(nrst Point Apartments - Sonta Ana, CA) <br />Commont #25 TAMMR Juslltlcatlonl: Provide construction dotails to show compliance wilh requhements of <br />CBC Soction 1206.3.2 tor horizontal ai lntake for each coud yard for lhis proiecl. <br />Resoonse: Horlzontal alr lntake at tho bottom of each Level 2 court ln Building A and B ls provid€d by <br />way ot tha open-end6d ,irefight€r lunnel connecting each court to at least one adjoining murt(s). CBC <br />Sscllon 1206.3.2 rsquires that cou( €ndosed on all four sides to be provided with a horizontal alr lntake <br />at tho bonom of the court or be adjacont to a yard or publlc way. To comply with the lntent of this <br />soction, lhe op6n-6nded flrefighler tunnels will provide an avenue for natural ventilation from an <br />adjacent court that is equivalent to the requlred opening of 10 square feet connected directly lo a street <br />or yard, Tho courts ln the prolect buildings are much larger than the minlmum dimensions roquired by <br />Section 1206.3 (i.e. 9'x 16' mlnimum dimensions for a s-story court). Courtyards 1 and 2 ln Bullding B <br />have approximate dimensions of 62' x 90'whora Courtyard 3 has approximate dimensions of 48'x90'. <br />These dlmenslons provlds a court area that ls at loast 30 times larger lhan the mlnimum sizo court <br />required by CBC Seclion 1206.3. The larger sizes of ths courts within the project bulldings do not have <br />the sams characteristics of a smaller four-sided court that can act as a chlmney durlng summer weather <br />whon lhe building mass is heated from the daytime sun (referenced attachad drawing sheet A2.2.1). <br />Additionally, it ls not lntonded for lhe courts to function as an efficlent source of natural ventilalion for the <br />spaces they front (i.e. dwelllng unlts, loungos, etc) therofore the requirement for having the courts abut a <br />yard or public way is l6ss esssntial. <br />,hosa rwo oxlt pas sagowdys show complldnce with tllla CBC Sectbn 1024.1.'... exlt pdssdgewdy otl olher then <br />lovel of exit discharyo, shall lermlnale al an exit'Arsq the opening protection in lhe exlt passogeways shal, <br />comply with Sectbns 1024.5, 716, and Table 716.5 roqulrements. <br />Response: Th6 fir€fighl6r tunnols ar6 provided for fire d€partment sccess to the lnterior courtyards per <br />OCFA Guldelin6 B-09. These tunnsls ar6 not utilizsd as an sxlt cornponent of the eorsss svstsm and <br />are not rsouired to comolv with tho rgoulroments for exit oassaoewavs. The cunent ogross schsme <br />does not rBquiro the lntroducuon of exit passageways at the lo$/est residentiel level 8s defined in the <br />CBC and as regulated by CBC Section 1024. These tunnels will be referred to as'2-Hour Ratod <br />Firerighter Tunnels' ln lleu of'2-Hour lnterior Exit Passagewa/ as previansly sho,vn on tho dra$/ings. <br />Per OCFA Guideline B-09, the interior doors opening into the tunnels will b€ g0-minute rated self- or <br />automatic-closing assemblies, but lhe ends of each segment of tunnel that connects the open court <br />yards should not be requlred to be endosed since the op€ning is required for firotighters to conducl their <br />operations. <br />ln addition to th€ dan checl cornment responses abo/e, tho design t€am nror.rld like to address the disatErgo of <br />interior 6xlt stalru/ays at L€vel l: <br />Eoress Court Condition: The interior exit stdruray identilied as Stair *1 discharges st L€vd 1 to a p.ivate <br />sid€ualk located on the rrEst side <br />of the project that leads to tho public way on East First Stre€t. The property lin€ is located apprqimately 6.5- <br />feet frqn the face of the €xterior wall on the vuesi side of the building. As such, thls cteatos an egr€ss court <br />conditicn that is less than 1o-feet in widlh measured betLEen the exterior wall cf ttle boildng ard the prop€rty <br />line. See Exhitit A attach€d. <br />Psg€ 3 oI4 I Nov€rnb€r 25, 20'19 I Rsr, I jenscnhqhas.cont