Laserfiche WebLink
VICINITY MAP <br />PROJECT <br />SITE <br />SUMMARY <br />ZONING:R-1 <br />LOT SIZE:6,350 SF <br />(E) GARAGE 414 SF <br />(E) GARAGE -UNPERMITTED:120 SF <br />(N) ADDITION 66 SF <br />PLOT RATIO:NO CHANGE <br />CONSTRUCTION TYPE:V-B <br />OCCUPANCY:SINGLE FAMILY RESIDENCE <br />NO. OF STORIES:1 <br />BUILDING HEIGHT:12' -1/4" <br />FEMA FLOOD ZONE:NO <br />MAIN HOUSE SRPINKLERED: NO <br />ADU SF / SFD SF: 600 / 1,119 = 53.6% <br />APPLICABLE CODES <br />2022 ADMINISTRATION CODE <br />2022 (CBC) CALIFORNIA BUILDING CODE VOL I & II <br />2022 CALIFORNIA RESIDENTIAL CODE <br />2022 CALIFORNIA ACCESSIBILITY STANDARDS CODE <br />2022 CALIFORNIA ELECTRICAL CODE <br />2022 CALIFORNIA PLUMBING CODE <br />2022 CALIFORNIA MECHANICAL CODE <br />2022 CALIFORNIA GREEN BUILDING STANDARDS CODE <br />2022 CALIFORNIA ENERGY CODE <br />2022 CALIFORNIA FIRE CODE <br />2022 CALIFORNIA REFERENCE CODE <br />1.THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO ANY <br />WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL-BOXES, TRANSFORMERS, VAULTS, <br />PUMPS, VALVES, METERS, APPURTENANCES, ETC.)OR TO THE LOCATION OF THE HOOK-UP THE <br />CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES, WETHER OR NOT THE LINES ARE <br />LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR <br />ADDITIONAL EXPENSES. <br />2. AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE ON THE <br />DOWNSTREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE <br />BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING (PER ORDINANCE 170,158) (SEPARATE <br />PLUMBING PERMIT IS REQUIRED). <br />3. PLUMBING FIXTURES ARE REQUIRED TO BE CONNECTED TO A SANITARY SEWER OR TO AN APPROVED <br />SEWAGE DISPOSAL SYSTEM (R306.3). <br />4.KITCHEN SINKS LAVATORIES, BATHTUBS, SHOWERS, BIDETS, LAUNDRY TUBS AND WASHING MACHINE <br />OUTLETS SHALL BE PROVIDED WITH HOT AND COLD WATER AND CONNECTED TO AN APPROVED WATER <br />SUPPLY (R306.4) <br />5. BATHTUB AND SHOWER FLOORS, WALLS ABOVE BATHTUBS WITH A SHOWERHEAD, AND SHOWER <br />COMPARTMENTS SHALL BE FINISHED WITH A NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL <br />EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE THE FLOOR (R307.2) <br />6. PROVIDE ULTRA-LOW FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS <br />AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION. <br />7. WATER HEATER MUST BE STRAPPED TO WALL. (SEC. 507.3, LAPC) <br />8. SMOKE DETECTORS SHALL BE PROVIDED FOR ALL DWELLING UNITS INTENDED FOR HUMAN OCCUPANCY, <br />UPON THE OWNER’S APPLICATION FOR A PERMIT FOR ALTERATIONS, REPAIRS OR ADDITIONS EXCEEDING <br />ONE THOUSAND DOLLARS ($1,000). (R314.6.2) <br />9. IN ACCORDANCE WITH SECTION R315.2. CARBON MONOXIDE ALARMS SHALL BE REQUIRED IN THE <br />SPECIFIC WELLING UNIT OR SLEEPING UNIT FOR WHICH THE PERMIT WAS OBTAINED. (R315.2.2) <br />10.EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH NATURAL LIGHT BY MEANS <br />OF EXTERIOR GLAZED OPENINGS IN ACCORDANCE WITH SECTION R303.1 OR SHALL BE PROVIDED WITH <br />ARTIFICIAL LIGHT THAT IS ADEQUATE TO PROVIDE AN AVERAGE ILLUMINATION OF 6 FOOT-CANDLES OVER <br />THE AREA OF THE ROOM AT A HEIGHT OF 30 INCHES ABOVE THE FLOOR LEVEL. (R303.1) <br />11. THE MINIMUM CEILING HEIGHT FOR HABITABLE SPACE, HALLWAYS, BATHROOMS, TOILET ROOMS OR <br />LAUNDRY ROOMS SHALL BE NOT LESS THAN 7 FEET (R305.1). <br />12. PROVIDE 15" MINIMUM BETWEEN THE CENTER OF WATER CLOSET TO ANY SIDE WALL. (CALIF PLUMB. <br />CODE 407.6) <br />13.BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS SHALL BE PROVIDED <br />NATURAL VENTILATION OR WITH MECHANICAL VENTILATION CAPABLE OF 50 CFM EXHAUSTED DIRECTLY <br />TO THE OUTSIDE. (R303.3) <br />14. HEATER SHALL BE CAPABLE OF MAINTAINING A MINIMUM ROOM TEMPERATURE OF 68°F AT A POINT 3 FEET <br />ABOVE THE FLOOR AND 2 FEET FROM EXTERIOR WALLS IN ALL HABITABLE ROOMS AT THE DESIGN <br />TEMPERATURE. (R303.9) <br />15. GLAZING IN THE FOLLOWING LOCATIONS SHALL BE SAFETY GLAZING CONFORMING TO THE HUMAN <br />IMPACT LOADS OF SECTION R308.3 (SEE EXCEPTIONS) (R308.4): <br />a. FIXED AND OPERABLE PANELS OF SWINGING, SLIDING AND BI-FOLD DOOR ASSEMBLIES. <br />16. GLAZING IN ENCLOSURES FOR OR WALLS FACING HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, <br />BATHTUBS AND SHOWERS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60 INCHES <br />MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. <br />17. LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS WITH A MINIMUM <br />FALL OF 6 INCHES WITHIN THE FIRST 10 FEET (R401.3). <br />18. DAMPPROOFING, WHERE REQUIRED, SHALL BE INSTALLED WITH MATERIALS AND AS REQUIRED IN <br />SECTION R406.1. <br />19. PROTECTION OF WOOD AND WOOD BASED PRODUCTS FROM DECAY SHALL BE PROVIDED IN THE <br />LOCATIONS SPECIFIED PER SECTION R317.1 BY THE USE OF NATURALLY DURABLE WOOD OR WOOD THAT <br />IS PRESERVATIVE TREATED IN ACCORDANCE WITH AWPA U1 FOR THE SPECIES, PRODUCT, PRESERVATIVE <br />AND END USE. PRESERVATIVES SHALL BE LISTED IN SECTION 4 OF AWPA U1. <br />20. ROOF GUTTERS SHALL BE PROVIDED WITH THE MEANS TO PREVENT THE ACCUMULATION OF LEAVES AND <br />DEBRIS IN THE GUTTER (705A.4) <br />21.(ROOF)(ATTIC)(EXTERIOR WALL) VENTS SHALL RESIST THE INTRUSION OF FLAME AND EMBERS INTO THE <br />ATTIC AREA OF THE STRUCTURE, OR SHALL BE PROTECTED BY CORROSION-RESISTANT, <br />NONCOMBUSTIBLE WIRE MESH WITH 1/4 –INCH (6 MM) OPENINGS OR ITS EQUIVALENT. VENTS SHALL NOT <br />BE INSTALLED IN EAVES AND CORNICES (706A.1, 706A.2, 706A.3, 7207.3) <br />22. EAVES AND SOFFITS SHALL MEET THE REQUIREMENTS OF SFM 12-7A-3 OR SHALL BE PROTECTED BY <br />IGNITION RESISTANT MATERIALS OR NONCOMBUSTIBLE CONSTRUCTION ON THE EXPOSED UNDERSIDE <br />(707A.5.5) <br />23. EXTERIOR WALLS SHALL BE APPROVED NONCOMBUSTIBLE OR IGNITION-RESISTANT MATERIAL, HEAVY <br />TIMBER, OR LOG WALL CONSTRUCTION OR SHALL PROVIDE PROTECTION FROM THE INTRUSION OF <br />FLAMES AND EMBERS IN ACCORDANCE WITH STANDARD SFM 12-7A-1 (704A.3) <br />24. EXTERIOR WALL COVERINGS SHALL EXTEND FROM THE TOP OF FOUNDATION TO THE ROOF, AND <br />TERMINATE AT 2-INCH (50.8 MM) NOMINAL SOLID WOOD BLOCKING BETWEEN RAFTERS AT ALL ROOF <br />OVERHANGS, OR IN THE CASE OF ENCLOSED EAVES, TERMINATE AT THE ENCLOSURE (704A.3.1) <br />25. EXTERIOR WINDOWS, WINDOW WALLS, GLAZE DOORS, AND GLAZED OPENINGS WITHIN EXTERIOR DOORS <br />SHALL BE INSULATING-GLASS UNITS WITH A MINIMUM OF ONE TEMPERED PANE, OR GLASS BLOCK UNITS, <br />OR HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN 20 MINUTES, WHEN TESTED ACCORDING TO <br />ASTM E 2010, OR CONFORM TO THE PERFORMANCE REQUIREMENTS OF SFM 12-7A-2 (708A.2.1) <br />26. EXTERIOR DOOR ASSEMBLIES SHALL CONFORM TO THE PERFORMANCE REQUIREMENTS OF STANDARD <br />SFM 12-7A-1 OR SHALL BE APPROVED NONCOMBUSTIBLE CONSTRUCTION, OR SOLID CORE WOOD HAVING <br />STILES AND RAILS NOT LESS THAN 1 3/8 INCHES THICK WITH INTERIOR FIELD PANEL THICKNESS NO LESS <br />THAN 1 ¼ INCHES THICK, OR SHALL HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN 20 MINUTES <br />WHEN TESTED ACCORDING TO ASTM E 2074. <br />27. THE SPACE BETWEEN THE ROOF COVERING AND ROOF DECKING SHALL BE CONSTRUCTED TO PREVENT <br />THE INTRUSION OF FLAMES AND EMBERS AND BE FIRE STOPPED PER 705A.2. <br />28. NO TRELLIS IS PERMITTED WITHIN 10 FEET OF THE PRIMARY STRUCTURE. <br />GENERAL NOTES <br />DIRECTORY <br />MECHANICAL ENGINEER <br />117 VIA VELAZQUEZ <br />SAN CLEMENTE, <br />CA 92672 <br />RAMIRO AQUIRRE <br />949.441.8177 <br />ELECTRICAL ENGINEER <br />6425 HUGES DR. <br />HUNTINGTON BEACH <br />CA 92647 <br />NORMAN NGUYEN <br />714.469.0723 <br />STRUCTURAL ENGINEER <br />27520 GLENWOOD DR. <br />MISSION VIEJO, <br />CA 92692 <br />HUNG NGUYEN, SE <br />949.354.445 <br />BKW STUDIO <br />13733 FRANCISCO DR. <br />LA MIRADA, <br />CA 90638 <br />BINH WONG <br />626.898.1671 <br />OWNER <br />2060 S OAK ST <br />SANTA ANA, <br />CA 92707 <br />MARIA GARCIA <br />714-305-8928 <br />SANTA ANA CITY ORDINANCE <br />DESIGN SHALL COMPLY WITH THE 2022 CBC, CMC, CPC, AND CEC AS <br />AMENDED BY CITY ORDINANCE 2022 TITLE 24 REGULATIONS <br />EFFECTIVE JAN 1, 2017 RESIDENTIAL BUILDINGS UNDERGOING ADDITIONS, <br />ALTERATION OR IMPROVEMENTS SHALL REPLACE NONCOMPLIANCE <br />PLUMBING FIXTURES WITH WATER -CONSERVING PLUMBING FIXTURES <br />PRIOR TO FINAL INSPECTION. THE REQUIREMENTS SHALL APPLY TO NEW <br />FIXTURE IN ADDITIONS OR AREAS OF ALTERATION TO THE BUILDING <br />(PER 2022 CAL GREEN SECTIONS 301.1.1, 4.303.1.1 -4.303.1.4.4 & 2022 CPC <br />SECTIONS 403.0 -403.8) <br />AIRPORT NOISE IMPACT ZONE: NO <br />ALL COMMON CORRIDORS, PUBLIC ROOMS AND ALL BED ROOMS REQUIRE <br />SMOKE DETECTORS. <br /> <br />●PROVIDE SMOKE AND CARBON MONOXIDE REQUIREMENT IN <br />RESIDENTIAL <br />THE ADU SF / SFD SF RATIO IS FOR PARK & REC FEE PURPOSE ONLY. THE <br />APPLICANT IS RESPONSIBLE FOR THE GIVEN “SFR SF”OF THE EXISTING <br />PRIMARY RESIDENCE; BUILDING SAFETY STAFF ARE NOT RESPONSIBLE FOR <br />THE ACCURACY OF THE GIVEN “SFR SF”OF THE EXISTING RESIDENCE. <br />PROJECT DESCRIPTION <br />CONVERSION OF 414 SF (E) GARAGE AND 120 SF UNPERMITTED (E) <br />GARAGE INTO ADDITIONAL DWELLING UNIT (ADU), WITH (N) <br />ADDITION OF 66SF AT THE BACK. <br />SI <br />D <br />E <br /> <br />S <br />E <br />T <br />B <br />A <br />C <br />K <br />4' <br /> <br />- <br /> <br />0 <br />" <br />OA <br />K <br /> <br />S <br />T <br />51 <br />' <br /> <br />- <br /> <br />0 <br />" <br />124' - 6" <br />SI <br />D <br />E <br /> <br />S <br />E <br />T <br />B <br />A <br />C <br />K <br />4' <br /> <br />- <br /> <br />0 <br />" <br />REAR SETBACK <br />4' - 0" <br />PL <br />PL <br />PLPL <br />(E) RESIDENCE TO REMAIN <br />46' - 0" <br />13 <br />' <br /> <br />- <br /> <br />3 <br />" <br />414 SF <br />(N) ADU ADDTION <br />66 SF <br />(E) OUTDOOR <br />CANOPY TO <br />DEMOLISH <br />5' <br /> <br />- <br /> <br />4 <br />" <br />5' - 0" <br />(E) GARAGE TO DEMO <br />AND CONVERT TO (N) ADU <br />41' - 0" <br />(E) UNPERMITTED <br />PORTION TO <br />DEMO AND <br />CONVERT <br />120 SF <br />(E) LANDSCAPE <br />(N) 1 HOUR RATED WALLS AND EAVES <br />ALL AROUND, SEE 1/A4.0 <br />(N) WATER METER <br />(N) GAS METER <br />(N) 125 A ELECTRICAL PANEL <br />(E) CANOPY ROOF TO REMOVE <br />4" SEWER LATERAL <br />4" SEWER LATERAL <br />CONNECTION TO MAIN HOUSE SEWER <br />LATERAL, VERIFY LOCATION ON SITE <br />The ideas and designs represented herein and this drawing, all <br />prepared by BKW STUDIO, are for the use solely with respect to <br />this project and BKW STUDIO shall retain all common law, <br />statutory and other reserved rights including copyright and they <br />shall not be used by others for any other purpose without written <br />permission of BKW STUDIO. <br />client approval <br />principal in charge <br />issues / revisions <br />drawing title <br />scale <br />project number <br />date <br />Plot Date: <br />File Path:If this sheet is smaller than 24" high by 36" wide then it has been reduced. <br />A B C D E <br />1 <br />2 <br />3 <br />Project Address <br />T 714.305.8928 <br />Copyright @ 2026 <br />13733 FRANCISCO DR <br />LA MIRADA, CA. 90638 <br />626.272.8479 <br />binhkwong@yahoo.com <br />BKW STUDIO <br />3/25/2026 4:19:37 PM <br />As indicated <br />03-24-2026 <br />TBD <br />2060 S OAK ST <br />SANTA ANA, CA 92707 <br />Project Status <br />A0.1 <br />GENERAL NOTES, <br />PROJECT DATA, SITE <br />PLAN AND SHEET <br />INDEX <br />GARCIA RESIDENCE <br />ADU CONVERSION <br />MARIA GARCIA <br />2060 S OAK ST <br />SANTA ANA, CA 92707 <br />SHEET INDEX <br />ARCHITECTURAL <br />A0.0 COVER <br />A0.1 GENERAL NOTES, PROJECT DATA, SITE PLAN AND SHEET INDEX <br />A1.2 ROOF PLAN - EXISTING / DEMOLITION AND FLOOR PLAN - NEW <br />A1.3 REFLECTED CEILING PLAN, DOOR & WINDOW TYPES, AND DOOR & <br />WINDOW SCHEDULES <br />A2.1 ROOF PLAN NEW <br />A3.0 EXTERIOR ELEVATIONS <br />A3.1 BUILDING SECTIONS <br />A4.0 WALL SECTIONS & DETAILS <br />A5.0 SPECIFICATIONS <br />A5.1 SPECIFICATIONS <br />STRUCTURAL <br />S0.1 STRUCTURAL NOTES <br />S0.2 STRUCTURAL NOTES <br />S1.1 TYPICAL DETAILS <br />S1.2 TYPICAL DETAILS <br />S1.3 TYPICAL DETAILS <br />S2.1 FOUNDATION AND ROOF FRAMING PLAN <br />S3.1 DETAILS <br />MECHANICAL <br />T1.1 TITLE 24 <br />T1.2 TITLE 24 <br />PLUMBING <br />P1.0 PLUMBING ENLARGED PARTIAL PLANS <br />ELECTRICAL <br />E-1 SCOPE OF WORK, GENERAL NOTES, GENERAL REQUIREMENTS <br />E-2 POWER PLAN <br />E-3 LIGHTING PLAN <br />E-4 PANEL SCHEDULE, LOAD CALCULATION, SINGLE LINE DIAGRAM <br />N <br />N <br />3/32" = 1'-0"1SITE PLAN - NEW <br />DEFERRED SUBMITTALS <br />3 <br />1 02/18/2026 PERMIT <br />CORRECTION <br />2 03/09/2026 PERMIT <br />CORRECTION 2 <br />3 03/24/2026 PERMIT <br />CORRECTION 3