Template:
Plan
Permit Number
101126038
Full Address
2060 S Oak St
Street Number
2060
Street Direction
S
Street Name
Oak
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CEILING LEGEND <br />DOWNLIGHT <br />BATHROOM EXHAUST FAN MIN 50 CFM <br />WITH HUMIDITY CONTROLLER PER R303.3 <br />(N) EXTERIOR PLASTER WALLS TO MATCH <br />EXISITNG <br />(N) INTERIOR GYPSUM BOARD WALLS <br />WALL SCONCE <br />WALL MOUNTED FAN COIL UNIT <br />CEILING MOUNTED CASSETTE FAN COIL UNIT <br />CHANDELIER TO BE SELECTED BY OWNER <br />CEILING MOUNT SMOKE DETECTOR <br />CEILING MOUNT CARBON DIOXIDE DETECTOR <br />(N) 1-HR RATED SEPARATION WALL <br />EXTERIOR PLASTER WALL <br />CONTINUOUS LED COVE LIGHT <br />SC SMOKE AND CARBON MONOXIDE ALARMS, <br />MIN 3' FROM BATHROOM DOORS <br />GENERAL CONSTRUCTION NOTES <br />1.CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING FIRE EGRESS DURING ALL PHASES OF DEMOLITION AND <br /> CONSTRUCTION. <br />2.VERIFY WITH OWNER PRIOR TO DISPOSAL OR REUSE OF ANY DEMOLISHED / REMOVED ITEMS. <br />3.NOTIFY ARCHITECT OF ANY UNCOVERED CONFLICTS DURING DEMOLITION, WHICH MAY ALTER OR MODIFY THE DESIGN <br /> INTENT. PRIOR TO MAKING ADJUSTMENT, THE ARCHITECT OR THE OWNER'S REPRESENTATIVE WILL ISSUE A DIRECTIVE TO <br /> PROCEED WITH THE MODIFICATIONS. <br />4.ALL (N) EXTERIOR STUD WALLS SHALL PROVIDE WEEP SCREED AT OR BELOW THE FOUNDATION PLATE LINE. THE SCREED <br /> SHALL BE PLACED A MINIMUM OF 4 INCHES ABOVE GRADE AND SHALL BE OF A TYPE WHICH WILL ALLOW TRAPPED WATER, TO <br /> DRAIN TO THE EXTERIOR OF THE BUILDING <br />5.ROOF COVERING FOR NEW CONSTRUCTION SHALL BE A CLASS A ROOF ASSEMBLY. (R902.1 AMENDED CRC) <br />6.BATHTUB AND SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH SHOWERS AND SHOWER COMPARTMENTS SHALL BE <br /> FINISHED WITH A NONABSORBENT SURFACE TO A HEIGHT OF 6FT ABOVE THE FLOOR. (R307.2 CRC) <br />7.PER (R314.4, R314.5, R314.6 CRC) <br />A. SMOKE ALARM SHALL BE TESTED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. <br />SMOKE ALARMS THAT NO LONGER FUNCTION SHALL BE REPLACED. <br />B. SMOKE ALARM SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL <br />ACTIVATE ALL ALARMS. <br />C. COMBINATION SMOKE AND CARBON MONOXIDE ALARMS SHALL BE PERMITTED TO BE USED IN LIEU OF SMOKE ALARMS. <br />D. SMOKE ALARM SHALL RECEIVE THEIR PRIMARY POWER FROM BUILDING WIRING AND BE EQUIPPED WITH A BATTERY <br /> BACKUP. <br />8.PER (R315.4, R315.5 & R315.7) <br />A. COMBINATION SMOKE AND CARBON MONOXIDE ALARMS SHALL BE PERMITTED TO BE USED IN LIEU OF CARBON <br />MONOXIDE ALARMS. <br />B. CARBON MONOXIDE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM BUILDING WIRING AND BE EQUIPPED <br />WITH A BATTERY BACKUP. <br />C. CARBON MONOXIDE ALARMS SHALL BE INTERCONNECTED IN A MANNER THAT ACTIVATION OF ONE ALARM SHALL <br />ACTIVATE ALL OF THE ALARMS. <br />9.MECHANICAL, ELECTRICAL, PLUMBING PLANS TO BE FIELD INSPECTION AND VERIFIED FOR CODE COMPLIANCE. <br />DOOR TYPES <br />WINDOW TYPES <br />A B C <br />W1 <br />T T <br />T T <br />NOTE: ALL WINDOW GLAZING TO BE T = TEMPERED <br />D <br />W2 W3 W4 <br />3' - 0"2' - 4" <br />7' <br /> <br />- <br /> <br />0 <br />" <br /> 2' - 6" <br />7' <br /> <br />- <br /> <br />0 <br />" <br />7' <br /> <br />- <br /> <br />0 <br />" <br /> 4" - 0" <br />7' <br /> <br />- <br /> <br />0 <br />" <br />3' <br /> <br />- <br /> <br />0 <br />" <br />T T 4' <br /> <br />- <br /> <br />0 <br />" <br />4' - 0"3' - 0" <br />4' <br /> <br />- <br /> <br />0 <br />" <br />5' - 0" <br />T T <br />1' <br /> <br />- <br /> <br />0 <br />" <br />3' - 0" <br />1 2 3 4 <br />C <br />B <br />A <br />A3.03 <br />A3.0 <br />1 <br />A3.0 4 <br />A3.0 <br />2 <br />(N) LIVING/KITCHEN <br />101 <br />(N) BEDROOM <br />103 <br />(N) BATHROOM <br />102 <br />9' - 0" <br />(N) STUCCO EAVE, TYP. <br />ADDITION <br />5' - 0" <br />EQ <br />EQ <br />4' <br /> <br />- <br /> <br />0 <br />" <br />EQ EQ <br />4' - 0"EQ <br />EQ <br />EQ <br />6' <br /> <br />- <br /> <br />0 <br />" <br />7' - 0"EQ EQ <br />EQ <br />5' - 0"EQ EQ 6' - 0"EQ EQ <br />6' <br /> <br />- <br /> <br />0 <br />" <br />EQ <br />EQ <br />2 <br />A3.1 <br />1 <br />A3.1 <br />9' - 0" <br />9' - 0" <br />EQ <br />EQ <br />EQ EQ <br />EQ <br />EQ <br />EQ EQ <br />SC SC <br />The ideas and designs represented herein and this drawing, all prepared by BKW <br />STUDIO, are for the use solely with respect to this project and BKW STUDIO <br />shall retain all common law, statutory and other reserved rights including <br />copyright and they shall not be used by others for any other purpose without <br />written permission of BKW STUDIO. <br />client approval <br />principal in charge <br />issues / revisions <br />drawing title <br />scale <br />project number <br />date <br />Plot Date: <br />File Path:If this sheet is smaller than 24" high by 36" wide then it has been reduced. <br />A B C D E <br />1 <br />2 <br />3 <br />Project Address <br />T 714.305.8928 <br />Copyright @ 2025 <br />13733 FRANCISCO DR <br />LA MIRADA, CA. 90638 <br />626.272.8479 <br />binhkwong@yahoo.com <br />BKW STUDIO <br />3/10/2026 12:44:41 PM <br />As indicated <br />03-09-2026 <br />TBD <br />2060 S OAK ST <br />SANTA ANA, CA 92707 <br />Project Status <br />A1.3 <br />REFLECTED CEILING PLAN, <br />DOOR & WINDOW TYPES, <br />AND DOOR & WINDOW <br />SCHEDULES <br />GARCIA RESIDENCE <br />ADU CONVERSION <br />MARIA GARCIA <br />2060 S OAK ST <br />SANTA ANA, CA 92707 <br />KEYNOTE <br />DOOR SCHEDULE <br />NO. <br />DOOR FRAME <br />REMARKSTYPE WIDTH HEIGHT GLASS MAT. FIN. <br />100.1 A 2' - 4" 7' - 0"NEW <br />101.1 B 3' - 0" 7' - 0"NEW <br />101.2 C 2' - 6" 7' - 0"NEW, LOUVERED DOOR LEAF, MIN 100 <br />SQUARE INCHES FOR MAKE UP AIR <br />102.1 A 2' - 4" 7' - 0"NEW <br />103.1 A 2' - 4" 7' - 0"NEW <br />103.2 D 4' - 0" 7' - 0"NEW <br />WINDOW SCHEDULE <br />NO. <br />WINDOW <br />U FACTOR SHGC <br />FRAME <br />REMARKSWIDTH HEIGHT MAT. FIN. GLASS MAT. FIN. <br />W1 4' - 0" 4' - 0" 0.3 0.23 (N) TEMPERED GLASS <br />W2 3' - 0" 3' - 0" 0.3 0.23 (N) TEMPERED GLASS <br />W3 5' - 0" 4' - 0" 0.3 0.23 (N) TEMPERED GLASS <br />W4 3' - 0" 1' - 0" 0.3 0.23 (N) TEMPERED GLASS <br />1/4" = 1'-0"1REFLECTED CEILING PLAN <br />NOTE: ALL (N) WINDOWS SHOULD HAVE MATCHING TRIMMINGS AND GRIDS AS THEY EXIST ON THE MAIN RESIDENCE. <br />2 <br />2 <br />1 02/18/2026 PERMIT CORRECTION <br />2 03/09/2026 PERMIT CORRECTION 2