Laserfiche WebLink
SCOPE OF WORK <br />(E) STRUCTURES PER <br />PLAN <br />(N) ADU <br />1 SCALE: 1/8"=1'-0" <br />(N) PLOT PLAN <br />(E) SINGLE FAMILY <br />DWELLING <br />1,280 SQ.FT. <br />N.I.C. <br />(E) 2-CAR GARAGE <br />418 SQ.FT. <br />N.I.C. <br />(N) ADDITION TO <br />CONVERT INTO AND <br />A.D.U. <br />494 SQ.FT. <br />(E) UNIT TO <br />CONVERT INTO AN <br />A.D.U. <br />291SQ.FT. <br />(N)ACCESSORY <br />DWELLING UNIT <br />785 SQ.FT. <br />5'-4" <br />3' <br />- <br />1 <br /> <br />1 <br />/ <br />2 <br />" <br />24 <br />' <br />- <br />7 <br />" <br />10 <br />' <br />- <br />1 <br />1 <br />" <br />18 <br />' <br />- <br />1 <br />0 <br />" <br />21 <br />' <br />- <br />7 <br />" <br />S Western Ave, Santa Ana, CA <br />GA <br />S <br />WM <br />(E) <br />3/4" Water <br />meter to <br />remain <br />(E) PORCH <br />70 SQ.FT. <br />N.I.C. <br />PROPERTY LINE 60.0' <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br /> <br /> <br />1 <br />0 <br />9 <br />. <br />0 <br />' <br />60'-0" <br />10 <br />9 <br />' <br />- <br />0 <br />" <br />ELEC. <br />(E) Gas <br />meter <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br /> <br /> <br />1 <br />0 <br />9 <br />. <br />0 <br />' <br />(E) <br />LANDSCAPE <br />664 SQ.FT. <br />(E <br />) <br />LA <br />N <br />D <br />S <br />C <br />A <br />P <br />E <br />13 <br />0 <br /> <br />S <br />Q <br />. <br />F <br />T <br />. <br />(E) <br />LANDSCAPE <br />129 SQ.FT. <br />(E) <br />CONC. <br />DRIVEWAY <br />1,336 SQ.FT. <br />(E) <br />CONC. <br />SLAB <br />328 SQ.FT. <br />(E) <br />LANDSCAPE <br />630 SQ.FT. <br />(E) <br />PAVER <br />336 SQ.FT. <br />(E) <br />CONC. <br />SLAB <br />369 SQ.FT. <br />12 <br />' <br />- <br />9 <br /> <br />1 <br />/ <br />2 <br />" <br />6' <br />- <br />1 <br />1 <br />" <br />10 <br />' <br />- <br />3 <br /> <br />1 <br />/ <br />2 <br />" <br />6'-4"27'-2"14'-1 1/2"12'-4 1/2" <br />21 <br />' <br />- <br />7 <br />" <br />18 <br />' <br />- <br />1 <br />0 <br />" <br />35 <br />' <br />- <br />6 <br />" <br />22 <br />' <br />- <br />1 <br />0 <br />" <br />10 <br />' <br />- <br />3 <br /> <br />1 <br />/ <br />2 <br />" <br />(E) <br />LANDSCAPE <br />55 SQ.FT. <br />(E) DRIVEWAY <br />APPROACH <br />(E) <br />SIDEWALK <br />(E) <br />PARKWAY <br />(N)5% <br />(N)5% <br />(N)2% <br />(N)5% <br />(N)2% <br />(E <br />) <br />5 <br />% <br />(E <br />) <br />5 <br />% <br />(E <br />) <br />5 <br />% <br />(E)1% <br />(E <br />) <br />1 <br />% <br />(E <br />) <br />1 <br />% <br />(E) 6' BLOCK WALL <br />(E) 6' BLOCK WALL <br />(E) 3' BLOCK WALL <br />(E) 6' STEEL CHAIN <br />LINK FENCE <br />(E <br />) <br />1 <br />% <br />(E <br />) <br />1 <br />% <br />(E <br />) <br />2 <br />% <br />(E <br />) <br />2 <br />% <br />(E <br />) <br />2 <br />% <br />(E <br />) <br />1 <br />% <br />2% <br />(N) <br />tankless <br />W/H <br />(E) public utility easement <br />(P.U.E.) <br />ELEC. POLE <br />(N) minisplit <br />Fujitsu <br />AOU24RLXFZ <br />over evel <br />concrete <br />pad extending <br />not less than 3 <br />inches above <br />the adjoining <br />ground. [CMC <br />1105.2]. <br />(E) 100 Amp <br />elec. panel <br />3'-0" <br />4' <br />- <br />0 <br />" <br />utilities will be undergrounded per SAMC 41-626 <br />22'-2"19'-11"12'-7" <br />6'-5 1/2" <br />10 <br />' <br />- <br />1 <br />1 <br />" <br />PROPERTY LINE 60.0'PL <br />PL <br />PL <br />PL <br />PL <br />4'-4" <br />5'-4" <br />eave dist. <br />9' <br />- <br />3 <br /> <br />1 <br />/ <br />2 <br />" <br />ea <br />v <br />e <br /> <br />d <br />i <br />s <br />t <br />a <br />n <br />c <br />e <br />1'-0" <br />11'-7" <br />eave distance <br />1'-0" <br />(E) UNIT CONVERTED <br />TO A PART OF ADU <br />(E) STRUCTURES PER <br />PLAN <br />(N) ADDITION TO ADU <br />= PROPERTY LINEPL <br />OR <br />T <br />H <br />NS <br />W <br />E <br />1 <br />Future <br />HPWH <br />ready space <br />(see detail <br />HP/01-A1.1) <br />OF <br />SHEET NO. <br />DATE ISSUED DRAWN BY <br />CHECKED BY SCALE <br />PRINT:REVISION: <br />SH <br />E <br />E <br />T <br /> <br /> <br />N <br />A <br />M <br />E <br />: <br />THESE DRAWINGS, DESIGN AND SPECIFICATIONS ARE THE PROPERTY AND COPY RIGHT OF YOLANDA CASTRO AND/OR C+P DESIGN CONSTULTANTS AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH YOLANDA CASTRO. WRITTEN DIMENSIONS SHALL TAKE REFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE, ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF YOLANDA CASTRO TO THE COMMENCEMENT OF ANY WORK <br />PR <br />O <br />J <br />E <br />C <br />T <br />: <br />OW <br />N <br />E <br />R <br />: <br />AD <br />D <br />R <br />E <br />S <br />S <br />: <br />Y.C. <br />C+P <br />25 <br />C <br />P <br />0 <br />0 <br />6 <br />1 <br />AS SHOWN <br />5/3/2025 <br />STAMP APPROVAL <br />11-05-2025 <br />A. <br />P <br />. <br />N <br />. <br />40 <br />6 <br /> <br />S <br /> <br />W <br />e <br />s <br />t <br />e <br />r <br />n <br /> <br />A <br />v <br />e <br />, <br /> <br />U <br />n <br />i <br />t <br /> <br /># <br />2 <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />NE <br />W <br /> <br />A <br />C <br />C <br />E <br />S <br />S <br />O <br />R <br />Y <br /> <br />D <br />W <br />E <br />L <br />L <br />I <br />N <br />G <br /> <br />U <br />N <br />I <br />T <br />Ma <br />t <br />i <br />a <br />s <br /> <br />M <br />i <br />r <br />a <br />n <br />d <br />a <br />00 <br />7 <br />- <br />2 <br />2 <br />3 <br />- <br />0 <br />6 <br />12-22-2025 <br />2 01-20-2026 02/27/2026 <br />01-A1.0 <br />(N <br />) <br /> <br /> <br />P <br />L <br />O <br />T <br /> <br />P <br />L <br />A <br />N