Laserfiche WebLink
A.F.F. <br />DEMO ACT <br />10' - 2"A.F.F. <br />DEMO ACT <br />9' - 11" <br />A.F.F. <br />DEMO ACT <br />9' - 11" <br />A.F.F. <br />DEMO ACT <br />9' - 11" <br />A.F.F. <br />DEMO ACT <br />9' - 11" <br />A.F.F. <br />DEMO ACT <br />9' - 11" <br />7 <br />8 <br />8 <br />8' - 6" <br />5' <br /> <br />- <br /> <br />5 <br />" <br />13' - 0" <br />12' - 8"87' - 5" <br />24 <br />' <br /> <br />- <br /> <br />2 <br />" <br />5' <br /> <br />- <br /> <br />1 <br />" <br />11' - 4"9' - 10"87' - 5" <br />5' <br /> <br />- <br /> <br />1 <br />0 <br />" <br />12 <br />' <br /> <br />- <br /> <br />5 <br />" <br />21' - 6" <br />7' <br /> <br />- <br /> <br />0 <br />" <br />5' <br /> <br />- <br /> <br />1 <br />" <br />1 <br />2 <br />3 <br />4 <br />5 <br />5 5 <br />3 <br />6 <br />4 <br />5 <br />1 <br />16842136571210911141315 <br />84213657 1210911 1413 15 16 <br />a <br />b <br />c <br />d <br />e <br />f <br />g <br />h <br />j <br />k <br />l <br />m <br />n <br />p <br />r <br />s <br />Checked by <br />These drawings/specifications are the property of Oculus Inc. They are <br />furnished as contract documents only. The seal(s) and signature(s) apply <br />only to the document to which they are affixed, and expressly disclaim any <br />responsibility for all other plans, specifications, estimates, reports or other <br />documents or instruments relating to or intended to be used for any part or <br />parts of the architectural or engineering project. Additionally these <br />drawings and seal(s) shall in no way convey or imply any type of warranty or <br />certification relating to the performance of products and materials beyond <br />those provided by their respective manufacturer. <br />© 2025 Oculus Inc. <br />Drawn by <br />Issue Date <br />Project # <br />Scale <br />Client Approval <br />1/4" = 1'-0" <br />3/ <br />1 <br />9 <br />/ <br />2 <br />0 <br />2 <br />6 <br /> <br />5 <br />: <br />2 <br />1 <br />: <br />3 <br />2 <br /> <br />P <br />M <br />MT <br />BJK <br />07/09/2025 <br />69325-CA03 <br />A-100 <br />DEMOLITION PLAN <br />ISSUED FOR PERMIT <br />33 <br />1 <br />3 <br /> <br />S <br />. <br /> <br />B <br />R <br />I <br />S <br />T <br />O <br />L <br /> <br />S <br />T <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />( <br /># <br />0 <br />9 <br />7 <br />2 <br />) <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />( <br /># <br />0 <br />9 <br />7 <br />2 <br />) <br />07/09/2025 <br />SHEET NOTES:KEYNOTES: <br />KEY # KEYNOTE TEXT <br />1 DEMO ALL FLOOR FINISHES. ENSURE NO RESIDUE REMAINS. PREPARE CONCRETE SLAB FOR <br />INSTALLATION OF EPOXY FLOORING, REFER TO FINISH PLAN FOR MORE INFORMATION. <br />2 EXISTING STOREFRONT GLAZING SYSTEM AND ENTRY DOORS TO REMAIN. VERIFY STOREFRONT GLAZING <br />IS FULLY TEMPERED ACCORDING TO THE SAFETY REQUIREMENTS OF APPLICABLE CODES. <br />3 DEMO NON-LOAD BEARING PARTITIONS AS INDICATED. PATCH & REPAIR EXISTING REMAINING <br />PARTITIONS DAMAGED BY DEMOLITIONS. PATCH & PREP TO RECEIVE NEW FINISHES AS SCHEDULED. <br />4 EXISTING DOOR AND FRAME TO BE DEMOLISHED. GC TO ENLARGE DOOR OPENIGN IN ORDER TO INSTALL <br />NEW 42" DOOR. <br />5 EXISTING PLUMBING FIXTURE TO BE DEMOLISHED, RELOCATED OR CAP PLUMBING LINES BELOW SLAB AS <br />REQUIRED. <br />6 REMOVE ALL EXISTING COUNTER TOPS AND ASSOCIATED CABINETS AND LEGS. PREP SLAB AS REQUIRED <br />FOR INSTALLATION OF NEW FINISH. <br />7 DEMO EXISTING CEILING TILE, CEILING GRID, LIGHTS AND HANGER WIRES THROUGHOUT SPACE. <br />DUCTWORK TO BE REWORKED AS REQUIRED FOR NEW STORE LAYOUT. SEE MECHANICAL DRAWINGS. <br />8 REMOVE EXISTING LIGHTING THROUGHOUT ENTIRE SPACE. GC TO RELOCATE POWER OR TERMINATE <br />POWER AT SOURCE AS REQUIRED BY CODE. <br />• COORDINATE DEMOLITION AND DEBRIS REMOVAL REQUIREMENTS w/OWNER. <br />• PREVIOUS IMPROVEMENTS, FIXTURES, AND BUSINESS SYSTEMS NOT TO BE USED SHALL BE <br />REMOVED. REMOVE EXISTING UTILITIES NOT BEING REUSED, BACK TO POINT-OF-CONNECTION <br />AND CAP AS REQUIRED. LEAVE REMAINING CONSTRUCTION IN A SAFE STATE. DO NOT ABANDON <br />ANY SYSTEMS OR PREVIOUS IMPROVEMENTS. <br />• THE GENERAL CONTRACTOR SHALL PROVIDE PROTECTION FOR SYSTEMS AND FINISHES DURING <br />DEMOLITION AND THROUGHOUT THE PHASES OF CONSTRUCTION. PROVIDE ADDITIONAL <br />PROTECTIVE MEASURES AS REQUIRED BY THE LOCAL MUNICIPALITY. <br />• STRUCTURAL MODIFICATIONS TO THE BUILDING OR BUILDING'S STRUCTURAL SYSTEMS (OF ANY <br />TYPE) REQUIRE APPROVAL FROM AN APPROVED STRUCTURAL ENGINEER. <br />• FINISHES, SYSTEMS, MATERIALS, ETC. WHICH ARE TO REMAIN MUST BE RESTORED TO A LIKE-NEW <br />CONDITION OR REPLACED. <br />• CONTRACTOR RESPONSIBLE FOR PATCHING ANY SURFACES DAMAGED OR ALTERED DURING <br />CONSTRUCTION TO MATCH EXISTING CONDITIONS. <br />• DEMOLISHED ITEMS SHALL BE THE PROPERTY OF THE OWNER. ITEMS NOT CLAIMED AND STORED <br />BY THE OWNER SHALL BE SAFELY DISCARDED. <br />• PROTECT FINISHES THAT ARE EXISTING TO REMAIN AND HAVE PROFESSIONALLY CLEANED UPON <br />COMPLETION OF CONSTRUCTION. <br />1/4" = 1'-0"J1 DEMOLITION REFLECTED CEILING PLAN <br />1/4" = 1'-0"S1 DEMOLITION FLOOR PLAN <br /># Description Date