My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2325 W Flora St - Plan
PBA
>
Building
>
ProjectDox
>
F
>
Flora St
>
2325 W Flora St
>
2325 W Flora St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2026 5:00:11 AM
Creation date
6/9/2026 5:00:06 AM
Metadata
Fields
Template:
Plan
Permit Number
20188697
Full Address
2325 W Flora St
Street Number
2325
Street Direction
W
Street Name
Flora
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
BACKUP LOADS <br />LOAD BREAKER <br />RATING (AMPS)LABEL DEMAND <br />LOAD <br />1 20A-1P DISHWASHER 1500 W <br />2 20A-1P DISP 1500 W <br />3 20A-1P MASTER BATH 1500 W <br />4 20A-1P KITCHEN 1500 W <br />5 20A-1P KITCHEN 1500 W <br />6 20A-1P HALLWAY GFCI 1500 W <br />7 20A-1P CONV 1500 W <br />8 20A-1P LIGHTING & RECEPTACLE 1500 W <br />9 20A-1P ENTRY BATH 1500 W <br />10 15A-1P LIGHTS 1500 W <br />11 15A-1P LIGHTS 1500 W <br />12 20A-1P UPSTAIR LIGHTS 1500 W <br />13 20A-1P UPSTAIR PLUGS 1500 W <br />14 20A-1P WASHER 1500 W <br />15 20A-1P FAU 1920 W <br />16 50A-2P RANGE 9600 W <br />17 30A-2P DRYER 5760 W <br />18 40A-2P A/C 7680 W <br />19 15A-2P TRM 2880 W <br />PAGE <br />REV: A 4/23/2026 <br />MELVIN SHANKS <br />2325 W FLORA ST SANTA ANA <br />CA 92704 <br />PROJECT NUMBER: <br /> 109R-325SHAN2 PR-3005067352 <br />SHEET <br />DESIGNER: <br />KAVIPRIYA K <br />CUSTOMER RESIDENCE: <br />TEL. 7145498540 <br />APN: 412-313-04 <br />(415) 580-6920 ex3 <br />PV-4.1 <br />#ESTAMP#SSTAMP <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />ELECTRICAL CALCS <br />Wire Calculations <br />Wire ampacity calculated from CEC 310.16/310.17 as appropriate with ambient temperature calculations from CEC <br />310.15(B)(1)(1) and raceway fill adjustments from CEC 310.15(C)(1). Conduit on the roof shall be installed no less <br />than 1" above the roof deck. PV Circuit conductor ampacity is constrained using the 75°C column with the <br />continuous duty uprating or the 90°C column with the relevant ambient temperature and raceway fill adjustments <br />without the continuous duty uprating per 690.8(B), whichever is the lower value will govern conductor sizing. <br />Non-PV Circuit Conductors use the ampacity in the 75°C column or the 90°C column with the relevant ambient <br />temperature and raceway fill adjustments, whichever is less (110.14(C) & 310.15(A)(2)). The rating of the <br />conductor after adjustments shall be greater than, or equal to, the continuous duty uprated current. <br />Calc Ex: Wire Ampacity x Ambient Temp. Corr. Factor x Conduit Fill Adj. Factor >= Output Current <br />•Tag 1: Battery Output: 6 AWG rated 65A as per 75°C, 68.25A as per 90°C with adjustements >= 60.0A <br />•Tag 2: Load Center Output: 3 AWG rated 100A as per 75°C, 104.65A as per 90°C with adjustements >= 100.0A <br />Allowable Backfeed: <br /> Allowable Backfeed = (Busbar Rating) x 1.2 - (Main Breaker Rating) = <br /> 225 A * 1.2 - 125 A = 145.0 A <br />100 A ≤ 145.0 A → Interconnection <br /> Meets CEC 2025 705.12(B)(2) Requirements
The URL can be used to link to this page
Your browser does not support the video tag.