My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3313 S Bristol St - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Bristol St
>
3313 S Bristol St
>
3313 S Bristol St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2026 5:00:15 AM
Creation date
5/30/2026 5:00:05 AM
Metadata
Fields
Template:
Plan
Permit Number
20187042
30149389
40140820
101125250
Full Address
3313 S Bristol St
Street Number
3313
Street Direction
S
Street Name
Bristol
Street Suffix
St
Rectangle
ID:
1
Creator:
Import Agent
Created:
5/30/2026 5:00 AM
Modified:
5/29/2026 8:54 AM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
WATER PRESSURE IS SHOWN AS DIAGRAMMATIC ONLY. CONTRACTOR SHALL VERIFY <br />EXISTING WATER PRESSURE IN FIELD PRIOR TO ANY WORK AND PIPING ROUGH IN. IF <br />DISCOVERED ON SITE THAT EXISTING WATER PRESSURE IS LESS THAN 68 PSI, CONTACT <br />ENGINEER IMMEDIATELY FOR PIPING DESIGN CHANGES. IF PRESSURE IS GREATER THAN 80 <br />PSI PROVIDE PRESSURE REDUCING VALVE AND REDUCE DOWN TO 77 PSI. <br />PRIOR TO WORK VERIFY INCOMING WATER QUALITY TO SPACE. WHEN INCOMING WATER IS <br />ABOVE 3.5 GRAINS PER GALLON (60 PARTS PER MILLION) SCALE BUILD-UP WILL FORM INSIDE <br />THE PLUMBING SYSTEM CAUSING DAMAGE TO SYSTEM COMPONENTS AND COPPER PIPE. <br />TO AVOID DAMAGE DUE TO SCALE BUILD-UP, EITHER A WATER SOFTENER OR ANTI-SCALE <br />DEVICE SHOULD BE INSTALLED AT POINT-OF-ENTRY. APPLICATIONS WHERE THERE IS A <br />CONCERN FOR WATER SPOTS ON GLASS SHOWER DOORS, GLASS DISHES, VEHICLES IN <br />CARWASHES, ETC., AND/OR THE EFFECTS OF HARD WATER ON HUMAN SKIN, A WATER <br />SOFTENER SHOULD BE USED INSTEAD OF AN ANTI-SCALE DEVICE. ANTI-SCALE DEVICES <br />REDUCE THE FORMATION OF SCALE IN A PLUMBING SYSTEM BUT DO NOT REMOVE THE <br />CALCIUM AND MAGNESIUM FROM THE WATER, WHICH WILL REMAIN ONCE THE WATER HAS <br />EVAPORATE LEAVING WATER SPOTS AND/OR DRYING OUT HUMAN SKIN. WATER <br />SOFTENERS REMOVE CALCIUM AND MAGNESIUM FROM THE WATER BUT REQUIRE ROUTINE <br />REFILLING OF SALT LEVELS IN THE BRINE TANK. <br />EXISTING WATER SERVICE CONDITIONS NOTE: <br /> NOTE: <br />INSTALL 1" BACKFLOW PREVENTION <br />DEVICE FOR DOMESTIC PURPOSES <br />PER STANDARD PLAN NO. 1432 <br />OVEN <br />RACK <br />CE <br />L <br />L <br />O <br />CE <br />L <br />L <br />O <br />OVEN <br />RACK <br />OVEN <br />RACK <br />OVEN <br />RACK <br />OVEN <br />RACK <br />MI <br />C <br />R <br />O <br />RE <br />F <br />CWS CWS CWS <br />RPZBFP <br />PLUMBING SITE PLAN PLAN1 <br />P-100.1 SCALE: 1/4" = 1'-0" <br />(EX)1" WATER METER DEDICATED TO NBC <br />(EX) WATER MAIN <br />M <br />DOMESTIC COLD WATER SERVICE SHOWN IS BASED ON BEST AVAILABLE <br />INFORMATION AND IS AN APPROXIMATE LOCATION. CONTRACTOR SHALL <br />FIELD VERIFY THE EXACT LOCATION OF THE EXISTING WATER METER AND <br />SERVICE MAIN PRIOR TO ANY WORK. CONTRACTOR SHALL MAKE ALL <br />NECESSARY CONNECTIONS TO THE EXISTING SYSTEM AND PERFORM WORK <br />IN ACCORDANCE WITH ALL APPLICABLE AHJ AND UTILITY REQUIREMENT <br />IF BUILDING DOMESTIC WATER SERVICE IS NOT ALREADY PROTECTED BY A <br />MAIN BACKFLOW PREVENTER, THEN TENANT AND OR LANDLORD SHALL <br />PROVIDE A 1" REDUCED PRESSURE BACKFLOW PREVENTER (RPZ) AT AN <br />ACCESSIBLE LOCATION ABOVE THE MOP SINK. RELIEF VALVE SHALL DRAIN <br />INDIRECTLY INTO THE MOP SINK WITH A CODE-APPROVED AIR GAP. VERIFY <br />IN FIELD PRIOR TO EQUIPMENT PURCHASE. <br />PLEASE SEE CONTUNATION OF INTERNAL PIPING ON P-100 <br />1 <br />PLUMBING SUPPLY KEYED NOTES <br />1 <br />2 <br />2 <br />1"1"(EX)1" <br />3 <br />3 <br />5 <br />BACK FLOW PREVENTER ASSEMBLY REQUIREMENTS <br />TYPE OF EQUIP. <br />ON SYSTEM <br />METHOD OF CROSS CONNECTION <br />CONTROL <br />MANUFACTURE AND <br />MODEL NUMBER REMARKS <br />1. CONTRACTOR SHALL PROVIDE INDIVIDUAL BACKFLOW PREVENTERS FOR EACH PIECE OF EQUIPMENT. <br />2. EACH BACKFLOW PREVENTER MUST HAVE TESTING PORTS. <br />3. BRONZE BODIED BACKFLOW PREVENTERS ARE PERMISSABLE IF ALLOWED BY LOCAL CODES. <br />WATER SERVICE REDUCED PRESSURE ZONE <br />ASSEMBLY WATTS LF-009-QT-S <br />STAINLESS STEEL BODY WITH <br />QUARTER TURN VALVE BRONZE <br />STRAINER. <br />5 <br />P-100.1 <br />PLUMBING SITE PLAN <br />79 <br />6 <br /> <br />M <br />e <br />r <br />u <br />s <br /> <br />C <br />o <br />u <br />r <br />t <br />St <br />. <br /> <br />L <br />o <br />u <br />i <br />s <br />, <br /> <br />M <br />O <br /> <br />6 <br />3 <br />0 <br />2 <br />6 <br />T <br />6 <br />3 <br />6 <br />. <br />3 <br />4 <br />9 <br />. <br />1 <br />6 <br />0 <br />0 <br />F <br />6 <br />3 <br />6 <br />. <br />3 <br />4 <br />9 <br />. <br />1 <br />7 <br />3 <br />0 <br />16842136571210911141315 <br />84213657 1210911 1413 15 16 <br />a <br />b <br />c <br />d <br />e <br />f <br />g <br />h <br />j <br />k <br />l <br />m <br />n <br />p <br />r <br />s <br />a <br />b <br />c <br />d <br />e <br />f <br />g <br />h <br />j <br />k <br />l <br />m <br />n <br />p <br />r <br />s <br />Checked by <br />Drawn by <br />Issue Date <br />Project # <br />Scale <br />Client Approval <br />TI <br /> <br />T <br />E <br />M <br />P <br />L <br />A <br />T <br />E <br /> <br />V <br />1 <br />. <br />0 <br />, <br />10 <br />- <br />1 <br />1 <br />- <br />2 <br />0 <br />1 <br />1 <br />SANTA ANA - SOUTH <br />(#0972) <br />3313 S. BRISTOL ST. <br />SANTA ANA, CA 92704 <br />AS INDICATED <br />07/09/2025 <br />69325-CA03 <br />ISSUED FOR <br />PERMIT <br />#Description Date <br />These drawings/specifications are the property of Oculus Inc. They are <br />furnished as contract documents only. The seal(s) and signature(s) apply <br />only to the document to which they are affixed, and expressly disclaim <br />any responsibility for all other plans, specifications, estimates, reports or <br />other documents or instruments relating to or intended to be used for any <br />part or parts of the architectural or engineering project. Additionally these <br />drawings and seal(s) shall in no way convey or imply any type of warranty <br />or certification relating to the performance of products and materials <br />beyond those provided by their respective manufacturer. <br />© 2025 Oculus Inc. <br />Matthew R. Case, Engineer <br />CA # M41121 <br />HEALTH COMMENTS 10-23-20251 <br />CITY COMMENTS 01-05-20262 <br />HEALTH COMMENTS 01-19-20263 <br />CITY COMMENTS 03-10-20264 <br />CITY COMMENTS 04-21-20265
The URL can be used to link to this page
Your browser does not support the video tag.