Laserfiche WebLink
PT-4 <br />FRP <br />B-2 <br />A <br />F <br />H <br />A-302G10 G1 <br />R1 <br />R1060 <br />" <br />60 <br />" <br />19' - 6"16' - 0"51' - 1 1/4" <br />2" <br />2" <br />7' - 6"13' - 7 1/8" <br />109' - 4" <br />2' - 0" <br />14' - 1 1/8"7' - 1 3/4"26' - 0 1/8"6' - 4"26' - 9 5/8"7' - 0" <br />24 <br />' <br /> <br />- <br /> <br />2 <br />" <br /> <br />E <br />X <br />I <br />S <br />T <br />I <br />N <br />G <br /> <br />C <br />L <br />E <br />A <br />R <br />, <br /> <br />F <br />. <br />V <br />. <br />24 <br />' <br /> <br />- <br /> <br />9 <br />" <br /> <br />E <br />X <br />I <br />S <br />T <br />I <br />N <br />G <br /> <br />L <br />E <br />A <br />S <br />E <br /> <br />L <br />I <br />N <br />E <br />; <br /> <br />F <br />. <br />V <br />. <br />2' <br /> <br />- <br /> <br />7 <br />" <br />6' <br /> <br />- <br /> <br />7 <br /> <br />1 <br />/ <br />2 <br />" <br />8' <br /> <br />- <br /> <br />9 <br />" <br />33' - 0"9' - 3 7/8" <br />8' <br /> <br />- <br /> <br />8 <br />" <br />8' <br /> <br />- <br /> <br />8 <br />" <br />4' <br /> <br />- <br /> <br />5 <br /> <br />3 <br />/ <br />8 <br />" <br />14 <br />' <br /> <br />- <br /> <br />1 <br />1 <br />" <br />4' <br /> <br />- <br /> <br />9 <br /> <br />5 <br />/ <br />8 <br />" <br />2' <br /> <br />- <br /> <br />4 <br /> <br />7 <br />/ <br />8 <br />" <br />2' <br /> <br />- <br /> <br />5 <br /> <br />1 <br />/ <br />8 <br />" <br />2' - 11" <br />10 <br />' <br /> <br />- <br /> <br />2 <br />" <br />288 SF <br />CUSTOMER LOBBY <br />183 SF <br />SALES <br />345 SF <br />BAKING / FROSTING <br />563 SF <br />DRY STORAGE <br />289 SF <br />WALK-IN CHILLER <br />82 SF <br />WALK-IN COOLER <br />286 SF <br />CRAFT AREA <br />47 SF <br />RESTROOM <br />150 SF <br />UTILITY <br />124 SF <br />EMPLOYEE AREA <br />175 SF <br />OFFICE <br />109' - 4" EXISTING CLEAR, F.V. <br />110' - 4" EXISTING LEASE LINE; F.V. <br />01 <br />1 <br />2 <br />2 <br />03 <br />02 <br />A <br />BB1 <br />B1B <br />C <br />B <br />B <br />8' <br /> <br />- <br /> <br />1 <br />0 <br />" <br />6' <br /> <br />- <br /> <br />6 <br />" <br />A34 <br />555 <br />12 <br />' <br /> <br />- <br /> <br />5 <br />" <br />27' - 8" <br />3' - 4" <br />5 <br />5 <br />B <br />B <br />6 <br />24" x 132"24" x 60" <br />7 <br />8 <br />8 <br />9 <br />8' <br /> <br />- <br /> <br />8 <br />" <br />10 10 <br />A-104 <br />P1 <br />11 <br />04 <br />12 <br />13 <br />06 <br />07 <br />A-101 <br />D4 <br />5 4' - 7" <br />14 <br />A-303 <br />E1 <br />A-303 <br />E5 <br />L1E12 <br />A-303S11 <br />S1 <br />A-304 <br />F1 <br />A-303 <br />L9 <br />A-304 F11 <br />A-304 P13 <br />P1 <br />36' - 8" <br />5 <br />5 <br />15 <br />2 <br />9 6 <br />16 <br />F1 <br />F9 <br />A-401 <br />F9 <br />A-401 <br />F9 <br />A-401 <br />1' <br /> <br />- <br /> <br />2 <br />" <br />1' - 2" <br />PROVIDE 6" CONCRETE <br />CURB WITH CONTINUOUS <br />COVED BASE <br />S5 <br />G-102 <br />S5 <br />G-102 <br />S5 <br />G-102 <br />1 <br />1.INTERIOR DIMENSIONS ARE FROM FACE OF <br />GYP. BD. TO FACE OF GYP. BD. UNLESS NOTED <br />OTHERWISE. (U.N.O.) <br />2. WORK SHALL FULLY COMPLY WITH GOVERNING <br />CODES, ORDINANCES, RESTRICTIONS, AND <br />CALIFORNIA ELECTRIC CODE. TAKE NECESSARY <br />SAFETY MEASURES AND COMPLY WITH LOCAL <br />BUILDING DEPARTMENT REQUIREMENTS FOR <br />PUBLIC PROTECTION (BARRICADES, SIGNS, <br />DUST BARRIERS, ETC.) <br />3. A CERTIFICATE OF OCCUPANCY SHALL BE <br />REQUIRED PRIOR TO OCCUPANCY OF THE <br />BUILDING. <br />4.EXISTING FIRE EXTINGUISHER TYPES, SIZES, <br />AND LOCATIONS ARE TO BE VERIFIED WITH THE <br />LOCAL FIRE AUTHORITY. TYPE K FIRE <br />EXTINGUISHERS PROVIDED NEAR THE KITCHEN <br />EQUIPMENT AND IN THE PATH OF TRAVEL. <br />REFERENCE COVER SHEET FOR ADDITIONAL <br />NOTES. <br />6. FIELD MEASURE LOCATIONS IN WHICH NEW <br />CONSTRUCTION MEETS EXISTING CONDITIONS <br />TO ENSURE FINISHES ARE FLUSH WITH <br />ADJACENT TO REMAIN. <br />7. G.C. SHALL VERIFY ALL DIMENSIONS AND SHALL <br />NOTIFY ARCHITECT IMMEDIATELY OF ANY <br />DISCREPANCIES. <br />8. NO TOXIC OR COMBUSTIBLE MATERIALS WITH A <br />SMOKE DEVELOPMENT RATING OF GREATER <br />THAN 50 ARE PERMITTED WITHIN WALLS. ALL <br />WOOD BLOCKING USED SHALL BE FIRE <br />RETARDANT. <br />9. G.C. IS RESPONSIBLE FOR PROVIDING ALL <br />WOOD OR METAL BLOCKING REQUIRED FOR <br />WALL HUNG CABINETS, COUNTER TOPS, WALL <br />MOUNTED SHELVING, PLUMBING FIXTURES, <br />ETC. TO ENSURE ADEQUATE SUPPORT. <br />10. G.C. SHALL PROVIDE 5/8" WATER RESISTANT <br />"GREENBOARD" AT NON RATED WALLS WITHIN <br />WET AREAS. <br />11.ALL DOORS ARE 4" OFF ADJACENT WALL, <br />UNLESS NOTED OTHERWISE (U.N.O.) <br />12. G.C. TO VERIFY THAT ALL EXISTING TENANT <br />DEMISING WALLS ARE COMPLETE TO DECK AND <br />SEALED TO COMPLETE RATED ASSEMBLY AS <br />REQUIRED BY GOVERNING CODES. <br />1. G.C. TO PROVIDE 3/4" QUARTER ROUND AT ALL SALES AREA, WAINSCOT, BASE BOARD, AND POS <br />STATIONS. <br />2.NO FOOD PREP TAKES PLACE IN CRAFT AREA AND AREA DESIGNATED FOR MANAGER'S DESK. ALL <br />FOOD PREP TAKES PLACE IN BAKING / FROSTING AREA. CRAFTING AREA IS USED STRICTLY FOR <br />DECORATING CAKE BOXES AND PREPARING OTHER DECORATIONS. DECORATION OF CAKE ITSELF <br />TAKES PLACE IN FROSTING AREA. <br />1. PLUMBING MATERIAL AND INSTALLATIONS <br />SHALL BE IN ACCORDANCE WITH ALL <br />APPLICABLE CODES AND ORDINANCES. <br />2. REFERENCE PLUMBING DRAWINGS FOR <br />LOCATIONS AND SIZE OF ACCESS PANELS. <br />3.FIXTURES, ACCESSORIES, AND <br />MANEUVERING SHALL COMPLY WITH THE <br />CURRENT A.D.A., STATE OR LOCAL <br />REGULATIONS FOR MOUNTING HEIGHTS AND <br />CLEARANCES. <br />4. EMERGENCY LIGHTING PROVIDES THE <br />ILLUMINATION LEVEL PRESCRIBED BY CODE. <br />(SEE ELECTRICAL DRAWINGS FOR <br />ADDITIONAL INFORMATION) <br />5. REFERENCE FLOOR FINISH PLAN AND <br />MATERIAL SELECTIONS FOR FLOOR AND <br />WALL FINISHES. <br />6. HOT WATER AND DRAIN PIPES SHALL BE <br />INSULATED PER ADA REQUIREMENTS. <br />MINIMUM HOT WATER SUPPLY INSULATION <br />SHALL BE PREMOLDED FIBERGLASS PIPE <br />INSULATION WITH WHITE ALL SERVICE <br />JACKET. INSULATION THICKNESS SHALL BE <br />MIN. 1"; SEE PLUMBING DRAWINGS. <br />7. CONTRACTOR TO PROVIDE BLOCKING FOR <br />RESTROOM ACCESSORIES, (GRAB BARS <br />SHALL BE INSTALLED WITH CONCEALED <br />ANCHOR PLATES.) <br />8. MOUNT GRAB BARS AT 34 1/2" TO <br />CENTERLINE AFF. <br />9. ALL GWB. IN RESTROOMS TO BE WATER <br />RESISTANT. <br />10. REMOVE TRIM BEHIND MIRROR FOR A FLUSH <br />MOUNTING CONDITION. <br />A PAPER TOWEL DISPENSER <br />SURFACE MOUNTED, FORT HOWARD BRAND "VISTA" LEVER ROLL <br />TOWEL DISPENSER #DIS-58553, OR EQUAL <br />B TOILET PAPER HOLDER <br />SURFACE MOUNTED, FORT HOWARD BRAND MICRO TWIN TOILET <br />PAPER DISPENSER #DIS-52102, OR EQUAL <br />C GRAB BAR 36", 1-12" DIAMETER, 18 GA., TYPE 304 SS w/CONCEALED MOUNT, <br />SMOOTH #4 POLISHED SATIN FINISH. BOBRICK #B-6206 <br />D GRAB BAR 42", 1-12" DIAMETER, 18 GA., TYPE 304 SS w/CONCEALED MOUNT, <br />SMOOTH #4 POLISHED SATIN FINISH. BOBRICK #B-6206 <br />E (NOT USED) <br />F LIQUID SOAP DISPENSER WALL MOUNTED, BOBRICK #B-4112 CONTURA, 20 GA. STAINLESS <br />STEEL <br />G WATER CLOSET <br />BARRIER FREE, FLOOR MOUNTED, ADA COMPLIANT WATER <br />CLOSET; SEE PLUMBING FOR SPECIFICATION <br />H LAVATORY ADA COMPLIANT LAVATORY , SEE PLUMBING <br />DRAWINGS FOR SPECIFICATION <br />J MIRROR 24" x 36" FRAMED MIRROR, BOBRICK #B-165-2436 <br />EXISTING FULL-HEIGHT <br />WALL TO REMAIN <br />NEW FULL HEIGHT WALL <br />STOREFRONT GLAZING SYSTEM <br />COOLER / FREEZER WALL PANEL <br />EXISTING <br />DOOR <br />TO REMAIN <br />NEW <br />CONSTRUCTION <br />DOOR <br />PARTIAL HEIGHT WALL <br />WALL PARTITION TAGX <br />FOR WALL PARTITION INFORMATION REFER TO A-102. <br />REFER TO STRUCTURAL DRAWINGS FOR <br />STRUCTURAL CONNECTION DETAILS <br />B-2 <br />FRP <br />PT-4 <br />4' <br /> <br />- <br /> <br />4 <br />" <br />PT-4 <br />FRP <br />D <br />C <br />B <br />G <br />B-2 <br />PT-4 <br />FRP <br />B-2 <br />J <br />H <br />F <br />B <br />G <br />D <br />C <br />04 <br />47 SF <br />RESTROOM <br />4' <br /> <br />- <br /> <br />0 <br />" <br /> <br />C <br />L <br />E <br />A <br />R <br />5' - 0" CLEAR <br />5' <br /> <br />- <br /> <br />0 <br />" <br /> <br />C <br />L <br />E <br />A <br />R <br />1' <br /> <br />- <br /> <br />0 <br />" <br />3' - 0"6" <br />6' <br /> <br />- <br /> <br />3 <br /> <br />1 <br />/ <br />4 <br />" <br />7' - 6" <br />ø 5' - 7" MIN.CLEAR <br />H <br />A <br />F <br />G <br />C <br />J <br />D <br />B <br />A101 <br />D <br />C <br />A <br />B <br />1' - 6" <br />3' <br /> <br />- <br /> <br />7 <br /> <br />3 <br />/ <br />4 <br />" <br />2' - 6" CLEAR <br />1/4" = 1'-0"S1 FLOOR PLAN / FINISH PLAN <br />KEY # KEYNOTE TEXT <br />1 EXISTING STOREFRONT GLAZING SYSTEM AND ENTRY DOORS TO REMAIN. VERIFY STOREFRONT GLAZING <br />IS FULLY TEMPERED ACCORDING TO THE SAFETY REQUIREMENTS OF APPLICABLE CODES. <br />2 PROVIDE P.O.S. REGISTER COUNTERS - REFERENCE CASEWORK DETAILS. REFERENCE OBSTRUCTED <br />SIDE REACH ON G-102. <br />3 COUNTERS FURNISHED BY TENANT, INSTALLED BY G.C. OFFICE COUNTER TO BE MOUNTED TO WALL WITH <br />LEDGER AND METAL BRACKETS. PROVIDE BLOCKING AS REQUIRED. <br />4 DATA RACK PROVIDED BY OTHERS. <br />5 PROVIDE STAINLESS STEEL CORNER OR CAP GUARD THROUGHOUT KITCHEN. SET ABOVE BASE. APPLY <br />WITH CONSTRUCTION ADHESIVE AND SCREWS. (HALF PARTITIONS AT MOP SINK TO HAVE CAP GUARDS <br />TO 6'-8") <br />6 ALUMINUM WALL CLOSURE TRIM BETWEEN COOLER AND WALL. REFERENCE FINISH DETAILS SHEET <br />1-105. <br />7 PROVIDE CRAFTING COUNTER. REFERENCE CASEWORK DETAILS. <br />8 PROVIDE BLOCKING AT 24" CELLOPHANE CUTTER. REFER TO DETAIL S9/A-102. BOTTOM OF CELLOPHANE <br />CUTTER TO BE MOUNTED AT 3'-0" A.F.F. (LOADED UNIT APPROX. 150 LBS.) <br />9 EXISTING DEMISING WALLS TO REMAIN. <br />10 WALK-IN COOLER AND CHILLER DETAILS AND SPECIFICATIONS BY OTHERS UNDER SEPARATE SUBMITTAL. <br />11 PROVIDE ROOM SIGNAGE AT TOILET ROOM AND DOOR. REF. SHEET G-102. <br />12 EXISTING ELECTRICAL PANEL. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. <br />13 REFERENCE ENLARGED RESTROOM PLAN <br />14 CONFERENCE TABLE AND CHAIRS TO BE PROVIDED BY OWNER. <br />15 STRIP RESTROOM SIDE OF EXISTING WALL FINISH AND PROVIDE WATER RESISTANT GYP. BOARD. <br />16 PROVIDE TYPE X GWB BEHIND OVEN. <br />SHEET NOTES: <br />KEYNOTES: <br />16842136571210911141315 <br />84213657 1210911 1413 15 16 <br />a <br />b <br />c <br />d <br />e <br />f <br />g <br />h <br />j <br />k <br />l <br />m <br />n <br />p <br />r <br />s <br />Checked by <br />These drawings/specifications are the property of Oculus Inc. They are <br />furnished as contract documents only. The seal(s) and signature(s) apply <br />only to the document to which they are affixed, and expressly disclaim any <br />responsibility for all other plans, specifications, estimates, reports or other <br />documents or instruments relating to or intended to be used for any part or <br />parts of the architectural or engineering project. Additionally these <br />drawings and seal(s) shall in no way convey or imply any type of warranty or <br />certification relating to the performance of products and materials beyond <br />those provided by their respective manufacturer. <br />© 2025 Oculus Inc. <br />Drawn by <br />Issue Date <br />Project # <br />Scale <br />Client Approval <br />As indicated <br />3/ <br />1 <br />9 <br />/ <br />2 <br />0 <br />2 <br />6 <br /> <br />5 <br />: <br />2 <br />1 <br />: <br />3 <br />6 <br /> <br />P <br />M <br />MT <br />BJK <br />07/09/2025 <br />69325-CA03 <br />A-101 <br />FLOOR PLAN & <br />ENLARGED <br />RESTROOM PLAN <br />ISSUED FOR PERMIT <br />33 <br />1 <br />3 <br /> <br />S <br />. <br /> <br />B <br />R <br />I <br />S <br />T <br />O <br />L <br /> <br />S <br />T <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />( <br /># <br />0 <br />9 <br />7 <br />2 <br />) <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />( <br /># <br />0 <br />9 <br />7 <br />2 <br />) <br />07/09/2025 <br />GENERAL FLOOR PLAN NOTES: <br />GENERAL RESTROOM PLAN NOTES: <br />RESTROOM ACCESSORIES <br />PLAN LEGEND <br />1/2" = 1'-0"A RESTROOM ELEVATION A <br />1/2" = 1'-0"B RESTROOM ELEVATION B <br />1/2" = 1'-0"C RESTROOM ELEVATION C <br />1/2" = 1'-0"D RESTROOM ELEVATION D <br />SEE FIXTURE AND ACCESSORY <br />MOUNTING LEGEND OF G-102 <br />FOR DIMENSIONAL LOCATIONS <br />1/2" = 1'-0"D4 ENLARGED RESTROOM PLAN <br /># Description Date <br />1 HEALTH COMMENTS 09/23/2025 <br />3 CITY COMMENTS 02/09/2026 <br />3 <br />3 <br />3 <br />3