PLUMBING ABBREVIATION KEY <br />PLUMBING CONTRACTORP.C. <br />I.E.INVERT ELEVATION (FOR REFERENCE ONLY) <br />LAVATORYL or LAV <br />PLUMBINGPLBG <br />SHOWERSH <br />SINKSK <br />URINALUR <br />WATER CLOSETWC <br />VENT THROUGH ROOFVTR <br />AD ACCESS DOOR <br />ABOVE FINISHED FLOORAFF <br />BFP BACKFLOW PREVENTER <br />ABBR:DESCRIPTION: <br />TYPICALTYP <br />EXISTINGE <br />HEALTH CARE ACCESS AND INFORMATIONHCAI <br />DOWNDN <br />PLAN OR DETAIL NUMBER <br />PLAN OR DETAIL NAME <br />PLAN OR DETAIL SCALE <br />DETAIL REFERRED TO BY SECTION CUT <br />SHEET DETAIL IS LOCATED ON <br />NAME <br />1 VIEW NAME <br />1/8" = 1'-0" <br />1 <br />M101 <br />1 <br />4 <br />3 <br />2 <br />SIMSIM <br />INDICATES SIMILAR DETAIL REFERENCED <br />IN MULTIPLE LOCATIONS <br />LEVEL NAME <br />10'-0"HEIGHT ABOVE <br />PROJECT 0'-0" <br />1 KEYNOTE: INDICATES NOTE USED TO <br />DESCRIBE ADDITIONAL INFORMATION <br />ABOUT WORK REQUIRED, SPECIFIC <br />TO THE SHEET AND/OR DETAIL <br />NO R HT <br />INDICATES DIRECTION OF TRUE NORTH <br />VIEW KEY <br />LINE TYPE AND TAG KEY: <br />NEW WORK BY THIS CONTRACTOR (WIDE LINE) <br />EXISTING TO REMAIN OR WORK BY OTHERS (NARROW LINE) <br />HALFTONING DOES NOT MODIFY SCOPE. <br />'TAG'-E TAGS WITH DASH 'E' INDICATES THE REFERENCED OBJECT IS EXISTING <br />TAG-1 UNDERLINED TAG INDICATES OBJECT IS IN-SCOPE. IF NEW, ADDITIONAL <br />INFORMATION IS AVAILABLE IN A SCHEDULE, MATERIAL LIST, OR SYMBOL LIST <br />INDICATES AN EXISTING SYSTEM'S POINT OF CONNECTION/REMOVAL <br />T101 <br />NEW <br />EXISTING TO BE REMOVED (SHORT DASHED PATTERN) <br />NEW UNDERFLOOR OR UNDERGROUND (LONG DASHED PATTERN) <br />EXISTING <br />EXISTING TO BE REMOVED BY OTHERS (SHORT DASHED PATTERN) <br />EXISTING UNDERFLOOR OR UNDERGROUND (LONG DASHED PATTERN) <br />PLUMBING SYMBOL LIST <br />SYMBOL:DESCRIPTION: <br />PIPE SERVING FIXTURE ON FLOOR ABOVE <br />(EXAMPLE: FD = FLOOR DRAIN)FD <br />PITCH PIPE IN DIRECTION <br />BALANCING VALVE (NUMBER INDICATES GPM)GPM <br />CHECK VALVE <br />REDUCER -REFERENCE SPECIFICATION <br />FOR CONCENTRIC/ECCENTRIC AND FOT/FOB <br />PIPE CAP <br />PIPE DOWN <br />PIPE UP OR UP/DOWN <br />DIRECTION OF FLOW IN PIPE <br />SHUTOFF VALVE NORMALLY OPEN <br />SHUTOFF VALVE NORMALLY CLOSED <br />COLD WATER -POTABLECW <br />HOT WATER -POTABLEHW <br />HOT WATER CIRCULATING -POTABLEHWC <br />SANITARY DRAINAGESAN <br />VENTV <br />DRAIND <br />NOT ALL SYMBOLS MAY APPLY. <br />PIPE CONTINUATION <br />BACKFLOW PREVENTER <br />1. THE SYMBOLS AND THE MATERIAL LIST ARE FOR THE CONVENIENCE OF THE CONTRACTOR. <br /> CONTRACTOR SHALL VERIFY QUANTITIES AND FURNISH ALL MATERIALS REQUIRED FOR <br /> FULLY OPERATIONAL SYSTEMS, WHETHER SPECIFIED OR NOT. <br />2. CATALOG NUMBERS SHALL NOT BE CONSIDERED COMPLETE, BUT ARE GIVEN AS AN AID TO <br /> THE CONTRACTOR AND TO INDICATE THE QUALITY REQUIRED. CONTRACTOR IS <br /> RESPONSIBLE FOR A COMPLETE DESCRIPTION OF MATERIAL ON THESE DRAWINGS AND IN <br /> THE SPECIFICATIONS BEFORE ORDERING. THE DESCRIPTION OF THE MATERIAL TAKES <br /> PRECEDENCE OVER THE CATALOG NUMBER. THE FIRST MANUFACTURER LISTED IS THE <br /> BASIS OF DESIGN. <br />3. CONTRACTOR SHALL VERIFY THAT FIXTURES SUPPLIED ARE APPROVED PER ALL <br /> APPLICABLE STATE, LOCAL AND GOVERNING AUTHORITIES. <br />4. ALL FIXTURES SHALL CONFORM TO FEDERAL ACT S.3874 <br />5. INVERT ELEVATIONS ARE FROM EXISTING DRAWINGS AND MAY NOT BE ACCURATE. VERIFY <br /> ALL ELEVATIONS BEFORE BEGINNING WORK. <br />6. VERIFY UNDERGROUND PIPE SIZES, INVERT ELEVATIONS, AND LOCATIONS PRIOR TO <br /> BEGINNING ANY WORK. <br />7. REFER TO THE PLUMBING ROUGH-IN SCHEDULE FOR THE SIZES OF BRANCH PIPES TO <br /> PLUMBING FIXTURES. <br />8. EXISTING CONDITIONS ON DEMOLITION PLANS ARE PROVIDED TO INDICATE THE GENERAL <br /> SCOPE OF ITEMS TO BE REMOVED. <br />9. P.C. SHALL CUT AND PATCH EXISTING AS REQUIRED FOR NEW OR DEMOLITION WORK <br /> UNLESS NOTED OTHERWISE. <br />10. DRAWINGS SHOWING LOCATIONS OF EQUIPMENT, AND PIPING, ETC. ARE DIAGRAMMATIC <br /> AND MAY NOT ALWAYS REFLECT EXACT INSTALLATION CONDITIONS. DRAWINGS SHOW THE <br /> GENERAL ARRANGEMENT OF PIPING, EQUIPMENT, ETC., AND MAY NOT INCLUDE ALL <br /> OFFSETS AND FITTINGS REQUIRED FOR COMPLETE INSTALLATION. THE DRAWINGS SHALL <br /> BE FOLLOWED AS CLOSELY AS ACTUAL BUILDING CONSTRUCTION AND THE WORK OF <br /> OTHERS WILL PERMIT. <br />11. DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS AND CLEARANCES FROM <br /> ARCHITECTURAL, STRUCTURAL, SUBMITTALS, AND OTHER APPROPRIATE DRAWINGS OR <br /> PHYSICALLY AT SITE. REVIEW ALL DRAWINGS, INCLUDING THOSE OF OTHER TRADES. <br />12. COORDINATE ALL WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION TO PROVIDE <br /> CLEARANCES REQUIRED FOR OPERATION, MAINTENANCE, CODE COMPLIANCE, AND TO <br /> VERIFY NON-INTERFERENCE WITH OTHER WORK. DO NOT FABRICATE PRIOR TO <br /> VERIFICATION OF NECESSARY CLEARANCES FOR ALL TRADES. BRING ANY INTERFERENCES <br /> OR CONFLICTS TO THE ATTENTION OF THE ARCHITECT/ENGINEER BEFORE PROCEEDING <br /> WITH FABRICATION OR EQUIPMENT ORDERS. <br />13. REVIEW SPACE REQUIREMENTS OF EQUIPMENT SPECIFIED OR SUBSTITUTED AND MAKE <br /> REASONABLE ACCOMMODATIONS IN LAYOUT AND POSITIONING TO PROVIDE PROPER <br /> ACCESS. <br />14. ANY CHANGES REQUIRED TO ELIMINATE CONFLICTS OR THAT RESULT FROM A FAILURE TO <br /> COORDINATE SHALL BE MADE BY THE CONTRACTOR WITHOUT ADDITIONAL COST OR <br /> EXPENSE TO OTHERS. <br />15. EACH CONTRACTOR IS RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH ELECTRICAL <br /> CHANGES REQUIRED FOR EQUIPMENT PROPOSED THAT DIFFERS FROM THE BASIS OF <br /> DESIGN. <br />16. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN, ELECTRICAL, TECHNOLOGY <br /> AUDIO/VISUAL, AND OTHER MECHANICAL PLANS FOR EXACT LOCATIONS OF ALL CEILING <br /> MOUNTED DEVICES, OTHER THAN SPRINKLERS. <br />17. EACH CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY THEIR ACTIONS TO WALLS, <br /> FLOORS, CEILINGS, AND ROOFS. THE CONTRACTOR WHOSE WORK CAUSES DAMAGE IS <br /> RESPONSIBLE FOR PATCHING TO MATCH ORIGINAL CONSTRUCTION, FIRE RATING, AND <br /> FINISH. <br />18. SEAL ALL FLOOR, WALL, AND ROOF PENETRATIONS AIRTIGHT WHERE PIPING PENETRATE. <br /> PENETRATIONS THROUGH EXTERIOR WALLS AND ROOF SHALL BE SEALED AIRTIGHT WITH <br /> WATERPROOFING MATERIALS RECOMMENDED BY MANUFACTURER FOR OUTDOOR USE. <br />19. CAULK ALL PIPE PENETRATIONS OF FULL HEIGHT NON-FIRE RATED WALL, PARTITION, <br /> FLOOR, AND ROOF ASSEMBLIES. THIS IS ESSENTIAL TO PREVENT NOISE TRANSMISSION <br /> FROM ONE ROOM TO ANOTHER AND TO PROVIDE THE DESIRED NC LEVELS WITHIN ROOMS. <br />20. WHERE PIPES ARE SHOWN TO PENETRATE FLOORS, PROVIDE SLEEVED OPENINGS WITH <br /> THE TOP EDGE RAISED ABOVE FLOOR SURFACE IN ACCORDANCE WITH ALL RELEVANT <br />SPEC. <br /> SECTIONS. SEAL SLEEVE PERIMETER TO BE WATERTIGHT. <br />21. DO NOT BLOCK TUBE PULL OR EQUIPMENT SERVICE CLEARANCES. <br />22. DO NOT SUPPORT PIPING FROM METAL DECKING OR OTHER NON-STRUCTURAL BUILDING <br /> ELEMENTS. ANCHORS EMBEDDED IN CONCRETE SHALL BE CRACKED CONCRETE <br />APPROVED <br /> IN ACCORDANCE WITH SPECIFICATIONS. <br />23. EXISTING CONDITIONS ARE SHOWN BASED ON INFORMATION OBTAINED FROM FIELD <br /> SURVEYS, EXISTING BUILDING DOCUMENTS, AND STAFF. VERIFY EXISTING CONDITIONS AND <br /> REPORT ANY CONFLICTS BEFORE PROCEEDING. <br />24. NOT ALL EXISTING PIPING IS SHOWN. VERIFY EXISTING CONDITIONS BEFORE <br /> STARTINGWORK. NOTIFY ENGINEER OF ANY CONFLICTS WITH NEW WORK. <br />25. FIELD VERIFY THE AVAILABLE CLEARANCES FOR DUCTWORK AND PIPING BEFORE <br /> FABRICATION. RISES AND DROPS MAY BE NECESSARY BECAUSE OF EXISTING FIELD <br /> CONDITIONS. <br />28. THE P.C. IS RESPONSIBLE FOR CUTTING, REMOVAL AND PATCHING OF ROOFS, WALLS, AND <br /> FLOORS ASSOCIATED WITH WORK BY ALL CONTRACTORS. <br />29. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND REPLACEMENT OF <br /> CEILINGS, CEILING TILES, AND CEILING GRIDS ASSOCIATED WITH AREAS OF WORK BY ALL <br /> CONTRACTORS. <br />30. WHERE EXISTING MECHANICAL SYSTEMS ARE LOCATED IN AREAS THAT CONFLICT WITH <br /> NEW PIPING, OR DUCTWORK TO BE INSTALLED, EACH CONTRACTOR SHALL EITHER <br /> ARRANGE NEW PIPING IN SUCH A FASHION THAT IT DOES NOT CONFLICT WITH EXISTING <br /> SYSTEMS. <br />31. PROVIDE TEMPORARY CONNECTIONS TO MAINTAIN EXISTING SYSTEMS IN SERVICE DURING <br />CONSTRUCTION. MAINTAIN ACCESS TO EXISTING MECHANICAL INSTALLATIONS THAT <br /> REMAIN ACTIVE. <br />32. OBTAIN PERMISSION FROM OWNER BEFORE SHUTTING DOWN ANY SYSTEM FOR ANY <br /> REASON. MAINTAIN SERVICE TO ALL COMPONENTS THAT ARE TO REMAIN UNTIL NEW <br /> SYSTEMS ARE INSTALLED <br />PLUMBING GENERAL NOTES: <br />APPLICABLE CODES <br />CONTRACTOR SHALL COMPLY WITH APPLICABLE CODES AND LOCAL AMENDMENTS <br />INCLUDING, BUT NOT LIMITED TO, THE FOLLOWING: <br />2022 CALIFORNIA BUILDING STANDARDS ADMINISTRATIVE CODE <br />CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 1 <br />2022 CALIFORNIA BUILDING CODE (CBC) <br />CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 2 <br />(2021 INTERNATIONAL BUILDING CODE (IBC) W/ 2022 CALIFORNIA AMENDMENTS) <br />2022 CALIFORNIA ELECTRICAL CODE (CEC) <br />CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 3 <br />(2020 NATIONAL ELECTRICAL CODE (NEC) W/ 2022 CALIFORNIA AMENDMENTS) <br />2022 CALIFORNIA MECHANICAL CODE (CMC) <br />CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 4 <br />(2021 UNIFORM MECHANICAL CODE (UMC) W/ 2022 CALIFORNIA AMENDMENTS) <br />2022 CALIFORNIA PLUMBING CODE (CPC) <br />CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 5 <br />(2021 UNIFORM MECHANICAL CODE (UPC) W/ 2022 CALIFORNIA AMENDMENTS) <br />2022 CALIFORNIA ENERGY CODE <br />CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 6 <br />2022 CALIFORNIA FIRE CODE (CFC) <br />CALIFORNIA CODES OF REGULATIONS (CRR) TITLE 24, PART 9 <br />(2021 INTERNATIONAL FIRE CODE (IFC) W/ 2022 CALIFORNIA AMENDMENTS) <br />2022 CALIFORNIA EXISTING BUILDING CODE <br />CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 10 <br />(2021 INTERNATIONAL EXISTING BUILDING CODE (IEBC)) <br />2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGREEN) <br />CALIFORNIA CODES OF REGULATIONS (CCR) TITLE 24, PART 11 <br />2022 CALIFORNIA REFERENCED STANDARDS CODE <br />CALIFORNIA DOE OF REGULATIONS (CCR) TITLE 24, PART 12 <br />J <br />FINISHED FLOOR <br />FINISHED CEILING <br />J-BOX IN CEILING SPACE <br />3/4" CONDUIT <br />PROVIDED BY ELECTRICAL <br />PROVIDED BY <br />CHICAGO SENSOR FAUCET <br />TRANSFORMER #243.259.00.1 <br />PROVIDED BY PLUMBER <br />ELECTRICAL <br />LOW VOLTAGE <br />WIRING PROVIDED <br />BY PLUMBER <br />CONDUIT TO STUB-OUT <br />BELOW SINK SO THAT <br />LOW VOLTAGE WIRE IS <br />NOT VISIBLE <br />INSTALLATION WIRE <br /># 242.340.00.1 <br />FINISHED FLOOR <br />3/4" CONDUIT <br />PROVIDED BY <br />ELECTRICAL <br />SENSOR BOX <br />FLOOR <br />MOUNTED <br />WATER CLOSET <br />LOW <br />VOLTAGE <br />WIRING <br />PROVIDED BY <br />PLUMBER. <br />J-BOX IN CEILING <br />SPACE PROVIDED <br />BY ELECTRICAL <br />CONDUIT STUB OUT <br />FOR LOW VOLTAGE <br />WIRING <br />CONNECTION. <br />PLUMBING SHEET INDEX <br />P000 PLUMBING COVERSHEET <br />P002 PLUMBING SPECIFICATIONS <br />P101 LEVEL 01 - PLUMBING - REMODEL PLAN - OVERALL <br />P102 LEVEL 02 - PLUMBING - REMODEL PLAN - OVERALL <br />P103 LEVEL 03 - PLUMBING - REMODEL PLAN - OVERALL <br />P111 LEVEL 01 - ENLARGED PLUMBING DEMOLITION AND REMODEL PLAN <br />P113 LEVEL 02 - ENLARGED PLUMBING DEMOLITION AND REMODEL PLAN - AREA A <br />P115 LEVEL 03 - ENLARGED PLUMBING DEMOLITION AND REMODEL PLAN <br />GRAND TOTAL: 8 <br />NOTES: (APPLIES TO ALL PLUMBING FIXTURES LISTED BELOW) <br />1) SIZES SHOWN ARE MINIMUMS. LARGER SIZES SHOWN ON THE DRAWING SHALL DICTATE THE ROUGH-IN SIZE. <br />2) SANITARY RISERS UP IN WALL TO FIXTURES SHALL BE A MINUMUM OF 2". 3) DOMESTIC WATER BRANCH <br />PIPING OUTSIDE OF THE WALL/CHASE SHALL BE A MINIMUM OF 3/4" UNLESS NOTED OTHERWISE. ONLY THE <br />FINAL RISE-DROP SHALL BE SMALLER. 4) FINAL SANITARY SIZE SHALL MATCH P-TRAP SIZE (REFER TO MATERIAL <br />LIST). <br />PLUMBING ROUGH-IN SCHEDULE <br />TAG NAME DESCRIPTION TRAP <br />COLD <br />WATER <br />HOT <br />WATER SANITARY VENT <br />L-1 LAVATORY 1/2" 1/2" 1 1/2" 1 1/2" <br />WC-1 WATER CLOSET 1 1/2" - 4" 2" <br />LACINAHCEM AINROFILACFOETATS <br />M29915 <br />Exp. 06/30/26 <br />REGISTERED PROFESSIONAL <br />ENGINEER <br />ROBERT M .OKAJIMA <br />IMEG RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO <br />THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAW ING <br />AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG AND SHALL NOT <br />BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE <br />EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF IMEG. <br />©2024 IMEG CONSULTANTS CORP. <br />REF. SCALE IN INCHES <br />0 1 2 3 <br />222 S. HARBOR BOULEVARD <br />SUITE 800 <br />ANAHEIM, CA 92805 <br />P: 714.490.5555 F: 714.490.5560 <br />The FUTURE. Built Smarter www.imegcorp.com <br />PROJECT #24007312.00 <br />0 5' <br />GRAPHIC SCALES: <br />Issue Date <br />1/16" = 1'-0" <br />50' <br />1/8" = 1'-0" 1/4" = 1'-0" 1/2" = 1'-0" 3/4" = 1'-0"1" = 1'-0"1-1/2" = 1'-0" 3" = 1'-0" <br />0 5'25'0 1'12'0 1'6'0 4'0 3'1' 0 2'0 1' <br />Chckd By <br />Drwn By <br />Scale <br />Building ID: <br />KP Proj. No. <br />Permit No. <br />Sheet <br />SheetsOf <br />Sheet Title <br />Project <br />Facility <br />This document is the property of the Owner and is <br />Project Architect Approval: <br />Architect/Engineer Of Record: <br />IF THIS SHEET IS NOT 30"x42" , IT IS <br />A REDUCED PRINT - SCALE ACCORDINGLY <br />National Facilities Services <br />Post Office Box 12916 <br />Oakland California 94604 <br />not to be used without owner's written permission. <br />Floor Lev:Section: <br />HGW Proj. No. <br />© <br />A <br />R <br />C <br />H <br />I <br />T <br />E <br />C <br />T <br />S <br /> <br />h <br />a <br />n <br />n <br />a <br /> <br />g <br />a <br />b <br />r <br />i <br />e <br />l <br /> <br />w <br />e <br />l <br />l <br />s <br />, <br /> <br />a <br />l <br />l <br /> <br />r <br />i <br />g <br />h <br />t <br />s <br /> <br />r <br />e <br />s <br />e <br />r <br />v <br />e <br />d <br />. <br /> <br />A <br />n <br />y <br /> <br />u <br />s <br />e <br /> <br />w <br />i <br />t <br />h <br />o <br />u <br />t <br /> <br />p <br />e <br />r <br />m <br />i <br />s <br />s <br />i <br />o <br />n <br /> <br />i <br />s <br /> <br />e <br />x <br />p <br />r <br />e <br />s <br />s <br />l <br />y <br /> <br />p <br />r <br />o <br />h <br />i <br />b <br />i <br />t <br />e <br />d <br />. <br /> <br />P <br />l <br />o <br />t <br />t <br />e <br />d <br />CAP029271 <br />1955 Bacon Street. San Diego, CA 92107 <br />Office 619 523 8487 <br />www.hgwarchitecture.com <br />PROJECT #24007312.00 <br />Revisions <br />By Appr. <br />As indicated <br />9/ <br />2 <br />5 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />5 <br />: <br />1 <br />3 <br />: <br />2 <br />1 <br /> <br />P <br />M <br />08/15/2025 <br />Checker <br />Author <br />P000 <br />PLUMBING COVERSHEET <br />3401 South Harbor Boulevard, <br />Santa Ana, CA 92704 <br />10 <br />0 <br />% <br /> <br />C <br />D <br /> <br />S <br />E <br />T <br />2441 <br />HARBOR-MAC ARTHUR <br />PLUMBING MATERIAL LIST <br />TAG NAME DESCRIPTION MANUFACTURER AND MODEL <br />L-1 LAVATORY: UNDERMOUNT, ACRYLIC BOWL, INSIDE BOWL <br />DIMENSIONS 19.5”W x 14.375”Lx 6.75”D WITH CHICAGO <br />FAUCET 327-XCP GRID DRAIN, MCGUIRE P-TRAP AND <br />CHICAGO FAUCET 1017-CABCP STOPS AND SUPPLY. <br />FAUCET: BLUETOOTH ADAPTER, 4" TRIM PLATE, BOX <br />TRANSFORMER POWER SUPPLY, INTEGRATED SIDE <br />MIXER, POLISHED CHROME FINISH, 0.5 GPM, <br />MULTI-LAMINAR SPRAY, INFRARED SENSOR, BASYS® <br />HARDWIRED-POWERED DECK-MOUNTED HIGH BODY, <br />HARDWIRED WITH BOX MOUNT ADAPTER. <br />LAVATORY: DURASEIN <br />#DLB379A <br />FAUCET: SLOAN <br />#EFX-100-4-BOX-ISM-CP-0.5GP <br />M-MLM-FCT <br />BOX MOUNT ADAPTER: <br />SLOAN EAF-37 BASYS® EFX <br />100-240 VAC/6 VDC <br />WC-1 WATER CLOSET: FLOOR MOUNTED FLUSHOMETER VALVE <br />TOILET, VITREOUS CHINA, HIGH EFFICIENCY, LOW <br />CONSUMPTION, DUEL FLUSH 1.1/1.28 GPF <br />FULLY GLAZED ELONGATED BOWL, TOP SPUD, <br />10 OR 12" ROUGH-IN FILED VERIFY. <br />FLUSH VALVE: EXPOSED SENSOR OPERATED <br />SELECTRONIC FLUSH VALVE, TOP SPUD, HARDWIRED TO <br />AC POWER WITH TRANSFORMER AND 10’ EXTENSION CABLE. <br />WATER CLOSET: AMERICAN <br />STANDARD #2234.001 <br />FLUSH VALVE: AMERICAN <br />STANDARD #606B.721 <br />TRANSFORMER: AMERICAN <br />STANDARD #PK00.MAC <br />MULTI-AC ADAPTER AND 10' <br />EXTENSION CABLE. <br />NTS3SINK SENSOR FAUCET HARD WIREWIRED DETAIL <br />NTS4WATER CLOSET FLUSH VALVE HARDWIRED DETAIL <br />SHEET P114 NO PLUMBING SCOPE FOR REFERNCE ONLY <br />No. Revisions Date <br />pl <br />a <br />n <br /> <br />c <br />h <br />e <br />c <br />k <br /> <br />s <br />u <br />b <br />m <br />i <br />t <br />t <br />a <br />l <br />09/19/2025 <br />90% CD 08/14/2025 <br />Plan Check Submittal 09/19/2025 <br />pl <br />a <br />n <br /> <br />c <br />h <br />e <br />c <br />k <br /> <br />r <br />e <br />s <br />u <br />b <br />m <br />i <br />t <br />t <br />a <br />l <br />Plan Check Resubmittal 02/25/2026 <br />02/25/2026