Laserfiche WebLink
305 W 4TH STREET, SANTA ANA, CA, 92701 <br />SYMBOLS <br />BUILDING DEPARTMENT NOTES <br />FIRE DEPARTMENT NOTES <br />PROJECT DIRECTORY SHEET INDEXABBREVIATIONS <br />VICINITY MAP <br />BUILDING SUMMARY/SCOPE OF WORK <br />ARCHITECTURAL DRAWINGSEXISTING BUILDING INFORMATION <br />CONSTRUCTION TYPE: <br />NUMBER OF FLOORS: <br />SPRINKLERED: <br />OCCUPANCY TYPE: <br />PARCEL: <br />LEGAL DESCRIPTION: <br />ROOM DESIGNATION <br />ELEVATION NUMBER <br />V-B <br />EXISTING 3 (AND BASEMENT LEVEL) <br />YES (EXISTING) - ALL MODIFICATION SHALL BE REVIEWED AND APPROVED BY OCFA <br />PRIOR TO FINAL OF THE BUILDING PERMIT. <br />EXISTING 'B' <br />398-255-20 <br />SEC 12 T5R10 LOT2 25 X 100 FT <br />CAfe oasis <br />1 <br />ROOM NAME <br />No. <br />MECHANICAL DRAWINGS <br />ELECTRICAL DRAWINGS <br />PLUMBING DRAWINGS <br />id1.0 DEMOLITION PLAN AND CEILING DEMO PLAN <br />id2.0 PARTITION PLAN AND REFLECTED CEILING PLAN <br />id2.1 POWER & SIGNAL PLAN AND FURNITURE PLAN (FOR REFERENCE ONLY) <br />id2.2 WALL FINISH PLAN AND FLOOR FINISH PLAN <br />id3.0 DOOR AND HARDWARE SCHEDULE <br />id4.0 INTERIOR ELEVATIONS <br />id4.1 INTERIOR ELEVATIONS <br />id5.0 PARTITION CONSTRUCTION DETAILS <br />id5.2 CEILING CONSTRUCTION DETAILS <br />id6.0 MILLWORK DETAILS <br />M1.0 MECHANICAL DEMOLITION AND REMOVAL PLAN <br />M2.0 MECHANICAL DETAILS SHEET <br />E0.1 ELECTRICAL LEAD SHEET <br />E0.3 ELECTRICAL TITLE 24 <br />P0.1 PLUMBING LEAD SHEET <br />P2.0 PLUMBING REMODEL PLANS <br />ADJUSTABLE <br />ACOUSTICAL <br />ACOUSTICAL <br />ABOVE FINISH FLOOR <br />ARCHITECTURAL <br />BUILDING <br />BOTTOM <br />ANODIZED <br />APPROXIMATE <br />CONTRACTOR <br />COLUMN <br />CONCRETE <br />CONNECTION <br />CONTINUOUS <br />CENTERLINE <br />DRINKING FOUNTAIN <br />DIAMETER <br />DIAMETER <br />EXISTING <br />DIMENSION <br />DRAWING <br />CORRIDOR <br />CERAMIC TILE <br />FINISH FACE <br />EXPOSED <br />FLOOR DRAIN <br />GALVANIZED <br />FIRE EXTINGUISHER <br />ALUMINUM <br />F.F. <br />GAUGEGA. <br />GALV. <br />FT.FOOT <br />FIN. <br />FLR. <br />FINISH <br />FLOOR <br />DOORDR. <br />EQUALEQ. <br />EXP. <br />F.D. <br />F.E.C. <br />(E) <br />DWG. <br />D.F. <br />Ø <br />DIA. <br />DIM. <br />CORR. <br />C.T. <br />DET.DETAIL <br />BOARDBD. <br />CONC. <br />CONN. <br />CONT. <br />CONTR. <br />COL. <br />CLO. <br />CLR. <br />CLOSET <br />CLEAR <br />C <br />CLG.CEILING <br />BLDG. <br />BLK. <br />BOT. <br />BLOCK <br />A.F.F. <br />ANOD. <br />@ <br />APPROX. <br />ARCH. <br />AT <br />ACOUS. <br />ALUM. <br />A.C.T. <br />ADJ. <br />SOLID CORE <br />VINYL COMPOSITIONV.C.T. <br />WALL COVERINGW.C. <br />WD.WOOD <br />W/ <br />W/O WITHOUT <br />WITH <br />SCHEDULED <br />STANDARD <br />SPECIFICATIONS <br />STAINLESS STEEL <br />STRUCTURAL <br />SUSPENDED <br />TELEPHONE <br />TEMPERED GLASS <br />UNLESS OTHERWISE <br />STORAGESTOR. <br />TEMP.GL. <br />THK. <br />TYP. <br />U.O.N. <br />TYPICAL <br />THICK <br />SUSP. <br />STRUCT. <br />TELE. <br />SPECS. <br />STD. <br />STL. <br />S.S. <br />STEEL <br />S.C. <br />SCHED. <br />SECT. <br />SIM. <br />SECTION <br />SIMILAR <br />MISC. <br />NOT IN CONTRACT <br />NOT TO SCALE <br />ON CENTER <br />OPPOSITE HAND <br />OWNER PROVIDE & <br />RM. <br />REQ'D.REQUIRED <br />ROOM <br />O.P.I. <br />OPNG. <br />OPP. <br />OPENING <br />O.C. <br />O.P.C.I. <br />O/OVER <br />MTD. <br />N.I.C. <br />N.T.S. <br />MOUNTED <br />HARDWOOD <br />GYPSUM BOARD <br />LAVATORY <br />MECHANICAL <br />MANUFACTURER <br />MISCELLANEOUS <br />HDWD. <br />MECH. <br />MFR. <br />MIN. <br />MET./MTL. <br />MINIMUM <br />METAL <br />HT. <br />LAV. <br />HEIGHT <br />GL. <br />GYP. BD. <br />GLASS <br />L <br />CABINETCAB. <br />ABANDON(A) <br />(D)DEMOLISH <br />CONTRACTOR INSTALL <br />OWNER PROVIDE & <br />CABINET <br />INSTALL <br />NOTED <br />TILE <br />CEILING TILE <br />F.O.S.FACE OF STUD <br />MAXIMUMMAX. <br />MUL.MULLION <br />R.O.ROUGH OPENING <br />V.I.F.VERIFY IN FIELD <br />SPACESP. <br />(R)RELOCATED <br />CEILING HEIGHT REFERENCE <br />KEY NOTE <br />ELEVATION REFERENCE <br />SHEET NUMBER <br />DETAIL NUMBER <br />DETAIL REFERENCE <br />SHEET NUMBER <br />SECTION NUMBER <br />SECTION REFERENCE <br />SHEET NUMBER <br />DETAIL NUMBER <br />PLAN DETAIL REFERENCE <br />SHEET NUMBER <br />A <br />ALIGNMENT OF NEW AND EXISTING ELEMENTS <br />MAT.SURFACE MATERIAL REFERENCE <br />1 FIXTURE REFERENCE <br />1 EQUIPMENT REFERENCE <br />WALL FINISH SPECIFICATION <br />BASE MATERIAL SPECIFICTION <br />WALL/BASE FINISH REFERENCE <br />FLOOR FINISH REFERENCEC <br />1 <br />FLOOR FINISH DIRECTION <br />FLOOR FINISH TRANSITIONFINFIN <br />NORTH <br />APPLICABLE CODES: <br />STATE BUILDING STANDARDS (CCR, TITLE 24, 2025 EDITION) <br />MECHANICAL ELECTRICAL PLUMBING WORK SHALL BE ON SEPERATE BUILDING PERMITS. <br />FIRE LIFE SAFETY/FIRE PROTECTION WORK SHALL BE ON SEPARATE PERMITS. <br />PART 2.CALIFORNIA BUILDING CODE W/ CITY AMMENDMENTS <br />PART 3.CALIFORNIA ELECTRICAL CODE W/ CITY AMMENDMENTS <br />PART 4.CALIFORNIA MECHANICAL CODE W/ CITY AMMENDMENTS <br />PART 5.CALIFORNIA PLUMBING CODE W/ CITY AMMENDMENTS <br />PART 6.CALIFORNIA ENERGY EFFICIENCY STANDARDS W/ CITY AMMENDMENTS <br />PART 7.CALIFORNIA ELEVATOR SAFETY CONSTRUCTION CODE W/ CITY AMMENDMENTS <br />PART 8.CALIFORNIA HISTORICAL BUILDING CODE W/ CITY AMMENDMENTS <br />PART 9.CALIFORNIA FIRE CODE W/ CITY AMMENDMENTS <br />PART 10 CALIFORNIA CODE FOR BUILDING CONSERVATION W/ CITY AMMENDMENTS <br />PART 12 CALIFORNIA REFERENCE STANDARDS CODE W/ CITY AMMENDMENTS <br />id5.1 CONSTRUCTION DETAILS <br />id0.0 COVER SHEET <br />id0.1 GENERAL NOTES <br />id0.2 GENERAL NOTES <br />id0.4 NOT USED <br />id0.3 GENERAL ACCESSIBILITY NOTES <br />DEFERRED SUBMITTALS: <br />FIRE PROTECTION WORK - BACK-FLOW ASSEMBLY UPGRADES UNDER SEPARATE PERMIT. <br />1.FIRE PROTECTION WORK SHALL BE PERFORMED ON A DESIGN/BUILD BASIS UNDER SEPARATE PERMITS. <br />2.RESPECTIVE CONTRACTORS SHALL BE RESPONSIBLE FOR PLAN CHECK REVIEWS/APPROVALS AND <br />SECURING APPROPRIATE BUILDING PERMITS. <br />DESIGN BUILD WORK <br />1.ALL WORK SHALL CONFORM TO THE 2025 CALIFORNIA BUILDING CODE. <br />2.THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO ANY <br />WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL-BOXES, TRANSFORMERS, VAULTS, PUMPS, <br />VALVES, METERS, APPURTENANCES, ETC.) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION <br />SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES-WHETHER OR NOT THE LINES ARE LOCATED ON THE <br />PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES. <br />3.THE FACILITIES INCLUDING, BUT NOT LIMITED TO, SANITARY FACILITIES, DRINKING FOUNTAINS, AND <br />ELEVATORS ON ALL FLOORS, MUST COMPLY WITH ACCESSIBILITY REQUIREMENTS. <br />4.TOILET FACILITIES SHALL BE IDENTIFIED BY SIGNAGE IN COMPLIANCE WITH THE INTERNATIONAL SYMBOL OF <br />ACCESSIBILITY (CBC CHAPTER 11). <br />5.THE PATH OF TRAVEL FROM THE DESIGNATED HANDICAP PARKING SPACES AND THE PUBLIC SIDEWALK <br />PROVIDES A FREE AND UNOBSTRUCTED PASSAGE FOR ACCESS TO AND EGRESS FROM THE AREA OF WORK. <br />6.DOORS SHALL BE NOT LESS THAN 3'-0" IN WIDTH AND NOT LESS THAN 6'-8" IN HEIGHT. <br />7.FLOORS OR LANDINGS LOCATED AT A DOORWAY SHALL BE NOT MORE THAN 1/2" LOWER THAN THE TOP OF <br />THE THRESHOLD, WHICH SHALL HAVE A 1/4" MAXIMUM VERTICAL EDGE AND A CHANGE IN LEVEL NOT <br />GREATER THAN 1:2. <br />8.A CLEAR AND LEVEL AREA SHALL BE PROVIDED ON EACH SIDE OF EXIT DOORS WITH A LENGTH OF AT LEAST <br />60" IN THE DIRECTION OF THE DOOR SWING AND AT LEAST 48" IN THE OPPOSITE DIRECTION, MEASURED AT <br />RIGHT ANGLES THE DOOR IN ITS CLOSED POSITION. <br />HEIGHT <br />MATERIAL <br />SCOPE OF WORK: <br />TENANT IMPROVEMENT TO EXISTING OFFICE SPACE. EXISTING 'B' <br />OCCUPANCY TO REMAIN, NO CHANGE IN USE. <br />1ST FLOOR USABLE AREA:±2,133 SQ.FT. <br />SCOPE OF WORK:±800 SQ.FT. <br />1.THE CONTRACTOR SHALL SUPPLY AND INSTALL A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS <br />THAN 2-A OR 2-A10BC WITHIN 75'-0" TRAVEL DISTANCE TO ALL PORTIONS OF THE FLOOR, AND ANY <br />ADDITIONAL FIRE EXTINGUISHERS AS REQUIRED BY FIRE DEPARTMENT FIELD INSPECTOR. FIRE EXTINGUISHERS <br />SHALL ALSO BE PROVIDED DURING CONSTRUCTION. <br />2.DRAPES AND OTHER DECORATIVE MATERIALS SHALL BE FLAME RETARDANT. CERTIFICATION THEREOF SHALL BE <br />PROVIDED. EXITS, EXIT LIGHTS, FIRE ALARM STATIONS, HOSE CABINETS AND EXTINGUISHER LOCATIONS <br />SHALL NOT BE CONCEALED BY DECORATIVE MATERIAL (CBC CHAPTER 8). <br />3.INTERIOR WALL AND CEILING FINISHES FOR OFFICES SHALL BE OF CLASS C PER TABLE 803.11AND NOT <br />EXCEED A FLAME SPREAD INDEX OF 76-200 PER SECTION 803.1.1 OF CBC 2022. <br />4.INTERIOR WALL AND CEILING FINISHES FOR EXIT CORRIDORS AND STAIRWELLS SHALL BE OF CLASS B PER <br />TABLE 803.11 AND NOT EXCEED THE FLAME SPREAD INDEX OF 26-75 PER SECTION 803.1.1 OF CBC 2022. <br />5.ANY DECORATIONS USED SHALL BE NON-COMBUSTIBLE OR FLAME-RETARDANT TREATED IN AN APPROVED <br />MANNER (CURTAINS, DRAPES, SHADES, ETC.). <br />6.EXIT SIGNS SHALL BE ELECTRICALLY ILLUMINATED AND THE TWO LAMPS SHALL BE ENERGIZED FROM SEPARATE <br />CIRCUITS. ILLUMINATION SHALL NORMALLY BE PROVIDED BY THE PREMISES WIRING SYSTEMS. IN THE EVENT <br />OF THIS SYSTEM'S FAILURE, ILLUMINATION SHALL BE AUTOMATICALLY PROVIDED FROM AN EMERGENCY <br />SYSTEM. EMERGENCY LIGHTING SHALL GIVE A VALUE OF ONE FOOT-CANDLE AT FLOOR LEVEL (CBC <br />CHAPTER 10). <br />7.WHENEVER THE BUILDING IS OCCUPIED, EXIT SIGNS SHALL BE LIT SO THAT THEY ARE CLEARLY VISIBLE. <br />8.PROVIDE EXIT SIGNS WITH MINIMUM 6" HIGH BLOCK LETTERS WITH 3/4" STROKE ON A CONTRASTING <br />BACKGROUND. INDICATE THE LOCATION OF EXIT SIGNS ON PLANS (CBC CHAPTER 10). <br />9.EXIT PATH LIGHTING SHALL BE PROVIDED AT STAIRWAY, HALLWAY, EXIT PASSAGEWAY, AND EGRESS TO A <br />PUBLIC WAY WHENEVER THE BUILDING IS OCCUPIED, PER CBC CHAPTER 10. <br />10.EMERGENCY LIGHTING SYSTEM IS REQUIRED AND MUST COMPLY WITH CBC CHAPTER 10. <br />11.ALL FIRE ALARM DEVICES SHALL BE LOCATED AS NOTED BELOW. <br />12.ALTERATIONS TO THE FIRE AND LIFE SAFETY SYSTEM SHALL BE UNDER SEPARATE PERMIT FROM THE FIRE <br />PREVENTION SECTION PLANS. PERMIT APPLICATIONS AND FEES SHALL BE SUBMITTED AND PERMIT APPROVAL <br />SHALL BE OBTAINED PRIOR TO COMMENCEMENT OF ANY WORK ON THE FIRE AND LIFE SAFETY SYSTEM. <br />13.PROVIDE AN APPROVED FIRE ALARM SYSTEM WITH A DESCRIPTION OF SEQUENCE OF OPERATION AND LISTED <br />STATE FIRE MARSHALL APPROVED EQUIPMENT. <br />14.SUBMIT THREE COMPLETE SETS OF PLANS TO ELECTRICAL DIVISION, DEPARTMENT OF BUILDING AND SAFETY <br />FOR THE ABOVE REQUIREMENTS, ONE SET DESIGNATED AS THE FIRE DEPARTMENT COPY. <br />15.PROVIDE AUTOMATIC FIRE EXTINGUISHING SYSTEM THROUGHOUT THE FLOOR. ALTERATIONS TO THE <br />AUTOMATIC FIRE SPRINKLER SYSTEM SHALL BE UNDER SEPARATE PERMIT FROM THE FIRE PREVENTION <br />SECTION PLANS. PERMIT APPLICATIONS AND FEES SHALL BE SUBMITTED AND PERMIT APPROVAL SHALL BE <br />OBTAINED PRIOR TO COMMENCEMENT OF ANY WORK ON THE FIRE PROTECTION SYSTEM. <br />16.SPRINKLER SYSTEM SHALL BE APPROVED BY PLUMBING DIVISION OF LOCAL BUILDING DEPARTMENT PRIOR TO <br />INSTALLATION (CBC CHAPTER 9). <br />17.ELEVATOR DOORS SHALL NOT OPEN DIRECTLY INTO ONE-HOUR CORRIDORS (CBC CHAPTER 30). <br />18.KEY-LOCKING HARDWARE MAY BE USED ON THE MAIN EXIT WHEN THE MAIN EXIT CONSISTS OF A SINGLE <br />DOOR OR PAIR OF DOORS IF THERE IS A READILY VISIBLE, DURABLE SIGN ON OR ADJACENT TO THE DOOR <br />STATING "THIS DOOR MUST REMAIN UNLOCKED DURING BUSINESS HOURS". <br />19.EXIT CORRIDORS, EXTERIOR EXIT BALCONIES, AND AISLES LEADING TO REQUIRED EXITS SHALL HAVE A <br />MINIMUM WIDTH OF 44" (CBC CHAPTER 10). <br />20.AN EXIT WALKWAY WITH A MINIMUM WIDTH OF 44" SHALL BE MAINTAINED CONTINUOUSLY TO A PUBLIC <br />WAY (CBC CHAPTER 10). EXIT PATHS OR WALKWAYS TO PUBLIC WAY SHALL BE CLEARLY DELINEATED BY <br />PAINTED LINES, RAILINGS, BARRIER POSTS, WALKS, OR OTHER APPROVED MEANS. <br />21.GLAZING INSTALLED IN ONE-HOUR CORRIDOR MUST BE 1/2" WIRED GLASS IN STEEL FRAMES AND SHALL <br />NOT EXCEED 25% OF CORRIDOR/ROOM COMMON WALL. <br />22.FIRE DAMPERS OR DOORS SHALL BE PROVIDED WHERE HVAC DUCTS PENETRATE FIRE-RATED WALLS OR <br />CEILINGS. <br />id0.5 EXISTING SITEPLAN/ P.O.T. (FOR INFORMATION ONLY) <br />id0.7 OCCUPANCY/EGRESS PLAN <br />id0.6 EXISTING RESTROOMS (FOR INFORMATION ONLY) <br />MAD STUDIOMAD <br />OWNER/LANDLORD:S&A MANAGEMENT <br />RYAN CHASE <br />129 W. WILSON ST., STE 100 <br />COSTA MESA, CA 92627 <br />EMAIL: <br />DESIGN FIRM:MAD STUDIO <br />ED MELGAR <br />670 GLENMORE BLVD. <br />GLENDALE, CALIFORNIA 91206 <br />EMAIL: ed@madstudiola.com <br />PHONE: 818.795.3900 <br />GENERAL CONTRACTOR:CLUNE CONSTRUCTION <br />JASON RIVERA <br />725 S. FIGUEROA ST., STE 300 <br />LOS ANGELES, CA 90017 <br />PHONE: 213.437.6260 <br />EMAIL: jrivera@clunegc.com <br />MEP ENGINEERS:LAM AND KAAINONI ENGINEERING <br />MATT KAAINONI <br />617 W. 7TH STREET, STE 301 <br />LOS ANGELES, CA 90017 <br />EMAIL: matt.kaainoni@lamkaainoni.com <br />TENANT OASIS CENTER INTERNATIONAL <br />JIN SUNG <br />305 W. 4TH STREET <br />SANTA ANA, CA 92701 <br />EMAIL: jsung@oasiscenterintl.org <br />PROJECT SITE <br />M0.1 MECHANICAL LEAD SHEET <br />M0.2 MECHANICAL SCHEDULE SHEET <br />E0.2 ELECTRICAL SINGLE LINE AND DETAILS <br />E1.0 ELECTRICAL DEMOLITION AND POWER PLANS <br />E2.0 ELECTRICAL LIGHTING AND PHOTOMETRIC PLANS <br />P1.0 PLUMBING DEMOLITION PLAN <br />P3.0 PLUMBING DIAGRAMS <br />P4.0 PLUMBING DETAILS <br />Sheet Title: <br />ISSUE DATE <br />ISSUE FOR PLANCHECK 12.22.2025 <br />All drawings and written material appearing herein constitute the original and <br />unpublished work of MAD Studio and the same may not be duplicated, used <br />or disclosed without the written consent of MAD Studio. <br />Sheet No.: <br />ISSUE DESCRIPTION <br />ENGINEER/CONSULTANT <br />ARCHITECT/ENGINEER STAMP <br />30 <br />5 <br /> <br />W <br /> <br />4 <br />T <br />H <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />CA <br />F <br />E <br />OA <br />S <br />I <br />S <br />CLIENT <br />www.madstudiola.com <br />CITY STAMP <br />Project Director: <br />Project Designer: <br />Project Tech: <br />Project No:25030.300E.M. <br />E.M. <br />S.P. <br />ISSUED FOR MEP 01.13.2026 <br />ISSUED FOR PLAN CHECK COMMENTS- PLANNING DEPT.01.22.2026 <br />ISSUED FOR PRICING 02.17.2026 <br />ISSUED FOR PLAN CHECK COMMENTS - PLANNING DEPT.02.20.2026 <br />ISSUED FOR COUNTY REVIEW 03.24.2026 <br />ISSUED FOR ADDENDUM A 03.27.2026 <br />ISSUED FOR BUILDING DEPT REVIEW 04.08.2026 <br />ISSUED FOR BUILDING DEPT REVIEW - RESUBMITTAL 05.05.2026 <br />ISSUED FOR BUILDING DEPT CORRECTIONS 05.20.2026 <br />ID0.0 <br />COVER SHEET