Laserfiche WebLink
DN <br />UP <br />DN <br />UP <br />UP <br />(E) WOMENS <br />RESTROOM <br />104OFFICE <br />111 <br />OFFICE <br />110 <br />(E) MENS <br />RESTROOM <br />103 <br />(E) OPEN <br />OFFICE <br />106 <br />(E) <br />EXIT CORRIDOR <br />- <br />(D) <br />(D)(D) <br />(D) <br />(E) <br />(E) <br />(E) <br />(E) <br />(E) <br />(E) <br />DN <br />UP <br />DN <br />UP <br />UP <br />(E) WOMENS <br />RESTROOM <br />104OFFICE <br />111 <br />OFFICE <br />110 <br />(E) MENS <br />RESTROOM <br />103 <br />(E) OPEN <br />OFFICE <br />106 <br />(E) <br />EXIT CORRIDOR <br />- <br />OPEN TO <br />ABOVE <br />(E) <br />(E) <br />(D) <br />DN <br />UP <br />DN <br />UP <br />UP <br />(E) WOMENS <br />RESTROOM <br />104OFFICE <br />111 <br />OFFICE <br />110 <br />(E) MENS <br />RESTROOM <br />103 <br />(E) OPEN <br />OFFICE <br />106 <br />(E) <br />EXIT CORRIDOR <br />- <br />DN <br />UP <br />DN <br />UP <br />UP <br />(E) WOMENS <br />RESTROOM <br />104OFFICE <br />111 <br />OFFICE <br />110 <br />(E) MENS <br />RESTROOM <br />103 <br />(E) OPEN <br />OFFICE <br />106 <br />(E) <br />EXIT CORRIDOR <br />- <br />(E) <br />(E) <br />Sheet Title: <br />ISSUE DATE <br />ISSUE FOR PLANCHECK 12.22.2025 <br />All drawings and written material appearing herein constitute the original and <br />unpublished work of MAD Studio and the same may not be duplicated, used <br />or disclosed without the written consent of MAD Studio. <br />Sheet No.: <br />ISSUE DESCRIPTION <br />ENGINEER/CONSULTANT <br />ARCHITECT/ENGINEER STAMP <br />30 <br />5 <br /> <br />W <br /> <br />4 <br />T <br />H <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />CA <br />F <br />E <br />OA <br />S <br />I <br />S <br />CLIENT <br />www.madstudiola.com <br />CITY STAMP <br />Project Director: <br />Project Designer: <br />Project Tech: <br />Project No:25030.300E.M. <br />E.M. <br />S.P. <br />ISSUED FOR MEP 01.13.2026 <br />ISSUED FOR PLAN CHECK COMMENTS- PLANNING DEPT.01.22.2026 <br />ISSUED FOR PRICING 02.17.2026 <br />ISSUED FOR PLAN CHECK COMMENTS - PLANNING DEPT.02.20.2026 <br />ISSUED FOR COUNTY REVIEW 03.24.2026 <br />ISSUED FOR ADDENDUM A 03.27.2026 <br />ISSUED FOR BUILDING DEPT REVIEW 04.08.2026 <br />ISSUED FOR BUILDING DEPT REVIEW - RESUBMITTAL 05.05.2026 <br />ISSUED FOR BUILDING DEPT CORRECTIONS 05.20.2026 <br />KEYNOTESSHEET NOTES LEGEND <br />1.REFER TO SHEET ID0.1 FOR GENERAL DEMOLITION NOTES. <br />2.REFER TO PARTITION PLAN FOR EXTENT OF DEMOLITION. <br />3.REFER TO ENGINEER'S DRAWINGS FOR ADDITIONAL DEMOLITION SCOPE. <br />4.THE GENERAL CONTRACTOR SHALL VISIT AND WALK THE PROJECT SITE PRIOR TO DETERMINING THE EXTENT <br />OF DEMOLITION WORK TO BE DONE. <br />5.ALL TRADES TO INSPECT EXISTING SITE CONDITIONS PRIOR TO SUBMITTING BIDS. CONTRACTOR TO NOTIFY <br />MAD OF ANY CONFLICT BETWEEN EXISTING CONDITIONS AND THE DRAWINGS. <br />6.THE GENERAL CONTRACTOR SHALL PATCH AND REPAIR EXISTING WALLS TO REMAIN WHERE DEMOLITION <br />OCCURS AND PREP WALLS TO RECEIVE NEW FINISHES AS INDICATED ON FINISH PLAN(S) AND/OR <br />SCHEDULE(S). <br />7.ALL DEMOLISHED DOORS, FRAMES AND DOOR HARDWARE TO BE SAVED AND STORED FOR POSSIBLE RE-USE. <br />8.ALL EXISTING POWER AND DATA RECEPTACLES AND ASSOCIATED WIRING ARE TO REMAIN, U.O.N. THE <br />GENERAL CONTRACTOR SHALL VERIFY IN THE FIELD THE LOCATION AND FUNCTIONAL CAPACITY OF ALL <br />EXISTING TO REMAIN OUTLETS AND NOTIFY THE DESIGNER OF ANY DISCREPANCIES BETWEEN THE <br />DRAWINGS AND EXISTING CONDITIONS. <br />9.WHERE PARTITIONS ARE DEMOLISHED, REMOVE ALL TELEPHONE, POWER, DATA RECEPTACLES, ETC AND ALL <br />ASSOCIATED WIRING ALL THE WAY BACK TO THE ORIGINATING SOURCE. <br />10.WHERE EXISTING PLUMBING FIXTURES ARE REMOVED, CAP-OFF EXISTING PLUMBING LINES AT THE SOURCE. <br />11.ALL EXISTING FLOOR CORES AND ASSOCIATED WIRING NOTED TO BE REMOVED SHALL BE TERMINATED ALL <br />THE WAY BACK TO ITS ORIGINATING SOURCE. FILL-IN CONCRETE SLAB WHERE OUTLETS ARE REMOVED. <br />12.GENERAL CONTRACTOR TO VERIFY EXISTING WALL BASE HEIGHT AND SKIM WALL AS REQUIRED TO RECEIVE <br />NEW WALL BASE. <br />13.IN ALL AREAS WHERE DEMOLITION (REMOVAL OF TILE, CARPETING, TACKLESS, PARTITIONS, ETC.) CAUSES AN <br />UNEVENNESS IN SLAB, THE CONTRACTOR SHALL PATCH/REPAIR/PREP THE SLAB FOR A SMOOTH LEVEL FLOOR <br />TO RECEIVE NEW FLOOR FINISHES. <br />14.CONTRACTOR SHALL DEMO AND REMOVE ALL ABANDONED CABLING IN THE CEILING TO THE POINT OF <br />ORIGIN AS REQUIRED BY LOCAL GOVERNING ELECTRICAL CODES, INCLUDING BUT NOT LIMITED TO THE <br />FOLLOWING; PHONE CABLE, COAXIAL CABLE, TV CABLE, LOW VOLTAGE CABLE, AND CONTROL WIRING NOT <br />BEING UTILIZED. <br />15.CONTRACTOR SHALL INSTALL FILTERS IN THE MAIN RETURN HVAC TRUNK WHILE IN CONSTRUCTION. <br />16.CONTRACTOR SHALL PATCH AND/OR REPAIR ALL EXISTING WALLS, COLUMNS, SILLS, ETC. WHICH ARE <br />DAMAGED OR EFFECTED BY DEMOLITION. EXISTING PARTITIONS SHALL BE EQUAL TO NEW. <br />REFLECTED CEILING DEMOLITION NOTES <br />17.REFER TO SHEET ID0.1 FOR GENERAL DEMOLITION NOTES AND ID0.2 FOR GENERAL REFLECTED CEILING <br />NOTES. REFER TO SHEET ID1.0 FOR (FLOOR) DEMOLITION PLAN. <br />18.REFER TO REFLECTED CEILING PLAN FOR EXTENT OF CEILING DEMOLITION. <br />19.REFER TO ENGINEER'S DRAWINGS FOR ADDITIONAL DEMOLITION SCOPE. <br />20.ALL DEMOLISHED CEILING FIXTURES (LIGHTS, EXIT SIGNS, ETC) ARE TO BE SAVED AND STORED FOR POSSIBLE <br />RE-USE. <br />21.ALL DEMOLISHED CEILING GRID AND TILES ARE TO BE SAVED, AND STORED FOR POSSIBLE RE-USE. <br />22.CONTRACTOR SHALL DEMO AND REMOVE ALL ABANDONED CABLING IN THE CEILING TO THE POINT OF <br />ORIGIN AS REQUIRED BY CITY OF LOS ANGELES ELECTRICAL CODES, INCLUDING BUT NOT LIMITED TO THE <br />FOLLOWING; PHONE CABLE, COAXIAL CABLE, TV CABLE, LOW VOLTAGE CABLE, AND CONTROL WIRING NOT <br />BEING UTILIZED. <br />23.CONTRACTOR SHALL INSTALL FILTERS IN THE MAIN RETURN HVAC TRUNK WHILE IN CONSTRUCTION. <br />24.CONTRACTOR SHALL PATCH AND/OR REPAIR ALL EXISTING WALLS, COLUMNS, SILLS, ETC. WHICH ARE <br />DAMAGED OR EFFECTED BY DEMOLITION. EXISTING PARTITIONS SHALL BE EQUAL TO NEW. <br />SYMBOL DESCRIPTION SYMBOL DESCRIPTION <br />SCALE : <br />NORTH <br />DEMOLITION PLAN <br />1/8" = 1'-0" <br />ID1.0 <br />DEMOLITION PLAN AND <br />REFLECTED CEILING <br />DEMOLITION PLAN <br />EXISTING PARTITION TO REMAIN <br />EXISTING PARTITION TO BE REMOVED <br />SHADED AREA INDICATES PORTION OF BUILDING NOT INCLUDED IN SCOPE OF WORK <br />(NIC) <br />EXISTING DOOR TO BE REMOVED <br />DENOTES EXISTING TO BE REMOVED(D) <br />DENOTES EXISTING TO BE ABANDONED(A) <br />DENOTES EXISTING TO REMAIN(E) <br />EXISTING DOOR TO REMAIN <br />EXISTING GYPSUM BOARD CEILING TO REMAIN <br />EXISTING ACOUSTICAL CEILING TILE SYSTEM TO REMAIN <br />EXISTING ACOUSTICAL CEILING TILE SYSTEM TO BE REMOVED <br />EXISTING GYPSUM BOARD CEILING TO BE REMOVED <br />DENOTES EXISTING TO BE REMOVED(D) <br />DENOTES EXISTING TO BE ABANDONED(A) <br />DENOTES EXISTING TO REMAIN(E) <br />DENOTES EXISTING TO BE RELOCATED(R) <br />SCALE : <br />NORTH <br />REFLECTED CEILING DEMOLITION PLAN <br />1/8" = 1'-0"