Laserfiche WebLink
SM <br />S/C <br />WH <br />EL <br />E <br />C <br />T <br /> <br />M <br />E <br />T <br />E <br />R <br />ELECTRICAL LEGEND <br />LIGHT <br />SYMBOLS <br />EXHAUST FAN <br />GFCI OUTLET <br />AFCI DUPLEX <br />SWITCH <br />SMOKE / CARBON <br />DETECTORC/S <br />3 <br />A05 <br />1 <br />A05 <br />LOUVERED1 <br />VS <br />1 <br />1 <br />2 <br />4 <br />6 <br />7 <br />8 <br />9 <br />9 <br />5 <br />LOUVERED <br />1 <br />Scale <br />THESE PLANS ARE THE <br />PROPERTY OF MICHAEL'S <br />DRAFTING LLC. THEY ARE <br />PROVIDED AS A SERVICE AND <br />ARE PROTECTED BY <br />COPYRIGHT. ANY COPYING, <br />REPRODUCTION, OR <br />REDISTRIBUTION OF THESE <br />PLANS WITHOUT EXPLICIT <br />WRITTEN PERMISSION FROM <br />THE OWNER IS STRICTLY <br />PROHIBITED. <br />AS NOTED <br />Michael Barber <br />michaelsdrafting <br />(909) 486-3789 <br />Drafter / Designer <br />Rohit Grandhi <br />Grandhi Consults. <br />(908) 858-6325 <br />Structural Engineer <br />Oscar Bautista <br />T24 PRO <br />(626) 434-0930 <br />T24 Consultant <br />3/3/2026 <br />3/ <br />3 <br />/ <br />2 <br />0 <br />2 <br />6 <br /> <br />1 <br />: <br />1 <br />3 <br />: <br />0 <br />5 <br /> <br />P <br />M <br />A06 <br />ADU: 805 E <br />Clemensen <br />Ave Unit# 2 <br />ADU PROJECT <br />MEP Plan <br /> 1/4" = 1'-0" <br />MEP PLANS1 <br />MEP NOTES <br />1.160 CFM RANGE EXHAUST FAN TO BE INSTALLED OVER <br />ELECTRIC COOKTOP <br />2. 240V OUTLET FOR WH, DRYER AND COOKTOP. <br />3. 120V GFCI OUTLET PER CEC 210.52E, 210.8A, AND 406.9B <br />4. ALL BATHROOMS WITH A BATHTUB OR SHOWER SHALL BE <br />MECHANICALLY VENTILATED WITH MINIMUM 50 CFM <br />INTERMITTENT OR 20 CFM CONTINUOUS FANS. ALL FANS <br />SHALL BE HUMIDITY-CONTROLLED PER CALGREEN 4.506.1. <br />5. DISCONNECTS TO BE PROVIDED TO CONDENSOR UNITS PER <br />CEC 440.14 <br />6. BATHTUB AND SHOWER FLOORS AND WALLS ABOVE <br />BATHTUBS WITH INSTALLED SHOWER HEADS <br />AND IN SHOWER COMPARTMENTS SHALL BE FINISHED WITH A <br />NONABSORBENT SURFACE. SUCH WALL SURFACES <br />SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET <br />ABOVE THE FLOOR (CRC R307.2). <br />7. OPENING OF NOT LESS THAN 100 SQ. IN. FOR MAKEUP AIR <br />SHALL BE PROVIDED IN THE DOOR OR BY OTHER <br />APPROVED MEANS TO THE LAUNDRY ROOM (CMC 504.4.1 & <br />701.3). <br />8. IN BATHROOMS, LAUNDRY ROOMS, AND WALK-IN CLOSETS, <br />AT LEAST ONE INSTALLED LUMINAIRE SHALL BE <br />CONTROLLED BY AN OCCUPANCY OR VACANCY SENSOR <br />PROVIDING AUTOMATIC-OFF FUNCTIONALITY. (SECTION <br />150.0(K)2EI). <br />9. OUTDOOR LIGHTING (ABOVE LANDINGS AND ENTRY DOORS) <br />ATTACHED TO A BUILDING AND SEPARATELY <br />CONTROLLED FROM THE INSIDE OF A DWELLING UNIT SHALL <br />MEET THE REQUIREMENT IN ITEM I AND THE <br />REQUIREMENTS IN EITHER ITEM II OR ITEM III (SECTION <br />150.0(K)3A): <br />I. CONTROLLED BY A MANUAL ON AND OFF CONTROL <br />SWITCH THAT PERMITS THE AUTOMATIC ACTIONS OF <br />ITEM II OR III BELOW ; AND <br />II. CONTROLLED BY A PHOTOCELL AND EITHER A MOTION <br />SENSOR OR AN AUTOMATIC TIME SWITCH <br />CONTROL; OR <br />III. CONTROLLED BY AN ASTRONOMICAL TIME CLOCK <br />CONTROL. <br />CONTROLS THAT OVERRIDE TO ON SHALL NOT BE <br />ALLOWED UNLESS THE OVERRIDE AUTOMATICALLY <br />RETURNS THE <br />AUTOMATIC CONTROL TO ITS NORMAL OPERATION <br />WITHIN 6 HOURS. AN ENERGY MANAGEMENT CONTROL <br />SYSTEM THAT PROVIDES THE SPECIFIED LIGHTING <br />CONTROL FUNCTIONALITY AND COMPLIES WITH ALL <br />REQUIREMENTS APPLICABLE TO THE SPECIFIED <br />CONTROLS MAY BE USED TO MEET THESE <br />REQUIREMENTS. <br />1 <br />1 <br />No.Description Date <br />1 BLDG PC1 11/19/2025