My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
805 E Clemensen Ave & Unit #2 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Clemensen Ave
>
805 E Clemensen Ave Unit# 2
>
805 E Clemensen Ave & Unit #2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/29/2026 5:00:10 AM
Creation date
5/29/2026 5:00:04 AM
Metadata
Fields
Template:
Plan
Permit Number
101125421
Full Address
805 E Clemensen Ave Unit# 2
Street Number
805
Street Direction
E
Street Name
Clemensen
Street Suffix
Ave
Unit Number
2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Finished Floor <br />0' - 0" <br />Ceiling Height <br />8' - 0" <br />Roof Peak <br />14' - 6" <br />ADU <br />Finished Grade <br />-0' - 8"0' <br /> <br />- <br /> <br />7 <br /> <br />1 <br />/ <br />2 <br />" <br />LANDING <br />HEIGHT <br />Finished Floor <br />0' - 0" <br />Ceiling Height <br />8' - 0" <br />Roof Peak <br />14' - 6" <br />ADU Finished Grade <br />-0' - 8"0' <br /> <br />- <br /> <br />7 <br /> <br />1 <br />/ <br />2 <br />" <br />Finished Floor <br />0' - 0" <br />Ceiling Height <br />8' - 0" <br />Roof Peak <br />14' - 6" <br />ADU <br />WH ENCLOSURE <br />Finished Grade <br />-0' - 8"0' <br /> <br />- <br /> <br />7 <br /> <br />1 <br />/ <br />2 <br />" <br />LANDING <br />HEIGHT2 <br />ADU <br />WH ENCLOSURE <br />Finished Grade <br />-0' - 8"0' <br /> <br />- <br /> <br />7 <br /> <br />1 <br />/ <br />2 <br />" <br />LANDING <br />HEIGHT <br />Scale <br />THESE PLANS ARE THE <br />PROPERTY OF MICHAEL'S <br />DRAFTING LLC. THEY ARE <br />PROVIDED AS A SERVICE AND <br />ARE PROTECTED BY <br />COPYRIGHT. ANY COPYING, <br />REPRODUCTION, OR <br />REDISTRIBUTION OF THESE <br />PLANS WITHOUT EXPLICIT <br />WRITTEN PERMISSION FROM <br />THE OWNER IS STRICTLY <br />PROHIBITED. <br />AS NOTED <br />Michael Barber <br />michaelsdrafting <br />(909) 486-3789 <br />Drafter / Designer <br />Rohit Grandhi <br />Grandhi Consults. <br />(908) 858-6325 <br />Structural Engineer <br />Oscar Bautista <br />T24 PRO <br />(626) 434-0930 <br />T24 Consultant <br />3/3/2026 <br />3/ <br />3 <br />/ <br />2 <br />0 <br />2 <br />6 <br /> <br />1 <br />: <br />1 <br />3 <br />: <br />0 <br />6 <br /> <br />P <br />M <br />A07 <br />ADU: 805 E <br />Clemensen <br />Ave Unit# 2 <br />ADU PROJECT <br />ELEVATIONS <br /> 1/4" = 1'-0" <br />West Elevation3 <br /> 1/4" = 1'-0" <br />South Elevation1 <br /> 1/4" = 1'-0" <br />East Elevation2 <br /> 1/4" = 1'-0" <br />North Elevation4 <br />ELEVATION NOTES <br />NEW ADU EXTERIOR ELEVATIONS SHALL MATCH THE <br />ARCHITECTURAL STYLE, PROPORTIONS, MATERIALS, AND <br />FINISHES OF THE EXISTING PRIMARY RESIDENCE TO MAINTAIN <br />COHESIVE AESTHETICS AND NEIGHBORHOOD CHARACTER. <br />EXTERIOR WALL FINISH TO MATCH EXISTING RESIDENCE IN <br />TEXTURE, MATERIAL, AND COLOR (E.G., SMOOTH STUCCO, <br />SKIP TROWEL, BOARD AND BATTEN, OR HORIZONTAL LAP <br />SIDING). <br />FINISH COAT TO MATCH EXISTING COLOR USING <br />MANUFACTURER’S SPECIFICATION OR FIELD COLOR MATCH. <br />MATCH EXISTING WINDOW AND DOOR TRIM IN SIZE, PROFILE, <br />AND MATERIAL. <br />PROVIDE MATCHING FASCIA BOARDS, CORNER TRIM, AND <br />OTHER DECORATIVE ARCHITECTURAL ELEMENTS CONSISTENT <br />WITH THE EXISTING RESIDENCE. <br />ROOF OVERHANGS, EAVES, RAKE DETAIL, AND RIDGE LINE <br />HEIGHTS TO REFLECT PROPORTIONS OF THE EXISTING <br />RESIDENCE. <br />PROVIDE CONSISTENT EAVE DEPTH AND SOFFIT TREATMENT <br />(E.G., VENTED OR CLOSED SOFFITS). <br />FASCIA SIZE AND PROFILE TO MATCH EXISTING (E.G., 2X6 WITH <br />DRIP EDGE FLASHING). <br />WINDOW AND DOOR STYLES TO MATCH EXISTING IN <br />OPERATION TYPE, GRID PATTERN (IF ANY), AND FRAME <br />MATERIAL/COLOR. <br />MAINTAIN CONSISTENT HEAD HEIGHTS AND ALIGNMENT WITH <br />HORIZONTAL BANDS OF THE EXISTING STRUCTURE, WHERE <br />APPLICABLE. <br />NEW FENESTRATION TO MEET CURRENT TITLE 24 ENERGY <br />EFFICIENCY <br />ADU PLATE HEIGHTS AND RIDGE ELEVATIONS SHALL BE <br />PROPORTIONAL TO THE MAIN HOUSE AND WITHIN THE <br />ALLOWABLE HEIGHT LIMITS SET BY ORANGE COUNTY ZONING <br />CODE. <br />EXTERIOR LIGHT FIXTURES TO COMPLEMENT THOSE ON THE <br />EXISTING RESIDENCE. <br />No.Description Date <br />2 BLDG PC2 1/30/2026
The URL can be used to link to this page
Your browser does not support the video tag.