My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2424 N Oakmont Ave, Unit 2 - REV 1 - Plan
PBA
>
Building
>
ProjectDox
>
O
>
Oakmont Ave
>
2424 N Oakmont Ave Unit# 2
>
2424 N Oakmont Ave, Unit 2 - REV 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2026 5:00:13 AM
Creation date
6/9/2026 5:00:06 AM
Metadata
Fields
Template:
Plan
Permit Number
101122996
101126268
101126591
Full Address
2424 N Oakmont Ave Unit# 2
2424 N Oakmont Ave
Street Number
2424
Street Direction
N
Street Name
Oakmont
Street Suffix
Ave
Unit Number
2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
REF PANTRY <br />W/D <br />WH <br />DW <br />FAU <br />linen <br />cl <br />o <br />s <br />e <br />t <br />SCALE: 1/4" = 1' <br />project <br />sheet <br />ADU <br />Santa Ana <br />California <br />92706 <br />Oakmont Ave <br />Uradomo Gurman <br />stamp <br />plot date <br />project <br />sheet <br />revision <br />construction <br />bid issue <br />revision <br />revision <br />b.d. submittal <br />title <br />3.31.2026 <br />Gurman <br />2424 <br />Unit 2 <br />Uradomo <br />2.18.2025 <br />OWNR 1 2.6.2026 <br />1 <br />Mechanical <br />A2.1 <br />+ <br />Electrical <br />Electrical, Mechanical + Reflected Ceiling Plan <br />Reflected Ceiling, Mechanical + Electrical Keynotes <br />S <br />4S <br />3 <br />S <br />VS <br />S <br />Electrical Notes <br /> Electrical Legend <br />BATHROOM EXHAUST FANS SHALL BE ENERGY STAR COMPLIANT . UNLESS FUNCTIONING AS A <br />COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, FANS MUST BE CONTROLLED BY A <br />HUMIDISTAT WHICH SHALL BE READILY ACCESSIBLE. HUMIDISTAT CONTROLS SHALL BE CAPABLE <br />OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGE OF 50 TO 80 PERCENT. THE CONTROL <br />MAY BE MANUAL OR AUTOMATIC. A BACK DRAFT DAMPER IS REQUIRED. <br />EXHAUST VENT S MUST TERMINATE OUTSIDE THE BUILDING, A MIN OF 3FT FROM ANY OPENING OR <br />PROPERTY LINE. <br />ALL EXHAUST FANS TO BE SWITCHED SEPARATELY FROM LIGHTING FIXTURES PER CEnC 150(k)2B <br />ALL DUCTS AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED <br />WITH TAPE, PLASTIC, OR OTHER ACCEPTABLE MATERIAL AT THE TIME OF ROUGH INSTALLATION OR <br />DURING STORAGE UNTIL FINAL STARTUP <br />Mechanical Notes <br />KITCHEN RANGE HOOD TO HAVE A MINIMUM 30' VERTICAL CLEARANCE OVER STOVE [CMC <br />1961A&B] MUST HAVE MINIMUM 100 CFM WITH 5 AIR CHANGES PER MINUTE. HOOD DUCTWORK TO <br />BE SEALED WITH UL 181 NON-CLOTH BACKED TAPE AND INSULATED WITH A MINIMUM R-VALUE OF <br />4.2 AND SUPPORTED EVERY 4 [CMC 604.2,605.5 TABLE 6.7] EXHAUST DUCT SHALL BE AIR TIGHT <br />AND BE EQUIPPED WITH A BACK DRAFT DAMPER - DUCTING SHALL BE GALVANIZED STEEL <br />STAINLESS STEEL OR COPPER WITH A SMOOTH INTERIOR FINISH [CMC 604.2 (4)]. <br />EX 2X10 ROOF RAFTERS FOR R-38C BATT INSULATION CLEARANCE <br />3b <br />3a <br />3c <br />3e <br />MS <br />AIR DISTRIBUTION DUCTS TO HAVE R-8 VALUE PER TITLE 24 . <br />PROPOSED ELECTRICAL SUB-PANEL LOCATION TO BE VERIFIED <br />HEAT PUMP PER TITLE 24 <br />NOTE: <br />Mechanical, electrical and plumbing are not part of this <br />plan review and approval. MEP are subject to building <br />field inspection <br />SCALE: 1/4" = 1'2Roof Plan <br />Existing 2-car Garage <br />EX <br />I <br />S <br />T <br />I <br />N <br />G <br />+ <br />1 <br />/ <br />2 <br /> <br />: <br />1 <br />2 <br />_ <br />SL <br />O <br />P <br />E <br />SSSS <br />S <br />SS <br />S SSS <br />S <br />SS <br />Bedroom 2 <br /> Area <br />Bath <br />Living <br />S <br />3 <br />33 <br />3 S <br />Roof <br />Plans <br />AREA OF BUR RE-ROOF <br />Roof Plan Keynotes <br />Roof Legend <br />10a <br />NEW SKYLIGHT - VELUX ICC ESR- 4108 10b <br />10c <br />10d EXISTING DOWNSPOUT AND OVERFLOW <br />NEW SKYLIGHT <br />REROOF - BUILT UP ROOFING GAFGLAS PLY4 <br />SLOPE 1/2" PER FOOT MIN. <br />ICC ESR-1274 , CLASS "A" RATING <br />(OR APPROVED EQUAL) WITH COOL ROOF COATING <br />REMOVE EXISTING SKYLIGHT <br />Skylight Underlayment <br />Skylight Flashing 4 <br />3 <br />EX <br />I <br />S <br />T <br />I <br />N <br />G <br />+ <br />1 <br />/ <br />2 <br /> <br />: <br /> <br />1 <br />2 <br />_ <br />SL <br />O <br />P <br />E <br />10e DASHED LINE INDICATES LINE OF WALLS BELOW <br />MAX U-FACTOR = 0.48; MAX SHGC = 0.27 PER TITLE 24 CALCS <br />REFER TO DETAILS 3 + 4 THIS SHEET <br />10a <br />10c <br />10d <br />10a <br />10d <br />10e <br />10b 10b <br />10f CRICKET AT SKYLIGHT <br />10f <br />10f <br />Existing 2-car Garage <br />TYP TYP <br />4. <br />5. <br />3. <br />1. <br />2. <br />6. <br />7. <br />CONSULT WITH OWNER ABOUT LANDSCAPE LIGHTING <br />IMMEDIATELY IN CASE OF DISCREPANCIES AND UNUSUAL CONDITIONS. <br />CONTRACTOR TO REVIEW ALL FIELD CONDITIONS AND NOTIFY DESIGNER <br />ALL WALL OUTLETS SWITCHES AND CONTROLS SHALL NOT BE MORE THAN 48" AFF TO TOP <br />SWITCHES AND OUTLETS AT KITCHEN SPLASH AND LAUNDRY SPLASH TO BE <br />ALL SWITCHES ADJACENT TO DOORS WITH CASING TO BE SET 1/2" MIN. FROM <br />INDOORS, IN BATHROOMS, IN BASEMENT, AT COUNTERTOP SURFACE (WITHIN <br />PROVIDE G.F.I. PROTECTION TO ALL 120 VOLT, 15 & 20 AMP RECEPTACLES INSTALLED <br />6 FT. OF A SINK), & GARAGES. EXCEPTION: SINGLE OUTLET RECEPTACLES IN <br />ALL CONDUCTORS TO BE COPPER. <br />CASING TO EDGE OF PLATE. <br />ABOVE BACKSPLASH <br />a. <br />b. <br />c. <br />OUTLET AND SWITCH HEIGHTS: <br />GARAGES UTILIZED FOR A FIXED OR STATIONARY APPLIANCE <br />VERIFY HEIGHT OF WALL MOUNTED SCONCES PRIOR TO PULLING WIRES TO BOXES. <br />13. <br />14. <br />ALL BRANCH CIRCUITS THAT SUPPLY 120 VOLT, SINGLE PHASE, 15 AND 20 AMP OUTLETS <br /> INSTALLED IN DWELLING UNIT KITCHENS, FAMILY ROOMS, DINING ROOMS, LIIVING RMS, PARLORS, <br />INTERRUPTER(S), COMBINATION TYPE - REQD FOR THE ENTIRE CIRCUIT, NOT JUST OUTLETS. <br />15. <br />ALL LUMINAIRES SHALL BE HIGH EFFICACY PER CEnc TABLE 150.0-A <br />16. <br />ALL PERMANANTLY INSTALLED LUMINAIRES SHALL BE SHOWN WITH A MANUAL ON/OFF <br /> SWITCH AND CONTROLS WHERE REQUIRED BY CEnC 150.0(K) 2 FOR INTERIOR LIGHTS <br />LUMINAIRES THAT ARE RECESSED INTO INSULATED CEILINGS ARE REQUIRED TO BE <br />RATED FOR ZERO CLEARANCE INSULATION CONTACT (IC-RATED) SO THAT INSULATION <br />THE HOUSING OF THE LUMINAIRE SHALL BE AIRTIGHT TO PREVENT CONDITIONED AIR <br />ESCAPING INTO THE CEILING CAVITY OR ATTIC, UNCONDITIONED AIR INFILTRATING <br />FROM THE CEILING OR ATTIC INTO THE CONDITIONED SPACE. <br />AND 50.0(K)3 FOR EXTERIOR LIGHTS <br />CAN BE PLACED OVER THEM. <br /> PER CEC 210.12 <br />LIBRARIES, DENS, BEDROOMSK SUNROOMS, RECREATION RMS, CLOSETS, HALLWAYS, LAUNDRY <br />AREAS, OR SIMILAR ROOMS OR AREAS, SHALL BE PROTECTED BY A LISTED ARC-FAULT CIRCUIT <br />8.ALL 120-VOLT RECEPTACLE OUTLETS SHALL BE LISTED AS TAMPER-RESISTANT RECEPTACLES <br />PROVIDE AT LEAST ONE RECEPTACLE IN BATHROOMS ADJACENT TO EACH BASIN OR LAV. <br />SUCH RECEPTACLES SHALL HAVE GROUND FAULT CIRCUIT INTERRUPTER AND PROTECTION & <br />11. AT LEAST ONE 20-AMPERE BRANCH CIRCUIT SHALL BE PROVIDED TO SUPPLY THE BATHROOM <br />RECEPTACLE OUTLETS. SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS (NEC 210.11c.3) <br />PROVIDE A MIN OF 2 SEPARATE 20-AMP CIRCUITS TO KITCHEN APPLIANCES. THE TWO OR MORE <br />SMALL APPLIANCE BRANCH CIRCUITS SHALL HAVE NO OTHER OUTLETS. PROVIDE NOTE ON THE <br />9. <br />PER CEC 406.12 <br />AND BE LOCATED WITHIN 36 INCHES OF THE OUTSIDE EDGE OF THE BASIN (CEC 210.52d and 210.8a) <br />EXTERIOR RECEPTACLE OUTLETS SHALL BE 120-VOLT, WEATHERPROOF GFI AND SHALL BE <br />INDICATED AS "WP/GFI" (CEC 210.52e, 210.8a AND 406.9b) <br />10. <br />12. <br />PLANS (CEC 210.52b) <br />PER TITLE 24 (OR APPROVED EQUIVALENT) <br />RECOMMENDATIONS. WHERE FLASHING MUST BE EXPOSED, FLASHING SHALL <br />OVERLAPS AND EDGES SHALL BE PER ROOFING MANUFACTURER <br />FELT PAPER, 2 LAYERS 15# FELT PAPER SHALL LAY IN CONTINUOUS STRIPS, <br />OF 12" TYP. FLASHING SHALL BE LAID ON A CONTINUOUS STRIP (36" WIDE) OF 30" <br />FLASHING SHALL EXTEND UP / DOWN ADJACENT SURFACES A MIN. <br />ALL RIDGES, HIPS AND VALLEYS SHALL BE FLASHED W/ MIN 24 GA ALUMINUM <br />ALL FASTENERS TO RESIST WIND LOAD OF NOT LESS THAN 110 MPH. <br />ALL ROOF FASTENERS SHALL BE INSTALLED PER MANUFACTURER'S SPECS2. <br />3. <br />4. <br />BE MIN 24 GA ALUMINUM W/ PAINT FINISH OR APPROVED EQUAL <br />1. <br />FLASHING (CONTINUOUS) AND SHALL NOT BE VISIBLE. <br />WHERE CEILING IS TIGHT TO STRUCTURE TYP. - INSULATION BLOCK <br />PROVIDE INSULATION IN ALL ATTIC SPACES AND BETWEEN ALL ROOF RAFTERS <br />OR APPROVED EQUAL - A MIN OF 1 INCH OF AIR SPACE SHALL BE PROVIDED <br />BETWEEN THE INSULATION AND THE ROOF SHEATHING <br />Base flashing against a vertical sidewall shall be continuous or step flashing and shall be <br />not less than 4 inches (102 mm) in height and 4 inches (102 mm) in width and shall direct <br />water away from the vertical sidewall onto the roof or into the gutter. Where exterior <br />plaster is provided on the vertical sidewall, the base flashing shall be provided in <br />accordance with R905.2.8.3 and Section R703.6.3 <br />Roofing Notes <br />10f CEILING TIGHT TO STRUCTURE - TYP <br />WITH CONTRACTOR <br />CATHEDRAL CEILING TIGHT TO STRUCTURE TYPICAL - FURR DOWN <br />3b <br />3a <br />3c <br />3e <br />3a <br />3a <br />3a <br />3d EXTERIOR 16 SEER (12.2 EER) A/C CONDENSER PER TITLE 24 <br />3d <br /> WATER HEATER, RHEEM PROPH40 T2 RH37515 (40 gal, JA13) PER TITLE 24 <br />10c10c <br />S <br />Bedroom 1 <br />S <br />S <br />S3 <br />S <br />S <br />3a <br />S <br />S <br />1 <br />1 <br />10c <br />EXCEPTIONS: DEDICATED OUTLETS, FLOOR OUTLETS, CONTROLS ON CEILING FANS, <br />LIGHTS, AND APPLIANCES; AND OUTLETS REQUIRED BY CEC ON A WALL WHERE THE <br />OF OUTLET BOX AND NOT LESS THAN 15" AFF FROM BOTTOM OF THE OUTLET BOX AFF. <br />DISTANCE BETWEEN FINISH FLOOR AND A BUILT-IN FEATURE (WINDOW) IS LESS THAN 15" <br />1
The URL can be used to link to this page
Your browser does not support the video tag.