FACILITYGROUND <br />120/240 VAC <br />SINGLE PHASE <br />SERVICE EXISTING 125A <br />MAIN BREAKER -END FED <br />EXISTING 125A <br />MAIN PANEL <br />225A BUS <br />M <br />TESLA <br />BACKUP <br />SWITCH <br />METER NUMBER: SCE 222013-126624 <br />B <br />• POINT OF INTERCONNECTION: CEC 2025 705.12(B)(2), LOAD BREAKER AT OPPOSITE END OF BUSBAR <br />• <br />EQUIPMENT CHARACTERISTICS INCLUDED IN SPEC SHEETS <br />• NOTE: COMBINED SYSTEM BACKFEED(E+N) = 100.0A USED FOR INTERCONNECTION CALCULATIONS <br />(N)TESLA REMOTE METER <br />(1)SOLAR PV CURRENT <br />TRANSFORMER <br />J-BOX <br />EE <br />Existing 32 Enphase Energy: M215-60-2LL-S2X-IG Microinverters <br />32 Existing Hanwha Q CELLS: Q.PR0 BFR-G4 265 Modules <br />E <br />Existing <br />AC DISCONNECT <br />E <br />Enphase Combiner Panel <br />Existing <br />B <br />(N) LOCKABLE <br />BLADE TYPE <br />AC DISCONNECT <br />SQUARE D <br />DU222RB <br />3R, 60A , 2P <br />120/240VAC <br />1 1 <br />ENERGY STORAGE: <br />TESLA:POWERWALL 3 1707000-XX-Y <br />(N) IMO PE69-3020, <br />DISCONNECT <br />SWITCH, 3P, 16A <br />(N)-(1)-60A ESS <br />BREAKER <br />(E)-(1)-40A PV <br />BREAKER <br />100A 2 <br />NEW 125 A LOAD CENTER <br />M <br />Existing <br />Sunrun Meter <br />E <br />CONDUIT SCHEDULE <br />TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT <br />1 Battery Output (2) 6 AWG <br />THHN/THWN-2 <br />(1) 6 AWG <br />THHN/THWN-2 10 AWG THHN/THWN-2 3/4" EMT <br />2 Load Center Output (2) 3 AWG <br />THHN/THWN-2 <br />(1) 3 AWG <br />THHN/THWN-2 8 AWG THHN/THWN-2 1" EMT <br />E Existing System <br />PAGE <br />REV: A 4/23/2026 <br />MELVIN SHANKS <br />2325 W FLORA ST SANTA ANA <br />CA 92704 <br />PROJECT NUMBER: <br /> 109R-325SHAN2 PR-3005067352 <br />SHEET <br />DESIGNER: <br />KAVIPRIYA K <br />CUSTOMER RESIDENCE: <br />TEL. 7145498540 <br />APN: 412-313-04 <br />(415) 580-6920 ex3 <br />PV-4.0 <br />#ESTAMP#SSTAMP <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />ELECTRICAL <br />General Notes: <br />• CITY REQUIRES TWO SOURCES OF GROUND - UFER, TWO GROUNDS RODS OR <br />COLD WATER GAS BOND <br />• INSTALL THE BACKED UP LOAD CONDUCTORS AND THE MICROGRID <br />INTERCONNECTION DEVICE BREAKER CONDUCTORS IN TWO SEPARATE <br />CONDUITS. <br />IF THE RELOCATED LOADS EXTEND MORE THAN 6 FEET, AFCI <br />PROTECTION APPLIES PER 2019 CEC 210.12 <br />ANY MULTIWIRE BRANCH CIRCUITS RELOCATED ARE TO BE IDENTIFIED, GROUPED, <br />AND EQUIPPED WITH A 2-POLE OCPD BREAKER PER CEC 210.4(B,D).