Laserfiche WebLink
REF PANTRY <br />W/D <br />WH <br />DW <br />FAU <br />linen <br />cl <br />o <br />s <br />e <br />t <br />SCALE: 1/4" = 1'Floor Plan <br />Door Schedule <br />DESCRIPTION <br />Window Schedule <br />NO. <br />6'-0" <br />NO.WIDTH <br />DESCRIPTION <br />project <br />sheet <br />ADU <br />Santa Ana <br />California <br />92706 <br />Oakmont Ave <br />Uradomo Gurman <br />stamp <br />plot date <br />project <br />sheet <br />revision <br />construction <br />bid issue <br />revision <br />revision <br />b.d. submittal <br />title <br />4.15.2025 <br />Gurman <br />2424 <br />Unit 2 <br />Uradomo <br />2.18.2025 <br />OWNR 1 2.6.2026 <br />FRENCH DOOR <br />1 <br />+ <br />Floor Plan Notes <br />A2.0Window and Door Information <br />Schedules <br />REFERENCE EXTERIOR ELEVATIONS FOR TYPE & CONFIGURATION <br />PROVIDE TEMPERED GLASS AT LOCATIONS SHOWN ON EXTERIOR <br />WINDOW NOTES: <br />2. <br />ALL GLAZING IN DOORS TO BE TEMPERED PER CRC 308.4.1 <br />DOOR NOTES: <br />1. <br />1. <br />1. ALL GLASS AND GLAZING SHALL BE TESTED IN ACCORDANCE WITH <br />2. GLAZING IN DOORS AND FIXED GLAZED PANELS OF MORE THAN <br />GLASS NOTES: <br /> CPSC 16 CFR 1201 WHERE APPLICABLE FOR SAFETY (TEMPERED) <br /> GLAZING PER CRC R 308.3.1 GLAZING SHALL COMPLY WITH THE <br /> ELEVATIONS + PER SCHEDULE, AS REQUIRED PER CRC R308.4 <br /> 9 SQ FT TO BE CATEGORY II CLASSIFICATION PER CRC R308.3.1 <br />HT <br />6'-8" <br />- <br />FINISH REMARKS <br />YES YES TEMPERED <br />YES YES <br />- <br />WIDTH HEIGHT FINISH LITES EGRESS <br />4'-0"PAINT 8 <br />REMARKS NEW WALL TO BE CONSTRUCTED <br />EXISTING WALL TO REMAIN <br />REFER TO THE STRUCTURAL DRAWINGS FOR BEARING AND SHEAR WALLS. <br />ALL PLUMBING WALLS TO BE FRAMED WITH A 2 x 6 MIN STUDS <br />ALL OTHER WALLS ARE 2 x 4 FRAMED WALLS UNLESS NOTED OTHERWISE <br /> Plan Legend <br />6. <br />5. <br />PROVIDE R-15 INSULATION AT EXTERIOR WALLS PER TITLE 24 7. <br />8. <br />3. ALL ROOMS MEET VENTILATION AND LIGHTING REQUIREMENTS <br />OF CBC SECTIONS 1203.4 AND 1205 <br />4. DWELLING TO BE PROVIDED WITH COMFORT HEATING FACILITIES <br />CAPABLE OF MAINTAINING A ROOM TEMP OF 68 DEG F AT A POINT <br />OF 3 FT ABV THE FLOOR IN ALL HABITABLE ROOMS <br />PAINT <br />EXISTING SMOOTH STUCCO TO REMAIN <br />NEW DUAL GLAZED WOOD WINDOWS & DOORS- SIMILAR TO EX HOUSE <br />1. <br />2. <br />(2) WOOD CASMENT <br />ALL WINDOWS TO BE DUAL GLAZED WOOD. 3. <br />NO. <br />NO. <br />Floor Plan Keynotes <br />LITES <br />1 <br />NOT USED <br />U-FACTOR SHGC <br />U-FACTOR SHGC <br />Window and Door Notes <br />PROVIDE R-38 INSULATION AT ROOF RAFTERS PER TITLE 24 <br />IN TABLE R308.3.1(1) <br />TEXT CRITERIA FOR CATEGORY II UNLESS OTHERWISE INDICATED <br />6'-0" 6'-8"TEMPERED <br />PR SOLID DOORS <br />DUTCH DOOR 12'-8" <br />OF TRAVEL NOT LESS THAN 36" <br />LANDINGS AT DOORS SHALL HAVE A LENGTH MEASURED IN DIRECTION <br />4. Openings <br />4b <br />4a <br />3a <br />3. Interior <br />4c <br />2. Exterior <br />2a <br />2 x 6 WOOD STUD AT NEW PLUMBING WALL <br />16" x 16" SHAMPOO NICHE <br />5. Appliances <br />NOT OVER 44" ABOVE THE FLOOR. <br />5.7 SQ.FT. - A MIN. CLEAR 24" HEIGHT AND 20" WIDTH, AND A SILL HEIGHT <br />MEETING ALL OF THE FOLLOWING: AN OPENABLE AREA NOT LESS THAN <br />BEDROOM TO HAVE MIN. OF ONE OPENABLE ESCAPE WINDOW OR DOOR <br />LANDING TO NOT BE MORE THAN 1 1/2" BELOW THRESHOLD OF THE <br />DOORWAY - OR 7 3/4" BELOW THE THRESHOLD ON THE EXTERIOR SIDE <br />IF DOOR DOES NOT SWING OVER THE LANDING OR STEPS <br />HOT MOPPED SHOWER PAN AND CURB WITH MUDSET (PORTLAND CEMENT) TILE <br />FLOOR + WALLS TO CEILING (PER CRC 702.4.2) - PROVIDE SHOWER HEAD AT +78"AFF <br />7. Plumbing <br />7d <br />7e <br />7c <br />PROVIDE FRAMELESS 1/4" TEMPERED SHOWER DOOR TO MIN 72" AFF <br />GLASS TO HAVE CATEGORY II CLASSIFICATION PER CBC CHAPTER 24 <br /> AND UBC STD 24-2 - LOCATE VALVES AND HEAD PER CPC 408.9 - SYMBOL ( ) <br />WATER CLOSET WITH A CLEAR FLOOR SPACE OF 15" ON EACH SIDE OF TOILET, <br />AS MEASURED FROM THE CENTERLINE OF THE TOILET, AND 24" CLEAR IN FRONT <br />7a <br />WASHER & DRYER LOCATION - RECESS EXISTING HOT AND COLD WATER <br />CONNECTIONS, PROVIDE G.I. PAN UNDER WASHER WITH DRAIN TO <br />WASTE SYSTEM - DRYER EXHAUST DUCT (4" DIA) TO OUTSIDE W/ <br />BACK-DRAFT DAMPER. EXHAUST LENGTH LIMITED TO 14FT WITH <br />7b <br />6. Cabinetry <br />KITCHEN SINK W/ GARBAGE DISPOSAL - VERIFY DIMS W/ MANUF SPECS <br />ELECTRIC RANGE - VERIFY DIMS W/ MANUF SPECS <br />REFRIGERATOR/ FREEZER - TIGHT TOLERANCE BETWEEN END PANELS <br /> VERIFY DIMS W/ MANUF SPECS <br />7f <br />24" PULLMAN - COUNTER AT 34"-36" WITH 6" HIGH SPLASH + MIRROR ABV <br /> 2 ELBOWS PER CMC 504.4.2 <br />PER CODE - TOILET TO BE LOW FLUSH (1.28 GAL/ FLUSH) <br />3b <br />3c FURR OUT EXTERIOR WALL TO BEYOND EX FOUNDATION CURB <br />NEW CONCRETE LANDING SLOPE 1/4" PER FOOT AWAY FROM STRUCTURE2b <br />EXISTING COVERED PATIO <br />Plans <br />SCALE: 1/4" = 1'Demolition Plan 3 <br />Ex Garden Shed <br />Demolition <br />MEDICINE CABINET <br />EXISTING WALL OR ITEM TO BE REMOVED <br />W <br />NS <br />E <br />Existing 2-car Garage <br />YES <br />6'-8"PAINT <br />6'-8"PAINT2'-8" 6'-8"PAINT2'-8" <br />6'-8"PAINT <br />6'-8"PAINT3'-0"SOLID CORE <br />POCKET DOOR <br />POCKET DOOR <br />FRENCH DOOR <br />PAINT <br />- <br />YES <br />- <br />YES 1 TEMPERED <br />- <br />5'-4" <br />EX SKYLIGHT <br />EX SKYLIGHT EX SKYLIGHT <br />REMOVE <br />EX SKYLIGHT <br />Ex Patio Cover <br />Bedroom 2 <br />Living Area <br />Bath <br />closet <br />NEW 100 AMP ELECTRICAL SUBPANEL - CONTRACTOR TO VERIFY LOCATION 9a <br />9. Electrical <br />10. Specialties <br />10a <br />8. Mechanical <br />8a <br />8b <br />NEW CENTRAL SPLIT HEAT PUMP - 16 SEER PER TITLE 24 <br />5d <br />5c BUILT-IN DISHWASHER W/ GFCI OUTLET - VERIFY DIMS W/ MANUF SPECS <br />MICROWAVE / RANGE HOOD - VERIFY DIMS W/ MANUF SPECS <br /> RANGE HOOD - MIN 100 CFM - DUCT PER ASHRAE 62.2 TABLE 7.1 AND TABLE 5.3 <br /> FOR PRESCRIPTIVE DUCT SIZING WHERE APPLICABLE - MAX SONE RATING 3.0 <br />SEE MECH NOTES SHEET A2.2 FOR ADDITIONAL REQUIREMENTS <br />* REFER TO ELECTRICAL PLAN FOR BATH + KITCHEN VENTILATION REQUIREMENTS <br />10b <br />5b <br />5a <br />CLOSET POLE AND SHELF - LAYOUT TBD BY OWNER6a <br /> WATER HEATER, RHEEM PROPH40 T2 RH37515 (40 gal, JA13) PER TITLE 24 <br />15'-0"5'-0"9'-7"+ 5'-8" <br />10'-10" <br />4'-1"5'-6" <br />5'-7"5'-2"4'-11" <br />4a <br />4b <br />4c <br />4a <br />4b <br />4'-0" <br />4a 4b <br />5a 6b <br />7a <br />7b <br />7c <br />7d7e <br />7f <br />6a <br />5d 5c5b 8a <br />8b <br />Existing <br />Storage <br />Existing 2-car Garage <br />3a <br />3c <br />3c 3c <br />Floor <br />0.30 0.23 <br />0.30 0.23 <br />2c <br />PROVIDE 2X8 BLOCKING REINFORCEMENT IN BATHROOM FROM 32" TO 39.5" <br />ABOVE FINISHED FLOOR ON ONE SIDE OF WATER CLOSET AND BACK WALL, <br />AND AT SHOWER WALLS (DASHED LINE ON PLANS) PER CRC R327.1.1 <br />1-HR FIRE RESISITANCE RATED WALL WITH 7/8" STUCCO AT EXTERIOR & <br /> 5/8" TYPE 'X' GYPSUM BOARD FROM SLAB TO UNDERSIDE OF SHEATHING <br />2c 2c 2c <br />_ _ _ _ _ _ _ _ <br />1 Hour Rated Wall Detail 2 <br />EX 7/8" EXT PLASTER <br /> ROOF INSULATION PER T24 <br />5/8" TYPE X GYPSUM BD <br />FROM SLAB TO UNDERSIDE <br />EX 2x4 STUD <br />WALL INSULATION PER T24 <br />RADIANT BARRIER <br />CLASS A ROOF <br />UNDERSIDE OF <br />OF ROOF SHEATHING <br />7' <br />- <br />1 <br />1 <br />" <br />15 <br />' <br />- <br />1 <br />0 <br />" <br />18 <br />' <br />- <br />2 <br />" <br /> AT INTERIOR - TYPICAL AT WEST WALL <br />REMOVE REMOVE <br />to be removed <br />Existing <br />Storage <br />REMOVE <br />EX TOILET <br />+ SINK <br />EX PLYWOOD <br />METAL COPING <br />5/8" TYPE X GYPSUM BD <br />FROM UNDERSIDE OF <br />ROOF SHEATHING TO <br />PARAPET TOP PLATE <br />PER PLAN <br />EX TOP PLATE <br />1/2:12 <br />ROOF DECK <br />MOISTURE RESISTANT <br />WITH GALVANIZED <br />SHEET METAL <br />GALVANIZED SHEET <br />0.30 0.23 <br />0.30 0.23 <br />4'-11" <br />Bedroom 1 <br />Laundry <br />Kitchen <br />3'-10" <br />5' <br />- <br />8 <br />" <br />3' <br />- <br />2 <br />" <br />11 <br />' <br />- <br />1 <br />0 <br />" <br />2'-10" <br />8' <br />- <br />6 <br />" <br />6b <br />SHELVING TBD6b <br />2b <br />2b <br />2b <br />3b <br />3c <br />3c <br />3c <br />6'-8"PAINT2'-8" PAINT <br />6'-8"PAINT <br />6'-8"PAINT6'-0"CLOSET BY PASS <br />SOLID CORE <br />POCKET DOOR <br />6'-8"3'-4"PAINT YES YES <br />2'-10" <br />2'-8" <br />30" <br />6b <br />6a <br />3' <br />- <br />1 <br />" <br />2' <br />- <br />7 <br />" <br />1' <br />- <br />9 <br />" <br />10 <br />' <br />- <br />1 <br />" <br />2'-6" 4'-0"PAINT 8WOOD CASMENT 0.30 0.23_ <br />8c A/C CONDENSER <br />8c <br />9a <br />5' <br />- <br />2 <br />" <br />LOUVERED TOP + BOTTOM <br />PER WH MANUF SPECS <br />9'-10" <br />A/C <br />3' <br />- <br />0 <br />" <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />REFER TO SHEET A3.0, DETAIL 7 FOR ALL AGING IN PLACE REQUIREMENTS <br />7' <br />- <br />1 <br />1 <br />" <br />1