE <br />ADU CONVERSION <br />Nor- <br />NCE <br />�o QPpFESS/Oy ! <br />q <br />yQ JONHNCG�� <br />MARIA GARCIA W S4907 1-'m <br />2058 S OAK ST cc Exp. 09-30-27mT � <br />SANTA ANA, CA 92707 <br />�P <br />T 714.305.8928 �rF ° ` P/2026 <br />Project Address <br />2058 S OAK ST <br />SANTA ANA, CA 92707 <br />Project Status <br />BKW STUDIO <br />13733 FRANCISCO DR <br />LA M I RADA, CA. 90638 <br />626.272.8479 <br />binhkwong@yahoo.com <br />Copyright @ 2025 <br />The ideas and designs represented herein and this drawing, all <br />prepared by BKW STUDIO, are for the use solely with respect to <br />this project and BKW STUDIO shall retain all common law, <br />statutory and other reserved rights including copyright and they <br />shall not be used by others for any other purpose without written <br />permission of BKW STUDIO. <br />client approval <br />principal in charge <br />issues / revisions <br />drawing title <br />STRUCTURAL NOTES <br />scale <br />O <br />project number <br />2025-038 <br />date <br />S002 <br />Plot Date: 01/27/2026 <br />SING <br />