DN
<br />UP
<br />DN
<br />UP
<br />UP
<br />(E) WOMENS
<br />RESTROOM
<br />104OFFICE
<br />111
<br />OFFICE
<br />110
<br />(E) MENS
<br />RESTROOM
<br />103
<br />(E) OPEN
<br />OFFICE
<br />106
<br />(E)
<br />EXIT CORRIDOR
<br />-
<br />CAFE
<br />101
<br />BOH
<br />102
<br />LOBBY
<br />100
<br />STORAGE
<br />105
<br />DN
<br />UP
<br />DN
<br />UP
<br />UP
<br />(E) WOMENS
<br />RESTROOM
<br />104OFFICE
<br />111
<br />OFFICE
<br />110
<br />(E) MENS
<br />RESTROOM
<br />103
<br />(E) OPEN
<br />OFFICE
<br />106
<br />(E)
<br />EXIT CORRIDOR
<br />-
<br />CAFE
<br />101
<br />BOH
<br />102
<br />LOBBY
<br />100
<br />STORAGE
<br />105
<br />(E)
<br />(E)
<br />(E)
<br />(E)
<br />(E)
<br />(E)
<br />DN
<br />UP
<br />DN
<br />UP
<br />UP
<br />(E) WOMENS
<br />RESTROOM
<br />104OFFICE
<br />111
<br />OFFICE
<br />110
<br />(E) MENS
<br />RESTROOM
<br />103
<br />(E) OPEN
<br />OFFICE
<br />106
<br />(E)
<br />EXIT CORRIDOR
<br />-
<br />OPEN TO
<br />ABOVE
<br />(E)
<br />(E)
<br />F1
<br />F1
<br />F2F2
<br />F1 F1
<br />F3F4
<br />F3
<br />F3
<br />10
<br />13
<br />ID5.2 TYP.
<br />6'-6"3'-4"
<br />4'
<br />-
<br />1
<br />"
<br />4'
<br />-
<br />4
<br />"
<br />3'-4"
<br />2'-6"
<br />3'
<br />-
<br />2
<br />"
<br />2'-0"
<br />6'-3"
<br />3'-
<br />0
<br />"
<br />1'
<br />-
<br />6
<br />"
<br />2'-0"
<br />4'-10"
<br />1'
<br />-
<br />6
<br />"
<br />2'-
<br />1
<br />"
<br />4'-
<br />2
<br />"
<br />1'-6"
<br />7'-6"
<br />11
<br />11
<br />11
<br />11
<br />12
<br />12
<br />12
<br />1313
<br />13
<br />13
<br />1
<br />1
<br />DN
<br />UP
<br />DN
<br />UP
<br />UP
<br />(E) WOMENS
<br />RESTROOM
<br />104OFFICE
<br />111
<br />OFFICE
<br />110
<br />(E) MENS
<br />RESTROOM
<br />103
<br />(E) OPEN
<br />OFFICE
<br />106
<br />(E)
<br />EXIT CORRIDOR
<br />-
<br />CAFE
<br />101
<br />BOH
<br />102
<br />LOBBY
<br />100
<br />STORAGE
<br />105
<br />DN
<br />UP
<br />DN
<br />UP
<br />UP
<br />(E) WOMENS
<br />RESTROOM
<br />104OFFICE
<br />111
<br />OFFICE
<br />110
<br />(E) MENS
<br />RESTROOM
<br />103
<br />(E) OPEN
<br />OFFICE
<br />106
<br />(E)
<br />EXIT CORRIDOR
<br />-
<br />CAFE
<br />101
<br />BOH
<br />102
<br />LOBBY
<br />100
<br />STORAGE
<br />105
<br />DN
<br />UP
<br />DN
<br />UP
<br />UP
<br />(E) WOMENS
<br />RESTROOM
<br />104OFFICE
<br />111
<br />OFFICE
<br />110
<br />(E) MENS
<br />RESTROOM
<br />103
<br />(E) OPEN
<br />OFFICE
<br />106
<br />(E)
<br />EXIT CORRIDOR
<br />-
<br />7'-2"
<br />14
<br />'
<br />-
<br />1
<br />"
<br />3'-0"
<br />80°
<br />3'
<br />-
<br />0
<br />"
<br />7'
<br />-
<br />4
<br />"
<br />4'-0"100
<br />°
<br />11
<br />'
<br />-
<br />1
<br />1
<br />"
<br />3'-
<br />4
<br />"
<br />21
<br />'
<br />-
<br />5
<br />"
<br />3'
<br />-
<br />0
<br />"
<br />±2
<br />5
<br />'
<br />-
<br />0
<br />"
<br />1'-6"
<br />4'-8"
<br />4'-0"
<br />6'
<br />-
<br />7
<br />"
<br />6'-8"
<br />12
<br />'
<br />-
<br />1
<br />"
<br />R3'-
<br />0
<br />"
<br />5'
<br />-
<br />0
<br />"
<br />
<br />M
<br />I
<br />N
<br />.
<br />-
<br />ID4.0
<br />-
<br />ID4.0
<br />3C
<br />ID4.0
<br />3A
<br />ID4.0
<br />-
<br />ID4.0
<br />C1
<br />C1
<br />C1
<br />C2 C2
<br />C1
<br />C1
<br />
<br />S
<br />I
<br />M
<br />.
<br />1
<br />ID4.0
<br />2A
<br />ID4.0
<br />2B
<br />ID4.0
<br />3C
<br />ID4.0
<br />3B
<br />ID4.0
<br />5'
<br />-
<br />9
<br />"
<br />2'-8"
<br />1'
<br />-
<br />1
<br />"
<br />P
<br />2'
<br />-
<br />4
<br />"
<br />1'-6"
<br />2'-2"
<br />2'-6"
<br />2'-
<br />1
<br />1
<br />"
<br />C3
<br />C3
<br />2'-7"
<br />2'
<br />-
<br />7
<br />"
<br />4
<br />ID4.0
<br />C
<br />D
<br />A
<br />B
<br />-
<br />4
<br />ID4.0
<br />A
<br />D
<br />C
<br />B
<br />SIM.
<br />1
<br />1
<br />Sheet Title:
<br />ISSUE DATE
<br />ISSUE FOR PLANCHECK 12.22.2025
<br />All drawings and written material appearing herein constitute the original and
<br />unpublished work of MAD Studio and the same may not be duplicated, used
<br />or disclosed without the written consent of MAD Studio.
<br />Sheet No.:
<br />ISSUE DESCRIPTION
<br />ENGINEER/CONSULTANT
<br />ARCHITECT/ENGINEER STAMP
<br />30
<br />5
<br />
<br />W
<br />
<br />4
<br />T
<br />H
<br />
<br />S
<br />T
<br />R
<br />E
<br />E
<br />T
<br />,
<br />
<br />S
<br />A
<br />N
<br />T
<br />A
<br />
<br />A
<br />N
<br />A
<br />,
<br />
<br />C
<br />A
<br />
<br />9
<br />2
<br />7
<br />0
<br />1
<br />CA
<br />F
<br />E
<br />OA
<br />S
<br />I
<br />S
<br />CLIENT
<br />www.madstudiola.com
<br />CITY STAMP
<br />Project Director:
<br />Project Designer:
<br />Project Tech:
<br />Project No:25030.300E.M.
<br />E.M.
<br />S.P.
<br />ISSUED FOR MEP 01.13.2026
<br />ISSUED FOR PLAN CHECK COMMENTS- PLANNING DEPT.01.22.2026
<br />ISSUED FOR PRICING 02.17.2026
<br />ISSUED FOR PLAN CHECK COMMENTS - PLANNING DEPT.02.20.2026
<br />ISSUED FOR COUNTY REVIEW 03.24.2026
<br />ISSUED FOR ADDENDUM A 03.27.2026
<br />ISSUED FOR BUILDING DEPT REVIEW 04.08.2026
<br />ISSUED FOR BUILDING DEPT REVIEW - RESUBMITTAL 05.05.2026
<br />ISSUED FOR BUILDING DEPT CORRECTIONS 05.20.2026
<br />SHEET NOTES LEGEND
<br />SYMBOL DESCRIPTION DETAIL SYMBOL DESCRIPTION DETAIL 1.REFER TO SHEET ID0.1 FOR GENERAL PARTITION NOTES.
<br />2.ALL NEW PARTITIONS SHALL BE TYPE "B1", U.O.N.
<br />3.ALL WORK SHALL BE CONSTRUCTED TO FULLY COMPLY WITH LOCAL BUILDING CODES, INCLUDING
<br />BUILDING AND SAFETY, FIRE/LIFE SAFETY AND ADA REQUIREMENTS.
<br />4.REFER TO DETAIL 1/ID5.1 FOR TYPICAL CORNER AND JOINT DETAILS AT DRYWALL PARTITIONS
<br />5.REFER TO SHEETS ID3.0 FOR DOOR, HARDWARE SCHEDULE, FIXTURE SCHEDULE, AND EQUIPMENT SCHEDULE.
<br />6.PROVIDE SUPPORT BACKING AT ALL NEW AND EXISTING PARTITIONS THAT ARE TO RECEIVE NEW MILLWORK,
<br />WALL-MOUNTED TELEVISIONS, MONITORS AND/OR MARKER BOARDS, U.O.N. ON PLAN. REFER TO DETAIL
<br />3/ID6.0 FOR TYPICAL BRACING DETAIL.
<br />7.ALL DIMENSIONS ARE FROM FACE OF FINISH TO FACE OF FINISH, U.O.N.
<br />8.THE GENERAL CONTRACTOR SHALL VERIFY ALL ALIGNMENTS IN THE FIELD. IF MISALIGNMENT OF EXISTING
<br />ELEMENTS SHOULD OCCUR, THE GENERAL CONTRACTOR SHALL VERIFY THE OPTION OF FURRING
<br />PARTITION(S) AS NECESSARY TO PROVIDE THE REQUIRED ALIGNMENT.
<br />9.WHERE ALIGNMENTS BETWEEN TWO ELEMENTS ARE CRITICAL, TOLERANCE FOR SUCH ALIGNMENT SHALL
<br />NOT EXCEED 14" IN 10'-0".
<br />10.REPAIR/PREP ALL EXISTING PARTITIONS, DOORS FRAMES, ETC SCHEDULED TO RECEIVE A NEW FINISH.
<br />11.LEVEL OR "FLOAT" EXISTING FLOOR SLAB WHERE REQUIRED FOR LEVEL FINISH AND APPEARANCE.
<br />12.GENERAL CONTRACTOR TO VERIFY EXISTING WALL BASE HEIGHT AND SKIM WALL AS REQUIRED TO RECEIVE
<br />NEW WALL BASE.
<br />13.PROVIDE TACTILE EXIT SIGNS AS REQUIRED BY THE INSPECTOR.
<br />14.DOOR OPENINGS IN GYPSUM BOARD PARTITIONS NOT DIMENSIONED ARE TO BE LOCATED IN CENTER OF
<br />ROOM OR 4" FROM ADJOINING PARTITION, U.O.N.
<br />15.UNLESS OTHERWISE NOTED, CONTRACTOR SHALL PROVIDE 1/4" COPPER LINE AND ISOLATION VALVES AT ALL
<br />SINK LOCATIONS FOR COFFEE MAKERS AND REFRIGERATORS. MOUNT BELOW COUNTERTOP.
<br />16.FIRE EXTINGUISHER CABINETS (FEC) SHALL BE BUILDING STANDARD OR APPROVED EQUAL, U.O.N. (TYPICAL 6"
<br />STUD DEPTH, TO BE VERIFIED).
<br />17.LEVEL OR FLOAT FLOORS WHERE REQUIRED FOR LEVEL FINISH AND APPEARANCE, WHERE FURNITURE/MILLED
<br />UNITS AND ARCHITECTURAL ELEMENT ALIGNMENTS ARE CRITICAL (I.E. @ SLIDING DOORS, FILE ENCLOSURES,
<br />BASES AT FULL HEIGHT CLOSETS, ETC.) TOLERANCE TO BE NO MORE THAN 1/4" IN 10'-0".
<br />REFLECTED CEILING NOTES
<br />18.ALL CEILINGS SHALL BE +9'-0" A.F.F.
<br />19.REFER TO SHEET ID0.2 FOR GENERAL REFLECTED CEILING PLAN NOTES. REFER TO SHEET ID0.4 FOR GREEN
<br />BUILDING NOTES.
<br />20.ALL NEW SCHEDULED CEILING TYPE (E.G. A.C.T, GYP. BD.) TO BE INSTALLED AT +8'-9" TO MATCH EXISTING
<br />CEILING HEIGHTS, U.O.N.; VERIFY EXISTING CEILING HEIGHTS AND NOTIFY ARCHITECT OF ANY
<br />DISCREPANCIES PRIOR TO INSTALLATION.
<br />21.THE GENERAL CONTRACTOR SHALL OBTAIN EXACT LOCATIONS OF LIGHT FIXTURES AT OPEN OR HARD
<br />CEILING FROM MAD STUDIO AND/OR LIGHTING CONSULTANT PRIOR TO INSTALLATION.
<br />22.ALL LIGHT FIXTURES SHOWN ON PLAN ARE NEW, U.O.N. "(E)" INDICATES EXISTING FIXTURES TO REMAIN. "(R)"
<br />INDICATES EXISTING FIXTURES TO BE REINSTALLED AT THE LOCATION SHOWN ON PLAN(S).
<br />23.REFER TO ELECTRICAL ENGINEERING DRAWINGS FOR LIGHT SWITCH LOCATIONS, U.O.N.
<br />24.ALL LIGHT SWITCHES, PROJECTION SCREEN CONTROLS, AND THERMOSTATS SHALL BE GANGED TOGETHER
<br />WHERE POSSIBLE. REFER TO ENGINEERS DRAWINGS FOR LOCATION ON PLAN. REFER TO "OUTLET LOCATION
<br />HEIGHTS" SECTION ON SHEET ID3.0 FOR HEIGHT LOCATIONS.
<br />25.ALL CEILING SYSTEMS AND FIXTURES ARE TO BE SUPPORTED AND BRACED AS REQUIRED BY LOCAL
<br />GOVERNING CODES.
<br />26.AT CONDITIONS OF INTERFERENCE BETWEEN DUCTWORK AND LIGHT FIXTURE, PROVIDE NECESSARY
<br />MEASURES TO ACCOMMODATE FIXTURE.
<br />27.EXTEND OR MODIFY FIRE/LIFE SAFETY SYSTEM AS REQUIRED.
<br />28.WHERE LIGHT FIXTURES, SPRINKLER HEADS, FIRE/LIFE SAFETY DEVICES, ETC. THAT ARE TO BE INSTALLED IN AN
<br />ACOUSTICAL TILE CEILING, SUCH FIXTURES ARE TO BE INSTALLED IN THE CENTER OF THE CEILING TILE, U.O.N.
<br />29.ALL CEILING FIXTURES SHALL BE CENTERED IN CEILING TILES (EQUALLY IN BOTH DIRECTIONS), U.O.N. IF TWO
<br />OR MORE SPRINKLER HEADS OCCUR IN ONE ROOM, THEY SHALL BE ALIGNED WITH EACH OTHER. PROVIDE
<br />SEMI-RECESSED CHROME HEADS WITH WHITE ESCUTCHEONS AT SUSPENDED TILE CEILINGS AND
<br />CONCEALED TYPE HEADS AT DRYWALL CEILINGS, COLOR TO MATCH CEILING COLOR FINISH.
<br />30.ALL EXPOSED DATA/PHONE LINES SHALL BE IN CABLE TRAYS OR SHALL BE IN RIGID CONDUIT WHEN
<br />CROSSING OPEN CEILING AREAS.
<br />31.PROVIDE ACCESS PANELS WHERE REQUIRED, SPEC: WIND-LOCK STEALTH GFRG. VERIFY LOCATION AND SIZE
<br />WITH MAD PRIOR TO INSTALLATION.
<br />32.PROVIDE LINEAR DIFFUSERS IN DRYWALL CEILINGS WHERE SUPPLY/RETURN AIR IS REQUIRED, U.O.N. REFER TO
<br />MECHANICAL ENGINEERING DRAWINGS FOR HVAC REQUIREMENTS. VERIFY FINAL LOCATION OF DIFFUSERS
<br />WITH MAD PRIOR TO INSTALLATION.
<br />33.RE-USE EXISTING WINDOW TREATMENTS, CLEAN/FIX AS REQUIRED OR PROVIDE NEW WINDOW TREATMENTS
<br />TO MATCH BUILDING STANDARD THROUGHOUT, U.O.N. MOUNT WINDOW TREATMENTS TO WINDOW
<br />USING ONLY METHODS APPROVED BY THE BUILDING OWNER/LANDLORD.
<br />34.PROVIDE ADDITIONAL EXIT SIGNS AS REQUIRED BY THE FIRE INSPECTOR.
<br />35.ALL (E) CEILING AND ASSOCIATED CEILING DEVICES ARE TO REMAIN, U.O.N.
<br />ADDITIONAL NOTES:
<br />THE LIGHTING PACKAGE AS OUTLINED IN THE (RCP) LEGEND IS PROPRIETARY AND HAS BEEN APPROVED BY THE
<br />OWNER/CLIENT FOR THE DESIGN INTENT FOR THIS PROJECT.
<br />PRIOR TO FINAL BID SUBMITTAL, THE GENERAL CONTRACTOR SHALL VERIFY THIS LIGHTING PACKAGE CONFORMS
<br />TO THE PROPOSED PROJECT SCHEDULE. IF THERE ARE ANY SCHEDULE CONFLICTS, THE GENERAL CONTRACTOR
<br />SHALL PROMPTLY NOTIFY THE CLIENT/DESIGNER. SUB-CONTRACTOR TO PROVIDE UNIT PRICING PER FIXTURE; ANY
<br />BIDS NOT CONTAINING UNIT PRICING WILL BE ELIMINATED.
<br />AFTER AWARD OF CONTRACT, ANY CHANGE ORDERS DUE TO MODIFICATIONS TO THIS LIGHTING PACKAGE
<br />WILL NOT BE ACCEPTED. MOREOVER, THE GENERAL CONTRACTOR, SUBCONTRACTORS, AND ANY OTHER
<br />CONTRACTOR INVOLVED IN THIS PROJECT SHALL TAKE NOTE THAT ANY COSTS DUE TO REMEDIAL WORK AS A
<br />RESULT OF, BUT NOT LIMITED TO, DEVIATION FROM THE LIGHTING PACKAGE, INFERIOR WORKMANSHIP OR
<br />MATERIALS, AND/OR IMPROPER SCHEDULING OR DELINQUENT ORDERING, SHALL BE BORNE BY THE RESPONSIBLE
<br />PARTY.
<br />KEYNOTES
<br />SCALE :
<br />NORTH
<br />REFLECTED CEILING PLAN
<br />1/8" = 1'-0"
<br />SHADED AREA INDICATES PORTION OF BUILDING NOT
<br />INCLUDED IN SCOPE OF WORK (NIC)
<br />FLOOR-TO-STRUCTURE ABOVE PARTITION (NON-RATED)
<br />MILLWORK
<br />BLDG STD FIRE EXTINGUISHER CABINET. SEE DETAIL 5/ID5.1
<br />EXISTING PARTITION TO REMAIN
<br />REFER TO SHEET ID4.0
<br />REFER TO DETAIL 5/ID5.1
<br />EXISTING DOOR TO REMAIN
<br />NEW OR RELOCATED DOOR AS SCHEDULED#REFER TO ID3.0
<br />FE
<br />FEC
<br />BLDG STD FIRE EXTINGUISHER
<br />C1
<br />C2 REFER TO DETAIL
<br />3/ID5.0
<br />REFER TO DETAIL
<br />1/ID5.0
<br />ID2.0
<br />PARTITION PLAN AND
<br />REFLECTED CEILING PLAN
<br />SCALE :
<br />NORTH
<br />PARTITION PLAN
<br />1/8" = 1'-0"
<br />EXISTING GYPSUM BOARD CEILING TO REMAIN
<br />NEW GYPSUM BOARD CEILING. REFER TO SHEET id5.2
<br />A1
<br />PARTITION TYPE DESIGNATION (I.E. 1-HOUR RATED, FULL-HEIGHT, LOW-HEIGHT, ETC.)
<br />MODIFIER. REFER TO PARTITION DETAIL FOR DETAILED INFORMATION REGARDING STUD
<br />GAUGE, SIZE & FRAMING AND ANY ADDITIONAL COMMENTS RELATED TO THE
<br />CONSTRUCTION OF PARTITION TYPE
<br />FLOOR-TO-STRUCTURE ABOVE PARTITION (NON-RATED)
<br />10 SOFFIT TO ALIGN WITH MILLWORK BELOW
<br />F1
<br />F2 LED LIGHT TRACK LIGHT
<br />SPECIFICATION: WAC LIGHTING PALOMA LED512:
<br />WHK-LED512-F36°-35-870-_-BK
<br />PENDANT CYLINDER LED LIGHT
<br />SPECIFICATION: CAMMAN LIGHTING:
<br />P4020-24-35K-50-CLV-MV-WM
<br />F3
<br />LED LIGHT TRACK LIGHT
<br />SPECIFICATION: WAC LIGHTING PALOMA LED512:
<br />WHK-LED512-F36°-35-870-_-BK
<br />F4
<br />LED LIGHT TRACK LIGHT
<br />SPECIFICATION: WAC LIGHTING PALOMA LED512:
<br />WHK-LED512-F36°-35-870-_-BK
<br />12" X 12" FLOOR SINK
<br />FLOOR DRAIN
<br />F1 REFER TO DETAIL
<br />5/ID5.0PARTIAL HEIGHT FURRING PARTITION (NON-RATED)
<br />11 EXISTING DRYWALL CEILING AND RECESSED LIGHTS TO REMAIN
<br />12 ALL EXISTING DUCT WORK/HVAC EQUIPMENT ABOVE EXISTING DRYWALL CEILING TO REMAIN
<br />ENCLOSED.
<br />13 TRACK LIGHTS FIXTURES AT SOFFIT AND DRYWALL CEILINGS SHALL BE MOUNTED FLUSH TO THE CEILING
<br />A
<br />A
<br />1 AUTOMATIC DOOR ACTUATOR
|