My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10198789 - Permit
PBA
>
Building
>
Permits
>
F
>
First St
>
2116 E First St
>
10198789 - Permit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/5/2021 11:31:56 AM
Creation date
11/5/2021 11:31:53 AM
Metadata
Fields
Template:
Permit
Permit Number
10198789
Full Address
2116 E First St
Permit ID
249530
Master ID Number
2018-147742
Project Name
AMG First Point Mixed Use Community
Street Number
002116
Street Direction
E
Street Name
First
Street Suffix
St
Building Use Code
Resid-Multi-unit
Job Types
New
Permit Type
Building
Applied Date
1/3/2019
Flood Zone
X-0602320277J
Description of Work
Parking structure-1st level/TUSD #4708 PLBG AND BLDG FCWP STILL DUE ***@ Violets old desk***
Nature of Work
Parking Structure
Document Relationships
10198789-90_Structural Calculations - Plan
(Plan)
Path:
\Building\Plans\F\First St\2116 E First St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
(Fitst Point Apa ntents - *rnto A,ro, C{) <br />Where a building is constructed on the adjacent property and withln 3.5 feet of the property the extarior wall of <br />this building will b€ required to achieve at l€ast a 1-hour rire resistance rating based on fire separation distance <br />and Table 602. Although th€ exterior wall ot the adjacent bullding may have openings located '1o-feet above the <br />walking surface of the egress court, the opsnings would not need to be rated since the egress court serves <br />occupants exiting the First Pointe Apartments and not the adjacent building. lf the future adjacent bullding <br />utilizes this same egress coun as an exil component then the exterior wall of the adiacent building will need to <br />b€ rated and have protec,ted openlr -^ <br />lsaac Martlnez, PE, CFPS <br />Sr. Fira Protec{on Enginesl <br />imartinez@jensenhughes.com <br />213.412.14@ <br />HARO <br />o <br />FP 1 893 <br />Exp tlra <br />Page 4 of4 I Novernber 25, 20'19 I Ret, 1 jensenluglns.cant <br />Per the requirements of S€ction '1028.4, the oxterior walls of the building will be required to achieve at least a 1- <br />hour fire resistanc€ rating for a distance of lo-feet above the floor of the egress court. Oponings in this portion <br />of th€ wall should achieve a 4s-mlnute firs protectlon ratlng. The exterior wall at this location ls alroady <br />constructed to achieve I l-hour rating, Unprotocled openings in this wall will be lnfilled. The extent ofthe rating <br />should oxtend as shown on the attachod exhibit. <br />Sincerely, <br />Jensen Hughes
The URL can be used to link to this page
Your browser does not support the video tag.