My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2041 E Wilshire Ave - Plan
PBA
>
Building
>
ProjectDox
>
W
>
Wilshire Ave
>
2041 E Wilshire Ave Unit# MTR01
>
2041 E Wilshire Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/29/2026 5:00:28 AM
Creation date
5/29/2026 5:00:04 AM
Metadata
Fields
Template:
Plan
Permit Number
20187645
20188666
20188667
20188668
101126103
101127467
101127468
101127469
Full Address
2041 E Wilshire Ave Unit# MTR01
2041 E Wilshire Ave Unit# MTR02
2041 E Wilshire Ave Unit# MTR03
2041 E Wilshire Ave Unit# MTR04
Street Number
2041
Street Direction
E
Street Name
Wilshire
Street Suffix
Ave
Unit Number
MTR04
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
540
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CITY OF SANTA ANA <br />NOTES <br />1. EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS <br />SUPPLYING POWER TO A BUS BAR OR CONDUCTOR <br />2. EQUIPMENT. INVERTERS, MOTOR GENERATORS, <br />PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AC <br />PHOTOVOLTAIC MODULES, SOURCE -CIRCUIT COMBINERS, AND <br />CHARGE CONTROLLERS INTENDED FOR USE IN PHOTOVOLTAIC <br />POWER SYSTEMS SHALL BE IDENTIFIED AND LISTED FOR THE <br />APPLICATION, (CEC 690.4(B)) <br />3. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, <br />INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND NON <br />ROOF SWITCHES. ROOF SWITCHES TO BE NEMA 4 RATED. <br />4. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND <br />BONDED IN ACCORDANCE WITH CEC ARTICLE 250. <br />5.PROTECTION DEVICES FOR PV SOURCE CIRCUITS AND PV <br />OUTPUT CIRCUITS ALSO CONNECTED TO SOURCES HAVING <br />SIGNIFICANTLY HIGHER CURRENT <br />AVAILABILITY (E.G., PARALLEL STRINGS OF <br />MODULES, UTILITY POWER), SHALL BE PROTECTED AT THE <br />SOURCE FROM OVERCURRENT. [CEC 690.9(A)] <br />6.PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL <br />INCLUDE A RAPID SHUTDOWN FUNCTION THAT CONTROLS <br />SPECIFIC CONDUCTORS. <br />[ CEC 690.121 <br />7.THE UTILITY INTERACTIVE INVERTERS SHALL AUTOMATICALLY <br />DE -ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL <br />PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF <br />VOLTAGE IN THE SYSTEM AND SHALL REMAIN IN THAT STATE <br />UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION <br />NETWORK VOLTAGE HAS BEEN RESTORED. <br />[CEC 705.411 <br />8.ALL CONDUCTOR EXPOSED TO WEATHER SHALL BE LISTED & <br />IDENTIFIED FOR USE IN DIRECT SUNLIGHT. [ CEC 310.10(D)(1)] <br />9.THE MODULE CONDUCTORS MUST BE TYPE USE-2 OR LISTED <br />FOR PHOTOVOLTAIC (PV) WIRE. (CEC 690.31(C)) <br />10.ALL CONDUCTORS SHALL BE MARKED ON EACH END FOR <br />UNIQUE IDENTIFICATION. <br />11.AN INSULATED GROUNDED CONDUCTOR OF 6 AWG OR <br />SMALLER SHALL BE IDENTIFIED AS A CONTINUOUS WHITE FINISH. <br />[CEC 200.61 <br />12.THE OUTPUT OF AN INTERCONNECTED ELECTRICAL POWER <br />SOURCE SHALL BE PERMITTED TO BE CONNECTED TO THE LOAD <br />SIDE. INTERCONNECTING <br />PROVISIONS FOR OTHER POWER SOURCES SHALL COMPLY WITH <br />705.12(B)(1) THROUGH 705.12(B)(5) <br />13. EACH SOURCE INTERCONNECTION OF ONE OR MORE POWER <br />SOURCES INSTALLED IN ONE SYSTEM SHALL BE MADE AT A <br />DEDICATED CIRCUIT BREAKER OR FUSIBLE DISCONNECTING <br />MEANS [CEC 705.12(B)(1)] <br />14.THE SUM OF THE AMPERE RATING OF THE OVERCURRENT <br />DEVICES IN CIRCUITS SUPPLYING POWER TO THE BUSBAR OR <br />CONDUCTOR SHALL NOT EXCEED 120% OF THE RATING OF <br />BUSBAR OR CONDUCTOR.[CEC 705.12(B)(3)(2)] <br />15.A CONNECTION AT EITHER END, BUT NOT BOTH ENDS, OF A <br />CENTER -FED PANEL BOARD IN DWELLINGS SHALL BE PERMITTED <br />WHERE THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) <br />OUTPUT CIRCUIT CURRENT AND THE RATING OF THE <br />OVERCURRENT DEVICE PROTECTING THE BUSBAR DOES NOT <br />EXCEED 120 PERCENT OF THE CURRENT RATING OF THE <br />BUSBAR. [CEC 705.12(B)(3)(2)] <br />16.EQUIPMENT CONTAINING OVERCURRENT DEVICES IN <br />CIRCUITS SUPPLYING POWER TO A BUS BAR OR CONDUCTOR <br />SHALL BE MARKED TO INDICATE THE PRESENCE OF ALL <br />SOURCES. [ CEC 705.12(B)(3)] <br />17.CIRCUIT BREAKER, IF BACKFED, SHALL BE SUITABLE <br />FOR SUCH OPERATION. [ CEC 705.12(B)(4)] <br />18.TO MINIMIZE OVERHEATING OF THE BUSBAR IN <br />PANELBOARD, THE PANELBOARD MAIN CIRCUIT BREAKER <br />AND THE PV POWER SOURCE CIRCUIT BREAKER SHALL BE <br />PHYSICALLY LOCATED AT THE OPPOSITE END OF THE <br />BUSBAR. <br />19. ALL THE CEC REQUIRED WARNING SIGNS, MARKINGS, <br />AND LABELS SHALL BE POSTED ON EQUIPMENT AND <br />DISCONNECTS PRIOR TO ANY INSPECTIONS TO BE <br />PERFORMED BY THE BUILDING DEPARTMENT INSPECTOR. <br />20.WHERE PV SYSTEM DC CIRCUIT'S RUN INSIDE A <br />BUILDING, THEY SHALL BE CONTAINED IN METAL <br />RACEWAYS TYPE MC METAL CLAD CABLE OR METAL <br />ENCLOSURES FROM POINT OF PENETRATION OF THE <br />SURFACE OF THE BUILDING TO THE FIRST READILY <br />ACCESSIBLE DISCONNECTING MEANS. [ CEC 690.31(G)] <br />21.FLEXIBLE, FINE -STRANDED CABLES SHALL BE <br />TERMINATED ONLY WITH TERMINALS, LUGS, DEVICES OR <br />CONNECTOR THAT ARE IS IN ACCORDANCE WITH <br />CEC 110.14 <br />22.CONNECTORS SHALL BE OF LATCHING OR LOCKING <br />TYPE. CONNECTORS THAT ARE READILY <br />ACCESSIBLE AND OPERATING AT OVER 30V DC OR 15V AC <br />SHALL REQUIRE TOOL TO OPEN AND MARKED "DO NOT <br />DISCONNECT UNDER LOAD" OR "NOT <br />FOR CURRENT INTERRUPTING". [CEC 690.33(C) & (E)(2)] <br />23. EQUIPMENT GROUNDING CONDUCTOR FOR PV <br />MODULES SMALLER THAN 6AWG SHALL BE PROTECTED <br />FROM PHYSICAL DAMAGE BY A RACEWAY OR CABLE <br />ARMOR. [CEC 690.46 & 250.120(C)] <br />24. AN EQUIPMENT GROUNDING CONDUCTOR SHALL NOT <br />BE SMALLER THAN 14 AWG. [ CEC 690.45] <br />25. FINE STRANDED CABLES USED FOR BATTERY <br />TERMINALS, DEVICES, AND CONNECTIONS REQUIRE LUGS <br />AND TERMINALS IS IN ACCORDANCE WITH CEC 110.14 <br />26.GROUNDING ELECTRODE CONDUCTOR(S) SHALL BE <br />INSTALLED IN ONE CONTINUOUS LENGTH WITHOUT A <br />SPLICE OR JOINT. IF NECESSARY,SPLICES OR <br />CONNECTIONS SHALL BE MADE AS PERMITTED. <br />(CEC 250.64 C) <br />27.ALL SMOKE ALARMS, CARBON MONOXIDE ALARMS AND <br />AUDIBLE NOTIFICATION DEVICES SHALL BE LISTED AND <br />LABELED IN ACCORDANCE WITH UL 217 AND UL 2034. <br />THEY WILL BE INSTALLED IN ACCORDANCE WITH NFPA 72 <br />AND NFPA 720. <br />28.SMOKE ALARMS AND CARBON MONOXIDE ALARMS WILL <br />BE RETROFITTED INTO THE EXISTING DWELLING. THESE <br />SMOKE ALARMS ARE REQUIRED TO BE IN ALL <br />BEDROOMS,OUTSIDE EACH BEDROOM, AND AT LEAST <br />ONE ON EACH FLOOR OF THE HOUSE CARBON MONOXIDE <br />ALARMS ARE REQUIRED TO BE RETROFITTED OUTSIDE <br />EACH BEDROOM AND AT LEAST ONE ON EACH FLOOR OF <br />THE HOUSE.THESE ALARMS MAY BE SOLELY BATTERY <br />OPERATED IF THE PHOTOVOLTAIC PROJECT DOES NOT <br />INVOLVE THE REMOVAL OF INTERIOR WALL AND <br />CEILING FINISHES INSIDE THE HOME, OTHERWISE, THE <br />ALARMS MUST BE HARD WIRED AND INTERCONNECTED. <br />GENERAL CONDUCTOR INSULATION KEY <br />DC CONDUCTORS <br />POSITIVE(UNGROUNDED) <br />RED <br />NEGATIVE(UNGROUNDED) <br />BLACK <br />480/277V AC CONDUCTORS <br />PHASE L1 <br />BROWN <br />PHASE L2 <br />ORANGE <br />PHASE L3 <br />YELLOW <br />120/208V OR 240V AC CONDUCTORS <br />PHASE L1 BLACK <br />PHASE L2 RED (SEE NOTE) <br />PHASE L3 BLUE <br />NEUTRAL WHITE OR GREY <br />GROUND GREEN OR BARE Cu <br />NOTE:THREE PHASE HIGH LEG MUST BE IN ORANGE COLOR <br />PER NFPA 70. <br />GROUND FAULT PROTECTION <br />1. PHOTOVOLTAIC INVERTERS SHALL BE EQUIPPED WITH DC <br />GROUND FAULT PROTECTION. INVERTERS ARE ALSO EQUIPPED <br />WITH ANTI-ISLANDING CIRCUITRY. <br />DISCONNECTING MEANS <br />1. MEANS SHALL BE PROVIDED TO ISOLATE EACH SOURCE <br />CIRCUIT FROM THE SYSTEM. <br />2. WHERE A CIRCUIT GROUNDING CONNECTION IS NOT <br />DESIGNED TO BE AUTOMATICALLY INTERRUPTED AS PART OF THE <br />GROUND -FAULT PROTECTION, A SWITCH OR CIRCUIT BREAKER <br />USED AS A DISCONNECTING MEANS SHALL NOT HAVE A POLE ON <br />THE GROUNDED CONDUCTOR. <br />3. THE GROUNDED CONDUCTOR MAY HAVE A BOLTED OR <br />TERMINAL DISCONNECTING MEANS TO ALLOW MAINTENANCE OR <br />TROUBLESHOOTING BY QUALIFIED PERSONNEL. <br />4. EQUIPMENT SUCH AS PHOTOVOLTAIC SOURCE CIRCUITS, <br />OVER CURRENT DEVICES, AND BLOCKING DIODES SHALL BE <br />PERMITTED ON THE PHOTOVOLTAIC SIDE OF THE PHOTOVOLTAIC <br />DISCONNECTING MEANS. <br />5. MEANS SHALL BE PROVIDED TO DISCONNECT INVERTERS <br />FROM ALL UNGROUNDED CONDUCTORS OF ALL SOURCES. IF THE <br />EQUIPMENT IS ENERGIZED FROM MORE THAN ONE SOURCE, THE <br />DISCONNECTING MEANS SHALL BE GROUPED AND IDENTIFIED. <br />6. A SINGLE DISCONNECTING MEANS SHALL BE PERMITTED FOR <br />THE COMBINED OUTPUT OF ONE OR MORE INVERTERS IN A GRID <br />INTERACTIVE SYSTEM. <br />7. DISCONNECTING MEANS SHALL BE PROVIDED TO <br />DISCONNECT A FUSE FROM ALL SOURCES OF SUPPLY IF THE FUSE <br />IS ENERGIZED FROM BOTH DIRECTIONS AND IS ACCESSIBLE TO <br />OTHER THAN QUALIFIED PERSONS. SUCH A FUSE IN A <br />PHOTOVOLTAIC SOURCE CIRCUIT SHALL BE CAPABLE OF BEING <br />DISCONNECTED INDEPENDENTLY OF FUSES IN OTHER <br />PHOTOVOLTAIC SOURCE CIRCUITS. <br />rov <br />GRORENERMTA S <br />PENN C W A B L C S- <br />,ESIGN SEPVICES <br />GREENTECH <br />REMWABLES <br />d eoNTRACTOR <br />weenconveroence <br />GREEN CONVERGENCE <br />28476 WESTINGHOUSE PL. <br />VALENCIA, CA 91355, USA <br />PHONE NO: (661) 294-9999 <br />CA LICENSE: #927678 <br />(B, C-10, & C-39) <br />Li <br />U Y o <br />w O LL <br />o Z <br />a U = Q <br />w w J U Q <br />Qco <br />U w Q Lu Q <br />w U H <br />o Z) o <br />IL w N Q <br />LL U) <br />a q <br />w o; <br />wa <br />o� <br />z� <br />W <br />� <br />o <br />Q <br />❑ <br />s <br />_ <br />o <br />� <br />s <br />A <br />z <br />O <br />z <br />o <br />z <br />a <br />a <br />z <br />o <br />w <br />w <br />1 <br />a <br />0 <br />12 <br />u) <br />a <br />F <br />> <br />> <br />> <br />WU) <br />ui o <br />a <br />= <br />a <br />O <br />} <br />a <br />_ <br />a <br />w <br />0 <br />0 <br />co <br />R <br />U <br />R <br />❑ <br />SHEET TITLE <br />NOTES <br />DRAWN DATE 04/02/2026 <br />DRAWN BY <br />PS <br />REVIEWED BY JVK <br />SHEET NUMBER <br />G-001 <br />Agency) <br />ANCE <br />