SYM.WIDTH TYPE MANU.MATERIAL <br />1 S.C.3'-0"1 3 4" <br />2 <br />3 <br />THICKNESS <br />H.C. <br />6'-8" <br />HEIGHT <br />6'-8" <br />DOOR SCHEDULE <br />WOOD <br />QTY. <br />1 3 8" <br />6'-8" <br />4 6'-8" <br />5 6'-0"6'-8" <br />S.C.-SOLID CORE <br />H.C.-HOLLOW CORE <br />F.R.-FRENCH DOOR <br />F.L.-FOLDING DOOR <br />S.L.-SLIDING DOOR <br />P.O.-POCKET DOOR <br />1 <br />1 <br />1 <br />2 <br />4 <br />2'-6"H.C.WOOD 1 3 8" <br />WOODCLOSET <br />TYPE MANU.GLAZING REMARKS <br />1 VINYL SL5'-0" <br />WINDOW SCHEDULE <br />3 <br />CLEARS.L. <br />4 VINYL SLS.L. <br />U-FACTOR1 SHGC2 <br />1 BTU/H FT2.*F <br />2 SOLAR HEAT GAIN COEFFICIENT <br />WIDTH HEIGHT <br />4'-0" <br />SYM. <br />SIZE <br />2'-0"2'-0" <br />QTY. <br />2 <br />1 <br />VINYL SLS.L.2'-0"4'-0" <br />2 VINYL SL4'-0"CLEARS.L.4'-0"1 DUAL GLAZED <br />5 VINYL SLS.L.5'-0"4'-0"2 <br />GLAZING @ WINDOWS <br />1. ALL NEW WINDOWS SHALL BE DUAL GLAZED & 1-PANE TEMPERED. <br />2. THE LOAD RESISTANCE OF GLASS UNDER UNIFORM LOAD SHALL BE DETERMINED IN ACCORDANCE WITH ASTM E1300. <br />DUAL GLAZED <br />(E) 1 <br />CLEAR DUAL GLAZED <br />CLEAR <br />CLEAR DUAL GLAZED <br />DUAL GLAZED <br />S.L. <br />d) FIBERGLASS SHOWER <br />c) ON-SITE BUILT-UP SHOWERb) SHOWER ENCLOSUREa) SHOWER ENCLOSUR <br />(PLAN VIEW) <br />e) BASE FOR TILE <br />SHOWER CONSTRUCTION <br />1.19 0.23 <br />0.30 0.23 <br />S.L. <br />(N) FLOOR PLAN2SCALE: 3/16"=1'-0" OR <br />T <br />H <br />NS <br />W <br />A.D.U. <br />0.30 0.23 <br />0.30 0.23 <br />0.30 0.23 <br />4'-0" <br />2'-8" <br />PATIO WOOD/ <br />TEMP. GLASS <br />11'-3" <br />11 <br />' <br />- <br />0 <br />" <br />11 <br />' <br />- <br />0 <br />" <br />W/ <br />D <br />KING 76X80" <br />3' <br />- <br />0 <br />" <br />7' <br />- <br />7 <br />" <br />TWIN 39X80TWIN 39X80 <br />6'-0"3' <br />- <br />0 <br />" <br />21'-0" <br />11 <br />' <br />- <br />1 <br />1 <br /> <br />1 <br />/ <br />2 <br />" <br />3' <br />- <br />2 <br />" <br />3'-6" <br />3' <br />- <br />0 <br />" <br />(E) <br />KITCHEN <br />Ch=8'-0" <br />(E) <br />LIVING AREA <br />Ch=8'-0" <br />(N) <br />BEDROOM #1 <br />h=8'-0" <br />(N) <br />BEDROOM #2 <br />Ch=8'-0" <br />(N) <br />HALLWAY <br />h=8'-0" <br />(N) <br />BATH <br />ch=8'-0" <br />shower <br />closet <br />closet <br />(N) <br />DEN <br />Ch=8'-0" <br />(E) <br />BREEZEWAY <br />(E) wall to be converted into <br />1-hr fire rated wall (separation <br />garage-home) to remain <br />(E) wall to be <br />demolished for <br />(N) 5x4 window <br />(E) wall to be <br />demolished <br />(E) wall to be <br />demolished <br />(E) <br />BEDROOM #3 <br />Ch=8'-0' <br />(E) <br />BATH <br />Ch=8'-0' <br />(E) <br />BATH <br />Ch=8'-0' <br />(E) <br />KITCHEN <br />Ch=8'-0' <br />(E) <br />BEDROOM #2 <br />Ch=8'-0' <br />(E) <br />BEDROOM #1 <br />Ch=8'-0' <br />(E) <br />LIVING ROOM <br />Ch=8'-0' <br />(E) <br />LIVING ROOM <br />Ch=8'-0' <br />(E) <br />2-CAR GARAGE <br />Ch=varies <br />(E) wall to be <br />partial demolished <br />and remove <br />window for a (N) <br />entrance door <br />18 <br />' <br />- <br />5 <br />" <br />(E) <br />BREEZEWAY <br />3' <br />- <br />1 <br />0 <br />" <br />2' <br />- <br />0 <br />" <br />5' <br />- <br />5 <br />" <br />3' <br />- <br />1 <br />1 <br />" <br />2' <br />- <br />0 <br />" <br />5' <br />- <br />5 <br />" <br />2' <br />- <br />1 <br />0 <br />" <br />3' <br />- <br />0 <br />" <br />2' <br />- <br />0 <br />" <br />5' <br />- <br />5 <br />" <br />11 <br />' <br />- <br />4 <br />" <br />11 <br />' <br />- <br />4 <br />" <br />13 <br />' <br />- <br />3 <br />" <br />8'-1"3'-0"11'-1"6'-11"4'-7"2'-5"2'-0"4'-0" <br />11'-7"8'-8"4'-4"1'-6"2'-2"1'-6"1'-9"2'-10"1'-0"1'-6"5'-4" <br />11 <br />" <br />8' <br />- <br />0 <br />" <br />9' <br />- <br />6 <br />" <br />11 <br />' <br />- <br />4 <br />" <br />2' <br />- <br />0 <br />" <br />2' <br />- <br />0 <br />" <br />10 <br />' <br />- <br />2 <br />" <br />2' <br />- <br />6 <br />" <br />7' <br />- <br />1 <br />1 <br />" <br />3' <br />- <br />2 <br />" <br />5' <br />- <br />3 <br />" <br />2' <br />- <br />0 <br />" <br />5' <br />- <br />6 <br />" <br />1 <br />233 <br />5 <br />5 <br />4 <br />2 <br />3 <br />4 <br />4 <br />5 <br />5 <br />1 <br />EXISTING WALLS TO BE DEMOLISHED <br />EXISTING WINDOW TO BE REPLACED AND/OR <br />REMOVED <br />EXISTING DOOR TO BE REPLACED AND/OR <br />REMOVED <br />(E) 2X4 STUD WALL - TO 1 HR FIRE RATED <br />(E) & (N) FLOOR PLAN LEGEND <br />EXISTING 2X4 STUD WALL <br />NEW 2X4 STUD WALL <br />ATTIC ACCESS 30"x30" w/min 30" head-room <br />W/APPROVED GASKET AT PERIMETER OF <br />ACCESS OPENING <br />(N) 2X4 STUD WALL - 1 HR FIRE RATED <br />NEW 2X6 STUD WALL - WET WALL <br />INTERCONNECTED HARD-WIRED CARBON <br />MONOXIDE ALARM WITH BATTERY BACKUP <br />OUTSIDE OF EACH BEDROOM, AND <br />OCCUPIABLE LEVEL IF DWELLING UNIT. <br />(R315) <br />INTERCONNECTED HARD-WIRED “SMOKE <br />ALARM” WITH BATTERY BACKUP IN EACH <br />SLEEPING ROOM, IMMEDIATE VICINITY OF <br />THE BEDROOMS, EACH ADDITIONAL STORY <br />OF DWELLING, AND NOT LESS THAN 3-FT <br />FROM THE BATHROOM THAT CONTAINS <br />BATHTUB OR SHOWER. (R314) <br />SD <br />1'-6"1'-0"8'-8"1'-0"1'-3"2'-11"2'-1 1/2"2'-0"6'-8 1/2" <br />6' <br />- <br />2 <br />" <br />2' <br />- <br />0 <br />" <br />3' <br />- <br />3 <br />" <br />3' <br />- <br />5 <br />" <br />2' <br />- <br />6 <br />" <br />5' <br />- <br />1 <br />1 <br />" <br />3"2'-0"3'-10"2'-6"5'-4" <br />7" <br />1' <br />- <br />0 <br />" <br />1' <br />- <br />7 <br />" <br />1' <br />- <br />1 <br />1 <br />" <br />6" <br />7' <br />- <br />4 <br />" <br />11'-8"2'-3"5'-4"3'-5"18'-5" <br />41'-1" <br />23 <br />' <br />- <br />3 <br />" <br />70 <br />' <br />- <br />3 <br />" <br />15 <br />' <br />- <br />1 <br />1 <br />" <br />42'-1" <br />E <br />(E) FLOOR PLAN1SCALE: 3/16"=1'-0" OR <br />T <br />H <br />NS <br />W <br />A.D.U. <br />E <br />WOOD/ <br />TEMP. GLASS <br />1 3 4" <br />1 3 8" <br />1 2" MAX. <br />AT 1:2 SLOPE <br />2 <br />1 <br />14" <br />MAX. <br />DOOR <br />7 3 <br />4" MAX <br />NOTES: <br />1.A MIN OF 1" IF SPACE SHALL BE PROVIDED <br />BETWEEN THE INSULATION AND THE ROOF <br />SHEATHING AND THE LOCATION OF VENTS <br />(CRC R806.3) <br />2.WALL COVERINGS IN SHOWERS AND TUBS WITH <br />SHOWERHEADS SHALL BE CEMENT PLASTER , <br />TILE, OR EQUAL TO 6 FEET (72") ABOVE DRAIN. <br />ENCLOSURES MUST BE OF APPROVED SAFETY <br />GLAZING AND DOORS (22” MIN. WIDTH) MUST <br />SWING OUT OF SHOWERS. <br />3.WINDOWS IN ENCLOSURE WALLS SHALL BE <br />LABELED SAFETY GLAZING WHEN LESS THAN 60" <br />ABOVE THE DRAIN.” CRC R307.2. <br />4.GLAZING IN ENCLOSURE FOR OR WALLS FACING <br />HOT TUBS, BATHTUBS, SHOWERS, WHIRL-POOLS, <br />SAUNAS, STEAM ROOMS WHERE THE BOTTOM <br />EDGE OF THE GLAZING IS LESS THAN 60” ABOVE <br />THE ANY STANDING SURFACE <br />AGING IN PLACE/FALL PREVENTION NOTES: <br />W <br />A-3 <br />E <br />A-3 <br />N <br />A-3 <br />S <br />A-3 <br />4" CLOTHES DRYER <br />MOISTURE <br />EXHAUST DUCT TO ROOF <br />W/BACK-DRAFT DAMPER <br />island <br />(N) minisplit Fujitsu AOU24RLXFZ <br />over level concrete pad extending <br />not less than 3 inches above the <br />adjoining ground. <br />[CMC 1105.2]. <br />(E) Wall to be converted <br />1-hr fire rated for units <br />separation with 5 8" type <br />"X" Gyp. Bd. see detail <br />B /01-A1.3 <br />RIDGID PIPE NOT TO <br />EXCEED <br />2" THROUGH DRYER <br />BOX <br />SEE DETAIL <br />DRYERBOX <br />DRYERBOX DETAIL <br />FLEX <br />TRANSITION <br />HOSE <br />2" <br />NOTE: DRYERBOX MODEL 425 CAN <br />BE MOUNTED UPSIDE DOWN FOR <br />THROUGH FLOOR VENTING <br />APPLICATIONS <br />BOTTOM OF DRYERBOX <br />SHOULD BE 4 1/2" <br />ABOVE CENTER OF DRYER <br />EXHAUST <br />Model 466 Dryerjack <br />(Optional) <br />www.dyerjack.com <br />1'-218" <br />DRYER BOX MODEL 425 TO ROOF JACK @ 2X6 WALL <br />The clothes dryer exhaust <br />duct shall be a minimum <br />4-inch diameter, be made of <br />rigid metal, have a smooth <br />interior surface, vent to <br />outside air (at least 3 ft away <br />from any building opening), <br />and have a maximum duct <br />length of 14 feet. The <br />maximum duct length <br />includes two 90-degree <br />elbows. [CMC 504.4] <br />NOTES FOR FUTURE ELEC. APPLIANCES <br />Cooktop is proposed as gas or propane: <br />A dedicated 240-volt branch circuit wiring shall be installed within 3 feet from the <br />cooktop and accessible to the cooktop with no obstructions. The branch circuit <br />conductors shall be rated at 50 amps minimum. The blank cover shall be identified <br />as "240V ready." All electrical components shall be installed in accordance with <br />the California Electrical Code. <br />The main electrical service panel shall have a reserved space to allow for the <br />installation of a double pole circuit breaker for a future electric cooktop installation. <br />The reserved space shall be permanently marked as "For Future 240V use." <br />Clothes dryer is proposed as gas or propane: <br />A dedicated 240-volt branch circuit wiring shall be installed within 3 feet from the <br />clothes dryer location and accessible to the clothes dryer location with no <br />obstructions. The branch circuit conductors shall be rated at 30 amps minimum. <br />The blank cover shall be identified as "240V ready." All electrical components shall <br />be installed in accordance with the California Electrical Code. <br />The main electrical service panel shall have a reserved space to allow for the <br />installation of a double pole circuit breaker for a future electric clothes dryer <br />installation. The reserved space shall be permanently marked as "For Future 240V <br />use." <br />60 CMF MIN. EXHAUST FAN SHALL BE <br />ENERGY STAR RATED, EXHAUSTED <br />DIRECTLY TO OUTSIDE, W/ HUMIDITY <br />SENSOR CONTROL <br />3'-0" <br />4' <br />- <br />0 <br />" <br />1' <br />- <br />6 <br />" <br />2' <br />- <br />0 <br />" <br />6' <br />- <br />5 <br /> <br />1 <br />/ <br />2 <br />" <br />3' <br />- <br />1 <br /> <br />1 <br />/ <br />2 <br />" <br />ELEC. <br />ELEC. <br />(E) 100 AMP <br />ELEC. PANEL <br />(E) 100 AMP <br />ELEC. PANEL <br />BATHROOMS, WATER CLOSET <br />COMPARTMENTS AND OTHER SIMILAR <br />ROOMS SHALL BE PROVIDED WITH <br />MECHANICAL VENTILATION CAPABLE <br />OF 60 CFM EXHAUSTED DIRECTLY TO <br />THE OUTSIDE (R303.3) <br />280 CFM MIN, CHANGE EXHAUST FAN <br />(RANGE HOOD) EXHAUSTED DIRECTLY TO <br />THE OUTSIDE <br />1.TWO LAYERS OF GRADE D PAPER SHALL BE INSTALLED OVER <br />WOOD BASE SHEATHING (CBC 2506.4) <br />2.WEEP SCREED FOR STUCCO AT THE FOUNDATION PLATE LINE A <br />MINIMUM OF 4 INCHES ABOVE EARTH OR 2 INCHES ABOVE PAVED <br />AREAS. (CBC 2512.1.2) <br />3.EXTERIOR WALL COVERING OVER WEATHER-RESISTIVE BARRIER. <br />CBC 1403.2 <br />@ 16" O.C <br />R-15 INSUL. <br />1/2" DRYWALL <br />2X SILL PLATE <br />& FRAM. SCHEDULE <br />WALL ASSEMBLY DETAIL <br />PLWD. SHEAR PANEL <br />SEE FRAM. PLAN & <br />SCHEDULE <br />GRADE "D" BUILD. <br />PAPER (2) LAYERS <br />16 GA. WIRE LATH <br />2x4 STUDS <br />SEE SHEARWALL <br />CONC. FTG.5/8" A.B <br />7/8" EXT. PLASTER <br />26 GA. STUCCO WEEP SCREED <br />WITH MINIMUM 3-1/2” TALL <br />ATTACHMENT FLANGE PLACED <br />AT OR BELOW THE <br />SILL/CONCRETE INTERFACE <br />4" MIN. above NG <br />2" MIN. above FS <br />8" MIN. above NG <br />6" MIN. above FS <br />THRESHOLD DETAIL <br />CM <br />SDCM <br />SD <br />SD <br />280 CMF MIN. EXHAUST FAN <br />SHALL BE ENERGY STAR RATED, <br />EXHAUSTED DIRECTLY TO <br />OUTSIDE <br />(N) ADU <br />TANKLESS <br />WH <br />24" <br />CLEAR <br />2' <br />- <br />6 <br />" <br />30 <br />" <br /> <br />C <br />L <br />E <br />A <br />R <br />15 <br />" <br /> <br />M <br />I <br />N <br />. <br />30"MIN. <br />CLEAR te <br />m <br />p <br />e <br />r <br />e <br />d <br />tempered <br />tempered <br />36x37.5 <br />TH <br />- <br />A' <br />1/01-A1.3 <br />A <br />1/01-A1.3 <br />1.SMOKE ALARM <br />a.shall be interconnected hard-wired with <br />battery backup and shall be installed in <br />accordance with NFPA 72. <br />b.smoke alarms placed within 20 feet of a <br />permanently installed cooking <br />appliance shall be an ionization or <br />photoelectric type and shall not be within <br />10 feet of the appliance. <br />2.CARBON MONOXIDE ALARM <br />a.shall be interconnected hard-wired with <br />battery backup. <br />b.shall be physically or wirelessly <br />interconnected in such a manner that the <br />activation of one alarm shall activate all <br />the alarms. <br /> CRC R315.5] <br />FIRE PROTECTION NOTES <br />FUTURE HPWH <br />READY SPACE <br />(see detail HP/-) <br />HEAT PUMP WATER HEATER DETAIL <br />TH <br />WALL ASSEMBLY DETAIL <br />HP <br />a. Water closet – 1.28 gallon per flush <br />b. Shower head – 1.8 gallons per minute at 80 psi. <br />c. Lavatory faucets – 1.2 gallon per minute at 60 psi. <br />d. Kitchen faucet – 1.8 gallon per minute at 60 psi. <br />PLUMBING FIXTURES FLOW RATE LIMITATION (SECTION 4.303) <br />OF <br />SHEET NO. <br />DATE ISSUED DRAWN BY <br />CHECKED BY SCALE <br />PRINT:REVISION: <br />SH <br />E <br />E <br />T <br /> <br /> <br />N <br />A <br />M <br />E <br />: <br />THESE DRAWINGS, DESIGN AND SPECIFICATIONS ARE THE PROPERTY AND COPY RIGHT OF YOLANDA CASTRO AND/OR C+P DESIGN CONSTULTANTS AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH YOLANDA CASTRO. WRITTEN DIMENSIONS SHALL TAKE REFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE, ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF YOLANDA CASTRO TO THE COMMENCEMENT OF ANY WORK <br />PR <br />O <br />J <br />E <br />C <br />T <br />: <br />OW <br />N <br />E <br />R <br />: <br />AD <br />D <br />R <br />E <br />S <br />S <br />: <br />Y.C. <br />C+P <br />25 <br />C <br />P <br />0 <br />0 <br />6 <br />1 <br />AS SHOWN <br />5/3/2025 <br />STAMP APPROVAL <br />11-05-2025 <br />A. <br />P <br />. <br />N <br />. <br />40 <br />6 <br /> <br />S <br /> <br />W <br />e <br />s <br />t <br />e <br />r <br />n <br /> <br />A <br />v <br />e <br />, <br /> <br />U <br />n <br />i <br />t <br /> <br /># <br />2 <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />NE <br />W <br /> <br />A <br />C <br />C <br />E <br />S <br />S <br />O <br />R <br />Y <br /> <br />D <br />W <br />E <br />L <br />L <br />I <br />N <br />G <br /> <br />U <br />N <br />I <br />T <br />Ma <br />t <br />i <br />a <br />s <br /> <br />M <br />i <br />r <br />a <br />n <br />d <br />a <br />00 <br />7 <br />- <br />2 <br />2 <br />3 <br />- <br />0 <br />6 <br />12-22-2025 <br />2 01-20-2026 02/27/2026 <br />01-A1.1 <br />(E <br />) <br /> <br />F <br />L <br />O <br />O <br />R <br /> <br />P <br />L <br />A <br />N <br /> <br />W <br />I <br />T <br />H <br />DE <br />M <br />O <br />L <br />I <br />T <br />I <br />O <br />N <br /> <br />& <br /> <br />( <br />N <br />) <br /> <br />A <br />D <br />U <br />FL <br />O <br />O <br />R <br /> <br />P <br />L <br />A <br />N