GENERAL STRUCTURAL NOTES <br />CITY OF SANTA ANA <br />PI nning and Building Agenc <br />GENERAL NOTES <br />1. NOTES: NOTES PROVIDED ON STRUCTURAL PLANS SHALL TAKE PRECEDENCE OVER THESE <br />GENERAL NOTES AND SPECIFICATIONS. <br />2. DIMENSIONS: WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS. <br />CONTRACTOR SHALL CHECK ALL DIMENSIONS AGAINST ARCHITECTURAL PLANS PRIOR TO <br />CONSTRUCTION. <br />3. CODES AND SPECIFICATIONS: ALL WORK AND CONSTRUCTION SHALL COMPLY WITH ALL <br />APPLICABLE BUILDING CODES, SPECIFICATIONS, REGULATIONS AND SAFETY REQUIREMENTS. <br />4. SAFETY: DURING THE CONSTRUCTION PERIOD THE CONTRACTOR SHALL BE RESPONSIBLE <br />FOR THE SAFETY OF THE BUILDING. THE CONTRACTOR SHALL PROVIDE ADEQUATE <br />SHORING, BRACING AND GUYS IN ACCORDANCE WITH ALL NATIONAL, STATE AND LOCAL <br />SAFETY ORDINANCES. <br />5. ERECTION: ALL ERECTION PROCEDURES SHALL CONFORM TO OSHA STANDARDS. ANY <br />DEVIATION MUST BE APPROVED BY OSHA PRIOR TO ERECTION. <br />6. EARTH WORK: THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL EXCAVATION <br />PROCEDURES INCLUDING LAGGING, SHORING AND PROTECTION OF ADJACENT PROPERTY, <br />STRUCTURES, STREETS AND UTILITIES IN ACCORDANCE WITH ALL NATIONAL, STATE AND <br />LOCAL SAFETY ORDINANCE. <br />7. OTHER TRADES: THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK <br />OF ALL TRADES AND SHALL CHECK ALL DIMENSIONS AND CONDITIONS OF THE JOB. ALL <br />DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF THE ARCHITECT OR ENGINEER <br />AND BE RESOLVED BEFORE PROCEEDING WITH WORK. <br />8. SHOP DRAWINGS: SHOP DRAWINGS REQUIRED BY THE SPECIFICATIONS SHALL BE <br />SUBMITTED TO THE ARCHITECT OR ENGINEER FOR REVIEW PRIOR TO FABRICATION. <br />9. DETAILS: DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS AND NOTES OF <br />CONSTRUCTION, WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF <br />SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE <br />USED SUBJECT TO REVIEW BY THE ARCHITECT OR ENGINEER. <br />10. OPENINGS: SEE ARCHITECTURAL DRAWINGS FOR SIZE AND LOCATION OF ALL FLOOR AND <br />WALL OPENINGS, FLOOR FINISHES, ETC. <br />11. OTHER TRADES: SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR SIZE AND <br />LOCATION OF ALL OPENINGS REQUIRED FOR DUCTS, PIPES AND ALL PIPE SLEEVES, <br />ELECTRICAL CONDUITS AND OTHER ITEMS TO BE EMBEDDED IN CONCRETE OR OTHERWISE <br />INCORPORATED IN STRUCTURAL WORK. <br />12. SPECIAL DETAILS: PROVIDE OPENINGS AND SUPPORTS, AS REQUIRED PER SPECIAL DETAILS <br />FOR HEATERS, MECHANICAL EQUIPMENT, VENTS, DUCTS, PIPING, ETC. ALL SUSPENDED <br />MECHANICAL EQUIPMENT TO BE STAYED OR LATERALLY BRACED. <br />13. MODIFICATIONS: ALL INFORMATION SHOWN ON THE DRAWINGS, RELATIVE TO EXISTING <br />CONDITIONS IS GIVEN AS THE BEST PRESENT KNOWLEDGE, BUT WITHOUT GUARANTEE OF <br />ACCURACY, WHERE ACTUAL CONDITIONS CONFLICT WITH THE DRAWINGS THEY SHALL BE <br />REPORTED TO THE ARCHITECT OR ENGINEER SO THAT PROPER REVISIONS MAY BE MADE. <br />MODIFICATION OF DETAILS OF CONSTRUCTION SHALL NOT BE MADE WITHOUT WRITTEN <br />APPROVAL OF THE ARCHITECT AND ENGINEER. <br />14. OTHER PLANS: ARCHITECTURAL AND MECHANICAL PLANS ARE CONSIDERED AS PART OF <br />THE STRUCTURAL DESIGN DRAWINGS AND ARE TO BE USED TO DEFINE DETAIL <br />CONFIGURATIONS INCLUDING, BUT NOT LIMITED TO RELATIVE LOCATION OF MEMBERS, <br />ELEVATIONS, LOCATION OF ALL OPENINGS, ETC. <br />15. OTHER ITEMS: SKYLIGHT, STOREFRONT STAIR FABRICATOR, ETC. SHALL SUBMIT STRUCTURAL <br />DESIGN CALCULATIONS AND DRAWINGS FOR ALL FRAMING MEMBERS AND CONNECTIONS <br />(INCLUDING CONNECTIONS TO STRUCTURAL MEMBERS) TO STRUCTURAL ENGINEER AND <br />BUILDING DEPARTMENT FOR THEIR APPROVAL PRIOR FABRICATION. CALCULATIONS AND <br />DRAWINGS SHALL COMPLY WITH ALL REQUIREMENTS OF LATEST APPLICABLE BUILDING. <br />THESE DRAWINGS SHALL BE DESIGNED AND SIGNED BY A REGISTERED ENGINEER. <br />16. MECHANICAL: MECHANICAL EQUIPMENT MUST BE FIRMLY ATTACHED TO THE STRUCTURE, <br />ISOLATORS, FASTENERS AND ANY OTHER ELEMENTS PROVIDING STABILITY FOR MECHANICAL <br />EQUIPMENT MUST BE APPROVED BY ICBO OF EQUIVALENT TO AT LEAST 0.3 TIMES <br />OPERATING WEIGHT OF EQUIPMENT. <br />17. SHORING: IT SHALL BE THE CONTRACTOR'S SOLE RESPONSIBILITY TO DESIGN AND PROVIDE <br />ADEQUATE SHORING, BRACING AND FORMWORK, ETC., AS REQUIRED FOR THE PROTECTION <br />OF LIFE AND PROPERTY DURING THE CONSTRUCTION OF THIS BUILDING. POST -TENSIONED <br />OR REINFORCED CONCRETE SLABS MAY CARRY SHORING LOADS EQUIVALENT TO THEIR <br />DESIGN SUPERIMPOSED LOADS INCLUDE LIVE LOAD, PARTITION LOAD AND ANY OTHER LOAD <br />NOT IN PLACE AT TIME OF SHORING. <br />18. BACKFILL: BACKFILL AROUND THE EXTERIOR PERIMETER OF WALLS SHALL NOT BE PLACED <br />UNTIL AFTER THE WALLS ARE SUPPORTED BY THE COMPLETION OF INTERIOR FLOOR <br />SYSTEM. DO NOT PROCEED WITH BACKFILL UNTIL 7 DAY (MINIMUM) AFTER THE <br />COMPLETION OF INTERIOR FLOOR SYSTEMS UNLESS WALLS ARE ADEQUATELY BRACED. <br />BACKFILL SHALL NOT BE PLACED UNTIL AFTER THE COMPLETION AND INSPECTION OF <br />DAMP PROOFING. <br />19. BRACING: DO ALL TEMPORARY BRACING AS REQUIRED TO HOLD THE VARIOUS ELEMENTS IN <br />PLACE UNTIL FINAL SUPPORT IS SECURELY ANCHORED. <br />20. THE DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE AND DO NOT <br />INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL SUPERVISE AND <br />DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, <br />METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES, INCLUDING, BUT NOT LIMITED TO <br />BRACING AND SHORING. OBSERVATION VISITS TO THE SITE BY THE ENGINEER SHALL NOT <br />INCLUDE INSPECTIONS OF THE PROTECTIVE MEASURES OF THE CONSTRUCTION <br />PROCEDURES. ANY SUPPORT SERVICES PERFORMED BY THE ENGINEER DURING THE <br />CONSTRUCTION SHALL BE DISTINGUISHED FROM CONTINUOUS AND DETAILED INSPECTION <br />SERVICES. THERE SUPPORT SERVICES PERFORMED BY THE ENGINEER, WHETHER OF <br />MATERIAL OF WORK AND WHETHER PERFORMED PRIOR TO, DURING OR AFTER COMPLETION <br />OF CONSTRUCTION, ARE PERFORMED SOLELY FOR THE PURPOSE OF ASSISTING IN QUALITY <br />CONTROL AND IN ACHIEVING CONFORMANCE WITH CONTRACT DOCUMENTS, BUT DO NOT <br />GUARANTEE CONTRACTOR'S PERFORMANCE AND SHALL NOT BY CONSTRUCTED AS <br />SUPERVISION OF CONSTRUCTION. <br />21. WHERE CONSTRUCTION MATERIALS ARE TEMPORARILY STORED ON ROOF OR FLOOR <br />FRAMING, THEY SHALL BE DISTRIBUTED SO THAT THE LOAD DOES NOT EXCEED DESIGN <br />LIVE LOAD. ADEQUATE SHORING AND/OR BRACING SHALL BE PROVIDED WHERE <br />STRUCTURAL MEMBERS HAVE NOT ATTAINED DESIGN STRENGTH. <br />22. ASTM DESIGNATION AND ALL STANDARDS REFER TO THE LATEST AMENDMENTS. <br />23. ALL WORK SHALL CONFORM TO THE 2022 EDITION OF CALIFORNIA BUILDING CODE, 2020 <br />EDITION OF LOS ANGELES BUILDING CODE AND 2021 OF INTERNATIONAL BUILDING CODE. <br />FOUNDATION <br />1. THE SOILS BEARING PRESSURE = 1,500 PSF <br />2. FOUNDATION DESIGN SHALL BE 24" MIN. DEPTH OF FTG BELOW LOWEST <br />ADJACENT FINAL GRADE, AND 12" MINIMUM WIDTH FOR 1 STORY, 15" <br />MIN. WIDTH FOR 2 STORY, BEAR ON FIRM NATIVE OR PROPERLY <br />COMPACTED SOILS. <br />3. NOT USED <br />4. GEOTECHNICAL ENGINEER OR DEPUTY INSPECTOR SHALL VERIFY THAT <br />CONSTRUCTION AT THE SITE IS IN ACCORDANCE WITH THE <br />RECOMMENDATIONS AND CONCLUSIONS OF HIS REPORT. FINISHED <br />EXCAVATION FOR FOUNDATION SHALL BE NEAT AND TRUE TO LINE WITH <br />ALL LOOSE MATERIAL AND STANDING WATER REMOVED FROM <br />EXCAVATIONS. <br />5. BEFORE ANY CONCRETE IS PLACED, EXCAVATIONS SHALL BE CHECKED <br />AND APPROVED BY A QUALIFIED SOILS ENGINEER OR DEPUTY INSPECTOR <br />TO ENSURE COMPLIANCE WITH THE REQUIREMENTS. <br />6. ALL FILL MATERIAL IS TO BE APPROVED BY THE SOILS ENGINEER OR <br />DEPUTY INSPECTOR AND APPROVED BY A QUALIFIED SOILS ENGINEER <br />OR DEPUTY INSPECTOR TO ENSURE COMPLIANCE W/ THE REQUIREMENTS. <br />7. SUBGRADE SHALL BE 2". <br />8. SIDE OF FOUNDATION MAY BE POURED AGAINST STABLE EARTH UNLESS <br />SHOWN OR NOTED OTHERWISE. <br />9. CONTRACTOR SHALL PROVIDE TEMPORARY AND PERMANENT DEWATERING <br />FOR EITHER SURFACE WATER, GROUND WATER OR SEEPAGE WATER. <br />10. CONTRACTOR SHALL PROTECT ALL UTILITY LINES, ETC. ENCOUNTERED <br />DURING EXCAVATIONS AND BACKFILLING. <br />11. CONTRACTOR SHALL PROVIDE AND INSTALL ALL CRIBBING SHEATHING AND <br />SHORING REQUIRED TO SAFELY RETAIN THE EARTH BANK. <br />12. FOOTING BACKFILL AND UTILITY TRENCH BACKFILL SHALL BE PROPERLY <br />COMPACTED. <br />13. CONTRACTOR SHALL BRACE OR PROTECT FROM LATERAL LOADS FOR THE <br />PIT AND RETAINING WALLS UNTIL ATTACHING SLABS ARE COMPLETELY IN <br />PLACE AND HAVE ATTAINED FULL STRENGTH. <br />14. NO VERTICAL EXCAVATIONS 4'-0" OR MORE IN DEPTH INTO WHICH A <br />PERSON IS REQUIRED TO DESEND SHALL BE PERMITTED. <br />EPDXY ANCHORS ; <br />1. EPDXY FOR EPDXY ANCHORS SHALL BE S -3G PDXY BY <br />"SIMPSON STRONG -TIE" (ICC ESR. #4057, 6117) <br />2. ANCHORS USED FOR EPDXY ANCHORS SHALL BE ASTM <br />A-307 THREADED RODS LINO. SIZE AND EMBEDMENT <br />SHALL BE AS INDICATED ON PLANS. <br />3. ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH THE <br />EPDXY MANUFACTURER'S RECOMMENDATIONS AND THE <br />CURRENT ICC REPORT. <br />4. SPECIAL INSPECTION SHALL BE PROVIDED IN ACCORDANCE <br />WITH CBC-2022 AND IN ACCORDANCE WITH THE SPECIFIC <br />SPECIAL INSPECTION REQUIREMENTS SET FORTH IN THE <br />CORRESPONDING ICC REPORT. <br />5. DRILLED HOLES SHALL BE CLEANED OF DUST AND ANY <br />DEBRIS USING NYLON BRUSH AND COMPRESSED AIR. OIL, <br />SCALE, AND RUST SHALL BE REMOVED FROM THREADED <br />RODS PRIOR TO INSTALLATION. <br />6. UNLESS NOTED OTHERWISE IN THE PLANS, EPDXY ANCHORS <br />SHALL HAVE THE FOLLOWING MINIMUM EMBEDMENT <br />BAR SIZE <br />MINIMUM EMBEDMENT * <br />REMARKS <br />#3 <br />3 1 /2" <br />#4 OR 1 /2"0 <br />4 1 /4" <br />#5 OR 5/8"0 <br />5 1 /2" <br />#6 OR 3/4"0 <br />6 3/4" <br />REINFORCING STEEL <br />1. ALL REINFORCING BARS SHALL BE ASTM A-615 GRADE 60 DEFORMED BILLET STEEL <br />BARS. <br />2. GRADE 60 BARS SHALL BE MARKED SO ITS IDENTIFICATION CAN BE MADE WHEN <br />THE FINAL IN PLACE INSPECTION IS MADE. <br />3. THE TIE WIRE USED SHALL BE BLACK ANNEALED WIRE, 16 GA. OR HEAVIER. <br />4. BAR SUPPORTS SHALL CONFORM TO THE BAR SUPPORT SPECIFICATIONS <br />CONTAINED IN THE "MANUAL OF STANDARD PRACTICE" BY ACI. <br />5. A CERTIFIED COPY OF MILL TEST ON EACH HEAT OF REINFORCING STEEL DELIVERED <br />SHOWING PHYSICAL AND CHEMICAL ANALYSIS SHALL BE PROVIDED UPON REQUEST AT <br />THE TIME OF SHIPMENT. <br />6. ALL REQUIREMENT OF CONCRETE REINFORCEMENT NOT COVERED ON THE DRAWINGS <br />SHALL BE IN ACCORDANCE WITH ACI "MANUAL OF STANDARD PRACTICE". <br />7. REINFORCING STEEL AT THE TIME OF THE CONCRETE IS PLACED SHALL BE FREE <br />FROM MUD, OIL, OR OTHER NON METALLIC COATINGS THAT ADVERSELY AFFECT <br />BONDING CAPACITY. <br />8. ALL HOOKS SHALL CONFORM TO THE BEND DIMENSION PER ACI "STANDARD HOOK" <br />UNLESS OTHERWISE SHOWN ON THE DRAWINGS. REINFORCING BARS SHALL NOT BE <br />BENT OR STRAIGHTENED IN A MANNER THAT WILL INJURE THE MATERIAL. <br />9. REINFORCING BARS SHALL CONFORM ACCURATELY TO THE DIMENSIONS SHOWN ON <br />THE DRAWINGS WITH THE FABRICATING TOLERANCES PER ACI "MANUAL OF STANDARD <br />PRACTICE." <br />10. BARS SHALL BE SECURELY TIED TO PREVENT DISPLACEMENT DURING THE CONCRETE <br />OPERATION AND ALL DOWELS SHALL BE WIRED IN PLACE BEFORE DEPOSITING <br />CONCRETE. <br />11. DOWELS BETWEEN FOOTINGS AND WALLS OR COLUMNS SHALL HAVE SAME SIZE AS <br />THE VERTICAL REINFORCEMENT, EMBEDMENT OF DOWELS SHALL BE 36 BAR <br />DIAMETER OR 2'-0" MINIMUM UNLESS OTHERWISE SHOWN. <br />12. MINIMUM LAP OF MESH SHALL BE NOT LESS THAN THE SPACING OF THE CROSS <br />WIRE PLUS TWO INCHES OR 60 DIA. OR 8 IN. WHICHEVER IS GREATER. <br />STRUCTURAL STEEL & MISCELLANEOUS STEEL <br />1. STRUCTURAL STEEL SHALL CONFORM TO ASTM A572, GRADE 50, OR DUAL <br />GRADE A992(MIN. Fy-50 KSI) ANGLES, CHANNELS AND PLATES TO CONFORM <br />TO ASTM A36. TUBE COLUMNS SHALL CONFORM TO ASTM A500, GRADE B <br />AND PIPE COLUMNS SHALL CONFORM TO ASTM A53, GRADE B. STEEL <br />BEAMS W10 OR SMALLER MAY BE A36 STEEL. <br />2. ALL MATERIAL, FABRICATION AND CONSTRUCTION SHALL BE IN ACCORDANCE <br />WITH THE LATEST A.I.S.C. SPECIFICATIONS AS APPROVED BY THE CHECKING <br />AGENCY AND AS AMENDED IN GENERAL NOTES AND SPECIFICATIONS. <br />3. SHOP DRAWINGS SHALL BE SUBMITTED TO ARCHITECT AND STRUCTURAL <br />ENGINEER FOR REVIEW PRIOR TO FABRICATION. <br />4. FABRICATOR SHALL BE LOCAL JURISDICTION CERTIFIED FABRICATOR. <br />5. ALL WELDERS SHALL BE CERTIFIED BY LOCAL JURISDICTION BUILDING <br />DEPARTMENT. ALL WELDING AND ALL MULTI -PASS AND GROOVE WELDS <br />SHALL HAVE CONTINUOUS INSPECTION. WELDING SHALL CONFORM TO A.W.S. <br />D1.1. THE ELECTRODE SHALL BE E70XX AND HAVE A CHARPY V-NOTCH <br />TOUGHNESS OF 20 FT-LBS AT 707. <br />6. BOLTS SHALL BE HIGH STRENGTH CONFORMING TO ASTM A-325. ALL BOLTS <br />AT DRAG STRUTS AND BRACE FRAME CONNECTIONS SHALL BE ASTM A-325 <br />"SLIP CRITICAL". INSTALLATION OF HIGH STRENGTH BOLTS SHALL CONFORM <br />TO THE SPECIFICATIONS FOR STRUCTURAL JOINTS USING ASTM A-325 OR <br />A-490 BOLTS. TORQUE WRENCH TESTING IS REQUIRED ONLY FOR "SLIP <br />CRITICAL" CONNECTION. <br />7. BOLT HOLES SHALL BE 1 /16 INCH LARGER IN DIAMETER THAN THE BOLT <br />NOMINAL SIZE. <br />8. WELDING ELECTRODES SHALL BE E70XX COMFORMING TO AWS D1.1 LOW <br />HYDROGEN. <br />9. FILLET WELDS NOTED ARE FOR DESIGN LOADS. FOR WELDS TO HEAVIER <br />SECTIONS, USE PREHEAT OR INCREASE WELD SIZE PER AISC <br />SPECIFICATIONS. <br />10. ALL WELDING SHALL HAVE CONTINUOUS INSPECTION BY AWS CERTIFIED <br />WELDING INSPECTOR. <br />STRUCTURAL DESIGN CRITERIA <br />WIND DESIGN DATA: <br />BASIC WIND SPEED....................................110 MPH <br />RISK CATEGORY ........................................ II <br />WIND EXPOSURE ......................................... B <br />EARTHQUAKE DESIGN DATA: <br />IMPORTANCE FACTOR I...............................1.0 <br />SITE CLASS ................................................. D <br />Ss............................................................... 1.289 <br />S1............................................................... 0.461 <br />SDs............................................................. 1.031 <br />SD1.............................................................0.461 <br />SEISMIC DESIGN CATEGORY ....................... D <br />BASIC SEISMIC FORCE -RESISTING SYSTEM Light -frame 'roeed)�wates! .1 <br />w7wood strt'Ctural panels <br />DESIGN BASE SHEAR ................................... 3.81 PSF <br />Cs............................................................... 0.1586 <br />DEAD LOAD <br />R................................................................. 6.5 (PSF) <br />USE EQUVALENT LATERAL FORCE PROCEDURE <br />i ROOF 15 2� <br />CONCRETE <br />1. ALL CONCRETE SHALL BE NORMAL WEIGHT CONFORMING TO THE FOLLOWING <br />LOCATION: <br />28-DAY MIN. <br />MAXIMUM <br />MIX DESIGN <br />COMPRESSIVE <br />AGGREGATE <br />SLUMP <br />STRENGTH <br />SIZE (IN.) <br />(INCHES) <br />A. SLAB ON GRADE <br />2500 psi <br />1 <br />3 (4" MAX) <br />B. FOOTING <br />2500 psi <br />1 <br />4 (5" MAX) <br />W/5.0 SACKS CEMENT <br />(MIN.) <br />* WHERE SULFATE EXPOSURE LEVEL IS <br />SEVERE USE 4500 <br />psi <br />WITH W/C RATIO OF <br />0.45 (MAX) <br />2. ALL CONCRETE MIX DESIGN SHALL BE REVIEWED BY THE ENGINEER PRIOR <br />TO CONSTRUCTION. <br />3. PORTLAND CEMENT SHALL CONFORM TO ASTM C-150, TYPE II CEMENT. <br />4. AGGREGATE SHALL CONFORM TO ASTM C-33. <br />5. WATER SHALL BE CLEAN, FREE FROM DELETERIOUS AMOUNTS OF ACIDS, <br />ALKALIS OR ORGANIC MATERIALS, OILS, SALTS AS PER ACI 318. <br />6. CONCRETE MIXING OPERATIONS, ETC. SHALL CONFORM TO ASTM C-94. <br />7. WATER -CEMENT RATIO IS LESS THAN 0.50 <br />8. UNLESS SHOWN OR NOTED OTHERWISE, CONCRETE COVERAGE FOR <br />REINFORCING BAR TO FACE OF BAR SHALL BE AS FOLLOWS: <br />A. CONCRETE IN CONTACT WITH EARTH, UNFORMED 3" <br />B. CONCRETE IN CONTACT WITH EARTH, FORMED 2" <br />C. WALLS <br />1.5" <br />D. BEAMS, GIRDERS & COLUMNS (TO TIES OR STIRRUPS) 1.5" <br />8. CONDUIT PLACED IN A CONCRETE SLAB SHALL NOT EXCEED 1/3 OF THE <br />THICKNESS OF THE SLAB AND SHALL BE PLACED BETWEEN THE TOP AND <br />BOTTOM REINFORCING STEEL. MINIMUM CLEAR DISTANCE BETWEEN CONDUITS <br />SHALL BE 6". <br />9. CONSTRUCTION JOINTS: <br />THE SURFACES OF ALL CONSTRUCTION JOINTS SHALL BE CLEAN, FREE <br />FROM LOOSE DEBRIS. IMMEDIATELY BEFORE NEW CONCRETE IS PLACED, <br />ALL CONSTRUCTION JOINTS SHALL BE WETTED AND STANDING WATER <br />REMOVED. <br />10. CONCRETE SHALL BE CURED IN ACCORDANCE WITH 2O22 C.B.C. <br />11. REMOVAL OF CONCRETE FORMS AND SHORES SHALL BE IN ACCORDANCE <br />WITH 2O22 C.B.C. <br />12. CONDUITS AND PIPES EMBEDDED IN CONCRETE SHALL COMPLY WITH THE <br />PROVISION OF 2022 C.B.C. <br />13. DESIGN AND CONSTRUCTION OF CONCRETE FORMWORK SHALL CONFORM TO <br />ACI 347 "RECOMMENDED PRACTICE FOR CONCRETE FORMWORK". <br />14. ALL SAW CUTS IN SLAB ON GRADE SHALL BE MADE NOT LATER THAN 24 <br />HOURS AFTER PLACING CONCRETE. <br />ROUGH CARPENTRY <br />1. ALL LUMBER SHALL BE GRADE MARKED DOUGLAS FIR LARCH (DFL). <br />A.) BEAMS, HEADERS & POSTS NO.1 OR BETTER <br />B.) RAFTERS & JOISTS NO.2 OR BETTER <br />2. ALL FOUNDATION PLATES OR SILLS AND SLEEPERS ON A CONCRETE OR <br />MASONRY SLAB, WHICH IS IN DIRECT CONTACT WITH EARTH, AND SILLS THAT <br />REST ON CONCRETE OR MASONRY FOUNDATIONS, SHALL BE PRESSURE <br />TREATED DOUGLAS FIR. <br />3. WOOD SILL PLATES SHALL HAVE 3/4" DRYPACK UNDER, EXCEPT WHERE <br />NOTED. ANCHOR BOLTS: 5/8"0 X 12" BOLTS @ 4'-0" O.C. WITH 2 1 /2" <br />SQ. x 1 /4" PLATE WASHERS, WITH MINIMUM 2 ANCHOR BOLTS PER PIECE, <br />LOCATED NOT MORE THAN 12" OR LESS THAN 7 DIAMETERS FROM EACH <br />END OF THE PIECE. <br />4. PROVIDE WASHERS UNDER HEADS AND NUTS OF BOLTS AND LAG SCREWS <br />BEARING ON WOOD. NUTS ON ALL BOLTS SHALL BE TIGHTENED BEFORE <br />CLOSING IN AND/OR ON COMPLETION OF THE JOB. CUT WASHERS MAY BE <br />USED EXCEPT FOR SILL BOLTS AT SHEARWALLS AND WHERE NOTED <br />OTHERWISE. <br />5. BOLTS SHALL CONFORM TO ASTM A307. BOLT HOLES TO BE NOMINAL <br />DIAMETER OF BOLT + 1 /16" UNLESS NOTED OTHERWISE. <br />6. NO STRUCTURAL MEMBER INCLUDING STUDS AND PLATES SHALL BE CUT OR <br />NOTCHED FOR PIPES, ETC., UNLESS SPECIFICALLY SHOWN, NOTED OR <br />ACCEPTABLE TO THE STRUCTURAL ENGINEER. FOR REQUIREMENTS FOR <br />BORED HOLES. <br />7. PLYWOOD ROOF SHEATHING AND SHEAR WALL SHEATHING, APA GRADE <br />MARKED STRUCTURAL 1, EXT. SHTG. C-C. SEE SPECIFICATIONS. <br />8. PLYWOOD SHEATHING SHALL BE IN SINGLE PIECES WHERE POSSIBLE WITH 4' <br />X 8' MIN. SHEETS. SOLID BLOCK ROOF SHEATHING AND WALL PANEL <br />PLYWOOD EDGES. MINIMUM SHEET DINENSION AT BOUNDARIES AND <br />CHANGES IN FRAMING SHALL BE 24". <br />9. METAL FRAMING ACCESSORIES: STEEL JOISTS HANGERS, FRAMING ANCHORS <br />FASTENERS AND OTHER SUCH CONNECTION DEVICES SHALL BE OF <br />STANDARD MANUFACTUR OF THE TYPE REQUIRED BY THE DRAWINGS. NAILS <br />SHALL BE THOSE FURNISHED BY THE MANU- FACTURER FOR THIS SPECIFIC <br />USE. DEVICES SHALL BE GALVANIZED. "SIMPSON" PART NUMBERS ARE <br />SHOWN ON DRAWINGS. <br />10. PROPERTIES OF LUMBER <br />4x OR 2x <br />DFL. NO.1 <br />Fb = <br />1,000 PSI, Fv = <br />95 PSI, E = <br />1,700 KSI <br />DFL. NO.2 <br />Fb = <br />900 PSI, Fv = <br />95 PSI, E = <br />1,600 KSI <br />6x AND LARGER <br />DFL. NO.1 <br />Fb <br />= 1,350 PSI, Fv <br />= 85 PSI, E <br />= 1,600 KSI <br />SELECT STRUCT. <br />Fb <br />= 1,600 PSI, Fv <br />= 85 PSI, E <br />= 1,600 KSI <br />PARALLAM <br />Fb <br />= 2,900 PSI, Fv <br />= 290 PSI, E <br />= 2,000 KSI <br />MICROLLAM <br />Fb <br />= 2,600 PSI, Fv <br />= 285 PSI, E <br />= 1,900 KSI <br />11. PLATE WASHERS FOR ALL ANCHOR BOLTS TYPICAL: <br />BOLT SIZE <br />PLATE SIZE (ASTM A-36) <br />MIN. EDGE DISTANCE (in) <br />5/8"0 <br />0.229"0"0" <br />1 7/8 <br />3/4"0 <br />0.229"x3"x3" <br />2 1 /2 <br />7/8"0 <br />5/16"x3"x3" <br />2 5/8 <br />1 1 /4"0 <br />3/8"x3 1 /2"x3 1 /2" <br />3 3/4 <br />LOAD NOTE: <br />APPROVE PLATE WASHERS TO BE USED FOR PLYWOOD SHEARWALL <br />SILL PLATE ANCHOR BOLTS* AND FOR HOLDOWN CONNECTOR <br />BOLTS AT SHEARWALLS. FOR WOOD TO WOOD OR WOOD TO STEEL <br />CONNECTION. <br />FASTENING SCHEDULE <br />COMMON NAIL <br />1. <br />JOIST TO SILL OR GIRDER, TOENAIL <br />3-8d <br />2. <br />BRIDGING TO JOIST, TOENAIL EACH END <br />2-8d <br />3. <br />1 " X 6" SUBFLOOR OR LESS TO EACH JOIST, FACE <br />NAIL 2-8d <br />4. <br />WIDER THAN 1" X 6" SUBFLOOR TO EACH JOIST, FACE NAIL 3-8d <br />5. <br />2" SUBFLOOR TO JOIST OR GIRDER, BLIND AND FACE <br />NAIL 2-16d <br />6. <br />SOLE PLATE TO JOIST OR BLOCKING FACE NAIL <br />16d AT 16" O.C. <br />SOLE PLATE TO JOIST, AT BRACED WALL PANEL <br />2-16d PER 16" <br />7. <br />TOP PLATE TO STUD, END NAIL <br />2-16d <br />8. <br />STUD TO SOLE PLATE <br />4-8d, TOE NAIL OR <br />SUPERSEDE THE SPECIFICATIONS OF WPSE.(END NAILS 2-16d, END NAIL <br />9. <br />DOUBLE STUDS, FACE NAIL <br />16d AT 24" O.C. <br />10. <br />DOUBLE TOP PLATES, FACE NAIL <br />16d AT 16" O.C. <br />DOUBLE TOP PLATES, LAP SPLICE <br />8-16d <br />11. <br />BLOCKING BETWEEN JOIST OR RAFTERS TO TOP PLATE, TOE NAIL _ 3-8d <br />12. <br />RIM JOIST TO TOP PLATE, TOE NAIL <br />8d AT 6" O.C. <br />13. <br />TOP PLATES, LAPS AND INTERSECTIONS, FACE NAIL <br />2-16d <br />14. <br />BUILT-UP HEADER (2" TO 2" HEADER) <br />16d AT 16" O.C. <br />ALONG EACH EDGE <br />15. <br />CEILING JOISTS TO PLATE, TOE NAIL <br />3-8d <br />16. <br />CONTINUOUS HEADER TO STUD, TOE NAIL <br />4-8d <br />17. <br />CEILING JOISTS, LAPS OVER PARTITIONS, FACE NAIL <br />3-16d <br />18. <br />CEILING JOISTS TO PARALLEL RAFTERS, FACE NAIL <br />3-16d <br />19. <br />RAFTER TO PLATE, TOE NAIL <br />3-10d <br />20. <br />1 " BRACE TO EACH STUD AND PLATE, FACE NAIL <br />2-8d <br />21. <br />1" X 8" SHEATHING OR LESS TO EACH BEARING, FACE NAIL 3-8d <br />22. <br />WIDER THAN 1" X 8" SHEATHING TO EACH BEARING, <br />FACE NAIL - 3-8d <br />23. <br />BUILT-UP CORNER STUDS <br />16d AT 24" O.C. <br />24. <br />BUILT-UP GIRDER AND BEAMS <br />20d AT 32" O.C. AT TOP <br />AND <br />BOTTOM AND STAGGERED <br />2-20d AT ENDS AND AT <br />EACH SPLICE <br />25. <br />2" PLANKS <br />2-16d AT EACH BEARING <br />26. <br />COLLAR TIE TO RAFTER <br />3-10d <br />27. <br />JACK RAFTER TO HIP / ROOF RAFTER <br />3-1Od TOENAIL <br />TO 2-BY RIDGE BEAM <br />2-16d END NAIL <br />28. <br />JOIST TO BAND JOIST <br />3-16d <br />* NOTE: COMMON OR BOX NAILS MAY BE USED (U.N.O.) <br />I <br />BOX NAIL <br />3-10d <br />2-10d F <br />2-10d <br />3-10d <br />N/A <br />16d AT 12" O.C. <br />3-16d PER 16" <br />3-10d <br />Approved <br />R PERMIT ISSUANCE <br />4-10d, TOE NAIL OR Ma ter ID: <br />3-10d, <br />END NAIL <br />10d AT <br />16" O.C. Dale: <br />10d AT <br />12 O.C. <br />12-10d <br />3-10d <br />10 d AT <br />6 " 0. C. <br />3-10d <br />16d AT <br />12" O.C. <br />ALONG <br />EACH EDGE <br />3-10d <br />4-10d <br />4-10d <br />4-10d <br />3-16d <br />2-10d <br />3-10d <br />3-10d <br />16d AT <br />12" O.C. <br />10d AT <br />24" O.C. AT TOP <br />AND BOTTOM AND STAGGERED <br />3-10d <br />AT ENDS AND AT <br />EACH SPLICE <br />N/A <br />4-10d <br />3-16d <br />TOENAIL <br />3-10d <br />END NAIL <br />4-10d <br />AHJ STAMP APPROVAL <br />FfC <br />IFCENGIN ENGINEERING, INC. <br />CONSULTING ENGINEERS <br />STRUCTURAL DESIGN <br />1822 E Route 66, Suite 328 <br />Glendora, CA 91740 <br />Office: (818) 814-8268 <br />Email: ifcengineeringca@gmail.com <br />THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND <br />CONDITIONS OF THE JOB PRIOR TO STARTING <br />CONSTRUCTION, AND THE ARCHITECT/ DESIGNER/ <br />ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF ANY <br />DISCREPANCIES INCONSISTENCIES. CHECK WITH <br />ARCHITECT FOR ACTUAL DIMENSIONS. <br />THIS DRAWINGS, DOCUMENTS, DESIGNED ARE THE <br />PROPERTY AND COPYRIGHTS OF IFC ENGINEERING. <br />THOSE ARE FOR USE ON THE SPECIFIED PROJECT, AND <br />NO PART THEREOF SHALL BE COPIED OR DISCLOSED TO <br />OTHERS WITHOUT WRITTEN PERMISSION FROM IFC <br />ENGINEERING. <br />QROVESS/ONq <br />C. <br />Flo. C69393 <br />W Ex 06/30/2026� <br />V <br />9T CIVIC ��Q <br />\or CAL�F�� <br />Stamp: <br />Residential Project for: <br />PRIVATE <br />RESIDENCE <br />1519 PARK DRIVE <br />SANTA ANA, CA 92707 <br />Project: <br />STRUCTURAL <br />NOTES & <br />DETAILS <br />Drawing Title: <br />PLAN CHECK <br />, 02-08-2026 <br />PLAN CHECK #1 <br />/2\ PCC2 03-08-2026 <br />Revisions: Date <br />Date: 11-22-2025 <br />Scale: 1 /4"= V-0" <br />Drawn By: IFC <br />Job Number: 1102015A <br />SD1 <br />